DATA SHEET RK 160 LS | 105232 RK 160 LS TECHNICAL DATASHEET • • • • • Operating Point 1 2 3 4 5 Current I A 0,5 0,5 0,6 0,6 0,6 Power Consumption P1 W 100 114 127 129 123 RPM n 1/min 2808 2726 2637 2628 2664 SPL inlet LWA5 dB(A) - - - - - SPL outlet LWA6 dB(A) - - - - - dB(A) - - - - - SPL casing break out LWA2 Backward curved centrifugal fan Plastic housing PA6, RAL 7035 Switch with 4-speed Speed controllable Integrated thermal switch RK 160 LS | 105232 Voltage UN Current Imax Ambient Temperature tA Medium Frequency Band Sound power (LW) dB(A) Σ 63 125 250 500 1k 2k 4k 8k Inlet LWA5 - - - - - - - - - Outlet LWA6 - - - - - - - - - Casing LWA2 - - - - - - - - - Medium Temperature tM Speed Control Motor Protection Isolation Class Weight 230 V 1~ 0,6 40 °C 40 °C 4-3-2-1 TAI F 3,6 kg ruck Ventilatoren GmbH | Max-Planck-Straße 5 | D-97944 Boxberg | Tel +49 7930 9211-300 | [email protected] | www.ruck.eu www.canfan.nl