Enjoy your Smart Life! - korea eureka day 2014

26-28 May 2014 Oslo, NORWAY
Top in Digital Environment
Enjoy your Smart Life!
Contents
1.TIDE Introduction
2.TIDE AMI system
3. Activities related AMI system
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
Top in Digital Environment
1.1 Company profile
26-28 May 2014 Oslo, NORWAY
• Y2014 – Development of City gas management AMI server(KT Corp.)
• Y2013 Apr. – AMI system field test completion in KEPCO style
May – AMI field test completion in Uzbekistan style
– Sales PLC modem to Jamaica vendor(continuous export)
Aug. ~ Dec. Selected as ‘Expansion into metropolitan areas’ business execution company sponsored by Kore
a Smart Grid Institute
Sep. – Conclusion of a product supply contract about “Low voltage AMI system & PLC modem” with KT Corp.
– Sales start of PLC modem to Jamaica
Dec. – Subterranean lined AMI system field test completion at KEPCO’s test site
• Y2012 –Low voltage AMI system for a house development & Applying to ‘Low Voltage AMI project’ bidding ordered
by KEPCO
• Y2011 Aug. – Development of PLC system for streetlamp
Oct. - Development completion of 500Mbps PLC modem
• Y2010 May ~ Sep. - Development of wireless power transfer system for mobile phone(W/TG Sambo)
June - Development completion of 200Mbps PLC modem
• Y2009 - Sales Y cable PLC sample to the KT R&D center
• Y2008 – Sales PLC 200Mbps sample to the KT R&D center
– Sales PLC module to the LCD test equipment vendor
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
1.2 Business Area of TIDE
□ Tide has developed and provided industrial PLC products to various industries, and has been cooperating with KEPCO
(Korea Electric Power Corporation / Government Company) for Advanced Metering Infrastructure.
Tide has developed and provided “Power saving system”, “Smart Urban Lighting system” and “Information & communication
infrastructures” for Gas Compensation System .
Power Line Communication based AMI
Urban Lighting Solutions
Power
line (PLC)
Distribution box
Power
line (PLC)
LED Projector / Power Saving System
City Gas Compensation system
Consumer
Management
office
WI-FI
Target Power
(Contract demand)
Internet
6:00
Security
device
Security
device
Top in Digital Environment
Security
device
Program Control
Power
Sensor
Gas
Volume
meter Cable
compensator
Local
wireless
Predictable Energy Pattern
CSG management
system
9:00
12:00
15:00
18:00
Time
26-28 May 2014 Oslo, NORWAY
1.3 Smart grid Market Trend in Europe
□ Smart grid market demand in the Europe is expected to increase
environmental factors
due to
Smart Grid Forecast in Europe 2012-2016
• It makes concentrate effort to use
PLC as high-speed access network
because a dense power lines and
lack of supply for ADSL
• There is many old stone buildings
and
it’s
difficult
to
install
communication lines. So PLC-AMI
market potential demand is high
• Start the OPERA(Open PLC European
Research Alliance) project in 2008
• By 2016, GTM Research forecasts
€6.8 billion per year in smart grid
investment in Europe
Source: GTM Research, AUGUST 16, 2011
Top in Digital Environment
5
26-28 May 2014 Oslo, NORWAY
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
2.1 TIDE AMI system
PLC AMI Configuration -1
Method
Pres.
Optical
Futu.
CDMA
DCU
Changeable PLC type
due to the meter type
B-CDMA
D-TRS
① or ②
① Standard Meter
② E-type Meter
PLC modem
+
Laptop
B-CDMA
Inspection
or
PLC Module
※ Bidding with KT Consortium for KEPCO PLC-AMI Project (AMI system is made by Tide)
※ Export PLC module to Jamaica Planning to export AMI total package to the all over the world
※ We are AMI system maker ,and with multi chip vendors (Qualcomm / Echelon / Loenk/Korean type )
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
2.1 TIDE AMI system
PLC AMI Configuration -2
FEP Server
Data collection from DCU
Seamless Data
Sending data to EMS
DCU
EMS Server
Saving metered Data
Control and Monitor
Metering System
Providing Various
Service
Billing
Server
Customer
DCU
Web Server
DCU
FEP Server
EMS Server
Usage Statistics
Method
DCU
Now
Cable
Future
Optical
KEPCO
Server
※ AMI Total Solution Provider
※ Tide develops and produces all Software and Hardware, so we can customize all kinds of sites and projects
※ Interoperable Qualcomm / Echelon AMI system with EMS server using KEPCO protocol
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
2.1 TIDE AMI system
PLC AMI Configuration -3
Lab test
DCU
BRIDGE
E-TYPE
MODEM
G TYPE Meter
(w/ Modem)
Top in Digital Environment
Meter
26-28 May 2014 Oslo, NORWAY
2.2 AMI PLC Chip Specification
POWER CHAMP
K2 24E_1M
Model
Operating
Freq.
Modulation
Chip
Power
Specification
Consumpti
on
PHY Speed
CPU
QUALCOMM Home Plug AV
AR7400
QUALCOMM Green PHY
QCA7000
ECHELON
PL31XX
2~23MHz
2~68MHz
2~30MHz
132Khz~115Khz
OFDM
OFDM
OFDM
Dual-Carrier Frequency,BPSK
2W
30W
Below 2W
Below 1.8W
24Mbps
500Mbps
4~10Mbps
5.4Kbps
ARM9(MAC/PHY)
ARM9(MAC/PHY)
ARM9(MAC/PHY)
Neuron Core(DSP)AD/DA
Home Plug Green PHY(HPGP)
IEEE1901
OSGP/LonWorks
CENELEC EN50065-1
1~2km coverage distance
AFE tuning & Exclusive chip u Ensure stable communicatio
AFE(analog front end) tuni
High speed data transmission
se(Stabilizing)
n unrelated noise
ng AGC tuning possible
Operating oversea system
Performance dependent on
Hard to handling big capaci
Ethernet TCP/IP only
AMI data only
AFE circuit tuning
ty data
Verified low speed PLC tech
Unstable ADC/DAC part
Performance remain accordin
nology
Meet Europe standard
Unstable AGC circuit
g to stabilizing AFE part
High percentage of complet
ion
Standard
ISO12139-1
Advantage
Weakness
Remark
Home Plug AV
*AFE : Analog Front End/ SOGP : Open Smart Grid Protocol/ AGC : AUTO GAIN CONTROL
-
 QCA7000 is the World First Standard HomePlug Green PHY Solution supporting:
Power save modes reducing energy consumption by 80% or more vs. HomePlug AV
Robust OFDM (ROBO) modulation – robust extended home coverage
IP based applications and networks
Throughput to meet today’s needs providing scalability to protect your investment for tomorrows requirements
QCA7000 is designed for low cost, low power embedded applications
-
Single standard CMOS based SoC
Integrated Power Management Unit, Analog Front End, and Memory
SPI and UART host interfaces to low cost and low power Microcontrollers
GPIO’s and dedicated serial Flash interface for simple ‘host-less’ applications
QCA7000 is supported with a full HDK & SDK to enable customer’s quick time to market
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
2.3 Products
G-type / E-type Meter-modem
G-Type PLC module (Internal type)
E-Type modem (External type)
Vs.
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
2.3 Products
DCU : Data Concentrator unit
DCU receives and saves metered data through power line communication from meter and PLC modem, sends data when
receive a FEP request.
DCU consists of DCU, TDU, Power supply, CT Probe and enclosure.
CPU and Memory
Image
Specification
CPU Atmel AT915AM9G20B
Memory 64MByte : Two SDRM 32Mbyte (Volatile Memory)
Memory 256MByte : NAND Flash (NonVolatile Memory)
Memory 8MByte : Non Flash (NonVolatile Memory)
OS(Operating System)
Embedded Linux Ver 2.6.27 Porting
CPU Specification
Voltage : 1.0V Internal CPU Core. 3.3V I/O Memory
CPU Frequency 400MHz
Communications Interface
Serial Interface
Console `-7.5.896
DIGITAL – TRS
TR Monitoring Port
BCDMA Console Port
BCDMA Master Port
Ethernet Interface
PLC Master Port
WAN
LAN
Modem
Top in Digital Environment
USB 2.0 Dual ON.chip Transceiver
2.3 Products
Bridge
To repeat data from modem to DCU
Deliver data from modem to DCU through coaxial cable
Image
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
2.3 Products
26-28 May 2014 Oslo, NORWAY
3 phase Probe unit
This CT Probe Unit is used to sense voltage and current and connected to the power supply of transformer
To measure voltage and current from secondary line of pole transformer
Ratio of Transformation is 2500:1
3 phase Probe lead line shall be made from recyclable material, separated as R/S/T/N four line, insulation strength above
220V, longer than 8m
Sensing part connected to secondary line of transformer shall be less 90(W) X 80(H) X 30(D) mm
Image
Top in Digital Environment
2.3 Products
26-28 May 2014 Oslo, NORWAY
BCDMA modem (Console & Master)
Master binary CDMA RF modem is to read data from installed slave binary CDMA
Console Slave binary CDMA RF Modem is to communicate with emulator Console master modem to check and control
DCU on the spot
Image
Top in Digital Environment
2.3 Products
DCU Emulator Software
DCU software to monitoring electricity usage of each households
Changeable DCU configuration and controllable the PLC modem and electric meters
Image
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
26-28 May 2014 Oslo, NORWAY
2.3 Products
Front End Processor Server
FEP is designed to control mainframe. One side of FEP Server is connected to DCU and the other side is connected to
the EMS Server, E implementing sending and receiving of message, assembly and disassembly of packet, error detection
and calibration
Possible to manage DCU one thousand in maximum, and forwarding data collected by DCU after error detection to the
EMS Server regularly
Image
CPU and Memory
Above Intel Xeon 2.6Ghz
8G DDR3 ECC Memory
SATA 500G*2 HDD
Windows Server 2012 standard Edition
MySQL DBMs
1Gigabit Ethernet 2 port
Dual Power system
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
2.3 Products
Energy Management System Server
Integrated Monitoring Server, saving data in DBMS received from FEP Server, real time monitoring and controlling system
real time billing inquiry and expected power consumption analysis based on collected data
Providing Billing Service from interoperability with Billing Server
CPU and Memory
Image
Above Intel Xeon 3.6Ghz
16G DDR3 ECC Memory
SAS 500G*4 HDD
Windows Server 2012 standard Edition
Oracle DBMS 11G standard editon
1Gigabit ethernet 2 port
Dual Power system
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
3.1 AMI system construction in site
13’ ~14’
‘Expansion into metropolitan areas’ business execution company sponsored by Korea Smart Grid Institute
Electrical wiring system(per building)
Customer
DCU install work
Coupler Install
=
DCU install work
Meter change work
Installed DCU
Installed Meters
Entire wiring
system map
EMS server
(IDC center)
DVR
D
D
D
관
D
M
D
D
D
D
Internet
lining
Communicatio
n unit(/2 build.)
Common
Utility tunnel
(Basement)
D
D
D
D
Top in Digital Environment
Control
office(MDMS)
3.2 AMI monitoring screenshot
26-28 May 2014 Oslo, NORWAY
For home user (Computer screen)
For AMI system administrator
(Computer screen)
For home user (Mobile phone screen)
Bi-directional confirmation can be done at the same time
Our system provide two type of monitoring method (computer
or Mobile phone)
Top in Digital Environment
26-28 May 2014 Oslo, NORWAY
3.3 AMI system Benefits
Electric power
control / Direct
operation
Quantified
customer
benefits
Economic
feasibility
• Real-time monitoring of electricity usage data
• Electric power generation control in electric station;
Possible of Demand Response(DR)
• Improvement in outage management efficiency
• Enhanced customer service
• Billing accuracy improvement
• Reduced consumption on inactive meters
• New internet network install cost saving
• Operational efficiencies in billing & customer management
• Environmental preservation through reduced peak-time
usage
Top in Digital Environment
Top in Digital Environment
Thanks!
Hee Yeoun Jeon, CEO
E-mail : [email protected]
9F Kapeul Great Valley A-dong Digitalro 8-ghil 32, Geumcheon-gu, Seoul, Korea