K14517 6/07 Rev. A DCID-EXT Dialer Capture Intelligence Device INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The Honeywell DCID-EXT Dialer Capture Intelligence Device (referred to as the DCID-EXT) is intended for control panels that DO NOT support the Honeywell ECP bus and therefore are not capable of communicating with Honeywell AlarmNet communication devices over an ECP bus. Additionally it is for instances where NO PHONE LINE SERVICE is used for reporting. INSTALLATION Notes: • Ensure the power source complies with the specified input voltage for this device. The power source must utilize a battery backup. • When used with control panels where no wired zones are available (for wiring the output TRIGGER signal to), mount the DCID-EXT inside the control panel. This DCID-EXT can be mounted external to, or inside the control panel’s cabinet. • When used with control panels that have an available wired zone (for wiring the output TRIGGER signal to), the DCID-EXT may be mounted inside the control panel or mounted externally. • The DCID-EXT will report certain trouble conditions by activating the Trigger signal sent to the control panel. An active Trigger signal will be set when any of the following conditions occur: The DCID-EXT Dialer Capture Intelligence Device captures Contact ID messages from a control panel’s phone line and sends them to a Honeywell ECP bus AlarmNet communications device (e.g., 7845GSM), which then communicates those messages to the central station over the GSM network or internet. OPERATION When an event occurs, the control panel goes off hook to dial the central station. The DCID-EXT detects the offhook condition and provides the control panel with a dial tone. When the control panel detects the dial tone, it begins dialing the central station. After the phone number is completed, the DCID-EXT returns a handshake to the control panel. The control panel then sends the reports to the DCIDEXT, which in turn sends them over the ECP bus to the AlarmNet communications device. The DCID-EXT kisses off each report received successfully from the control panel. The communications device then transmits the messages to the central station (either over the GSM network, or the internet, as applicable). When all the reports are sent, the DCID-EXT goes off hook. DCID-EXT Summary of Connections label SPECIFICATIONS Physical: 6-1/2” H x 4-1/4” W x 1-1/4” D (165mm x 110mm x 32mm) Electrical: Input Voltage: 12VDC nominal (9-14VDC, from control panel) Input Current: 40mA standby / 80mA active The built-in tamper switch detects the cover being removed. ♦ An AlarmNet communications device fault occurs. The above condition will be reported if the output trigger is wired to an available zone and the red power wire to the DCID-EXT is intact. To ensure the security of the red power wire, mount the DCID-EXT in the control panel. External Horizontal Wall Mounting: For horizontal mounting, two slotted holes are used. 1. 2. 3. PACKAGE CONTENTS The following items are included: • • ♦ Measure and transfer the position of the two horizontal mounting holes to the desired mounting area. Drill 3/16 inch holes for drywall, or 7/32 inch holes for plaster. Tap in plastic wall anchors. Insert self-tapping screws into the wall anchors leaving the heads projecting 1/8”. Hang the DCIDEXT on the screw heads via two of the slotted holes on the module back. External Vertical Wall Mounting: For vertical mounting, one slotted hole and one open hole are used. The circuit card must be removed for access to the open hole. 1. 2. 3. 4. Measure and transfer the position of the two vertical mounting holes to the desired mounting area. Drill 3/16 inch holes for drywall, or 7/32 inch holes for plaster. Tap in plastic wall anchors. Insert a self-tapping screw into the wall anchor for the slotted hole leaving the head projecting 1/8”. Remove the enclosure cover by gently prying the cover off. 5. 6. 7. phone line voltage. When the radio becomes initialized, normal operation will resume. Remove the circuit board by squeezing the two internal plastic retention tabs, while gently pulling the circuit card. Hang the DCID-EXT enclosure on the screw, then insert the second screw through the enclosure back into the open hole. Orient the circuit board edge in the enclosure starting with the side opposite the two plastic retention tabs. When the circuit board edge is properly seated, push to snap the opposite end of the board into place. Internal Control Panel Mounting: When mounting inside of control panels, the mounting method must be determined by the installer depending on the particular control panel. If raised tabbed holes are available, please use them. For those panels where raised tab holes are not available, then a sufficient amount of double stick foam tape (installer supplied) or other suitable method should be used. It is important to locate the DCID-EXT within the control panel so that its cover can easily be removed for testing and service. CONNECTIONS 1. If the enclosure cover is on, remove by gently prying the cover off. 2. Connect the wires as shown in the DCID-EXT Dialer Capture Intelligence Device Connections diagram. 3. Affix the supplied Summary of Connections label to the inside of the enclosure cover. 4. Replace the enclosure cover by snapping back in place. Pulse dialing is not supported and must be disabled in the control panel. Since this product does not communicate through a PABX, do not program the PABX fields. To ensure the maximum amount of messages can be transmitted to the central station before a com failure occurs, ensure the control panel is programmed with a primary and secondary central station number. Ensure the control panel is programmed for the maximum number of retry attempts. This product only supports one-way communications (from the control panel to the central station). For those control panels that support two-way voice communications, speakerphone, paging, follow-me, etc., these features will no longer be available. The control panel must be programmed for one-way communications only. Since this product only supports one-way communications (from the control panel to the central station), the Honeywell Compass Downloader cannot be used. In the event this product loses power (such as from a cut wire) it would not be able to generate a fault trigger to the control panel and set an alarm. In this case, after the panel has exhausted its redial attempts, a com failure will be displayed by the panel (you may have to scroll through the messages). If the DCID-EXT senses a fault, it will send a Trigger signal to the control panel zone (if wired to a zone). At this point the DCID-EXT will also drop the phone line voltage and will not provide a dial tone to the control panel. During this time, the control panel will make retry attempts (8 for residential, and more for commercial) to dial out and send a report. Until the control panel has completed the series of retry attempts it will not be able to detect a Telco fault. INSTALLATION AND CONFIGURATION NOTES Please read each configuration note and implement the appropriate ones for the installation. Mark each “Check Box” to ensure the notes are understood and implemented as necessary. The AlarmNet communications device must be configured as device 3 on the ECP bus. Ensure other devices do not conflict with this address. The subscriber ID sent to the central station will be the one programmed into the AlarmNet communications device, not the one in the control panel. This product supports 4-digit account code Contact IDs. Since control panel messages are now routed through the DCID-EXT to the central station, the message confirmation kissoff signal sent back to the control panel ONLY confirms the DCID-EXT received the message. Under certain communication conditions it is possible that the control panel message was not received by the central station. When the DCID-EXT is first powered up and does not detect an initialized radio within 5 minutes, it will generate a fault to the control panel. Additionally the control panel will not receive To minimize the wait time, for control panels that allow setting the Telco Fault detection time, please set it to the minimum detection time. 2 For control panels that may generate erroneous Telco fault conditions based on grounding (such as the VISTA-15), at the control panel turn off "Telco Fault" monitoring. If an AlarmNet communications device fault is detected, this will be reported to the control panel as a com failure. If Telco fault is turned on, an AlarmNet failure will be displayed as a Telco Fault. If the DCID-EXT trigger is wired to a zone, the DCID-EXT will trigger the control panel to alarm this zone and display a message. With some control panels, displayed alarm messages for triggered zones may hide a "com failure" message. The com failure message can be displayed by first clearing the zone alarm message(s). DCID-EXT, keypads and AlarmNet communications device will be reset. If the DCID-EXT, keypads, and the AlarmNet communications device are powered from the control panel’s aux power (that is reset for a fire alarm reset), and a fire alarm reset occurs, the This device is not compatible with the Apex Destiny 6100 control panel. DCID-EXT DIALER CAPTURE INTELLIGENCE DEVICE CONNECTIONS NOTES: 1.THE TRIGGER SIGNAL MUST BE WIRED TO A CONTROL PANEL 24 HOUR ZONE. DO NOT WIRE TRIGGER TO A 2-WIRE SMOKE DETECTOR ZONE. DCID-EXT STATUS LEDs INDICATION STATUS GREEN - STEADY ON POWER ON GREEN - FLASHING RED - STEADY ON POWER ON, AND ECP ACTIVITY OFF HOOK, AND BUFFER FULL RED - FLASHING TELCO ACTIVITY 2. WIRE THE EOLR ACROSS THE DCID-EXT TRIGGER AND GND TERMINALS TO ENSURE CABLE SUPERVISION. 3. LENGTH OF CABLE TO ALARMNET COMMUNICATIONS DEVICE SHALL NOT EXCEED 50 FEET. TB RING ELECTRICAL SPECIFICATIONS: TIP EOLR VOLTAGE: 12VDC NOMINAL (9-15VDC, FROM CONTROL PANEL) CURRENT: 40MA STANDBY / 80MA ACTIVE CONTROL PANEL RING (RED) INCOMING PHONE LINE TIP (GRN) BLK GND AUX PWR GROUND RED +12 VDC AUX PWR TRIGGER (HIGH SIDE OF ZONE) AUX PWR TRIG ZONE TB (ECP BUS) YEL STATUS LEDs NOT USED DATA OUT DATA IN GRN DATA IN DATA OUT RED V+ V+ BLK GND GND RJ-45 JACK USE RJ-45 CABLE ONLY COVER TAMPER SWITCH (REED) NOTE: IF A SEPARATE AUX POWER SUPPLY IS USED, ENSURE IT UTILIZES A BATTERY BACKUP, AND ITS GROUND IS CONNECTED TO THE CONTROL PANEL AUX POWER SUPPLY GROUND. ALARMNET COMMUNICATIONS DEVICE ALTERNATE CONNECTION TO CONTROL PANEL INCOMING PHONE LINE (TIP-GRN, RING-RED) DCID-EXT-SOC-V0 DCID-EXT Interface Terminal Function Destination Ring (Typically Red or Yellow) Telco Ring signal. Control Panel incoming phone line Ring terminal. Tip (Typically Green or Black) Telco Tip signal. Control Panel incoming phone line Tip terminal. Black Circuit ground. Control Panel Aux Pwr Out – (GND) Red Circuit power. 12VDC nominal (9-15VDC) with battery backup. Control Panel Aux Pwr Out + (12VDC) Trig (Orange) Fault output. The Trigger signal is an open collector signal that is active closed. This signal must be wired to a control panel 24 hour zone. Control Panel zone terminal. Yellow ECP bus Data Out. AlarmNet communication device ECP data in. Green ECP bus Data In. AlarmNet communication device ECP data out. Red ECP bus V + In. AlarmNet communication device +12VDC in. Black Circuit ground. AlarmNet communication device GND. RJ-45 Jack This is used as an alternate connection for those installations where a RJ-45 cable is a more convenient interface to the control panel. Control Panel RJ-45 jack, or incoming phone line terminals. 3 REFER TO THE CONTROL PANEL INSTALLATION INSTRUCTIONS FOR DETAILS REGARDING THE ENTIRE ALARM SYSTEM. LIMITED WARRANTY Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller") 2 Corporate Center Drive, Melville, New York 11747, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s) not having a manufacturer’s date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid, to Honeywell Factory Service, 2 Corporate Center Drive, Melville, New York 11747. THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. 2 Corporate Center Drive, Melville, NY 11747 Copyright 2007 Honeywell International Inc. www.honeywell.com/security ÊK14517AŠ K14517 6/07 Rev. A
© Copyright 2024 ExpyDoc