STYCAST 1090 SI (BE) Two Component, Low Density, Epoxy Encapsulant (BE, Manufactured in Belgium) Product Description : STYCAST 1090 SI has lower density (0,65) and higher compressive strength than STYCAST 1090. Because STYCAST 1090 SI has a low dielectric constant, it will have a minimum effect on electronic circuit operation. The filler will tend to float during storage. Premixing before use is required. Applications : STYCAST 1090 SI is recommended for applications where high compressive stress is applied to encapsulated circuitry - as in deep ocean work. STYCAST 1090 SI shows negligible deformation and water absorption in these applications. It should be considered where the ultimate in performance is demanded. Instructions For Use : 1.Mixed with CATALYST 24 LV : 1.1. Mix STYCAST 1090 SI thoroughly in the can in which it is received. 1.2. Weigh out the quantity required. Add 23 parts of CATALYST 24 LV per 100 parts of STYCAST 1090 SI by weight. Mix thoroughly. Liquid diluents can be supplied to lower viscosity at some sacrifice in properties. Pot life of the catalysed resin at room temperature is about 30 minutes. 1.3. Pour into mould or cavity. MOULD RELEASE 122 S will prevent adhesion. (Evacuation may be necessary to remove trapped air and is recommended for high quality embedments. It is often convenient to remove the trapped air from the resin prior to pouring into mould, and then again evacuate briefly when the mould is filled). 1.4. Allow to stand at room temperature for about 4 hours. Remove from the mould is possible prior to that time if the casting is hard. Cure is fully completed at room temperature within 24 hours. 2. Mixed with CATALYST 9 : 2.1. Mix STYCAST 1090 SI thoroughly in the can in which it is received. 2.2. Weigh out the quantity required. Add 11 parts of CATALYST 9 per 100 parts of STYCAST 1090 SI by weight. Mix thoroughly. Liquid diluents can be supplied to lower viscosity at some sacrifice in properties. Pot life of the catalyzed resin at room temperature is about 30 minutes. 2.3. Pour into mold or cavity. MOULD RELEASE 122 S will prevent adhesion. (Evacuation may be necessary to remove trapped air and is recommended for high quality embedments. It is often convenient to remove the trapped air from the resin prior to pouring into mould, and then again evacuate briefly when the mould is filled). 2.4. Allow to stand at room temperature for about 4 hours. Remove from the mould is possible prior tothat time if the casting is hard. Cure is fully completed at room temperature within 24 hours. A post cure of 4 hours at 60 - 100°C will improve the end properties of the resin. Note : If smallest dimension of casting is more than 5 cm, use CATALYST 11 instead of CATALYST 24 LV. Use 12 parts CATALYST 11 per 100 parts STYCAST 1090 SI. Cure for 16 hours at 80°C. PROTECTING YOUR ELECTRONICS. Properties Of Material As Supplied : Property Test Method Unit STYCAST 1090 SI Chemistry Appearance Density Viscosity at 25°C Visual ASTM-D-792 ASTM-D-2393 g/cm3 Pa.s 0,60 - 0,70 30 - 50 Value With CATALYST 24 LV epoxy black 2,0 - 3,5 With CATALYST 9 0,70 - 0,80 5- 10 Cure Schedule : Please refer to the instructions for use above. Properties Of Material After Application : Property Test Method Unit STYCAST 1090 SI Hardness Glass Transition Temperature Compressive Strength Elastic Modulus, Compressive Flexural Strength Tensile Strength Thermal Conductivity Coefficient Of Linear Thermal Expansion Volume Resistivity Value With CATALYST 24 LV Shore D °C With CATALYST 9 75 minimum 50 - 60 ASTM-D-695 MPa 65 minimum ASTM-D-695 ASTM-D-790 ASTM-D-638 MPa MPa MPa 28 minimum 15 minimum 20 minimum ASTM-D-2214 W/m.K 0,17 0,13 - 0,18 ASTM-D-3386 10-6 K-1 5,4 50 - 65 ASTM-D-257 Ohm.cm 1013 minimum 1013 minimum ASTM-D-2240 ASTM-D-3386 2000 minimum The information given and the recommendations made herein are based on our research and are believed to be accurate but no guarantee of their accuracy is made. In every case we urge and recommend that purchasers before using any product in full scale production make their own tests to determine to their own satisfaction whether the product is of acceptable quality and is suitable for their particular purposes under their own operating conditions. THE PRODUCTS DISCUSSED HEREIN ARE SOLD WITHOUT ANY WARRANTY AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY OTHER WARRANTY, EXPRESSED OR IMPLIED . No representative of ours has any authority to waive or change the foregoing provisions but, subject to such provisions, our engineers are available to assist purchasers in adapting our products to their needs and to the circumstances prevailing in their business. Nothing contained herein shall be construed to imply the non-existence of any relevant patents or to constitute a permission, inducement or recommendation to practice any invention covered by any patent, without the authority from the owner of this patent. © 1997 Henkel STYCAST 1090 SI Two Component, Low Density, Epoxy Encapsulant Properties Material After Application (Continued) : Property Test Method Unit STYCAST 1090 SI Dielectric Constant Dissipation Factor Dielectric Strength Moisture Absorption In 24 h Service Temperature Value With CATALYST 24 LV With CATALYST 9 3,7 3,1 2,3 2,9 2,7 2,3 0,025 0,02 0,03 ASTM-D-150 at 60 Hz at 1 KHz at 1 MHz ASTM-D-150 at 60 Hz at 1 KHz at 1 MHz ASTM-D-149 kV/mm 0,02 0,01 0,01 14,7 minimum ASTM-D-570 % 0,4 maximum ASTM-D-794 °C -70 to +100 -70 to +125 Storage And Handling : Store STYCAST 1090 SI in sealed unopened containers at temperatures between 18°C and 25°C. Health & Safety : It is recommended to consult the Henkelproduct literature, including material safety datasheets, prior to using Henkel products.These may be obtained from your local sales office. (STYCAST is a registered trademark of Henkel) E22/03/99-MVRRVH (1004s) Storage Temperature (°C) 18 to 25 Usable Shelf Life 1 year Attention Specification Writers : The technical information contained herein is consistent with the properties of the material and should not be used in the preparation of specifications, as it is intended for reference only. For assistance in preparing specifications, please contact your local Henkel office fordetails. Please contact Henkel QualityAssurance for test method details. UK Distributors HITEK Electronic Materials 15 Wentworth Road Scunthorpe DN17 2AX www.hitek-ltd.co.uk tel +44 (0) 1724 851678 fax+44 (0) 1724 280586 PROTECTING YOUR ELECTRONICS.
© Copyright 2024 ExpyDoc