Data sheet

Data sheet
Page: 1 / 6
Etaline GN 080-250/754 G11
Inline pump
Operating data
Requested flow rate
Requested developed head
Pumped medium
Ambient air temperature
Fluid temperature
Fluid density
Fluid viscosity
Suction pressure max.
Mass flow rate
Max. power on curve
Min. allow. flow for continuous
stable operation
Shutoff head
66.00 m³/h
20.00 m
Water
Clean water
Not containing chemical and
mechanical substances which
affect the materials
20.0 °C
20.0 °C
998 kg/m³
Actual flow rate
Actual developed head
Efficiency
MEI (Minimum Efficiency
Index)
Power absorbed
Pump speed of rotation
NPSH required
Permissible operating
pressure
65.99 m³/h
19.99 m
69.2 %
≥ 0.10
1.00 mm²/s
0.00 bar.g
18.29 kg/s
6.28 kW
13.88 m³/h
Discharge press.
Min. allow. mass flow for
continuous stable operation
Max. allow. mass flow
Design
1.96 bar.g
3.85 kg/s
24.46 m
5.18 kW
1476 rpm
2.28 m
16.00 bar.g
28.11 kg/s
Single system 1 x 100 %
Tolerances to ISO 9906 Class
3B; below 10 kW acc. to
paragraph 4.4.2
Design
Pump standard
Design
Orientation
Suction nominal dia.
Suction nominal pressure
Suction position
Suction flange drilled
according to standard
Discharge nominal dia.
Discharge norminal pressure
Discharge position
Discharge flange drilled
according to standard
Shaft seal
Manufacturer
Type
Material code
Without
Close-coupled in-line
Vertical
DN 80
PN 16
270° (left 90°)
EN 1092-2
DN 80
PN 16
90° (right)
EN 1092-2
Single acting mechanical seal
KSB
1
BQ1EGG
Shaft seal code
Sealing plan
11
I Single-acting mechanical
seal(internal circulation)
A liquid free of solids is assumed
Seal chamber design
Standard seal chamber
Contact guard
with
Wear ring
Casing wear ring
Impeller diameter
260.0 mm
Direction of rotation from drive Clockwise
Silicon free pump assembly
Yes
Bearing bracket construction Close-coupled
Bearing bracket size
WE35
Bearing type
Anti-friction bearings
Lubrication type
Grease
Color
Vermilion (RAL 2002)
Data sheet
Page: 2 / 6
Etaline GN 080-250/754 G11
Inline pump
Driver, accessories
Driver type
Drive standard mech.
Model (make)
Drive supplied by
Motor const. type
Motor size
Efficiency class
Motor speed
Frequency
Operating voltage
Rated power P2
Available reserve
Rated current
Starting current ratio
Insulation class
Electric motor
IEC
KSB
Standard motor supplied by
KSB - mounted by KSB
V1
132M
IE2 acc. to IEC 60034-30
1476 rpm
50 Hz
400 V
7.50 kW
44.82 %
14.7 A
6.9
F to IEC 34-1
Motor enclosure
Cos phi at 4/4 load
Motor efficiency at 4/4 load
Temperature sensor
Terminal box position
Motor winding
Number of poles
Fixed bearing reinforced
Connection mode
Motor cooling method
Motor material
Frequency inverter operation
allowed
Noise pressure level
IP55
0.83
88.7 %
3 PTC resistors
0° same orientation
Viewed from the drive
400 / 690 V
4
axial
Delta
Surface cooling
Aluminium
FI allowed
64 dBa
Materials GN
Notes
general criteria for a water analysis: pH-value >= 7; chloride
content (Cl) <=250 mg/kg. chlorine (Cl2) <=0.6 mg/kg.
Volute casing (102)
Grey cast iron EN-GJL-250
Discharge cover (163)
Grey cast iron EN-GJL-250
Shaft (210)
Tempered steel C45+N
Impeller (230)
Grey cast iron EN-GJL-250
Joint ring (411)
DPAF seal plate asbestos
free
Casing wear ring (502.1)
Casing wear ring (502.2)
Shaft sleeve (523)
Stud (902)
Screwed plug (903)
Impeller nut (922)
Grey cast iron GG/CAST
IRON
Grey cast iron GG/CAST
IRON
Stainless steel 1.4571
Steel 8.8
Steel ST
Steel 8
Page: 3 / 6
Etaline GN 080-250/754 G11
Inline pump
Curve data
Speed of rotation
Fluid density
Viscosity
Flow rate
Requested flow rate
Total developed head
Requested developed head
1476 rpm
998 kg/m³
1.00 mm²/s
65.99 m³/h
66.00 m³/h
19.99 m
20.00 m
Efficiency
MEI (Minimum Efficiency
Index)
Power absorbed
NPSH required
Curve number
Effective impeller diameter
Acceptance standard
69.2 %
≥ 0.10
5.18 kW
2.28 m
K1146.454/011
260.0 mm
Tolerances to ISO 9906
Class 3B; below 10 kW
acc. to paragraph 4.4.2
Installation plan
Page: 4 / 6
Etaline GN 080-250/754 G11
Inline pump
184
165
175
100
202
1)
45
140
45
1)
ø262
230
2)
45
50
619
ø300
1)
733
234
DN2
12.5
60
114
M10
DN1
1) Foundation fixing elements
2) Pump fixing elements
250
Drawing is not to scale
250
Dimensions in mm
Installation plan
Page: 5 / 6
Etaline GN 080-250/754 G11
Inline pump
Motor
Motor manufacturer
Motor size
Motor power
Number of poles
Speed of rotation
Position of terminal box
Note:
KSB
132M
7.50 kW
4
1476 rpm
0° same orientation
Viewed from the drive
Pump foot is not in the
scope of supply
Connect pipes without stress or strain!
Dimensional tolerances for shaft axis height:
Dimensions without tolerances, middle tolerances to:
Connection dimensions for pumps:
Dimensions without tolerances - welded parts:
Dimensions without tolerances - gray cast iron parts:
Connections
Suction nominal size DN1
Discharge nominal size DN2
Nominal pressure suct.
Rated pressure disch.
Weight net
Pump
Motor
Total
DIN 747
ISO 2768-m
EN735
ISO 13920-B
ISO 8062-CT9
DN 80 / EN 1092-2
DN 80 / EN 1092-2
PN 16
PN 16
61 kg
49 kg
110 kg
For auxiliary connections see
separate drawing.
Connection plan
Page: 6 / 6
Etaline GN 080-250/754 G11
Inline pump
Connections
1M.1 Pressure gauge
connection
1M.2 Pressure gauge
connection
5B venting
6B.2 Pumped liquid drain
6B.3 Pumped liquid drain
6D.1 Pumped medium filling/venting
6D.2 Pumped medium filling / venting
Rc 3/8
Drilled and plugged.
Rc 3/8
Drilled and plugged.
Rc 3/8
Rc 3/8
Rc 3/8
Closed with venting plug
Drilled and plugged.
Drilled and plugged.
Drilled and plugged.
Rc 3/8
Drilled and plugged.