LM00 A-D2Y HD Blown Cable max.12F (200µm)

Air Blown Microcable
ID:
LM00
KABELOVNA Děčín Podmokly s.r.o.
Ústecká 840/33, 405 33 Děčín 5
Czech Republic
DIČ CZ26759993
tel.: +420 412 706 222
www.kabelovna.cz
Z076
20.10.2014 ver.7
A-D2Y HD Blown Cable max.12F (200µm)
This cable is suitable for Air-blowing.
Green HDPE outer jacket (Grooved), UV stable
Gel filled PBT loose tube with optical fibres
The picture represents a cable with 12 fibres
Order example
2100 m A-D2Y HD Bl own Cabl e 12E9/125G.657.A1 jacket colour GRN, ca ble s peci fi ca tion Z076
Fibre colour coding
According to IEC 60304
1 Red
2 Green
Fibre
3 BlueType
4 Yellow
SMF
ITU-T G.657
5 White
SMF
ITU-T G.652.D
6 Grey
See
the Fibre Specification sheet
7 Brown
8 Violet
9 Turquoise
10 Black
11 Orange
12 Pink
Sheat Marking
Print colour
Print method
Print legend
Black
INK-Jet
manufacturer’s name, job number, type of
cable, length marking @ 1 m intervals
Other print legends available on request
Other fibre colour sequences available on request
Packaging
Fibre Type
Plywood
Standard put-up length / Drum size
2100 m
450
Single mode fiber 9/125 (G.657.A1 FLEX ZWP 200 μm)
See the Fibre Specification sheet
KDP reserves the right to change the values ​in this document without prior notice.KDP is not responsible for any action taken pursuant to this document.
This document is property of KDP. This document or any of its parts are not alowed to be redistributed without explicit consent of KDP.
Page 1/2
Air Blown Microcable
ID:
KABELOVNA Děčín Podmokly s.r.o.
Ústecká 840/33, 405 33 Děčín 5
Czech Republic
DIČ CZ26759993
tel.: +420 412 706 222
www.kabelovna.cz
Z076
20.10.2014 ver.7
A-D2Y HD Blown Cable max.12F (200µm)
Mechanical and Environmental properties
Test
Value
Unit
Method
2,5 ± 0,1
mm
EN 60811-1-1
Cable weight
5,4
kg/km
Outer jacket thickness
0,5
mm
Loose tube diameter
1,5
mm
Cable outer diameter
- calculated
Max. tensile strength
50
N
EN 60974-1-2-E1
Crush resistance test
500
N
EN 60974-1-2-E3
Impact resista nce test
3
Number
of.
impact
EN 60974-1-2-E4
Min. bend radius (no load)
10
× OD
EN 60974-1-2-E11
Moisture resistance test
Temperature range
Installation
Operation
Storage
Comment
pass
EN 60794-1-22-F5
-15 to + 50°C
-40 to + 70°C
-40 to + 70°C
EN 60794-1-22-F1
- max. fibre strain 0,8%
- long term 20N
- no fibre strain for long term load
- max. attenuation variation ≤ 0,1 dB at 1550 nm
- no increase attenuation after the test
- plate dimension 100×100 mm
- max. attenuation variation ≤ 0,05 dB at 1550 nm
- duration of loading 1 min.
- no increase attenuation after the test
- impact energy 3 Nm, slightly damaged jacket
- impact energy 5 Nm, no jacket cracking
- max. attenuation variation ≤ 0,05 dB at 1550 nm
- no increase attenuation after the test
- max. attenuation variation ≤ 0,05 dB at 1550 nm
- no increase attenuation after the test
- water height 1m
- sample length 3m
- no leakage on free sample end
- duration of test 24h
- max. attenuation variation ≤ 0,1 dB at 1550 nm
- Dwell time in max. temperature 24 hours.
- When installing or assembly under temperature bellow 5°C
cable has to be stock in temp of 20°C at least 24h before
installation.
- no increase attenuation after the test
Cable life time - minimum 30 years
KDP reserves the right to change the values ​in this document without prior notice.KDP is not responsible for any action taken pursuant to this document.
This document is property of KDP. This document or any of its parts are not alowed to be redistributed without explicit consent of KDP.
Page 2/2