DMA 160L2 - dutchi.dk

DMA 160L2
440V
General data
Electrical data
Rated motor power
Rated motor speed
Rated motor frequency
Rated motor voltage(+/-10%)
Rated motor torque
Rated motor current
Starting motor current
Starting motor torque
Breakdown motor torque
Efficiency
160
Kw
-
-1
min 50Hz
Mounting
3530
-1
min 60Hz
Weight
60
Hz
-
VD/50Hz
Protection
IP
-
VY/50Hz
Insulation class/Temperature rise
F
440
VD/60Hz
Tropicalization
760
VY/60Hz
Vibration class
N
60.1
Nm (Mn)
Duty
S1
B3/B5/B35
92
Casing material
29.67
VD/60Hz
A (ln)
Direction of rotation
17.15
VY/60Hz
A (ln)
Method of cooling
Kg
Aluminum
55
/
B
Yes
Bidirectional
IC
411
xln
Cable entry
2-M32x1,5+1-M16x1,5
2
xMn
Standards
IEC/DIN/ISO/VDE/EN
2.2
xMn
Execute at Standard
7.5
Starting
Efficiency class
Frame size
18.5
D.O.L.
IE1
IEC 60034-1
Feet removable
Paintwork
Yes
RAL
7031
grey
50Hz
60Hz
-
90
100% load
-
-
75% load
Site conditions
-
-
50% load
Ambient temperature
-
0.91
100% load
Altitude above sea level
LpA
75
dB(A)
Bearing DE side
6309-2RS-C3
LwA
84
dB(A)
Bearing NDE side
6209-2RS-C3
from -20‚C to +40‚C
1000 m
Mechanical data
Noise level
Moment of inertia
Bearings type
Lubricants for bearings
-
Kgmƒ
Average bearing lifetime
40000
h
NSK
Relubrication interval L1 DE bearing
-
h
Relubrication interval L1 NDE bearing
-
h
Compensation ring
NDE SIDE
standard
See installation and maintenance
Dutchi Denmark A/S - Hopballevej 60 - 7100 Vejle - Denmark