MILLIMETRES 100 (c) Crown copyright and database rights 2013 Ordnance Survey 100023205 L REFER ARCHITECTS INFORMATION FOR ALL LEGISLATIVE, SPATIAL, DIMENSIONAL AND MATERIAL DESIGN ELEMENTS. THIS DRAWING MUST BE READ IN CONJUNCTION WITH SUPPLEMENTARY STRUCTURAL, CIVIL, MECHANICAL AND ELECTRICAL INFORMATION. FOR DESIGN INFORMATION RELATIVE TO LOADINGS (WIND LOADS, APPLIED LOADS, DEAD LOADS, IMPACT LOADS) REFER SUPPLEMENTARY ENGINEERING INFORMATION IN CONJUNCTION WITH ENGINEERS PROPOSED METHOD OF FIXING. FOR DESIGN INFORMATION RELATIVE TO STRUCTURAL DEPTHS, GAUGES ETC REFER ENGINEERS DRAWINGS. FOR DESIGN INFORMATION RELATING TO FIXINGS OR CONNECTIONS BETWEEN DESIGN ELEMENTS (BOLTED, SCREWED, WELDED OR CHEMICALLY BONDED REFER SUPPLEMENTARY ENGINEERING INFORMATION. RRAP ACCESS POINT THIS DRAWING HAS BEEN ISSUED IN DRAFT FORM FOR COMMENT AND COST DEVELOPMENT PURPOSES. DO NOT SCALE FROM THIS DRAWING. ALL MEASUREMENTS ARE IN METRIC UNLESS STATED OTHERWISE. DO NOT BUILD FROM THIS DRAWING. IN ADDITION TO THE HAZARDS/RISKS NORMALLY ASSOCIATED WITH THE TYPES OF WORK DETAILED ON THIS DRAWING, NOTE THE FOLLOWING SIGNIFICANT RESIDUAL RISKS :- ITEM HAZARD RISK MO TORC YCLE S B General revision to landscaping, waste compound added QD SEP/13 JD A PLANNING QD APR/13 JD RMG REV DESCRIPTION BY DATE SD CHK'D AUTH Atkins Limited 200 Broomielaw Glasgow G1 4RU Scotland Telephone +44(0)141 220 2000 Fax +44(0)141 220 2001 CLIENT: PROJECT: CAMBRIDGE SCIENCE PARK STATION INTERCHANGE TITLE: PROPOSED LOCATION PLAN SCALE: 1:2000 ORIGINAL SIZE: DESIGNED: A0 ATKINS OFFICE: DATE: GLA PROJECT NO: QD DATE: 16/11/12 DISCIPLINE: TYPE: 5110967 A DRAWN: L CHECKED: JD DATE: 16/11/12 CODE: 16/11/12 DRG NO: 00 P03 AUTHORISED: SD DATE: 16/11/12 REV: B REV: GENERAL NOTE DRG NO: IT IS ASSUMED THAT ALL WORKS WILL BE CARRIED OUT BY A COMPETENT CONTRACTOR WORKING, WHERE APPROPRIATE, TO AN APPROVED METHOD STATEMENT B DISMANTLING / DEMOLITION (FUTURE) P03 FOR INFORMATION RELATING TO USE CLEAINING AND MAINTENANCE SEE THE H&S FILE CODE: 00 CONSTRUCTION DISCIPLINE: TYPE: A SAFETY, HEALTH AND ENVIRONMENTAL INFORMATION IN ADDITION TO THE HAZARDS NORMALLY ASSOCIATED WITH THE TYPES OF WORK DETAILED ON THIS DRAWING, NOTE THE FOLLOWING RISKS AND INFORMATION : PROJECT NO: 10 5110967 0 5040023/CGB/SL/D/001 A NOTES: 1. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH DRAWING SHEET 2 5040023/CGB/SL/D/002 AND PROPOSED SCHEMATIC 5040023/CGB/SL/D/004, AND CHESTERTON SPUR MAINTENANCE TRACK LIGHTING SPECIFICATION APPENDICES. 2. A BS5489:2013 LIGHTING CLASS OF P5 WITH S/P RATIO APPLIED HAS BEEN AGREED WITH THE CAMBRIDGESHIRE COUNTY COUNCIL LIGHTING ENGINEER FOR USE AS THE DESIGN LIGHT LEVEL KEY PROPOSED 6M GALVANISED STEEL TUBULAR COLUMN WITH POST TOP MOUNTED WRTL MINI LUMA LANTERNS OF TYPE R4 12LED CW MOUNTED WITH 0 DEGREE TILT HAVING A LUMINOUS FLUX OF 1.4Klm TO BE DIMMED AS STATED WITHIN APPENDICES DOCUMENT REFERENCED IN NOTE 1 PROPOSED DUCT CHAMBER PROPOSED 100mm PVC DUCT ROUTE PROPOSED MINI FEEDER PILLAR DO NOT SCALE C PROPOSED LANTERN DESIGN POINTS 100 Why this number of Lanterns? - This layout is needed to achieve the British Standards lighting level and uniformity requirements. Why use an 6m mounting height? - For the light level required this provides the most efficient design while being less intrusive than an 8m solution and also reduces light spill. What measures have been taken to reduce lighting pollution? A full cut off lantern has been specified which produces no upward light and reduces Sky Glow, spill light has has been reduced to a minimum by: Using the most efficient lantern optic and technology Designing the scheme with zero degree lantern inclination A1 0 10 SAFETY, HEALTH AND ENVIRONMENTAL INFORMATION Cambridgeshire Highways C FP1 CAMBRIDGE GUIDED BUS MAINTENANCE TRACK LIGHTING CHESTERTON SPUR PROPOSED LIGHTING AND ELECTRICAL LAYOUT SHEET 1 OF 2 1:500 C 27/02/14 27/02/14 5040023/CGB/SL/D/001 27/02/14 A 5040023/CGB/SL/D/002 A NOTES: 1. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH DRAWING SHEET 1 5040023/CGB/SL/D/001 AND PROPOSED SCHEMATIC 5040023/CGB/SL/D/004, AND CHESTERTON SPUR MAINTENANCE TRACK LIGHTING SPECIFICATION APPENDICES. 2. A BS5489:2013 LIGHTING CLASS OF P5 WITH S/P RATIO APPLIED HAS BEEN AGREED WITH THE CAMBRIDGESHIRE COUNTY COUNCIL LIGHTING ENGINEER FOR USE AS THE DESIGN LIGHT LEVEL KEY PROPOSED 6M GALVANISED STEEL TUBULAR COLUMN WITH POST TOP MOUNTED WRTL MINI LUMA LANTERNS OF TYPE R4 12LED CW MOUNTED WITH 0 DEGREE TILT HAVING A LUMINOUS FLUX OF 1.4Klm TO BE DIMMED AS STATED WITHIN APPENDICES DOCUMENT REFERENCED IN NOTE 1 EXISTING LIGHTING COLUMN TO BE RELOCATED PROPOSED DUCT CHAMBER PROPOSED 100mm PVC DUCT ROUTE PROPOSED MINI FEEDER PILLAR DO NOT SCALE C PROPOSED LANTERN DESIGN POINTS 100 Why this number of Lanterns? - This layout is needed to achieve the British Standards lighting level and uniformity requirements. Why use an 6m mounting height? - For the light level required this provides the most efficient design while being less intrusive than an 8m solution and also reduces light spill. What measures have been taken to reduce lighting pollution? A full cut off lantern has been specified which produces no upward light and reduces Sky Glow, spill light has has been reduced to a minimum by: Using the most efficient lantern optic and technology Designing the scheme with zero degree lantern inclination A1 0 10 SAFETY, HEALTH AND ENVIRONMENTAL INFORMATION Cambridgeshire Highways C 1 FP CAMBRIDGE GUIDED BUS MAINTENANCE TRACK LIGHTING CHESTERTON SPUR PROPOSED LIGHTING AND ELECTRICAL LAYOUT SHEET 2 OF 2 1:500 C 27/02/14 27/02/14 5040023/CGB/SL/D/002 27/02/14 A 5040023/CGB/SL/D/005 A NOTES: 1. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH MILTON JUNCTION LIGHTING SPECIFICATION APPENDICES. 2. A BS5489:2013 LIGHTING CLASS OF CE1 HAS BEEN AGREED WITH THE CAMBRIDGESHIRE COUNTY COUNCIL LIGHTING ENGINEER FOR USE AS THE DESIGN LIGHT LEVEL KEY PROPOSED 12M GALVANISED STEEL TUBULAR COLUMN WITH POST TOP MOUNTED URBIS ZX3 FLAT GLASS LANTERNS OF TYPE ZX3/FG/1289/105/-45/892241 WITH 250W SON/T + LAMP AND INTEGRAL ELECTRONIC CONTROL GEAR MOUNTED WITH 5 DEGREE TILT HAVING A LUMINOUS FLUX OF 33.2Klm EXISTING 12M STEEL COLUMN WITH POST TOP MOUNTED URBIS ZX3 FLAT GLASS LANTERN WITH 250W SON/T + LAMP EXISTING 12M STEEL COLUMN WITH 1M OUTREACH BRACKET AND URBIS ZX3 FLAT GLASS LANTERN WITH 250W SON/T + LAMP C EXISTING FEEDER PILLAR PROPOSED 600mm x 600mm DUCT CHAMBER EXISTING DUCT CHAMBER EXISTING DUCT ROUTE DO NOT SCALE PROPOSED 100mm STREET LIGHTING DUCT ROUTE 100 PROPOSED EARTH ELECTRODE SAFETY, HEALTH AND ENVIRONMENTAL INFORMATION P1 A1 0 10 E/F SCHEMATIC Cambridgeshire Highways C CABLE TYPE: EXISTING FEEDER PILLAR 1 CIRCUIT 6 SPARE CIRCUIT 5 20A BS88 FUSE CIRCUIT 4 20A BS88 FUSE FEEDING EXISTING EQUIPMENT CIRCUIT 3 20A BS88 FUSE CAMBRIDGE GUIDED BUS MAINTENANCE TRACK LIGHTING FEEDING EXISTING EQUIPMENT CIRCUIT 2 20A BS88 FUSE MILTON JUNCTION PROPOSED LIGHTING, ELECTRICAL AND SCHEMATIC LAYOUT FEEDING EXISTING EQUIPMENT CIRCUIT 1 20A BS88 FUSE FEEDING EXISTING EQUIPMENT 1:250 C 12/03/14 12/03/14 5040023/CGB/SL/D/005 12/03/14 A 5040023/CGB/SL/D/006 A NOTES: 1. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH PROPOSED SCHEMATIC 5040023/CGB/SL/D/007, AND MILTON JUNCTION LIGHTING SPECIFICATION APPENDICES. 2. A BS5489:2013 LIGHTING CLASS OF P5 WITH S/P RATIO APPLIED HAS BEEN AGREED WITH THE CAMBRIDGESHIRE COUNTY COUNCIL LIGHTING ENGINEER FOR USE AS THE DESIGN LIGHT LEVEL 3. THE SUBWAY HAS BEEN DESIGNED TO BS5489:2013 AS PER TABLE 4 MAINTAINED LIGHTING LEVELS FOR SUBWAYS, FOOTBRIDGES, STAIRWAYS AND RAMPS AS AN ENCLOSED SUBWAY NIGHT TIME AVERAGE ILLUMINANCE OF 100 LUX AND MIN ILLUMINANCE OF 50 LUX. 4. FEEDER PILLAR FP4 TO REPLACE EXISTING FEEDER PILLAR IN SAME LOCATION WITH TRANSFERRED DNO SUPPLY 5. TO 1A E F XIS AN T D ING 2A U F NI T S 6. C KEY PROPOSED 6M MIDHINGED GALVANISED STEEL TUBULAR COLUMN WITH POST TOP MOUNTED WRTL MINI LUMA LANTERN OF TYPE R4 12LED CW MOUNTED WITH 0 DEGREE TILT HAVING A LUMINOUS FLUX OF 1.4Klm TO BE DIMMED AS STATED WITHIN APPENDICES DOCUMENT REFERENCED IN NOTE 1 EXISTING 5M STEEL COLUMN WITH POST TOP MOUNTED URBIS ZXU1 LANTERN WITH 50W SON/T + LAMP PROPOSED 6M MIDHINGED FLANGE MOUNTED GALVANISED STEEL TUBULAR COLUMN WITH POST TOP MOUNTED WRTL MINI LUMA LANTERN OF TYPE R4 12LED CW MOUNTED WITH 0 DEGREE TILT HAVING A LUMINOUS FLUX OF 1.4Klm TO BE DIMMED AS STATED WITHIN APPENDICES DOCUMENT REFERENCED IN NOTE 1 PROPOSED SIMMONSIGNS CORNICE SAFEWAY LIGHTING UNIT COMPLETE WITH 55W COMPACT PL-L LAMP WITH LUMINOUS FLUX OF 4.8Klm. UNITS TO BE UNSWITCHED. POWER SUPPLY TO LIGHTING UNITS AT OPPOSITE SIDE OF THE SUBWAY TO BE IDENTIFIED BY CONTRACTOR AND CONNECTED TO FEEDER PILLAR SB/FP CIRCUIT 3 AS PER SCHEMATIC DRAWING REFERENCED IN NOTE 1 PROPOSED 600mm x 600mm DUCT CHAMBER PROPOSED 100mm PVC DUCT ROUTE HINGED COLUMN 4AF TO BE FLANGE MOUNTED ON CONCRETE PARAPET. FLANGE PLATE AND FOUNDATION TO BE DESIGNED BY CONTRACTOR/ATKINS IN COOPERATION WITH COLUMN MANUFACTURER PROPOSED FEEDER PILLAR OR ISOLATING PILLAR PROPOSED 6mm 3 CORE CABLE ROUTE EXISTING SPEED CAMERA 100 SE E NO TE 5 DO NOT SCALE EXISTING ILLUMINATED SIGN SAFETY, HEALTH AND ENVIRONMENTAL INFORMATION 0 10 D LI UCT G SE H IN E TIN G T IN G O SE V S T IA UB SB W /F AY P SB/FP 2400 A1 SUBWAY ENTRANCE VIEW Cambridgeshire Highways 4520 C 4520 PLAN VIEW CAMBRIDGE GUIDED BUS MAINTENANCE TRACK LIGHTING FP4 ES1 16000 ESC1 MILTON JUNCTION SUBWAY AND APPROACH PROPOSED LIGHTING AND ELECTRICAL LAYOUT 1:250 SCALE 1:50 C 13/03/14 13/03/14 5040023/CGB/SL/D/006 13/03/14 A
© Copyright 2024 ExpyDoc