Spring toggle KD 3+4, KDH 3+4

The cavity fixing for different board thicknesses and large
usage lengths
Cavity fixings
Spring toggle KD 3+4, KDH 3+4
BUILDING MATERIALS
▪ Gypsum plasterboard and gypsum
fibreboards
▪ Cavity floor slabs made from bricks
and concrete
▪ Chipboard
▪ Plywood
ADVANTAGES
APPLICATIONS
FUNCTIONING
▪ The long threaded rod of the toggle
fixings KD and KDH allows for use
with different board thicknesses and
thick attachments, and offers
maximum flexibility.
▪ An integrated tension spring causes
the catch elements of the spring
toggles KD 3+4 and KDH 3+4 to
open independently, thus allowing
for a simple installation.
▪ The wide transition beams ensure a
good load distribution. This achieves
a high load-bearing capacity.
▪ The nylon gravity toggle K54 allows
for the use of standard wood and
chipboard screws.
▪
▪
▪
▪
▪
▪
▪
▪
▪ The gravity and spring toggle are
suitable for pre-positioned
installation.
▪ When placed in the drill hole, the
bearing elements of the gravity and
spring toggles independently swing
open behind the board.
▪ The KM 10 is specially suited to
fixing wash basins and urinals into
installation and cavity walls.
▪ No special installation tool required.
For a fast and convenient
installation.
http://www.fischer.de/en/ - 16/09/2014
Pictures
Lighting
Light shelves
Towel rails
Mirror cabinets
Light cabinets
Wash basins and urinals (KM 10)
Cable and pipe clips
1
TECHNICAL DATA
Spring toggle KD 3+4, KDH 3+4
Drill hole diameter
Article name
KD 3
KDH 3
KD 3 B
KD 4
KDH 4
KD 4 B
Art.-No.
080181
080182
080192
080183
080184
080193
http://www.fischer.de/en/ - 16/09/2014
do
[mm]
12
12
12
14
14
14
Max. panel
thickness
Thread
Thread
Thread
dp
Ø x length
A
A2
[mm]
65
51
65
69
25
69
Cavity fixings
Spring toggle KD 3+4, KDH 3+4
[mm]
M 3 x 90
M 3 x 80
M 3 x 90
M 4 x 100
M 4 x 70
M 4 x 100
2
OSB- Platte1)
≥15 mm
[kN]
0,34
0,58
0,85
0,85
0,89
0,072)
0,132)
0,302)
0,452)
0,89
Spring toggle KD 3+4, KDH 3+4
2)
3)
Beinhaltet den Sicherheitsfaktor 4. Versagen des Untergrundes maßgebend.
Beinhaltet den Sicherheitsfaktor 2,25. Stahlversagen/Aufbiegen des Hakens maßgebend.
Gültig für zentrische Zuglast.
LOADS
Toggle fixing KD
Highest recommended loads3) for a single anchor.
Type
Thread size
KD3
KD4
KD5
KD6
KD8
KDH3
KDH4
KDH5
KDH6
KDH8
[M]
M3
M4
M5
M6
M8
M3
M4
M5
M6
M8
[kN]
[kN]
[kN]
0,45
0,15
0,34
0,90
0,15
0,58
2,20
0,15
0,85
2,80
0,15
0,85
4,30
0,18
0,89
0,072)
0,072)
0,072)
0,132)
0,132)
0,132)
0,302)
0,15
0,302)
0,452)
0,15
0,452)
1,40
0,18
0,89
Recommended loads in the respective base material Frec3)
Max. possible recommended load2)
Gypsum plasterboard1)
Oriented strand board1)
1)
2)
12,5 mm
≥15 mm
Includes the safety factor 4. Failure of the base material decisive.
Includes the safety factor 2.25. Steel failure/bending of the hook decisive.
http://www.fischer.de/en/ - 16/09/2014
3)
Valid for axial tensile load.
Cavity fixings
1)
3