825 kVA / 660 kW - ShresthaMachinery.com

825 kVA / 660 kW
POWERED by CUMMINS
AC825
DIESEL GENERATING SET
400/230 V - 50 Hz
MODEL
Power
Pf. 0.8
Standby
Prime
AC825
kVA
kW
kVA
kW
825
660
750
600
Standby : Continuous running at variable load for duration of an emergency. No overload is permitted on these ratings. In accordance with ISO 3046 .
Prime : Continuous running at variable load for unlimited periods with 10% overload available for 1 hour in any 12 hour period. In accordance with ISO 8528,ISO 3046.
9 High quality, reliable and complete power unit
9 Compact design
9 Easy start and maintenance possibility
9 Every generating set is subject to a comprehensive test program which includes full load testing, checking
and provision of all control and safety shut down functions testing
9 Fully engineered with a wide range of options and accessories: Canopy, sound proof canopy and on-road trailer
Manufacturer reserves the right to make changes in model, technical specifications, color, equipment and accessories without prior notice.
ENGINE
CUMMINS
Model
Engine Power Output
at rated rpm
Aspiration and Cooling
Total Displacement
No. of Cylinders and Build
Engine Speed
Bore and Stroke
Compression Ratio
Governor
Fuel Consumption at full load
Fuel Tank Capacity
Oil Capacity
Coolant Capacity
Radiator Cooling Air
Air Intake – Engine
Exhaust Gas Flow
9
9
9
9
9
9
kWm
HP
Litre
rpm
mmxmm
L/hr
Litre
Litre
Litre
m³/min
m³/min
m³/min
Heavy duty Cummins diesel engine
Four stroke, water cooled, turbocharged & aftercooled
Direct injection fuel system
Electronic Governor system
12/24 V D.C. starter and charge alternator
Replaceable fuel filter, oil filter and dry element air filter
VTA28G6
722
968
Turbocharged&Aftercooled
28
12 V
1500
140x152
13.1:1
Electronic
180
850
83
166
900
5
120
9 Cooling radiator and fan
9 Starter battery (with lead acid) including Rack and Cables
9 Flexible fuel connection hoses and manual oil sump
drain valve
9 Industrial capacity exhaust silencer and steel bellows
9 Jacket water heater(at automatic models)
9 Operation manuals and circuit diagram documents
ALTERNATOR
Design
Stator
Rotor
Insulation System
Standard Temperature Rise
Exciter Type
Phase Rotation
Alternator Cooling
AC Waveform Total Harmonic Distortion
Telephone Influence Factor (TIF)
Telephone Harmonic Factor (THF)
9
9
9
9
Brushless single bearing, revolving field
2/3 pitch
Single bearing, flexible disc
Class H
125 - 163°C Continuous
Self Excited
A (U), B (V), C (W)
Direct drive centrifugal blower fan
No load < 1.5%. Non distorting balanced
linear load < 5%
<50 per NEMA MG1-22.43
<2%
Brushless, single bearing system, flexible disc, 4 poles
9 Impregnation with tropicalised epoxy varnish
Insulation class H
9 Solid state Automatic Voltage Regulator
Standard degree of protection IP21 (*IP22/IP23 is availab.) 9 Stator winding with 2/3 pitch for improved harmonics
Self-exciting and self-regulating
CONTROL SYSTEM
Control supervision and protection panel is mounted on the genset base frame.
The control panel is equipped as follows:
1. Auto Mains Failure Control Panel
Panel equipments:
9 Control with AMF module
9 Static battery charger
9 Emergency stop push button
DSE 7320
a) Generating set control module DSE 7320 features:
9 The module is used to monitor a mains supply and
starts and stops a standby generating set
9 Micro-processor based design
9 Automatic control of mains and generator contactors
9 Monitors engine performance and AC power output
9 LED alarm indication
9 Front panel conguration of timers and alarm trip points
9 Easy push button control
STOP/RESET - MANUAL –TEST- AUTO – MUTE ALARM – START
b) Metering via LED display:
9 Generator Volts (L-L / L-N)
9 Engine oil pressure (PSI-Bar)
9 Generator Ampere (L1,L2,L3)
9 Engine temperature (°C&°F)
9 Generator Frequency (Hz)
9 Plant battery volts
9 Engine hours run
9 Mains Volts (Ph-Ph/Ph-N)
9 Generator kVA, kWh
9 Generator kW as % of rated kW setting
9 Generator Cos (σ)
c) Alarms:
9 Over and Under Speed
9 Low and High Battery Volt.
9 Start and Stop Failure
9 Charge fail
9 Over Current
9 Under / Over Generator Voltage
9 Low Oil Pressure
9 Emergency stop
9 High engine temperature
9 kW overload
9 Unbalanced load
9 Independent earth fault trip
d) LED Indications
Four configurable LED’s like:
9 Mains available
9 Generator available
9 Mains on load
9 Generator on load
2. Power Outlet Terminal Board Mounted
on the Genset Base frame
OPTIONAL EQUIPMENTS
Dlesel Englne
9 Oil heater
Altemator
9 3/4 Pole Output Circuit Breaker
9 Anti-condensation Heater
Panel
9 Charge ammeter
9 Transfer Switch 3 Pole
9 Transfer Switch 4 Pole
9 Earth Fault ,single set
Accessories
9 Bulk fuel tank
9 Automatic filling system
9 Fuel-water separator filter
9 Low fuel level alarm
9 Residential silencer
9 Enclosure or sound proof canopy
9 Trailer
9 Manual oil drain pump
9 Tool kit for maintenance
CHASSIS
9
9
9
9
9
9
The complete gen-set is mounted as whole on a heavy-duty fabricated, steel base frame
Anti-vibration pads are fixed between the engine/ alternator feet and the base frame
Base frame design incorporates an integral fuel tank (Up to 750 kVA)
The generating set can be lifted or carefully pushed / pulled by the base frame
Dial type fuel gauge and drain plug on the fuel tank
Forklift pockets within base frame (up to 500kVA)
DIMENSIONS
OPEN TYPE
DIMENSIONS (LxWxH)
DRY WEIGHT
mm
kg
4100x1450x1998
4800
SOUND ATTENUATED TYPE
DIMENSIONS (LxWxH)
DRY WEIGHT
mm
kg
5800x2260x2550
11250
CANOPY
H
L
9
9
9
9
All canopy parts are designed with modular principles
Without welding assembly
Doors on each side
All metal canopy parts are painted by electrostatic
polyester powder paint
9
9
9
9
9
Exhaust silencer is protected against environment influences
Thermally insulated engine exhaust system
Emergency stop push button is installed outside of the canopy
Easy lifting and moving
Easy maintenance and operation