model VFD-10D-A 11/2 hour • dynamic rated — fire damper curtain style blade Application The VFD-10D-A fire damper employs curtain style blades for pointof-origin control of fire in static and dynamic HVAC systems. The VFD-10D-A is qualified to 4,000 ft/min (20.3 m/s) and 4 in.wg. (1.0 kPa) and may be installed in vertical walls or partitions, or horizontally in floors or assemblies with fire resistance ratings up to 2 hours. Standard Construction Frame: 22 gauge (0.85) galvanized steel. UL HNLJ.V-5: Ventilation Duct Assemblies *** Maximum Dynamic Closure Velocity: 4,000 fpm (20.3 m/s) 2,000 fpm (10.2 m/s) Maximum UL555S Rated Pressure: 4 in.wg. (1.0 kPa) UL 555 listing: R11767 TIN I SOF CALIFO G CSFM listing: 3225-0368:101 L ST S Installation: o Vertical Mount Velocity Rating: o 2000 fpm 5/8" (16) Std. o 4000 fpm Curtain Dampers VFD10DA (1/2) June 2014 o Duct access door factory mounted in common sleeve. o Generic mullion for oversized masonry or concrete openings. o Type-304 stainless steel construction. Oval Transitions Round Transitions W* H* D 12" (305) Std. (optional) (standard-vertical) Sleeve Style ISAR (optional) 2"(51) Std. W * Damper dimensions furnished approximately 1/4" (6) undersize. † Damper dimensions furnished approximately 1/8" (3) undersize. Model VFD-10D-A (standard-horizontal) Style AO (optional) W Information is subject to change without notice or obligation. POTTORFF ® Model VFD-10D-A 3" (76) Std. 12" Sleeve Style ISA 12" (305) Std. 5101 Blue Mound Road, Fort Worth, Texas 76106 (305) Std. (optional) 11" 3/4" 2"(51) Std. W 2"(51) Std. 4-1/2" (114) Std. (Standard with W and H equal to damper width and height dimensions. Available with W and H smaller than damper width and height) (Standard with D=W=H. Available with D<W and H) Style AR L Meets Building Code Standards: IBC, NBC, NFPA, SBC and UBC o Horizontal Mount o Factory installed sleeve: o Integral Gauge: o 20 (1.0) o 18 (1.3) o 16 (1.6) o 14 (2.0) o 10 (3.5) Length: o 12" (305) o 16" (406) o 24" (610) o Other ___ o Low leakage taped joints. (Integral sleeve required) o Transitions: o Flanged (sleeve required) o Round o Oval o Duct connections (sleeve required): o 1" (25) S-clip o DM-25 o DM-35 o S & Drive o WARD o Retaining angle systems: Gauge: o 20 (1.0) o 16 (1.6) Picture frame: o SSPF (single-side) o DSPF (2-side) Individual angle sets: o SS (single-side) o DS (2-side) o Alternate fire closure temperature. o 212°F (100°C) 2"(51) Std. D E MA Meets NFPA Standards: 90A, 92A, 92B and 101 Stainless Steel: Single section: Vertical: 36" ¥ 36" (914 ¥ 914) Options H RS R VI C F IR AL E A New York City MEA listing: 295-98-E A ST Maximum Size: Single section: Vertical: 36" ¥ 48" (914 ¥ 1219) Horizontal: 36" ¥ 36" (914 ¥ 914) Multiple Section: Vertical: 72" ¥ 48" (1829 ¥ 1219) 36" ¥ 96" (914 ¥ 2438) Horizontal: 36" ¥ 36" (914 ¥ 914) 72" ¥ 18" (1829 ¥ 457) R NI 6" ¥ 6" (152 ¥ 152) E AT TE E Fire Closure Device: Fusible link. Minimum Size: UL 555 Fire Resistance Rating: 11/2 hour (vertical and horizontal) Listings Blades: 24 gauge (0.7) galvanized steel – curtain style. Fire Closure Temperature: 165°F (75°C). Ratings (279) Std. (19) Std. Sleeve Style ISAF (optional) with standard flange (Typical for use with grille.) ***4000 fpm (20.3 m/s) limited to: Sleeve Style ISAO Single section: Vertical: 36" ¥ 48" (914 ¥ 1219) Horizontal: 36" ¥ 18" (914 ¥ 457) Multiple section: Horizontal: 36" ¥ 36" (914 ¥ 914) 72" ¥ 18" (1829 ¥ 457) (optional) NOTE: Dimensions in parentheses ( ) are millimeters. www.pottorff.com Single Section C H H C Framed Unit — No Sleeve (Multiple section units supplied as individual dampers for field assembly) C C H H C Sleeve Style S — Common Sleeve (Multiple section units suppled as a single assembly) H (152) (178) (203) (229) (254) (279) (305) (330) (356) (381) (406) (432) (457) (483) (508) (533) (559) (584) (610) (635) (660) (686) (711) (737) (762) (787) (813) (838) (864) (889) (914) (940) (965) (991) (1016) (1041) (1067) (1092) (1118) (1143) (1168) (1194) (1219) 1-1/16" 1-3/16" 1-3/16" 1-3/16" 1-7/16" 1-7/16" 1-7/16" 1-9/16" 1-9/16" 1-13/16" 1-13/16" 1-13/16" 1-15/16" 1-15/16" 2-3/16" 2-3/16" 2-3/16" 2-5/16" 2-5/16" 2-9/16" 2-9/16" 2-9/16" 2-11/16" 2-11/16" 2-15/16" 2-15/16" 2-15/16" 3-1/16" 3-1/16" 3-5/16" 3-5/16" 3-5/16" 3-7/16" 3-7/16" 3-11/16" 3-11/16" 3-11/16" 3-13/16" 3-13/16" 4-1/16" 4-1/16" 4-1/16" 4-3/16" (27) (30) (30) (30) (37) (37) (37) (40) (40) (46) (46) (46) (49) (49) (56) (56) (56) (59) (59) (65) (65) (65) (68) (68) (75) (75) (75) (78) (78) (84) (84) (84) (87) (87) (94) (94) (94) (97) (97) (103) (103) (103) (106) 49" 50" 51" 52" 53" 54" 55" 56" 57" 58" 59" 60" 61" 62" 63" 64" 65" 66" 67" 68" 69" 70" 71" 72" 73" 74" 75" 76" 77" 78" 79" 80" 81" 82" 83" 84" 85" 86" 87" 88" 89" 90" 91" 92" 93" 94" 95" 96" (1245) (1270) (1295) (1321) (1346) (1372) (1397) (1422) (1448) (1473) (1499) (1524) (1549) (1575) (1600) (1626) (1651) (1676) (1702) (1727) (1753) (1778) (1803) (1829) (1854) (1880) (1905) (1930) (1956) (1981) (2007) (2032) (2057) (2083) (2108) (2134) (2159) (2184) (2210) (2235) (2261) (2286) (2311) (2337) (2362) (2388) (2413) (2438) 2-9/16" (65) 2-9/16" (64) 2-9/16" (63) 2-9/16" (62) 2-9/16" (61) 2-9/16" (60) 2-11/16" (68) 2-11/16" (67) 2-11/16" (66) 2-11/16" (65) 2-15/16" (75) 2-15/16" (74) 2-15/16" (73) 2-15/16" (72) 2-15/16" (71) 2-15/16" (70) 3-1/16" (78) 3-1/16" (77) 3-1/16" (76) 3-1/16" (75) 3-5/16" (84) 3-5/16" (83) 3-5/16" (82) 3-5/16" (81) 3-5/16" (80) 3-5/16" (79) 3-7/16" (87) 3-7/16" (86) 3-7/16" (85) 3-7/16" (84) 3-11/16" (94) 3-11/16" (94) 3-11/16" (94) 3-11/16" (94) 3-11/16" (94) 3-11/16" (94) 3-13/16" (97) 3-13/16" (97) 3-13/16" (97) 3-13/16" (97) 4-1/16" (103) 4-1/16" (103) 4-1/16" (103) 4-1/16" (103) 4-1/16" (103) 4-1/16" (103) 4-3/16" (106) 4-3/16" (106) Note: Dampers shown as vertical mount. Horizontal mount supplied in the same orientation. Multiple section dampers shown as one wide by two high two wide by one high similar. C C 6" 7" 8" 9" 10" 11" 12" 13" 14" 15" 16" 17" 18" 19" 20" 21" 22" 23" 24" 25" 26" 27" 28" 29" 30" 31" 32" 33" 34" 35" 36" 37" 38" 39" 40" 41" 42" 43" 44" 45" 46" 47" 48" H Sleeve Style IS — Integral Sleeve (Multiple section units supplied as individual dampers for field assembly) Information is subject to change without notice or obligation. POTTORFF ® 5101 Blue Mound Road, Fort Worth, Texas 76106 NOTE: Dimensions in parentheses ( ) are millimeters. www.pottorff.com Curtain Dampers VFD10DA (2/2) June 2014 C Multiple Section Nominal Blade Stack Duct Height 'H' Height 'C' Blade Stack Height 'C' Vertical Dampers Only Nominal Duct Height 'H' Vertical Dampers Only Blade Stack Dimensional Data
© Copyright 2024 ExpyDoc