Circular electric duct heaters EKA EKA (-NV,-NI,-NIS,-PTC) 100-0.3-1f EKA Circular electric duct heater NV With integrated temperature control, internal setpoint With integrated temperature control, external remote setpoint must be connected NIS With integrated temperature control The external control signal (0-10V) is needed. NI PTC With air flow sensor 100 Heater diameter [mm] 0.3 Heating power [kW] 1f Number of phases Type IP class Heating power [kW] Voltage V/50Hz Suitable controller EKR Accessories EKR EKR EKR EKR EKR EKR EKR EKR Duct temperature sensor TJK 10K Controller for electric heaters EKR: EKR EKR EKR EKR EKR EKR EKR30, EKR30P EKR EKR ELECTRIC DUCT HEATERS EKR EKR EKR EKR EKR EKR EKR15.1, EKR15.1P EKR EKR EKR EKR Heaters conform with IEC 60335-2-30 : 1996, EN 600335-2-30 : 1999, EN 61010-1+ A2 : 2000, EN 50081-2 : 1995, EN 55011 : 1999+ A1 : 2001 standards and are CE marked. EKR 6.1 Circular electric duct heaters EKA All EKA duct heaters has two-stage overheat protection: 1)the first stage switches on when the temperature reaches 50°C (Resets automatically). 2)the second stage switches on when the temperature reaches 100°C Heating power [kW] Voltage V/50Hz Suitable controller EKR EKA 250-1,5-1f 1,5 1 ~ 230 EKR EKA 250-2,0-1f 2 1 ~ 230 EKR EKA 250-3,0-1f 3 1 ~ 230 EKR EKA 250-3,0-2f 3 2 ~ 400 EKR EKA 250-5,0-2f 5 2 ~ 400 EKR EKA 250-6,0-2f 6 2 ~ 400 EKR EKA 250-3,0-3f 3 3 ~ 400 EKR EKA 250-6,0-3f 6 3 ~ 400 EKA 250-9,0-3f 9 3 ~ 400 EKA 315-1,2-1f 1,2 1 ~ 230 EKA 315-1,5-1f 1,5 1 ~ 230 EKA 315-2,0-1f 2 1 ~ 230 EKA 315-3,0-2f 3 2 ~ 400 EKA 315-5,0-2f 5 2 ~ 400 EKA 315-6,0-2f 6 2 ~ 400 EKA 315-6,0-3f 6 3 ~ 400 EKR EKA 315-9,0-3f 9 3 ~ 400 EKR EKA 315-12-3f 12 3 ~ 400 EKR EKA 400-3,0-2f 3 2 ~ 400 EKR EKA 400-5,0-2f 5 2 ~ 400 EKR EKA 400-6,0-2f 6 2 ~ 400 EKR EKA 400-6,0-3f 6 3 ~ 400 EKR EKA 400-9,0-3f 9 3 ~ 400 EKR EKA 400-12-3f 12 3 ~ 400 EKR EKA 400-15-3f 15 3 ~ 400 EKR Type IP class Accessories EKR EKR EKR EKR EKR EKR EKR Duct temperature sensor TJK 10K Controller for electric heaters EKR: EKR EKR EKR30, EKR30P EKR15.1, EKR15.1P EKR 6.1 ELECTRIC DUCT HEATERS Heaters conform with IEC 60335-2-30 : 1996, EN 600335-2-30 : 1999, EN 61010-1+ A2 : 2000, EN 50081-2 : 1995, EN 55011 : 1999+ A1 : 2001 standards and are CE marked. Temperature sensors Temperature sensors TJ TJK10K Duct temperature sensors TJK10K, TJK PT1000 are used for measuring air temperature in ventilation system ducts. Duct temperature sensors are delivered with installation flange. Insertion length can be adjusted with flange. Type IP class Thermistor (10KΩ @ 25°C), range -30..105°C Measurement accuracy Sensor tube Length Diameter Cable length Plastic TEMPERATURE SENSORS Controllers for electric heating EKR PRODUCT HIGHLIGHTS FOR THREE PHASE DUCT HEATERS CONTROLLED POWER TILL 255 kW MODERN CASING DESIGN Type Controlled load [kW] Relay output Voltage [V] 15 1x5A/230V 3x230/3x400 15 4x5A/230V 3x230/3x400 30 1x5A/230V 3x230/3x400 30 4x5A/230V 3x230/3x400 Controllers conforms to requirements of standards EN 61010-1+A2:2000, EN 50081-1:1995, EN 55022:2000 and carries CE mark. CONTROLLERS FOR ELECTRIC HEATING EKR15.1, EKR30 is a proportional controllers for electric heaters with automatic voltage adaptation. EKR15.1P, EKR30P is a proportional controllers for multistep (up to 5 steps) electric heaters with automatic voltage adaptation. Controllers EKR are designed only for electric heating control. The control principle makes it unsuitable for motor or lighting control. EKR controls the whole load On-Off. The ratio between On-time and Off-time is varied 0-100% to suit the prevailing heat demand. EKR15.1 can control 15kW heater and has relay output for extra load control with contactor, on which can be connected load up to 12kW. Full load can be 27kW. EKR15.1P can control with triac output 15kW heater and has four relay outputs for 4 extra load steps control with contactors, on which can be connected load up to 450kW. EKR30 can control 30kW heater and has relay output for extra load control with contactor, on which can be connected load up to 12kW. Full load can be 42kW. EKR30P can control with triac output 30kW heater and has four relay outputs for 4 extra load steps control with contactors, on which can be connected load up to 450kW. Full load can be 470kW. Controllers for electric heating EKR PRODUCT HIGHLIGHTS FOR ONE AND TWO PHASE DUCT HEATERS EKR 6.1 is a proportional controller for electric heating, with automatic adaptation of voltage. An internal or an external sensor is used with the device. EKR 6.1 controls the heating intensity by switching electrical power on or off. The ratio between the on-time and off-time depends on the need for heating and can vary in the range between 0% and 100%. EKR6.1 is suitable for the control of electrical heating only. EKR6.1 is not suitable for the control of three-phase electrical current, it is used to control monophasic and diphase heaters only. Night function (NIGHT) setpoint reducing 0..10°C, then timer is connected and its contacts close. Supply air temperatures can be limited (MIN, MAX), then 2 sensors wiring diagram is used. CONTROLLERS FOR ELECTRIC HEATING Type Controlled load [kW] Max. controlled current [A] Voltage [V] 1x230/2x400 Controllers conforms to requirements of standards: LST EN 61010-1:2002, LST EN55022:2000, LST EN 60730-1+A11: 2002/A16 2007, marked with conventional sign CE.
© Copyright 2024 ExpyDoc