VFE combi installation into natural slate VELUX Company Ltd

VELUX Products:
VELUX transverse drainage gutter
GGL
VELUX BFX underfelt collar
VELUX transverse drainage gutter
or
VELUX EFN top gutter
VELUX drainage gutter clip
A
m
m
Felt/breather membrane
m
Ventilation path
m
VELUX BFX underfelt collar
55
60
-1
00
A
B
B
B
B
B
GPL
Insulation
Double trimmers
VFE
Service area
B
Vapour barrier
A
Gutter Detail
1:2.5
Felt/breather membrane
A
EFN
Internal finish
EBY W10
top line of tiling batten
A
A
C
A
C
VELUX lining LS-
TYPICAL ELEVATION
BFX
10 to 18mm
Installation batten
B
BDX
VELUX EFN bottom gutter
min. 15 mm
Line of EBY trimmer
VELUX GGL (or GPL) roof window
Gasket in window frame
VELUX EFN bargeboard profile
BBX
SETTING OUT FOR GGL/GPL
ROOF WINDOW OVER VFE:
VELUX VFE vertical window
A
mm
B
mm
20
70
85
25
80
90
30
85
95
35
95
105
40
110
110
45
125
120
50
140
135
55
160
155
Insulation
min. 130 mm
Typical wall construction
Section C-C
1:5
VELUX lining LS-
Vapour barrier
Lining batten
VELUX Lining LV-
LS-
LV-
Roof covering:
SLATES
< 8 mm
VELUX VFE vertical window
VELUX EFN insulation profile
VELUX EFN L-shaped side soakers
18 mm
VELUX Underfelt collar BFX
VELUX GGL/GPL roof windows
Blue line level
VELUX lining LV-
Section A-A
1:5
min. 130 mm
Felt/breather
membrane
Gasket on BBX in window rebate
Ventilation path
min. 35 mm
VELUX Insulation frame BDX
25-30 mm
VELUX Vapour barrier BBX
VELUX Lining LSInsulation
Vapour barrier
Typical wall construction
VELUX Company Ltd
Woodside Way
Glenrothes, Fife KY7 4ND
tel: +44 (0) 1592 778 225
C VELUX GROUP
R VELUX & VELUX logo are registered trademarks
VELUX vertical window
VFE combi installation into natural slate
EFN flashing kit - recessed install - 18mm frame gap
All dimensions are in millimetres where shown
VELUX EBY Trimmer
Rafters
Section B-B
1:5
NOTE! When installing VELUX roof windows, flashings and accessories,
please ensure compliance with building regulations and British/European
standards where necessary.
This detail represents the principles of a typical installation only and the
design and specification of the final detail is the responsibility of others.
Latest revision:
Date:
June 2014
File name:
VFE-EFN-0114-1184
Rev no:
Rev date:
Drawn:
PJH
Scale:
1:5 approx. @ A3
This drawing is the property of the VELUX Group and is not to be copied, reproduced or published in whole or in part without written consent from VELUX A/S