26-28 May 2014 Oslo, NORWAY Top in Digital Environment Enjoy your Smart Life! Contents 1.TIDE Introduction 2.TIDE AMI system 3. Activities related AMI system Top in Digital Environment 26-28 May 2014 Oslo, NORWAY Top in Digital Environment 1.1 Company profile 26-28 May 2014 Oslo, NORWAY • Y2014 – Development of City gas management AMI server(KT Corp.) • Y2013 Apr. – AMI system field test completion in KEPCO style May – AMI field test completion in Uzbekistan style – Sales PLC modem to Jamaica vendor(continuous export) Aug. ~ Dec. Selected as ‘Expansion into metropolitan areas’ business execution company sponsored by Kore a Smart Grid Institute Sep. – Conclusion of a product supply contract about “Low voltage AMI system & PLC modem” with KT Corp. – Sales start of PLC modem to Jamaica Dec. – Subterranean lined AMI system field test completion at KEPCO’s test site • Y2012 –Low voltage AMI system for a house development & Applying to ‘Low Voltage AMI project’ bidding ordered by KEPCO • Y2011 Aug. – Development of PLC system for streetlamp Oct. - Development completion of 500Mbps PLC modem • Y2010 May ~ Sep. - Development of wireless power transfer system for mobile phone(W/TG Sambo) June - Development completion of 200Mbps PLC modem • Y2009 - Sales Y cable PLC sample to the KT R&D center • Y2008 – Sales PLC 200Mbps sample to the KT R&D center – Sales PLC module to the LCD test equipment vendor Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 1.2 Business Area of TIDE □ Tide has developed and provided industrial PLC products to various industries, and has been cooperating with KEPCO (Korea Electric Power Corporation / Government Company) for Advanced Metering Infrastructure. Tide has developed and provided “Power saving system”, “Smart Urban Lighting system” and “Information & communication infrastructures” for Gas Compensation System . Power Line Communication based AMI Urban Lighting Solutions Power line (PLC) Distribution box Power line (PLC) LED Projector / Power Saving System City Gas Compensation system Consumer Management office WI-FI Target Power (Contract demand) Internet 6:00 Security device Security device Top in Digital Environment Security device Program Control Power Sensor Gas Volume meter Cable compensator Local wireless Predictable Energy Pattern CSG management system 9:00 12:00 15:00 18:00 Time 26-28 May 2014 Oslo, NORWAY 1.3 Smart grid Market Trend in Europe □ Smart grid market demand in the Europe is expected to increase environmental factors due to Smart Grid Forecast in Europe 2012-2016 • It makes concentrate effort to use PLC as high-speed access network because a dense power lines and lack of supply for ADSL • There is many old stone buildings and it’s difficult to install communication lines. So PLC-AMI market potential demand is high • Start the OPERA(Open PLC European Research Alliance) project in 2008 • By 2016, GTM Research forecasts €6.8 billion per year in smart grid investment in Europe Source: GTM Research, AUGUST 16, 2011 Top in Digital Environment 5 26-28 May 2014 Oslo, NORWAY Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 2.1 TIDE AMI system PLC AMI Configuration -1 Method Pres. Optical Futu. CDMA DCU Changeable PLC type due to the meter type B-CDMA D-TRS ① or ② ① Standard Meter ② E-type Meter PLC modem + Laptop B-CDMA Inspection or PLC Module ※ Bidding with KT Consortium for KEPCO PLC-AMI Project (AMI system is made by Tide) ※ Export PLC module to Jamaica Planning to export AMI total package to the all over the world ※ We are AMI system maker ,and with multi chip vendors (Qualcomm / Echelon / Loenk/Korean type ) Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 2.1 TIDE AMI system PLC AMI Configuration -2 FEP Server Data collection from DCU Seamless Data Sending data to EMS DCU EMS Server Saving metered Data Control and Monitor Metering System Providing Various Service Billing Server Customer DCU Web Server DCU FEP Server EMS Server Usage Statistics Method DCU Now Cable Future Optical KEPCO Server ※ AMI Total Solution Provider ※ Tide develops and produces all Software and Hardware, so we can customize all kinds of sites and projects ※ Interoperable Qualcomm / Echelon AMI system with EMS server using KEPCO protocol Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 2.1 TIDE AMI system PLC AMI Configuration -3 Lab test DCU BRIDGE E-TYPE MODEM G TYPE Meter (w/ Modem) Top in Digital Environment Meter 26-28 May 2014 Oslo, NORWAY 2.2 AMI PLC Chip Specification POWER CHAMP K2 24E_1M Model Operating Freq. Modulation Chip Power Specification Consumpti on PHY Speed CPU QUALCOMM Home Plug AV AR7400 QUALCOMM Green PHY QCA7000 ECHELON PL31XX 2~23MHz 2~68MHz 2~30MHz 132Khz~115Khz OFDM OFDM OFDM Dual-Carrier Frequency,BPSK 2W 30W Below 2W Below 1.8W 24Mbps 500Mbps 4~10Mbps 5.4Kbps ARM9(MAC/PHY) ARM9(MAC/PHY) ARM9(MAC/PHY) Neuron Core(DSP)AD/DA Home Plug Green PHY(HPGP) IEEE1901 OSGP/LonWorks CENELEC EN50065-1 1~2km coverage distance AFE tuning & Exclusive chip u Ensure stable communicatio AFE(analog front end) tuni High speed data transmission se(Stabilizing) n unrelated noise ng AGC tuning possible Operating oversea system Performance dependent on Hard to handling big capaci Ethernet TCP/IP only AMI data only AFE circuit tuning ty data Verified low speed PLC tech Unstable ADC/DAC part Performance remain accordin nology Meet Europe standard Unstable AGC circuit g to stabilizing AFE part High percentage of complet ion Standard ISO12139-1 Advantage Weakness Remark Home Plug AV *AFE : Analog Front End/ SOGP : Open Smart Grid Protocol/ AGC : AUTO GAIN CONTROL - QCA7000 is the World First Standard HomePlug Green PHY Solution supporting: Power save modes reducing energy consumption by 80% or more vs. HomePlug AV Robust OFDM (ROBO) modulation – robust extended home coverage IP based applications and networks Throughput to meet today’s needs providing scalability to protect your investment for tomorrows requirements QCA7000 is designed for low cost, low power embedded applications - Single standard CMOS based SoC Integrated Power Management Unit, Analog Front End, and Memory SPI and UART host interfaces to low cost and low power Microcontrollers GPIO’s and dedicated serial Flash interface for simple ‘host-less’ applications QCA7000 is supported with a full HDK & SDK to enable customer’s quick time to market Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 2.3 Products G-type / E-type Meter-modem G-Type PLC module (Internal type) E-Type modem (External type) Vs. Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 2.3 Products DCU : Data Concentrator unit DCU receives and saves metered data through power line communication from meter and PLC modem, sends data when receive a FEP request. DCU consists of DCU, TDU, Power supply, CT Probe and enclosure. CPU and Memory Image Specification CPU Atmel AT915AM9G20B Memory 64MByte : Two SDRM 32Mbyte (Volatile Memory) Memory 256MByte : NAND Flash (NonVolatile Memory) Memory 8MByte : Non Flash (NonVolatile Memory) OS(Operating System) Embedded Linux Ver 2.6.27 Porting CPU Specification Voltage : 1.0V Internal CPU Core. 3.3V I/O Memory CPU Frequency 400MHz Communications Interface Serial Interface Console `-7.5.896 DIGITAL – TRS TR Monitoring Port BCDMA Console Port BCDMA Master Port Ethernet Interface PLC Master Port WAN LAN Modem Top in Digital Environment USB 2.0 Dual ON.chip Transceiver 2.3 Products Bridge To repeat data from modem to DCU Deliver data from modem to DCU through coaxial cable Image Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 2.3 Products 26-28 May 2014 Oslo, NORWAY 3 phase Probe unit This CT Probe Unit is used to sense voltage and current and connected to the power supply of transformer To measure voltage and current from secondary line of pole transformer Ratio of Transformation is 2500:1 3 phase Probe lead line shall be made from recyclable material, separated as R/S/T/N four line, insulation strength above 220V, longer than 8m Sensing part connected to secondary line of transformer shall be less 90(W) X 80(H) X 30(D) mm Image Top in Digital Environment 2.3 Products 26-28 May 2014 Oslo, NORWAY BCDMA modem (Console & Master) Master binary CDMA RF modem is to read data from installed slave binary CDMA Console Slave binary CDMA RF Modem is to communicate with emulator Console master modem to check and control DCU on the spot Image Top in Digital Environment 2.3 Products DCU Emulator Software DCU software to monitoring electricity usage of each households Changeable DCU configuration and controllable the PLC modem and electric meters Image Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 26-28 May 2014 Oslo, NORWAY 2.3 Products Front End Processor Server FEP is designed to control mainframe. One side of FEP Server is connected to DCU and the other side is connected to the EMS Server, E implementing sending and receiving of message, assembly and disassembly of packet, error detection and calibration Possible to manage DCU one thousand in maximum, and forwarding data collected by DCU after error detection to the EMS Server regularly Image CPU and Memory Above Intel Xeon 2.6Ghz 8G DDR3 ECC Memory SATA 500G*2 HDD Windows Server 2012 standard Edition MySQL DBMs 1Gigabit Ethernet 2 port Dual Power system Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 2.3 Products Energy Management System Server Integrated Monitoring Server, saving data in DBMS received from FEP Server, real time monitoring and controlling system real time billing inquiry and expected power consumption analysis based on collected data Providing Billing Service from interoperability with Billing Server CPU and Memory Image Above Intel Xeon 3.6Ghz 16G DDR3 ECC Memory SAS 500G*4 HDD Windows Server 2012 standard Edition Oracle DBMS 11G standard editon 1Gigabit ethernet 2 port Dual Power system Top in Digital Environment 26-28 May 2014 Oslo, NORWAY Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 3.1 AMI system construction in site 13’ ~14’ ‘Expansion into metropolitan areas’ business execution company sponsored by Korea Smart Grid Institute Electrical wiring system(per building) Customer DCU install work Coupler Install = DCU install work Meter change work Installed DCU Installed Meters Entire wiring system map EMS server (IDC center) DVR D D D 관 D M D D D D Internet lining Communicatio n unit(/2 build.) Common Utility tunnel (Basement) D D D D Top in Digital Environment Control office(MDMS) 3.2 AMI monitoring screenshot 26-28 May 2014 Oslo, NORWAY For home user (Computer screen) For AMI system administrator (Computer screen) For home user (Mobile phone screen) Bi-directional confirmation can be done at the same time Our system provide two type of monitoring method (computer or Mobile phone) Top in Digital Environment 26-28 May 2014 Oslo, NORWAY 3.3 AMI system Benefits Electric power control / Direct operation Quantified customer benefits Economic feasibility • Real-time monitoring of electricity usage data • Electric power generation control in electric station; Possible of Demand Response(DR) • Improvement in outage management efficiency • Enhanced customer service • Billing accuracy improvement • Reduced consumption on inactive meters • New internet network install cost saving • Operational efficiencies in billing & customer management • Environmental preservation through reduced peak-time usage Top in Digital Environment Top in Digital Environment Thanks! Hee Yeoun Jeon, CEO E-mail : [email protected] 9F Kapeul Great Valley A-dong Digitalro 8-ghil 32, Geumcheon-gu, Seoul, Korea
© Copyright 2025 ExpyDoc