nRM ADCX AUTOMATIC DIMMING CONTROL PHOTOCELL RECESSED MOUNT • LOW VOLTAGE SPECIFICATIONS FEATURES Automatic Daylight Harvesting Full On/Off Switching Control (optional) Communicates w/ nLight Network Remotely Configurable/Upgradeable Automatic Set-Point Calibration Push-Button Programmable Green LED Indicator PHYSICAL SPECS SIZE 4.40” (11.18 cm) Square WEIGHT 6 oz MOUNTING: Recesses into a 4” x 4” square junction box COLOR: White nLIGHT NETWORK PORTS: 2 RJ-45 ELECTRICAL SPECS POWER CONSUMPTION: ~ 3 mA WIRES: None ENVIRONMENTAL SPECS OPERATING TEMP 14º to 160º F (-10º to 71º C) RELATIVE HUMIDITY 20 to 90% non-condensing SILICONE FREE ROHS COMPLIANT SENSOR OPERATION The sensor controls the room’s lighting to achieve maximum daylight harvesting while maintaining a minimum light level referred to as the set-point. When no daylight is available, the sensor allows the controlled dimmable lighting to operate at their full bright level. As daylight increases and begins to contribute to the overall light level of the room, the Automatic Dimming Control (ADC) feature starts dimming the room proportionally, eventually reaching the full dim level (or AMPLE DAYLIGHT optionally switching off). As the daylight levels fall, the ADC feature will again take control of the lights; reducing the dim level (increasing the brightness) in order to achieve the necessary total light level. At the point when all daylight contribution is gone, lighting will be back at its full bright level. DIMMING OTHER UL and CUL Listed Title 24 System Component 5 Year Warranty Assembled in the U.S.A. OVERVIEW OPTIONS The nLight nRM ADCX Series LOW TEMP/HIGH HUMIDITY (LT) photocell sensor provides automatic • Device electronics are coated for dimming control for daylight harvesting corrosion resistance - required for applications. Ideal for spaces with cold storage or humid areas. windows, such as vestibules, corridors, • Operates down to -40º F/C classrooms, or offices, the sensor works by first monitoring daylight conditions in a room. It then signals networked nLight control devices to adjust their dimming outputs to obtain maximum energy savings while ensuring adequate lighting levels are maintained. The nRM ADCX can control nLight enabled luminaires (e.g. VTLED Family from Lithonia), or nLight dimming relay packs (e.g. nPP16 D or nSP5 PCD), or auxiliary dimming output devices (e.g. nIO D). The nRM ADCX sensor can also be used together with nLight occupancy sensors. Manual override or adjustment of the dimming level is possible via WallPod dimmers or through the SensorView software. Set-point nLIGHT OPERATION nRM family devices are native nLight devices meaning they are individually Lights Full DIM Lights Full ON addressable and digitally communicate to other nLight devices such as Wallpod AUTO DIMMING CONTROL switches, relay packs, nLight-enabled digital luminaires, and occupancy sensors. All devices are wired using CAT-5e cabling; creating a local nLight control zone. Once linked to an nLight Gateway, either directly or via an nLight network backbone, the zone becomes capable of remote status monitoring, time scheduling, configuration, and control with nLight SensorView software. ORDERING INFO MODEL NUMBERS DESCRIPTION nRM ADCX Daylight Harvesting Photocell Recessed Mount nRM ADCX LT Daylight Harvesting Photocell Recessed Mount, Low Temp Operation Revised 12.18.14 © 2014 WIRING (DO NOT WIRE HOT) T568B pin/pair assignment is recommended for all CAT-5e cables. Sensor power is provided via the CAT-5e connection to an nLight power pack/supply, nLight-enabled digital luminaire, or nLight Bridge. Wiring to an nLight Relay Pack Wiring to an nLight Enabled Luminaire nRM ADCX nRM ADCX BLU (line in) 120 VAC BLK1 (line in) OR 1 277 VAC1 ORN (line in) WHT(neutral) BLU (line out) nPP16 D or nPP16 DS CAT-5e 0-10 VDC Ballast or LED Driver CAT-5e VIO (low voltage dim out) GRY (low voltage common) GRN CAT-5e nLight Enabled Luminaire To other nLight devices (optional) To other nLight devices (optional) DEVICE SETTINGS Several operational settings for the nRM ADCX are available and configurable through the unit’s push-button and/or SensorView software, including: • Override (Full Dim/Full Bright/Normal) • Automatic Set-point Calibration Mode • Photocell Broadcasting (Enable/Disable) • Blink-back Set-point (in footcandles) • Switch Tracking (Enable/Disable) • Set-point (0-200 fc) • Photocell Broadcasting Channel (1-16) • Sunlight Discount Factor (1-8) • Switch Tracking Channel (1-16) • Occupied Bright Level (0-100%) • Photocell On/Off (Enable/Disable) • Unoccupied Dim Level (0-100%) • WallPod Dimming Adjustment (Temporary, • Dimming Rate • Photocell On/Off (Enable/Disable) • Photocell On/Off Transition Time (45 sec - 25 min) • Photocell Temporary Override, Permanant) LED Indicator (Enabled/Disable) INSTALLATION • The nRM ADCX is designed to fit inside a 4” square junction box* (min. box depth 2.125”). The sensor can also be recessed mounted in a ceiling tile. • Interconnect unit (via rear RJ-45 ports) with other nLight devices in lighting zone using CAT-5e cables. • Once power is received via CAT-5e connection, all devices in zone will automatically begin functioning together according to each device’s defaults. PUSH BUTTON *Canadian style boxes w/ two screws per mounting tab require modification. PROGRAMMING Refer to included instruction card for default settings and directions on programming the sensor via the push-button. WARRANTY 5-year limited warranty. Full warranty terms located at: www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx Note: Specifications subject to change without notice. Actual performance may differ as a result of end-user environment and application. Sheet#: TN-118-003 900 Northrop Road, Wallingford, CT 06492 • 1.800.PASSIVE • FX 203.269.9621 • www.nlightcontrols.com
© Copyright 2025 ExpyDoc