Basler Electric’s Digital Genset Controller (DGC-2020) is a highly advanced integrated genset control system. The DGC-2020 is
perfectly focused, combining rugged construction and microprocessor technology to offer a product that will hold up to almost
DQ\HQYLURQPHQWDQGÁH[LEOHHQRXJKWRPHHW\RXUDSSOLFDWLRQ·VQHHGV7KLVGHYLFHSURYLGHVJHQVHWFRQWUROWUDQVIHUVZLWFK
control, metering, protection and programmable logic in a simple, easy to use, reliable, rugged, and cost effective package.
FEATURES
•
•
•
•
•
•
•
•
Generator Metering (includes three-phase Mains)
Engine Metering
Genset Control
Engine and Generator Protection 27(2), 32, 40Q, 51(2), 59(2), 81O, 81U
Enhanced Generator Protection 78, 81ROCOF, 51 and 47 available
Load Sharing and Generator Sequencing (via LSM-2020)
Var sharing over Ethernet
BESTCOMSPlus®
- Programming and setup software
- Intuitive and powerful
- Remote control and monitoring
- Programmable Logic
- USB communications
• Automatic Transfer Switch Control
‡ ([HUFLVH7LPHU
• Automatic Synchronizer (optional)
• Suitable for use on rental gensets with
- High/Low line sensing
- Single or three phase sensing override
- Wye/Delta/Ground Delta
• SAE J1939 Engine ECU communications
‡$XWRPDWLF*HQHUDWRU&RQÀJXUDWLRQ'HWHFWLRQ
• Selection of integrating reset or instantaneous reset characteristics
for overcurrent protection
• Multilingual capability
• Remote communications to our RDP-110
‡ ([WUHPHO\UXJJHGIXOO\SRWWHGGHVLJQ
• 16 programmable contact inputs
• 7 Contact outputs: (3) 30 Adc and (4) Programmable 2 Adc rated contacts
• Additional (8) Programmable 2 Adc contacts (optional)
• Wide Ambient Temperature range
‡ 5HPRWH'LDORXWDQG'LDOLQFDSDELOLW\ZLWK([WHUQDO0RGHPYLD
RS-232 (optional)
• Modbus™ Communications with RS-485 (optional)
• Ethernet communications (via LSM-2020 Load Sharing Module)
‡ 8/UHFRJQL]HG&6$FHUWLÀHG&(DSSURYHG*2675FHUWLÀHG
• HALT (Highly Accelerated Life Tests) tested
• IP 54 Front Panel rating with integrated gasket
• NFPA110 Compatible
• Expandable functionality via add-on modules
- LSM-2020 Load Sharing Module
&(0&RQWDFW([SDQVLRQ0RGXOH
$(0$QDORJ([SDQVLRQ0RGXOH
SPECIFICATIONS
Operating Power
Nominal:
12 or 24 Vdc
Range:
6 to 32 Vdc
Power Consumption:
Sleep Mode: 5W, all relays non-energized
Typical Operational Mode: 14.2W - Run
mode, LCD heater on, 6 relays energized
Battery Ride Through:
Withstands cranking ride-through down to
0 V for 50 ms (typical).
Current
Continuous
Rating:
1 Second Rating:
Burden:
5 Aac
1 Aac
0.1 to 5.0 Aac
10 Aac
1 VA
0.02 to 1.0 Aac
2 Aac
1 VA
Voltage
Range:
Frequency Range:
Burden:
1 Second Rating:
12 to 576 V rms, line-to-line
10 to 72 Hz for 50/60 style and
10 to 480 Hz for 400 Hz style
1 VA
720 V rms
Frequency
Metering Range:
0 to 576 Vac
Metering Accuracy:
±1.0% rated or ±2 Vac
(continued on page 2)
ADDITIONAL INFORMATION
INSTRUCTION MANUAL
SPECIFICATIONS
pages 1 and 2
ORDERING
INFORMATION
page 2
Request Publication 9400200990
12570 STATE ROUTE 143, HIGHLAND, ILLINOIS 62249 USA PHONE 618-654-2341 FAX 618-654-2351
SNJ-15
11-13
DGC-2020
SPECIFICATIONS
Contact Sensing
Contact Inputs (12):
Emergency Stop:
N.O., Dry Contacts
N.C., Dry Contacts
Engine System Inputs
Engine Speed Sensing:
Magnetic Pickup Voltage Range: 3 to 35 V peak (6 to 70 V peak-peak)
Frequency Range: 32 to 10,000 Hz
Generator Voltage Range: 12 to 576 V rms
Stated accuracies are subject to the accuracy of the senders used.
Resistive Senders
Fuel Level Sender:
33 to 240 : nominal
Coolant Temperature Sender: 62.6 to 637.5 : nominal
Oil Pressure Sender:
53 to 240 : nominal
Output Contacts
Fuel Solenoid, Engine Crank, Pre-Start Relays Rating:
30 Adc at 28 Vdc-make, break, and carry
Programmable Relays (up to 12) Rating:
2 Adc at 30 Vdc-make, break, and carry
Environmental
Temperature
Operating:
Storage:
Humidity:
Salt Fog:
Ingress Protection:
Shock:
5 to 29 to 5 Hz:
29 to 52 to 29 Hz:
52 to 500 to 52 Hz:
-40 to 70°C (-40 to 158°F)
-40 to 85°C (-40 to 185°F)
IEC 68-2-38
ASTM B 17-73, IEC 68-2-11
(tested while operational)
IEC IP54 for front panel
15 G in 3 perpendicular planes
1.5 G peak for 5 min.
0.036 in. double amplitude for 2.5 min.
5 G peak for 7.5 min.
Agency Approvals
CSA Approval, NFPA Compliance, CE Compliance,
8/5HFRJQL]HG*2675&HUWLÀHG
Physical
Weight: 2 kg (4.4 lb)
STYLE CHART
P.A.E. Les Pins, 67319 Wasselonne Cedex FRANCE
Tel +33 3.88.87.1010 Fax +33 3.88.87.0808
e-mail: [email protected]
12570 State Route 143, Highland, Illinois 62249-1074 USA
Tel +1 618.654.2341 Fax +1 618.654.2351
e-mail: [email protected]
www.basler.com
No. 59 Heshun Road Loufeng District (N),
Suzhou Industrial Park, 215122, Suzhou, P.R.China
Tel +86(0)512 8227 2888 Fax +86(0)512 8227 2887
e-mail: [email protected]
111 North Bridge Road #15-06 Peninsula Plaza
Singapore 179098
Tel +65 68.44.6445 Fax +65 65.68.44.8902
e-mail: [email protected]