ALD M EASU RI NG FOR RETROFIT 1.) SELECT EXISTI NG FIXTU RE TO M EASU RE AN D OPEN ACCESS/GLASS DOOR PAN EL: DIAM ETER” 2.) M EASU RE I NSIDE EDGE-TO-EDGE DIM ENSIONS OF ACTUAL GLASS ( IF GLASS IS ROU N D, M EASU RE DIAM ETER): LENGTH” WIDTH” 3.) PROVIDE TH ESE LENGTH & WIDTH DIM ENSIONS ON YOU R SIM PLYLEDS P.O. : PG. 1 SIM PLYLEDS 3 3 1 3 B R O W N S T R E ET , G A R D E N C I T Y , I D 8 3 7 1 4 208.344.7533 M AT T H E W . D E R E N @ S I M P L Y L E D S . C O M ALD M EASU RI NG FOR RETROFIT 1.) SH UT OFF BREAKER AT PAN EL: 2.) REMOVE CONTENTS FROM FIXTU RE, I.E., GLASS, LAM PS, BALLAST, REFLECTOR, ETC. (RECYCLE OR DISPOSE ACCORDI NG TO LOCAL CODE): RETAI N CLIPS FOR RE-USE I N STEP 3. MOU NT DRIVER TO BOX USI NG EXISTI NG TAPPED HOLES & SECU RE WITH PLUMBER’S TAPE IF N ECESSARY 3.) I NSTALL TH E LED DRIVER I NSIDE BOX & ALD U N IT I N PLACE OF GLASS: PG. 2 SIM PLYLEDS 3 3 1 3 B R O W N S T R E ET , G A R D E N C I T Y , I D 8 3 7 1 4 208.344.7533 M AT T H E W . D E R E N @ S I M P L Y L E D S . C O M ALD M EASU RI NG FOR RETROFIT WARNING ! ! FAILURE TO FOLLOW THESE WARNINGS AND ASSEMBLY INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH. RISK OF FIRE OR ELECTRICAL SHOCK: Ÿ Do not alter, relocate, or remove wiring, LED lamp holders, power supply, or any other electrical component. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. Ÿ Installation of this retrofit assembly requires a person familiar with the construction and operation of the luminaire’s electrical system and the hazard involved. If not qualified, do not attempt installation. Contact a qualified electrician. Ÿ Unless otherwise indicated, do not make or alter any openings in the compartment of wiring or electrical components during installation of this retrofit assembly. Plug all unused openings in the compartment of wiring or electrical components. Ÿ To prevent wiring damage or abrasion, Do not expose wiring to edges of sheet metal or other sharp objects. Ÿ Luminaire’s wiring, power supply, or other electrical parts may be damaged when drilling for installation of retrofit assembly hardware. Inspect wiring and components for damage Ÿ Replace with only SimplyLEDs driver, LEDs, or other parts as applicable. Ÿ Do not use when enclosure is broken. SimplyLEDs, Inc. 208.344.7533 SimplyLEDs.com Copyright 2012, SimplyLEDs, Inc. SIM PLYLEDS 3 3 1 3 B R O W N S T R E ET , G A R D E N C I T Y , I D 8 3 7 1 4 PG. 3 208.344.7533 M AT T H E W . D E R E N @ S I M P L Y L E D S . C O M
© Copyright 2024 ExpyDoc