Application The EFD-637-MD-PH extruded aluminum penthouse is engineered and tested to withstand extreme loads, debris impact and cyclic failure associated with the severe weather effects of hurricanes (Miami-Dade County approval #050725.05). Designed for intake and exhaust applications, the EFD-637-MD-PH frequently serves as a gravity ventilator, fan discharge cap, fresh air intake cap, sight shield or pressure relief ventilator. Standard Construction Material: Mill finish 6063-T5 extruded aluminum. model EFD-637-MD-PH extruded aluminum penthouse 6" deep • 371/2° horizontal blade Miami Dade County Approved - Ratings Louver Free Area (per side): [48" ¥ 48" (1222 ¥ 1222) unit]: 9.5 ft2 (0.88 m2) 59.4% Performance @ Beginning Point of Water Penetration Free Area Velocity: 990 fpm (5.03 m/s) Air Volume Delivered: 9,405 cfm (4.44 m3/s) Pressure Loss: 0.11 in.wg. (27 Pa) Velocity @ 0.15 in.wg. Pressure Loss: 1150 fpm (5.84 m/s) Miami Dade County: NOA No. 11-0119.23 (Expires 12/29/2015) Approved to FBC TAS202-94, TAS201-94, and TAS-203-94. Frame: 6" deep ¥ 0.125" thick (152 ¥ 3.2) channel. Blades: 371/2° ¥ 0.081" (2.0) thick horizontal style. Corner: Boxed. Roof: 2" (51) thick, expanded foam board laminated and sandwiched between double skins of 0.081" (2) thick aluminum — raised seam type. Florida Building Code Approval: No. FL12655 Design Load: 80 psf Screen: 1/2" ¥ 0.063" (12.7 ¥ 1.6) expanded and flattened aluminum. Mullion: Visible. Minimum Size: 12" ¥ 12" (305 ¥ 305), 12" (305) high Maximum Size: Factory assembled: 100" ¥ 88" (2540 ¥ 2235) Maximum height: 60" (1524) H Options H o Factory finish: o High Performance Fluoropolymer - 100% resin Newlar®/ 70% resin Kynar® o Baked Enamel o Clear or Color Anodized, Class 1 o Prime Coat Side 2 o Hinged Roof. Side 1 o Alternate bird or insect screens. Model EFD-637-MD-PH (standard) o Insulated or non-insulated blank-off panels. o Sill flashing. Side 2 Dimension of Base Angle (Curb I.D. Inside to Inside) H Overall Width [Curb I.D. + 16-1/2" (419)] Side 1 Louver Dimension [Curb I.D. + 4" (102)] D Side 2 Extruded Aluminum Penthouse EFD637-MD-PH July 2014 o Filter racks. 2" (51) Base Angle 2" (51) Base Angle Side 1 Dimension of Base Angle (Curb I.D. Inside to Inside) Overall Width [Curb I.D. + 16-1/2" (419)] Overall Width [Curb I.D. + 16-1/2" (419)] Louver Dimension [Curb I.D. + 4" (102)] Side View Louver Dimension [Curb I.D. + 4" (102)] Section View Note: EFD-637-MD-PH must be installed in accordance with specific installation instructions - contact factory for details. Information is subject to change without notice or obligation. POTTORFF ® 5101 Blue Mound Road, Fort Worth, Texas 76106 NOTE: Dimensions in parentheses ( ) are millimeters. www.pottorff.com
© Copyright 2024 ExpyDoc