A-V(ZN)H2Y4Y WBF 12F - Kabelovna Děčín Podmokly, sro

Breakout Cable
ID:
KABELOVNA Děčín Podmokly s.r.o.
Ústecká 840/33, 405 33 Děčín 5
Czech Republic
DIČ CZ26759993
tel.: +420 412 706 222
www.kabelovna.cz
Z273
4.12.2014
ver.2
A-V(ZN)H2Y4Y WBF 12F
This cable is suitable for outdoor use.
Black PA outer jacket
(Other colours available on request)
Waterblocking E-glass
FR-LSZH Simplex cable
Water-swellable tape
FRP dielectric central strength member (OD 2,5 mm),
PE coated (OD 5,8 mm)
Buffered optical fibre
Rip cord
Black MDPE inner jacket, UV stable
Order example
2100 m A-V(ZN)H2Y4Y 12E9/125 G.657.A1 jacket coul our BLK, ti ght buffer, ca ble specifi ca ti on Z273
Buffer
Sheat Marking
Tight
Free
strip.up to 10cm
strip.more than 100cm
Colour
Material
Natur
FR-LSZH
Print colour
Print method
Print legend
White
INK-Jet
manufacturer’s name, job number, type of cable, length
marking @ 1 m intervals
Other print legends available on request
Other buffer colours available on request.
Fibre Type
Packaging Standard put-up length
Plywood
Single mode fiber 9/125
Multi mode fiber 50/125
Multi mode fiber 62,5/125
2100 m ± 5 % *
* other lengths on request
Drum size
8F
12F
1200×640×600
1200×640×600
See the Fibre Specification sheet
KDP reserves the right to change the values ​in this document without prior notice.KDP is not responsible for any action taken pursuant to this document.
This document is property of KDP. This document or any of its parts are not alowed to be redistributed without explicit consent of KDP.
Page 1/2
Breakout Cable
ID:
KABELOVNA Děčín Podmokly s.r.o.
Ústecká 840/33, 405 33 Děčín 5
Czech Republic
DIČ CZ26759993
tel.: +420 412 706 222
www.kabelovna.cz
Z273
4.12.2014
ver.2
A-V(ZN)H2Y4Y WBF 12F
Mechanical and Environmental properties
Test
Cable outer diameter
Cable weight
Value
8F
11,6 ± 0,4
12F
13,9 ± 0,4
8F
114
12F
159
Unit
Method
mm
EN 60811-1-1
kg/km
Inner jacket thickness
1,2
mm
Outer jacket thickness
0,5
mm
Subunit diameter
2,0
mm
- calculated
Max. tensile strenghth
8F
2600
N
EN 60974-1-2-E1
Max. tensile strenghth
12F
3500
N
EN 60974-1-2-E1
2500
N
EN 60974-1-2-E3
Crush resistance test
Impact resistance test
3
Min. bend radius (no load)
Min. bend radius (load)
15
20
Temperature range
Installation
Operation
Storage
Number
of.
impact
× OD
× OD
-5 to + 50°C
-20 to + 60°C
-20 to + 60°C
Comment
EN 60974-1-2-E4
EN 60974-1-2-E11a
EN 60974-1-2-E11b
EN 60794-1-22-F1
- max. fiber strain 0,6 %
- long term 280 N
- no fiber strain for long term load
- max. attenuation variation ≤ 0,1 dB at 1550 nm
- no increase attenuation after the test
- max. fiber strain 0,6 %
- long term 550 N
- no fiber strain for long term load
- max. attenuation variation ≤ 0,1 dB at 1550 nm
- no increase attenuation after the test
- plate dimensions 100×100 mm
- max. attenuation variation ≤ 0,1 dB at 1550 nm
- duration of loading 1 min.
- no increase attenuation after the test
- impact energy 15 Nm, slightly damaged jacket
- impact energy 20 Nm, no jacket cracking
- max. attenuation variation ≤ 0,1 dB at 1550 nm
- no increase attenuation after the test
- max. attenuation variation ≤ 0,1 dB at 1550 nm
- max. attenuation variation ≤ 0,1 dB at 1550 nm
- max. attenuation variation ≤ 0,15 dB at 1550 nm
- Dwell time acc.. to EN 60794-1-22-F1.
- When installing or assembly under temperature bellow 5°C
cable has to be stock in temp of 20°C at least 24h before
installation.
- no increase attenuation after the test
Cable life time - minimum 30 years
KDP reserves the right to change the values ​in this document without prior notice.KDP is not responsible for any action taken pursuant to this document.This document is property of KDP.
This document or any of its parts are not alowed to be redistributed without explicit consent of KDP.
Page 2/2