Redline Miniature Circuit Breakers Series Hti Circuit protection EN/IEC 60947-2 Applications Performance Standard / Marking (A) 80-100-125 (V) 230/400 3-5 In (B) 5-10 In (C) 10-20 In (D) Mechanical/electrical endurance 10000/4000 Operating temperature (°C) -25°C up to 55°C Terminal capacity flexible/rigid cable (mm2) 70 Poles 1, 2, 3, 4 Weight (g/pole) 210 Thermal setting In Rated voltage AC Un Tripping characteristics A B EN/IEC 60947-2 C D E 10kA Add-on devices Short-circuit capacity Acc. to EN/IEC 60947-2 (B, C) Poles V Add-on RCD 1 2 3, 4 3, 4 F G 230/400 230 230 400 Icu (kA)(1) 10(2) 15(3) 15(3) 10(2) Add-on RCD - technical performances Auxiliaries X Tele L Add-on RCD Auxiliary contacts Shunt trip CA pg A.34 pg A.35 pg A.35 EN/IEC 60947-2 (A) 80-125 (mA) 30, 300 (V) 2P: 230/400 3P-4P: 400 Resistance against unwanted tripping Type A, AC: 250A 8/20 µs Type S: 3000A 8/20 µs Terminal capacity flexible/rigid cable (mm2) 70 Poles 2, 3, 4 Standard Nominal current In Residual current I∆n Rated voltage AC Un (1) Only for 3-5 In (B) and 5-10 In (C) (2) 7.5kA for 10-20 In (D) (3) 10kA for 10-20 In (D) More technical data Dimensions A.32 website pg A.81 Redline Series Hti - 10kA - characteristics B-C-D In (A) 3-5 In (B) Cat. No. Ref. No. 5-10 In (C) Cat. No. Ref. No. 10-20 In (D) Cat. No. Ref. No. Pack. Hti 101 B080 Hti 101 B100 Hti 101 B125 671504 671505 671506 Hti 101 C080 Hti 101 C100 Hti 101 C125 671528 671529 671530 Hti 101 D080 Hti 101 D100 Hti 101 D125 671552 671553 671554 8 1 1 2P 3 mod. 80 100 125 Hti 102 B080 Hti 102 B100 Hti 102 B125 671510 671511 671512 Hti 102 C080 Hti 102 C100 Hti 102 C125 671534 671535 671536 Hti 102 D080 Hti 102 D100 Hti 102 D125 671558 671559 671560 4 1 1 Series Hti 1P 1.5 mod. 80 100 125 A 3P 4.5 mod. 80 100 125 Hti 103 B080 Hti 103 B100 Hti 103 B125 671516 671517 671518 Hti 103 C080 Hti 103 C100 Hti 103 C125 671540 671541 671542 Hti 103 D080 Hti 103 D100 Hti 103 D125 671564 671565 671566 1 1 1 B C D E 4P 6 mod. 80 100 125 Hti 104 B80 Hti 104 B100 Hti 104 B125 671522 671523 671524 Hti 104 C080 Hti 104 C100 Hti 104 C125 671546 671547 671548 Hti 104 D080 Hti 104 D100 Hti 104 D125 671570 671571 671572 1 1 1 F G X Only for 3-5 In (B) and 5-10 In (C) For D see page A.32 A.33 Redline Series Hti - Add-on RCD - Type AC Circuit protection 30 mA 300 mA In (A) Cat. No. Ref. No. Cat. No. Ref. No. 2P 6 mod. 80-125 DOC 2125/030 671574 DOC 2125/300 671576 Pack. 1 3P 6 mod. 80-125 DOC 3125/030 671582 DOC 3125/300 671584 1 4P 6 mod. 80-125 DOC 4125/030 671590 DOC 4125/300 671592 1 A Series Hti - Add-on RCD - Type A 30 mA B 300 mA In (A) Cat. No. Ref. No. Cat. No. Ref. No. Pack. 3P 6 mod. 80-125 DOCA 3125/030 671581 DOCA 3125/300 671583 1 4P 6 mod. 80-125 DOCA 4125/030 671589 DOCA 4125/300 671591 1 C D E F Series Hti - Add-on RCD - Type S S 30 mA G 300 mA In (A) Cat. No. Ref. No. Cat. No. Ref. No. Pack. 3P 6 mod. 80-125 - - DOCS 3125/300 671585 1 4P 6 mod. 80-125 - - DOCS 4125/300 671593 1 X On demand: 2P type A and S A.34 Redline Series Hti - Auxiliary contacts (right side) Description Mod. Cat. No. Ref. No. Pack. Auxiliary contact H 1/2 Hti H 671597 1 Signal contact S + test + reset S 1/2 Hti S 671598 12 H/S 1/2 Hti H/S 671599 1 H+H/S 1/2 Hti HH/HS 671600 1 H+S 1/2 Hti HSR 671602 1 Changeable auxiliary/signal contact Auxiliary contact and changeable auxiliary/signal contact Auxiliary contact and signal contact H + S + test + reset A B Series Hti - Auxiliary contacts (left or right side) 1 mod. Series Hti Functions Rated voltage Closing current Operating time Coil impedance at 50Hz 110 to 415V 110 to 125VDC 0.3A at 110V 0.6A at 230V 1A at 400V 10 ms 4ms 2ms ca. 29 Ohm ca. 29 Ohm ca. 29 Ohm Cat. No. Ref. No. Pack. TELE L 110 624945 8 C D E 1 mod. 24 to 48VDC 24 to 60V 1A at 24VDC 2A at 48VDC 10ms 4ms ca. 24 Ohm ca. 24 Ohm TELE L 24 624946 8 F G X A.35
© Copyright 2024 ExpyDoc