rchitectural Products illing BAL 29 Western Red Cedar bushfire resisting exterior cladding fully tested in accordance with AS3959:2009 to comply with BAL29 requirements. This product is available in raw only and cannot be coated without re-testing. Av ai No lab w le F co or e nt nq ac u t y irie ou s r l abo oc u al t Re thi pr s p es ro en d ta uct tiv , e. Created by nature, improved by man, limited only by your imagination! Bushfire Resisting Cladding - Western Red Cedar BAL 29 Fire Resisting Timber To find out more phone: 1800 33 77 03 or visit www.tilling.com.au Western Red Cedar bushfire resisting exterior cladding fully tested in accordance with AS3959:2009 to comply with BAL29 requirements. rchitectural Products This product is available in raw only and cannot be coated without re-testing. illing Our new Bushfire Resisting Exterior Cladding is treated, tested and approved for use in areas rated up to and including BAL29. The treatment is effective for the whole service life of the cedar cladding because the fire retardant is impregnated within the timber making it leach resistant. AS3959:2009 Bushfire Attack Level standard has been designed to improve the fire resisting performance of buildings when subject to bushfire attack. The impact the standard has had on material selection for construction in bushfire prone areas has been far-reaching. The cladding can be docked to the required length without affecting the efficacy of the fire treatment (Sealing the docked ends with a waterproof sealer is still recommended as best building practice). AS3959-2009 contains construction solutions for all bushfire attack levels (BAL). Bushfire attack levels include: BAL-LOW, 12.5, 19, 29, 40 & FZ. The number after the BAL is a measure of the heat flux exposure threshold in kW/m2. This product has been weathered in a lab, post treatment of fire retardant, and passes AS3959:2009. As such it can be used in external exposed applications. All of this information is contained on the fire test certificate. There is currently only one profile and it is unique to our range and for this product only. We do not, at this stage, offer any other profiles or finishes. However, due to the unpredictable nature and behaviour of fire combined with the extreme weather conditions experienced in Australia, ultimately, no guarantee can be provided that a building will survive in the event of a bushfire. Many timbers, such as Western Red Cedar, are traditionally used in these bush areas because of their natural beauty, can now no longer be used in the higher rated BAL areas. Very important: This product is sold as raw only. Adding coatings, such as stains and oils etc…, to the product will alter the composition and the product it will require re-testing. This can be achieved, however at considerable cost in terms of time and money. Untreated Western Red Cedar can be used as an external cladding in BAL-12.5 & lower without restriction and can still be used as an external cladding in BAL-19 except for within 400mm of the ground but not in higher rated areas. Vapour membrane Fire Resisting Flooring Anodised aluminium sections to complete the cladding system. WRC BAL29 CV127CFT fire resisting boards. Horizontal or verticle application Joist Bearer Concrete stump 25 mm Wall must be clad with CV127CFT boards or Fibre Cement not less than 6mm thick and not less than 400mm above finished ground level 25 mm 52 mm 30 mm Ground External Y corner External box corner 127 6 6 25 mm 25 mm 9.5 17.5 6 Product Code: CV127CFT 7 5 25 mm 25 mm Internal aluminium box corner End stop 11 To find out more phone: 1800 33 77 03 or visit www.tilling.com.au
© Copyright 2024 ExpyDoc