Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Certified Passive House component for cool, temperate climate, valid until 31.12.2014 Category: Manufacturer: Product name: Window Frame Hilzinger FBS GmbH 53909 Zülpich, GERMANY VADB-Plus 550 The following comfort criteria were used in awarding this certificate: Passive House Efficiency Class Given a Ug value of 0.70 W/(m²K) and a window size of 1.23 m by 1.48 m, UW = phA advanced component 0.76 W/(m²K) ≤ 0.80 W/(m²K) Taking into account the installation based thermal bridges, and provided that the installation is, with regard to the thermal bridges, equal or better than shown in the data sheet, the window meets the following criterion. UW,installed phB basic component ≤ 0.85 W/(m²K) phC certifiable component Thermal data of the window frame Spacer Bottom Side/top Uf-value Width [W/(m²K)] [mm] 0.68 0.64 100 75 Ψg fRsi=0.25 [W/(mK)] TPS* 0.024 0.026 [-] 0.73 *Spacers of lower thermal quality, especially those made of aluminium, lead to significantly higher thermal losses and lower temperature factors. Further information see data sheet www.passivehouse.com 0037wi03 not suitable for Passive Houses Data Sheet Hilzinger FBS GmbH, VADB-Plus 550 Manufacturer Hilzinger FBS GmbH Bergheimer Str. 21, 53909 Zülpich, GERMANY Tel.: +49 (0)2252 2064 Email: [email protected], www.hilzinger.de Bottom section Isothermal Description Plastic frame Thermal data for the window frame Spacer Bottom Side/top Mullion 110 Mullion 125 Uf-value Width Ψg [W/(m²K)] [mm] [W/(mK)] fRsi=0.25 [-] TPS* 0.68 0.64 0.67 0.64 100 75 110 125 0.024 0.026 0.026 0.025 0.73 0.73 0.73 Mullion * Spacers of lower thermal quality leading to higher thermal losses and lower temperatures. www.passivehouse.com Passive House Institute Page 1/3 Data Sheet Hilzinger FBS GmbH, VADB-Plus 550 Installation Installation based thermal bridge Ψinstal. [W/(mK)] [W/(m²K)] Insulated formwork blocks [W/(mK)] Timber construction wall Position Bottom Side/top UW,instal. EIFS in Passive House suitable walls 0.016 0.007 0.79 0.028 0.020 0.82 0.011 0.007 0.78 Explanatory notes The window U-values were calculated based on a 1.23 m by 1.48 m window Ug = 0.70 W/(m²K). If better glazing is used, the window U-value decrease as follow: U Glazing Ug [W/(m²K)] 0.66 0.60 0.54 U Window UW [W/(m²K)] 0.73 0.68 0.63 Depending on the thermal losses through opaque elements, windows are categorised according to efficency classes. These thermal losses include the losses through the frame, multiplied by its width, the thermal bridge at the edge bondedge bond as well as the length of the edge bond. Please ask the manufacturer for a detailed report containing all calculations and results. For further information, please visit www.passivehouse.com or www.passipedia.org. www.passivehouse.com Passive House Institute Page 2/3 Datenblatt FBS Over GmbH, VADB-Plus 550 S Manufacturer Hilzinger FBS GmbH Bergheimer Str. 21, 53909 Zülpich, GERMANY Tel.: +49 (0)2252 2064 Email: [email protected], www.hilzinger.de Bottom section Isothermal Description Plastic frame reinforced with steel Thermal data for the window frame Abstandhalter Unten Seitlich/oben Stulp 110 Stulp 125 Uf-value width Ψg [W/(m²K)] [mm] [W/(mK)] fRsi=0.25 [-] TPS* 0.81 0.84 0.83 0.85 100 75 110 125 0.025 0.025 0.024 0.025 0.73 0.72 0.72 * Spacers of lower thermal quality leading to higher thermal losses and lower temperatures. www.passivehouse.com Mullion Passive House Institute Page 3/3
© Copyright 2024 ExpyDoc