Download - Focal Point Lights

Covelight 47/58
™
FLUORESCENT
DIMENSIONAL DATA
FEATURES
FCV 47
FCV 58
Multiple lamp configurations provide maximum flexibility.
3.00"
76.2mm
4.50"
114.3mm
4.00"
101.6mm
8.00"
203.2mm
7.00"
177.8mm
3.75"
95.3mm
High performance indirect luminaire designed for concealed
cove applications.
Continuous run lengths may be configured with combinations
of luminaire lengths up to 8’.
Covelight™ provides pleasing and even illumination that
highlights architectural details.
lamping options
fcv 47
T8 LAMPS
BIAX LAMPS
PERFORMANCE
PRODUCT OVERVIEW
fcv 58
Lumen Output: 2000-13008lm
Wattage:18-95W
BIAX LAMPS
Lamping:
Biax, T8
1–Lamp T8
72.5% Efficient
1254 cd @ 125˚
Visit focalpointlights.com for complete photometric data.
Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlight
July 2014 C
fixture:
project:
ORDERING
DETAILS
Luminaire Series
Covelight
Profile
4" x 7"
5" x 8"
fixture lengths
fcv47
fcv58
24.00"
24.00"
2'
Lamping
40 Watt Biax
50 Watt Biax
55 Watt Biax
2'
36.00"
36.00"
3'
3'
48.00"
48.00"
4'
4'
60.00"
5'
72.00"
6'
84.00"
7'
96.00"
8'
SPECIFICATIONS
Construction
20 Ga. steel housing. 20 Ga. steel socket bridges and end caps. Luminaires are available
up to 8’ nominal lengths. 4’ unit weight: 13 lbs. 8’ unit weight: 23 lbs.
Optic
Die-formed .02” specular aluminum reflector.
Electrical
Luminaires are individually wired for specified circuits. Electronic ballasts are thermally
protected and have a Class “P” rating. Consult factory for dimming specifications and
availability.
Labels
UL and cUL listed.
Finish
Polyester powder coat applied over a 5-stage pre-treatment. Standard luminaire housing
finished in High Reflectance White.
Focal Point LLC reserves the right to change specifications for product improvement without notification.
(4" x 7" one lamp only)
(5" x 8" two lamp only)
FCV
47
58
BX40
BX50
BX55
One Lamp T8
Two Lamp T8
1T8
2T8
Circuits
Single Circuit
Dual Circuit
1C
2C
(T8 available on 4" x 7" only)
(Two lamps only)
Voltage
120 Volt
277 Volt
347 Volt
Ballast
Electronic Instant Start
(maximum <20% THD)
FCV
120
277
347
E
Electronic Program Start <10% THD S
Electronic Dimming Ballast* D
Mounting
Cove
CV
Factory Options
Emergency Circuit*
Emergency Battery Pack*
HLR/GLR Fuse
Include 3000K Lamp*
Include 3500K Lamp*
Include 4100K Lamp*
EC
EM
FU
L830
L835
L841
Finish
High Reflectance White
HW
Luminaire Length
Designate length in feet
XX'
(Nominal lengths: 2',3',4',5',6',7',8')
*For more information visit focalpointlights.com/reference or consult factory.
CV
HW
Covelight 47/58
™
FLUORESCENT
CANDELPOWER DISTRIBUTION
180° 170° 160° 150°
1255
0°
0˚
0
0
0
0
0
5˚
0
0
0
0
0
120°
15˚
0
0
0
0
110°
25˚
0
0
0
35˚
0
0
130°
1004
753
502
251
100°
Zonal
Lumens
%
Fixture
31.0
42.7
0
90°-130°
1253
44.0
60.7
0
0
90°-150°
1786
62.7
86.4
0
0
0
90°-180°
2051
72.5
99.3
0
0
0
0
2066
72.5
100.0
0
0
0
0
0
0
0
0
0
0
0
0
251
80°
65˚
0
0
0
0
0
0
502
70°
75˚
0
0
0
0
0
0
753
60°
85˚
78
56
9
0
0
15
90˚
238
211
139
47
0
95˚
440
411
324
181
8
164
105˚
805
766
644
364
35
316
115˚
1175
1109
840
425
77
402
125˚
1254
1114
819
448
120
371
135˚
1121
1021
788
463
166
307
145˚
921
849
673
440
208
226
155˚
760
701
579
408
240
150
165˚
570
540
469
375
262
88
175˚
376
364
336
309
272
27
180˚
283
283
283
283
283
0°
45°
90°
10°
20°
30°
40°
90°
45°
0°
72.5%
%
Lamp
55˚
0°
2066lm
Efficiency
883
45˚
1255
Lumens:
8968.2
Lumens
90°
50°
FCV471T8.IES
Test #:
90°-120°
90°
0
1004
Filename:
LUMEN SUMMARY
Horizontal Angle
22.5°
45°
67.5°
Vertical
Angle
140°
FCV-47-1T8-1C-120-E-HW-4’
Zone
Total
Luminaire 0°-180°
Go to www.focalpointlights.com for additional photometric data.
note: Photometric testing performed in an independent lab with standard lamps and ballasts. Lamp and ballast type and configuration will affect photometric performance.
Covelight
™
Fluorescent run Guide
Continuous Runs consist of standard fixture lengths. Some fixtures may exceed nominal length consult individual cut sheets for details.
Example: 31' run = three 8' fixtures and one 7' fixture.
Nominal run
length (in feet)
Standard fixture
lengths required
Lamp sizes
Nominal run
length (in feet)
Standard fixture
lengths required
Lamp sizes
2
2
2
32
8888
44444444
3
3
3
33
88863
444444333
4
4
4
34
88864
444444433
5
5
5
35
88883
444444443
6
6
33
36
88884
444444444
7
7
43
37
88867
4444444333
8
8
44
38
88886
4444444433
9
63
333
39
88887
4444444443
10
64
334
40
88888
4444444444
11
83
443
41
888863
44444444333
12
84
444
42
888864
44444444433
13
76
4333
43
888883
44444444443
14
86
4433
44
888884
44444444444
15
87
4443
45
888876
444444444333
16
88
4444
46
888886
444444444433
17
863
44333
47
888887
444444444443
18
864
44433
48
888888
444444444444
19
883
44443
49
8888863
4444444444333
20
884
44444
50
8888873
4444444444433
21
876
444333
22
886
444433
23
887
444443
24
888
444444
25
8863
4444333
26
8864
4444433
27
8883
4444443
28
8884
4444444
29
8876
44444333
30
8886
44444433
31
8887
44444443
Focal Point LLC | 4141 S. Pulaski Rd, Chicago, IL 60632 | 773.247.9494 | focalpointlights.com | @focalpointlight