TENDER SCHEDULE FOR URUMADLA : ELECTRICAL WORKS DESCRIPTION QTY UNIT RATE No. 1 MODULAR SOCKETS: a Supply and fixing of 4nos. 6A sockets with 1 no 16A switch fixed on a suitable module metal box and white front plate (Modular type) including all interconnections as required UPS power (Switch shall be fixed above the table with suitable modular front plate/box and sockets shall be fixed below the counters) 9 no b Supply and fixing of 2nos. 6A sockets with 1 no 6A switch fixed on a suitable module metal box and white front plate (Modular type) including all interconnections as required Rawpower (Switch shall be fixed above the table with suitable modular front plate/box and sockets shall be fixed below the counters) c 9 no Supply and fixing of modular RJ11 telephone sockets with suitable mounting box (Modular type) including all interconnections as required (Bm, officers,counter,reception,fo,system room) 7 no d Supply and fixing of 3nos. 16A sockets with 1 no 16A switch fixed on a suitable module metal box and white front plate (Modular type) including all interconnections as required UPS power(for the SERVER room)socket for the hub must be fixed as per the location of HUB inside the server room e Supply and fixing of 1nos. 16A socket with 1 no 16A switch fixed on a 3 module metal box and white front plate (Modular type) including all interconnections as required for locker, safe room,Record room/Stationary roomDBD DocumentExtra room, f 2 a Providing 2 meter length of flexible 3core 2.5sqmm multi core copper cable one end connected to plug top 15A and the other connected to the SB inside and a suitable hook arranngement as required for hanging the cable LIGHT & FAN POINT WIRING Point wiring with 1.5sqmm 650V grade multistranded PVC insulated copper wire in MS/PVC PIPE for lights, fans including supply & fixing of 5 amp modular switch in concealed MS switch box,front plate, 3 plate ceiling rose, and concealed circuit wiring with 3 Nos (P,N,E) 2.5sqmm. and all interconnections as required. (New wiring in banking hall as per counter layout,BM,Co system and Contractor must reuse the existing Wiring for the same location after extending the existing points as mentioned in item no 2.b) No new point wiring for Safe room,Exit,Stationary & Records,ups room ,Locker room,passage,entrance)(27 points under the scope of land lord) 5 no 4 no 4 no 38 pts b c same as above but for Extending the existing point in the hall as required for the new layout for counters,hall,cash officer room from the LDB/PDB Supply and installation of 6A modular socket with a switch in the above modular switch boards. d Same as item 2a but for call bell points including providing new buzzer for the Branch Manager cabin as required 3 UPS, RAW POWER & TEL WIRING: 13 pts 10 nos 1 nos AMOUNT a b c d Supply and wiring with 3runs of 2.5 sq.mm 1100 V grade PVC insulated multi strand copper conductor wires conforming to IS 694 (with latest amendments) in suitable size PVC CONDUIT of 2mm thick concealed in the above ducts in the floor and supply of all fixing materials and accessories, interconnections complete as required for the UPS power sockets in the single window counters and officer tables. 14 Nos. Supply and wiring with 3runs of 2.5 sq.mm 1100 V grade PVC insulated multi strand copper conductor wires conforming to IS 694 (with latest amendments) in suitable size PVC CONDUIT of 2mm thick concealed in wall/floor and supply of all fixing materials and accessories, interconnections complete as required for the raw power primary sockets 6 sets Same as above but looping with 3runs of 1.5 sq.mm 1100 V grade PVC insulated multi strand copper conductor wires conforming to IS 694 (with latest amendments) in suitable size PVC CONDUIT from the raw power secondary sockets 3 sets Wiring for the wall mounting fans from the nearest switch board with 1.5sqmm 650V grade multistranded PVC insulated copper wire in MS/PVC PIPE and all interconnections as required including the supply and fixing of 6A modular socket 3" below the false ceiling and 6A switch in the switchboard as required.(BM,System room) 15 nos e Cutting the floor to the required depth 2" and width 6" for burying the conduits for the UPS/raw power socket wiring and plastering the floor surface. 100 mtr f Supplying and laying Medium grade PVC pipe in the above ducts for the LAN/telephone cabling to the revised layout of counters 150 mtr g Supplying and laying 2 pair telphone wire in Modi make PVC casing capping / pipe for the telephone points as per the revised layout. 250 mtr h Supplying and fixing a 10 pair krone connector in a suitable box as required 1 job 4 DISTRIBUTION BOARDS Supply and installation of following size MCB distribution boards with following combination of MCBs as required a 2 +6 way MCB Double door DB for UPS sockets Incomer : 40A DP MCB &Outgoing : 10/6 A SP MCB 7 Nos. for BM, Counters, Cash officer. 1 nos 2 + 8 way MCB SINGLE door DB for UPS sockets Incomer : 32A DP MCB &Outgoing : 16/10/6A SP MCB 10 Nos. for Field officer, PBD Manager, system room 1 nos 1 nos b b 2 + 4 way MCB SINGLE door DB for UPS sockets Incomer : 63A DP MCB &Outgoing : 32 A DPMCB 4 Nos. for output ups DB c e 3 phase 6 way MCB Main DB and Rawpower VTPN Double door DB Incomer: 100A FP MCCB ,16KA &outgoing : 63A TP MCB-4 nos(LDB/PDB- 1,ATM - 1, Spare-2),63A DP MCB- 3 nos (ups-1,spare2) 3 phase 6 way AC ETPN DB Incomer: 63A FP MCB &outgoing : 20/10/16 A SP MCB's - 18 nos for Raw power and Lighting,AC for system,BM. 1 nos 1 nos g Supply and fixing of 20A DPMCB on a suitable metal box for power supply to A/C units including all interconnections as required near the proposed AC locations at 4.5 ft from the floor level.(Legrand/Siemens/L&T)(Ac for BM, System room, Cash 3 nos i Supply and fixing of 63A TPMCB on a suitable metal box for power supply to Capacitior panel near the cut out including all interconnections as required .(Legrand/Siemens/L&T) 1 nos j Supply, installation , testing and commissioning of 10KVAR APFC panel with suitable APFC relay, and suitable combination of capacitors and individual MCB controls 1 nos Note : All Capacitors shall be Delta connected and rated for 440V and of APP type The Capacitors shall be provided in the Panel itself with proper ventilation arrangements.Panel to be installed at suitable location near the meter side. 6 SITC of 125A on load Change over switch of HPL brand in suitable enclosure with provision for the service cable termination as required. 8 SUB-MAIN & AC WIRING a Wiring with 2 runs of 6Sq.mm 1100V grade PVC insulated Copper conducter multistrand wires along with one run of 2.5mm copper earth wire run in suitable size PVC CONDUIT run concealed on wall/ Ceiling etc as required.(for UPS incoming-2 ) 1 nos 30 mtr b Wiring with 2 runs of 4Sq.mm 1100V grade PVC insulated Copper conducter multistrand wires along with one run of 2.5mm copper earth wire run in suitable size 2 mm thick PVC CONDUIT run concealed on wall/ Ceiling etc as required. ( 1.5,2 Tr split ac,and 180 mtr ougoing till ups sub db)) c Wiring with 4 runs of 4Sq.mm 1100V grade PVC insulated Copper conducter multistrand wires along with one run of 2.5mm copper earth wire run in suitable size 2 mm thick PVC CONDUIT run concealed on wall/ Ceiling etc as required. ( for LDB ,) 60 mtr d Wiring with 4 runs of 6 Sq.mm 1100V grade PVC insulated Copper conducter multistrand wires along with one run of 2.5mm copper earth wire run in suitable size 2 mm thick PVC CONDUIT run concealed on wall/ Ceiling etc as required. (From Main panel to Raw power/ LDB with system and BM ac ) 120 mtr e Supply and laying of 3.5 core 35 sq.mm 1100V grade PVC insulated aluminium armoured conducter along with 2 runs of SWG8 GI earth wire run on wall/ Ceiling etc as required.(from common termination panel to capacitor ,cos, vdb anf from cos to VDB at ups room). 50 mtr f g Termination of the above cable as required with suitable glands and lugs 6 sets Supplying and laying 3 runs of 2.5Sq.mm 1100V grade PVC insulated unarmoured multistrand copper conducter cables along with one run of 12SWG GI earth wire in PVC pipes run on wall/ Ceiling etc as required. (for sign board ) 40 mtr 9 FIXTURES/FANS a Supply and Installation of Direct/Indirect recess mounted luminaire Green square ,Philps LED fixture (OR) Equivalent models in other approved makes with all inter connections and fixing arrangement as required. 7 nos Supply and Installation of 1X15W downlighter fixtures recess mounted type LED Philips or Equivalent model with all interconnections and fixing arrangement as required. 32 nos Supply and Installation of 1X28W T5 fixtures SURFACE type with all interconnections (Philips Vector) and fixing arrangement as required 14 nos b d e Supply and fixing of exhaust fan of 9" of Almonard / CG as required 3 nos f g h i j Supply and installation of 100w 4/5 step type electronic regulator in the modular switch boards as required fan Supply and fixing of hi flow model 56 inches ceiling fan CG makewith all connections and anchor fasteners ,fan hooks, down rods etc as required Supply and Fixing of wall mounted fans of CG make 400mm Hi flow model.Bm,System room. Supply, fixing 1 nos of 16 A switch socket with all modular front plate and connections for lunch room, Public Space, officer for cooler Wiring with 2 runs of 4Sq.mm 1100V grade PVC insulated Copper conducter multistrand wires along with one run of 2.5mm copper earth wire run in suitable size 2 mm thick PVC CONDUIT run concealed on wall/ Ceiling etc as required for above points 10 Earthing: a Providing Standard Copper Plate Earth Station with 600 X 600 X 3.15mm thick copper plate including construction of brick pedestal, providing meshed funnel, CI cover completly as per IS 3043-1987 or latest revision including suitable copper strip to be fixed in the UPS room for distribution. b d 4 nos 4 nos 15 nos 8 nos 120 mtr 1 nos Providing Standard GI pipe Earth Station including construction of brick pedestal, providing meshed funnel, CI cover completly as per IS 3043-1987 or latest revision including suitable copper strip to be fixed in the UPS room for distribution. 1 nos c Supply and laying of 8SWG Cu insulated Wire in 20mm dia rigid pvc conduit for ups DB earthing from the existing earth pits in PVC conduit of suitable size. 60 mtr Supply and laying of 8SWG gI insulated Wire in 20mm dia rigid pvc conduit for ups DB earthing from the existing earth pits as required in PVC conduit of suitable size. 55 mtr 11 Supply fixing of 250A/36kva FP MCCB Enclosure for the meter input from the pole for the AP TRANSCO all mounted on wooden board with neutral link of suitable capacities with all connections and hardware. 1 nos Total value of Electrical works APPROVED BRANDS WIRES MCCB TPN SFU CHANGEOVER SWITCH CABLES KITKAT MS CONDUITS LT/ RR CABLE/FINOLEX/HAVELLS/POLYCAB ABB/LT/SIEMENS/GE/MDS/CG ABB/GE/LT/CG L&T/HPL/C&S CCI/UNIVERSAL/POLYCAB/HAVELLS/RALLISON GECO/ANCHOR/KUNDAN GUPTA/BHARAT PVC CONDUITS PRECISION/SUDHAKAR METAL CLAD SOCKETS MDS SLEEK/SIEMENS/HAVELLS LIGHT FIXTURE PHILIPS/WIPRO/CG/BAJAJ/GE CFL FIXTURES PHILIPS/CG/GE/WIPRO/BAJAJ CAPACITORS L&T/ CROMPTON/ NEPTUNE DUCATI/ ASIAN CEILING/WALL FANS CROMPTON/ BAJAJ CABLE GLANDS SUNIL/HMI/BRACO/COMET CABLE LUGS DOWELL/3D HRC FUSES/BASE GE/ OR APPROVED MAKE INDICATING METERS AE/IMP/MECO/ENERCON RELAYS GE/TELEMECANIQUE/PROK DEVICES/ KAPPA/IMP/AE/KALPA CT'S RESIN-CAST SELECTOR SWITCHES L&T/SIEMENS/KAYCEE INDUSTRIAL EXHAUST FANS CROMPTON/ GEC/ARMONALD / BAJAJ CEILING/EXHAUST FANS PVC CONDUITS BUS BAR TAPING BOX M S CONDUITS CASING / CAPPING the make of materials considered in the Tender. CROMPTON / BAJAJ MODI/SUDHAKAR/VIP/PRECISION/ATUL SIEMENS/SCHNEIDER/ABB BHARAT / ZINDAL CLASSIC/ MODI
© Copyright 2024 ExpyDoc