EBARA UE-PRO System DIMENSION Type : 3UEP-EVM D2 D1 PHASE INDICATING LIGHT EXHAUST FAN PUMP X TPN MCCB H HYDRO BOOSTER Variable Frequency Drive RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT EMERGENCY ENTER STOP EBARA TANK SUCTION Uniquely EBARA Variable Speed Booster System 125 DISCHARGE W L VIEW `X' DIMENSION MODEL 3UEP-EVM 3 3UEP-EVM 5 3UEP-EVM 10 3UEP-EVM 18 3UEP-EVM 32 3UEP-EVM 45 3UEP-EVM 64 D1 mm 250 250 250 250 250 250 250 Type : 4UEP-EVM D2 mm 550 550 550 550 550 550 550 W mm 850 850 850 850 850 850 850 SIDE VIEW H mm 1450 1450 1450 1450 1450 1450 1450 L mm 1330 1330 1460 1700 2290 2510 2510 TANK LITER 8 8 18 18 24 24 24 SUCTION MANIFOLD (mm) 50 50 65 100 100 150 150 PIPE CONNECTION NPT NPT NPT FLANGE FLANGE FLANGE FLANGE DISCHARGE MANIFOLD (mm) 50 50 65 100 100 150 150 Custom built for ideal water supply system... APPLICATIONS • X • • TPN MCCB H Variable Frequency Drive RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT EMERGENCY ENTER STOP • TANK SUCTION • 125 DISCHARGE W L VIEW `X' • SIDE VIEW MODEL D1 mm D2 mm W mm H mm L mm 4UEP-EVM 3 250 600 850 1450 1680 4UEP-EVM 5 250 600 850 1450 4UEP-EVM 10 250 600 850 1450 4UEP-EVM 18 250 600 850 4UEP-EVM 32 250 600 850 4UEP-EVM 45 250 600 4UEP-EVM 64 250 600 Water supply for villa, school, hotel, hospital, rest house and high-rise buildings. Industrial water boosting. SUCTION DISCHARGE TANK LITER MANIFOLD (mm) MANIFOLD (mm) PIPE CONNECTION 8 65 65 1680 8 65 65 NPT 1850 18 80 80 FLANGE 1450 2140 18 100 100 FLANGE 1450 2730 24 150 150 FLANGE 850 1450 3060 24 200 200 FLANGE 850 1450 3060 24 200 200 FLANGE Municipal water supply. Irrigation NPT • Constant Pressure PID controller with inverter able to adjust water pressure perfectly by variable speed control. Energy saving Using of the inverter able to save energy. No water hammering Preventing water hammer as speed is adjusted automatically to meet variable demand. Fully tested & assembled unit Ensure trouble-free operation. Stainless steel pumpset used Hygience and clean water assured. Ebara TOTAL warranty on all components used Value for money. * Dimensional details are provided for reference only. * All specifications are subject to change without prior notice. EBARA Pumps Malaysia Sdn Bhd • • FEATURES EXHAUST FAN HYDRO BOOSTER Type UE-PRO • D1 D2 PHASE INDICATING LIGHT DIMENSION System Authorised dealer: 6, Jalan TP3, UEP Subang Jaya Industrial Park, 47620 Subang Jaya, Selangor, Malaysia. Tel : 03-8023 6622 Fax : 03-8023 9355 Email : [email protected] Website : www.ebara.com.my Micro Processor Controller type UE-PRO EPM UE-PRO 0514 EBARA UE-PRO System PERFORMANCE CURVE EBARA AC Power Control Signal UE PRO EVMG 3, 5, 10, 18, 32, 45, 64 350 300 UE P RO E 250 UE VMG O M G PR Pressure Output (Control) 32 18 O EV VMG PR O M 10 3 64 M2 INV M3 - Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code. INV - Dry running prevention, high & low pressure limit protection, pipe friction loss compensation, automatically lead lag (Step 1 & Step 2) during emergency and schedule (Daily, Weekly & Monthly) operation function. M4 * Up To 4 Inverter Pump System Input Signal & Type of Sensor 50 • Constant Pressure control installation: - Industrial pressure transmitter with 0 to 20mA, 4 to 20mA (0 – 30V supply voltage) or/ 0 – 10 VDC input signal. 0 10 20 30 40 50 60 70 80 100 120 140 160 180 m3/hr SPECIFICATIONS • • • INV EV MG G 5 VMG UE 100 0 M1 EV MG EV INV 45 PR PR UE RO E RO E 150 UE O UE P UE P 200 • UE-PRO (Multi Inverter type) System - Booster unit incorporated with multiple pumps with integral or/ external inverter up to 4 pumps parallel in operation and capable to adjust the water pressure automatically to meets actual system demand at all time. Model : UE-PRO (Multiple Inverter Type) UE PRO EVMG 3, 5, 10, 18, 32, 45, 64 CURVES 2 POLES 50 Hz m UE-PRO System Multi-inverter control (2-4 pump system) Temperature or pressure control (PID) Input 415 V, 3 Ph, 50Hz • Option: - Float less Relay control for Tank to Tank pumping application DIMENSION Type : 2UEP-EVM D1 D2 SYSTEM OPERATION DIAGRAM EXHAUST FAN PHASE INDICATING LIGHT X Operation Functional Features Control Signal INV M1 M2 M3 Pressure Output (Control) * Up To 4 Pump System M4 • UE-PRO (Single Inverter) System - Booster unit incorporated with 1 single integral or/ external inverter driven pump and 3 fix speed pump up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time. TPN MCCB HYDRO BOOSTER Variable Frequency Drive RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT EMERGENCY ENTER STOP TANK - Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code - Dry running prevention, high & low pressure limit protection, pipe friction loss compensation, automatically lead lag (Step 1 & Step 2) emergency and schedule operation (Daily, Weekly & Monthly) function. H AC Power SUCTION DISCHARGE 125 Model : UE-PRO (Single Inverter Type) DIMENSION W L VIEW `X' SIDE VIEW H mm L mm TANK LITER SUCTION MANIFOLD (mm) DISCHARGE MANIFOLD (mm) PIPE CONNECTION 850 1450 970 8 50 50 NPT 850 1450 970 8 50 50 NPT 550 850 1450 1070 18 65 65 NPT 550 850 1450 1260 18 80 80 FLANGE 250 550 850 1450 1260 24 100 100 FLANGE 250 550 850 1450 1405 24 150 150 FLANGE 250 550 850 1450 1405 24 150 150 FLANGE MODEL D1 mm D2 mm W mm 2UEP-EVM 3 250 550 2UEP-EVM 5 250 550 2UEP-EVM 10 250 2UEP-EVM 18 250 2UEP-EVM 32 2UEP-EVM 45 2UEP-EVM 64 EBARA UE-PRO System PERFORMANCE CURVE EBARA AC Power Control Signal UE PRO EVMG 3, 5, 10, 18, 32, 45, 64 350 300 UE P RO E 250 UE VMG O M G PR Pressure Output (Control) 32 18 O EV VMG PR O M 10 3 64 M2 INV M3 - Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code. INV - Dry running prevention, high & low pressure limit protection, pipe friction loss compensation, automatically lead lag (Step 1 & Step 2) during emergency and schedule (Daily, Weekly & Monthly) operation function. M4 * Up To 4 Inverter Pump System Input Signal & Type of Sensor 50 • Constant Pressure control installation: - Industrial pressure transmitter with 0 to 20mA, 4 to 20mA (0 – 30V supply voltage) or/ 0 – 10 VDC input signal. 0 10 20 30 40 50 60 70 80 100 120 140 160 180 m3/hr SPECIFICATIONS • • • INV EV MG G 5 VMG UE 100 0 M1 EV MG EV INV 45 PR PR UE RO E RO E 150 UE O UE P UE P 200 • UE-PRO (Multi Inverter type) System - Booster unit incorporated with multiple pumps with integral or/ external inverter up to 4 pumps parallel in operation and capable to adjust the water pressure automatically to meets actual system demand at all time. Model : UE-PRO (Multiple Inverter Type) UE PRO EVMG 3, 5, 10, 18, 32, 45, 64 CURVES 2 POLES 50 Hz m UE-PRO System Multi-inverter control (2-4 pump system) Temperature or pressure control (PID) Input 415 V, 3 Ph, 50Hz • Option: - Float less Relay control for Tank to Tank pumping application DIMENSION Type : 2UEP-EVM D1 D2 SYSTEM OPERATION DIAGRAM EXHAUST FAN PHASE INDICATING LIGHT X Operation Functional Features Control Signal INV M1 M2 M3 Pressure Output (Control) * Up To 4 Pump System M4 • UE-PRO (Single Inverter) System - Booster unit incorporated with 1 single integral or/ external inverter driven pump and 3 fix speed pump up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time. TPN MCCB HYDRO BOOSTER Variable Frequency Drive RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT EMERGENCY ENTER STOP TANK - Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code - Dry running prevention, high & low pressure limit protection, pipe friction loss compensation, automatically lead lag (Step 1 & Step 2) emergency and schedule operation (Daily, Weekly & Monthly) function. H AC Power SUCTION DISCHARGE 125 Model : UE-PRO (Single Inverter Type) DIMENSION W L VIEW `X' SIDE VIEW H mm L mm TANK LITER SUCTION MANIFOLD (mm) DISCHARGE MANIFOLD (mm) PIPE CONNECTION 850 1450 970 8 50 50 NPT 850 1450 970 8 50 50 NPT 550 850 1450 1070 18 65 65 NPT 550 850 1450 1260 18 80 80 FLANGE 250 550 850 1450 1260 24 100 100 FLANGE 250 550 850 1450 1405 24 150 150 FLANGE 250 550 850 1450 1405 24 150 150 FLANGE MODEL D1 mm D2 mm W mm 2UEP-EVM 3 250 550 2UEP-EVM 5 250 550 2UEP-EVM 10 250 2UEP-EVM 18 250 2UEP-EVM 32 2UEP-EVM 45 2UEP-EVM 64 EBARA UE-PRO System DIMENSION Type : 3UEP-EVM D2 D1 PHASE INDICATING LIGHT EXHAUST FAN PUMP X TPN MCCB H HYDRO BOOSTER Variable Frequency Drive RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT EMERGENCY EBARA ENTER STOP TANK SUCTION Uniquely EBARA Variable Speed Booster System 125 DISCHARGE W L VIEW `X' DIMENSION MODEL 3UEP-EVM 3 3UEP-EVM 5 3UEP-EVM 10 3UEP-EVM 18 3UEP-EVM 32 3UEP-EVM 45 3UEP-EVM 64 D1 mm 250 250 250 250 250 250 250 Type : 4UEP-EVM D2 mm 550 550 550 550 550 550 550 W mm 850 850 850 850 850 850 850 SIDE VIEW H mm 1450 1450 1450 1450 1450 1450 1450 L mm 1330 1330 1460 1700 2290 2510 2510 TANK LITER 8 8 18 18 24 24 24 SUCTION MANIFOLD (mm) 50 50 65 100 100 150 150 PIPE CONNECTION NPT NPT NPT FLANGE FLANGE FLANGE FLANGE DISCHARGE MANIFOLD (mm) 50 50 65 100 100 150 150 Custom built for ideal water supply system... APPLICATIONS • X • • TPN MCCB H Variable Frequency Drive RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT Variable Frequency Drive EMERGENCY ENTER STOP RUN STOP RUN MODE FAULT EMERGENCY ENTER STOP • TANK SUCTION • 125 DISCHARGE W L VIEW `X' SIDE VIEW D1 mm D2 mm W mm H mm L mm 4UEP-EVM 3 250 600 850 1450 1680 4UEP-EVM 5 250 600 850 1450 4UEP-EVM 10 250 600 850 1450 4UEP-EVM 18 250 600 850 4UEP-EVM 32 250 600 850 4UEP-EVM 45 250 600 4UEP-EVM 64 250 600 MODEL Water supply for villa, school, hotel, hospital, rest house and highrise buildings. Industrial water boosting. SUCTION DISCHARGE TANK LITER MANIFOLD (mm) MANIFOLD (mm) PIPE CONNECTION 8 65 65 1680 8 65 65 NPT 1850 18 80 80 FLANGE 1450 2140 18 100 100 FLANGE 1450 2730 24 150 150 FLANGE 850 1450 3060 24 200 200 FLANGE 850 1450 3060 24 200 200 FLANGE Municipal water supply. Irrigation NPT • • Constant Pressure PID controller with inverter able to adjust water pressure perfectly by variable speed control. Energy saving Using of the inverter able to save energy. No water hammering Preventing water hammer as speed is adjusted automatically to meet variable demand. Fully tested & assembled unit Ensure trouble-free operation. Stainless steel pumpset used Hygience and clean water assured. Ebara TOTAL warranty on all components used Value for money. * Dimensional details are provided for reference only. * All specifications are subject to change without prior notice. EBARA Pumps Malaysia Sdn Bhd • • FEATURES EXHAUST FAN HYDRO BOOSTER Type UE-PRO • D1 D2 PHASE INDICATING LIGHT DIMENSION System Authorised dealer: 6, Jalan TP3, UEP Subang Jaya Industrial Park, 47620 Subang Jaya, Selangor, Malaysia. Tel : 03-8023 6622 Fax : 03-8023 9355 Email : [email protected] Website : www.ebara.com.my Micro Processor Controller type UE-PRO EPM UE-PRO 0514
© Copyright 2025 ExpyDoc