Technical Data Physical Data Performance Data Acoustic Performance Data Construction Code Description Cheetah Fan Coil Unit Technical Data Plan View 365mm 55mm A B Width A 55mm 235mm Side View 121mm 35mm 49mm 270mm 475mm 270mm 10mm Fan Coil Physical Data 200 & 250 Spigot Centres 315 Spigot Centres Number of Spigots Width (mm) A (mm) B (mm) A (mm) B (mm) 1 3 602 301 - 301 - 2 4 952 276 400 276 400 3 5 1252 276 350 276 350 4 6 1552 176 400 251 350 5 6 1902 201 500 276 450 Size Pipe connections 15mm for both heating & cooling Left hand coil connection is shown being viewed from below. Right hand coil connections are also available. 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 1 Cheetah Fan Coil Unit Technical Data Plan View 55mm A B Width A 55mm 285mm 235mm Side View 146mm 49mm 35mm 320mm 300mm 247mm 475mm 10mm 300mm Module Physical Data Module Length (mm) Module Length (mm) Fresh air plenum 250 Discharge attenuator 300 Fresh air plenum with filter 260 Discharge standard (200mm) plenum 270 Return air plenum 270 320 385 Discharge drop (250mm) plenum 320 Return air plenum with filter 280 330 395 Discharge drop (315mm) plenum 385 Inlet attenuator 300 600 900 Prestige rectangular discharge attenuated plenum 270 Inlet attenuator with filter 310 610 910 Inboard filter with underside access for fully ducted systems 65 Core fan coil unit 475 Electric heater 300 Core fan coil unit with filter 485 Electric heater with filter 310 600 900 570 870 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 2 Prestige Cheetah Fan Coil Unit Technical Data With Rectangular Discharge Plenum Plan View Fan Coil Physical Data 55mm Width 55mm Size Width (mm) Width 1 (mm) 1 602 542 2 952 892 3 1252 1192 4 1552 1492 5 1902 1842 Left hand coil connection is shown being viewed from below in the direction of airflow. Right hand coil connections are also available. Module Corner Unit Support Side View 12mm 235mm 55mm 35mm 270mm 247mm 475mm 10mm Each module has common drop rod placement holes predrilled as shown for easy on-site installation. End Elevation Showing Fan Coil Unit Discharge Width 1 30mm 175mm 235mm 30mm M8 nutserts to suit 30mm Doby/Mez flange Additional central nutsert on 233/333 units and above Internal acoustic lining 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 3 Cheetah Fan Coil Unit Technical Data Performance Data Guide Testing Procedure The data on the following pages has been derived from tests undertaken at a third party acoustic test facility in accordance with BS 4856: Part 4: 1997 “Determination of sound power levels of fan coil units, unit heaters and unit coolers using reverberation rooms”. A standard 200Ø spigotted fan coil unit was mounted in Reverberation Room 1 then ducted with 1000mm long solid circular galvanised sheet steel ducts to a dividing wall / plate and into Reverberation Room 2. If solid ducts are replaced by flexible ducts the discharge sound power levels (Lw) will reduce by: Acoustic Reduction to Lw 1000mm flexible duct 125 250 500 1k 2k 4k 8k Hz 4 5 9 11 10 8 8 dB Guide NR Levels Guide NR levels are based on a number of assumed parameters and a typical office installation. We have listed these parameters below, should these parameters not be applicable for a particular application, then a detailed acoustic assessment will be required. Acoustic Loss Allowed 125 250 500 1k 2k 4k 8k Hz Discharge ducts & 90° lined diffuser plenums(1) 9 13 17 20 20 20 14 dB False Ceiling SRI(2) 9 8 12 18 22 23 22 dB Room Size Ceiling Height Reverberation Time (mid frequency) Sizes 1 & 2 20m² 2.7m 0.35 s Sizes 3 & 4 30m² 2.7m 0.45 s Size 5 56m² 2.7m 0.60 s Fan Coil Unit Size The Guide NR level assumes that a single fan coil unit will be installed within a 600mm deep ceiling void above a room with the aforementioned characteristics, and serving 1000 x 100mm slot diffusers with 50% free area. A correction to the Guide NR level should be made where more than one unit is present in a room space. Return air grilles should be located at least 1.5m from the fan coil inlet. Guide NR levels are not applicable for Prestige units, If these are required then an acoustic assessment must be undertaken. Notes 1 includes 1000mm long, 200mm diameter flexible duct. 2 ceiling performance based on “Armstrong Supreme” ceiling tiles. 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 4 Cheetah Fan Coil Unit Technical Data Typical Performance Data Performance Criteria Electrical supply 230V, 1ph, 50Hz Heating air on temperature 20°C 82°C Cooling air on temperature db 23°C LPHW flow temperature Cooling air on % RH 50% LPHW return temperature Chilled water flow temperature 6°C Chilled water return temperature 12°C Specific Fan Power Size 71°C External static pressure 30 Pa All data is based on a 4-row coil option Air Off 11°C Air Off 12°C EC Version (W/l/s) Total Cooling Duty (kW) Sensible Cooling Duty (kW) Total Cooling Duty (kW) Sensible Cooling Duty (kW) Air Off 35°C Heating Duty (kW) Guide NR Level Air Flow (l/s) AC Version (W/l/s) 33 107 0.77 0.31 1.84 1.53 1.69 1.40 1.94 34 114 0.82 0.32 1.96 1.63 1.80 1.50 2.06 35 130 0.81 0.35 2.22 1.86 2.04 1.71 2.35 35 140 0.84 0.37 2.40 2.01 2.19 1.84 2.53 30 155 0.79 0.25 2.69 2.22 2.47 2.04 2.81 32 185 0.79 0.26 3.19 2.65 2.93 2.43 3.35 35 235 0.80 0.30 4.03 3.37 3.70 3.09 4.26 39 280 0.85 0.35 4.78 4.02 4.38 3.68 5.07 30 202 0.77 0.25 3.52 2.90 3.22 2.65 3.66 32 235 0.77 0.26 4.07 3.37 3.73 3.09 4.26 35 297 0.82 0.28 5.10 4.26 4.69 3.91 5.38 37 330 0.83 0.30 5.65 4.73 5.18 4.34 5.98 41 402 0.85 0.36 6.85 5.77 6.28 5.29 7.28 29 227 0.77 0.25 3.96 3.25 3.63 2.98 4.11 31 277 0.74 0.23 4.80 3.97 4.41 3.64 5.02 34 369 0.76 0.24 6.34 5.29 5.81 4.85 6.69 35 398 0.79 0.26 6.83 5.71 6.27 5.24 7.21 39 477 0.86 0.32 8.13 6.84 7.47 6.28 8.64 32 384 0.77 0.26 6.65 5.51 6.09 5.05 6.96 33 430 0.79 0.28 7.42 6.17 6.80 5.66 7.79 34 483 0.81 0.30 8.30 6.93 7.61 6.35 8.75 1 2 3 4 5 Please see page 4 for an explanation of how Guide NR values have been derived. Guide NR levels are not applicable for Prestige units. 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 5 Cheetah Fan Coil Unit Technical Data Typical Performance Data Performance Criteria Electrical supply 230V, 1ph, 50Hz Heating air on temperature 20°C 82°C Cooling air on temperature db 23°C LPHW flow temperature Cooling air on % RH 50% LPHW return temperature Chilled water flow temperature 5°C Chilled water return temperature 11°C Specific Fan Power Size 71°C External static pressure 30 Pa All data is based on a 4-row coil option Air Off 11°C Air Off 12°C EC Version (W/l/s) Total Cooling Duty (kW) Sensible Cooling Duty (kW) Total Cooling Duty (kW) Sensible Cooling Duty (kW) Air Off 35°C Heating Duty (kW) Guide NR Level Air Flow (l/s) AC Version (W/l/s) 33 107 0.77 0.31 1.91 1.53 1.75 1.40 1.94 34 114 0.82 0.32 2.03 1.63 1.87 1.50 2.06 35 130 0.81 0.35 2.31 1.86 2.12 1.71 2.35 35 140 0.84 0.37 2.49 2.01 2.28 1.84 2.53 30 155 0.79 0.25 2.79 2.22 2.57 2.04 2.81 32 185 0.79 0.26 3.32 2.65 3.04 2.43 3.35 35 235 0.80 0.30 4.19 3.37 3.84 3.09 4.26 39 280 0.85 0.35 4.97 4.02 4.55 3.68 5.07 30 202 0.77 0.25 3.65 2.90 3.34 2.65 3.66 32 235 0.77 0.26 4.22 3.37 3.87 3.09 4.26 35 297 0.82 0.28 5.30 4.26 4.87 3.91 5.38 37 330 0.83 0.30 5.87 4.73 5.39 4.34 5.98 41 402 0.85 0.36 7.00 5.67 6.53 5.29 7.28 29 227 0.77 0.25 4.11 3.25 3.76 2.98 4.11 31 277 0.74 0.23 4.99 3.97 4.57 3.64 5.02 34 369 0.76 0.24 6.59 5.29 6.04 4.85 6.69 35 398 0.79 0.26 7.09 5.71 6.51 5.24 7.21 39 477 0.86 0.32 8.46 6.84 7.76 6.28 8.64 32 384 0.77 0.26 6.90 5.51 6.32 5.05 6.96 33 430 0.79 0.28 7.70 6.17 7.07 5.66 7.79 34 483 0.81 0.30 8.62 6.93 7.90 6.35 8.75 1 2 3 4 5 Please see page 4 for an explanation of how Guide NR values have been derived. Guide NR levels are not applicable for Prestige units. 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 6 Cheetah Fan Coil Unit Technical Data Acoustic Data for Fan Coil Unit with Circular Discharge All the following data is based on the standard fan coil unit core module with inlet filter fitted and a 200Ø discharge plenum. AC / EC Model Air Flow (l/s) 107 201 or 301 114 130 140 155 202 or 302 185 235 280 202 235 203 or 303 297 330 402 227 277 204 or 304 369 398 477 384 205 or 305 430 483 Ext Pressure (pa) Sound Power Levels (dB) at Mid Octave Band Frequencies (Hz) 125 250 500 1k 2k 4k 8k Discharge 55 56 52 51 47 42 38 Inlet/Radiated 54 55 54 48 43 38 29 Discharge 55 57 53 51 48 43 40 Inlet/Radiated 55 56 55 49 44 39 31 Discharge 56 57 54 53 49 44 42 Inlet/Radiated 56 57 56 50 46 40 34 30 30 30 Discharge 58 57 55 54 51 46 45 Inlet/Radiated 57 56 57 51 47 42 36 Discharge 52 52 49 45 42 35 30 Inlet/Radiated 51 52 50 43 38 31 23 Discharge 54 54 51 49 46 40 34 Inlet/Radiated 53 54 53 46 41 35 26 30 30 30 Discharge 57 58 54 52 49 44 41 Inlet/Radiated 57 57 56 50 45 40 32 Discharge 59 60 56 55 52 48 46 Inlet/Radiated 59 60 58 52 48 43 37 Discharge 53 52 50 45 43 36 30 Inlet/Radiated 54 53 52 44 39 32 23 30 30 30 Discharge 55 54 52 47 45 38 33 Inlet/Radiated 56 55 53 45 41 35 25 Discharge 58 57 54 51 48 43 39 Inlet/Radiated 59 58 56 49 45 39 30 Discharge 59 59 55 53 50 45 42 Inlet/Radiated 60 59 57 50 47 42 33 30 30 30 Discharge 61 63 59 56 54 50 47 Inlet/Radiated 63 63 61 54 51 46 39 Discharge 50 51 48 43 40 32 27 Inlet/Radiated 52 52 50 42 36 28 22 Discharge 52 53 50 46 43 36 29 Inlet/Radiated 54 54 52 44 38 31 23 30 30 30 Discharge 55 56 53 49 47 41 35 Inlet/Radiated 57 57 55 48 43 37 27 Discharge 57 57 54 51 48 43 38 Inlet/Radiated 58 58 56 49 44 38 29 Discharge 60 60 57 55 53 48 44 Inlet/Radiated 62 61 58 52 48 43 35 30 30 30 Discharge 54 55 53 48 46 39 32 Inlet/Radiated 58 57 54 47 42 35 24 Discharge 56 56 54 49 47 41 35 Inlet/Radiated 59 58 55 48 43 37 26 Discharge 58 58 55 51 49 43 38 Inlet/Radiated 61 59 56 49 45 39 29 30 30 30 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 7 Cheetah Fan Coil Unit Technical Data Acoustic Data for Prestige Fan Coil Unit with Rectangular Discharge All the following data is based on the standard fan coil unit core module with inlet filter fitted and a rectangular discharge plenum. AC / EC Model Air Flow (l/s) 107 201 or 301 114 130 140 155 202 or 302 185 235 280 202 235 203 or 303 297 330 402 227 277 204 or 304 369 398 477 384 205 or 305 430 483 Ext Pressure (pa) Sound Power Levels (dB) at Mid Octave Band Frequencies (Hz) 125 250 500 1k 2k 4k 8k Discharge 54 54 50 47 39 36 34 Inlet/Radiated 53 53 52 44 35 32 25 Discharge 54 55 51 47 40 37 36 Inlet/Radiated 54 54 53 45 36 33 27 Discharge 55 55 52 49 41 38 38 Inlet/Radiated 55 55 54 46 38 34 30 20 20 20 Discharge 57 55 53 50 43 40 41 Inlet/Radiated 56 54 55 47 39 36 32 Discharge 51 50 47 41 34 29 26 Inlet/Radiated 50 50 48 39 30 25 19 Discharge 53 52 49 45 38 34 30 Inlet/Radiated 52 52 51 42 33 29 22 20 20 20 Discharge 56 56 52 48 41 38 37 Inlet/Radiated 56 55 54 46 37 34 28 Discharge 58 58 54 51 44 42 42 Inlet/Radiated 58 58 56 48 40 37 33 Discharge 52 50 48 41 35 30 26 Inlet/Radiated 53 51 50 40 31 26 19 20 20 20 Discharge 54 52 50 43 37 32 29 Inlet/Radiated 55 53 51 41 33 29 21 Discharge 57 55 52 47 40 37 35 Inlet/Radiated 58 56 54 45 37 33 26 Discharge 58 57 53 49 42 39 38 Inlet/Radiated 59 57 55 46 39 36 29 20 20 20 Discharge 60 61 57 52 46 44 43 Inlet/Radiated 62 61 59 50 43 40 35 Discharge 49 49 46 39 32 26 23 Inlet/Radiated 51 50 48 38 28 22 18 Discharge 51 51 48 42 35 30 25 Inlet/Radiated 53 52 50 40 30 25 19 20 20 20 Discharge 54 54 51 45 39 35 31 Inlet/Radiated 56 55 53 44 35 31 23 Discharge 56 55 52 47 40 37 34 Inlet/Radiated 57 56 54 45 36 32 25 Discharge 59 58 55 51 45 42 40 Inlet/Radiated 61 59 56 48 40 37 31 20 20 20 Discharge 53 53 51 44 38 33 28 Inlet/Radiated 57 55 52 43 34 29 20 Discharge 55 54 52 45 39 35 31 Inlet/Radiated 58 56 53 44 35 31 22 Discharge 57 56 53 47 41 37 34 Inlet/Radiated 60 57 54 45 37 33 25 20 20 20 Should a Guide NR level be required, then an acoustic assessment will be needed. 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 8 Cheetah Fan Coil Unit Technical Data Construction Code Description Models Inlet Plenum Options 0 Vertical AC Unit G Fresh air - unlined 1 Vertical EC Unit H Fresh air - lined 2 Horizontal AC Unit I 200mm spigot return air - unlined 3 Horizontal EC Unit J 250mm spigot return air - unlined K 315mm spigot return air - unlined L 200mm spigot return air - lined M 250mm spigot return air - lined N 315mm spigot return air - lined Discharge Configuration C Core Unit only 0 Core Unit + plenum with Ø200mm spigots 5 Core Unit + plenum with Ø250mm spigots 8 Core Unit + plenum with Ø315mm spigots 3 Prestige rectangular 1 Rectangular (vertical units) Controls Number of Fans 2 0 A Standard speed control B Free issue heating or cooling only Three row coil C Free issue heating and cooling 4 Four row coil D Stand alone heating or cooling only 5 Five row coil E Stand alone heating and cooling 1 One fan unit 2 Two fan unit 3 Three fan unit 3 4 Four fan unit 5 Five fan unit 1 / B Coil Style 3 6 / B 5 N F P T Y E W B Basic waterside B Heating & Cooling U Uncased (chassis) waterside C Cooling only F Filter extension C Cased waterside H Heating only P Standard condensate pump T Traffolyte label Y Painted drain tray E Electric heater S Peristaltic condensate pump W Shrink wrap Coil Operating Mode Configuration 3 300mm attenuator 6 600mm attenuator 9 900mm attenuator Inlet Attenuator 3 300mm attenuator 6 600mm attenuator 9 900mm attenuator / A X Options X Any special features Special Features Discharge Attenuator 0118 918 6470 · www.caice.co.uk · [email protected] · Follow @caiceUK 9 Important Information All published specifications within this document were accurate as of 19 September 2014. As part of our policy of continuous product improvement we reserve the right to change the specifications of our products without prior notice. Our latest product specifications are available from our web site. Telephone 0118 918 6470 Facsimile 0118 918 6480 [email protected] www.caice.co.uk Caice Acoustic Air Movement Ltd. Riverside House 3 Winnersh Fields Gazelle Close Winnersh Wokingham RG41 5QS Registered office and head office Company Registration Number 2790667 VAT Registration Number GB614683632
© Copyright 2024 ExpyDoc