. Mini City Direct HTC Heating and domestic hot water substation for apartments and single family houses The Mini City heating substation is ready for installation to meet the complete central heating and hot water requirements. It is suitable for apartments and single-family houses that are direct connected to a heating network. Alfa Laval has many years of experience in district heating technology, which is put to expert use in the Mini City, resulting in its practical functionality and ease of use. All components are easily accessible for inspection and future servicing when required. Comfort The Mini City HTC is the step-in model of the Mini City family. It has an automatic individual temperature setting for hot water. Mini City is fully prepared for individual temperature control for central heating by its valve and actuator. Domestic hot water is heated separately in a high capacity heat exchanger, this ensuring that the hot water is always as fresh as the incoming cold water main supply. Simple installation Compact dimensions, light weight, well arranged plumbing and ready for correction to individual temperature control for heating. Long-term security The Mini City represents the most modern technology, and provides the answer to stringent demands for long-term performance. The heat exchanger plates and all piping are manufactured in acid-resistant stainless steel. All components are closely matched and carefully tested for function in accordance with Alfa Laval’s quality assurance system ISO 9001:2008. Mini City HTC follows PED 97/23/EC. Components 1. Heat exchanger for hot water 3 1 2. Control valve for hot water 3. Hot water thermostat 7 4. Control valve for heating circuit 8 5. Actuator for heating circuit 6 6. Differential pressure controller 7. Temperature sensor connection, heating network medium supply 8. Filter for heating network medium 2 5 9. Adapter for energy meter 10. Check valve for cold water 4 9 11. Safety valve for domestic hot water 11 12. Shut-off valves (6 pcs) 10 13. Heating network media, supply 14. Heating network media, return 15. Cold water (cw) 16. Hot water (hw) 17. Heating circuit, return 13 14 15 16 17 18 18. Heating circuit, supply Brass parts are hardened against dezincification. All connectors, DN20, internal threaded. .. Heating network – a good source of heat A heating network is an efficient technology that meets the need for central heating and hot water in a simple, convenient and secure way. Operation Mini City is used for the direct connection of apartments and single family houses to the heating network. With this kind of connection, the heating water from the mains network is used for heating the radiator system of the apartment or single family house. For connection to underfloor heating system, the unit should be completed with a special control equipment, suited for this purpose, or use Alfa Laval Mini City Direct STC. A heat exchanger is used to transfer heat from the heating network medium to the hot water system. Heat is transferred through a package of thin, acid-resistant, stainless steel plates, which keeps the heating network medium separate from the domestic hot water system. Mini City is fully prepared for individual temperature control for central heating by its valve and actuator. With an external room controller installed, the heating circuit is adjusted in relation to the room temperature via a thermostatic control. A self-sensing temperature regulator controls the hot water temperature. This measures the temperature of the hot water in the heat exchanger and automatically adjusts the outgoing flow. The energy supplier registers the use of energy. Measurement is done by recording the flow of heating network medium through the system, and by measuring the temperature difference between the medium’s supply and return flow. Diagrammatic flow chart for Mini City Direct HTC .. 7 12 8 13 3 12 12 16 18 1 11 13 12 10 M 12 15 17 5 2 6 4 9 12 14 For underfloor heating systems Underfloor heating systems must be separately controlled. The instructions of the underfloor heating supplier must also be checked. ... An easily manageable, economical and durable source of heat The Mini City uses the heating network medium for heating the domestic hot water (providing an uninterrupted supply) as well as the water in the central heating system. The Mini City is a wall-mounted unit and is very compact. Wherever the unit is located, it is quiet and discreet, requires no attendance or maintenance and has a very long operational life. In the event of requiring servicing or component exchange at some future date, all parts are easily accessible and individually replaceable. . . Other information Operating data Electrical data: 230 V, single phase, 2 W Heating network Heating circuit Hot water circuit Design pressure, MPa 1.0 1.0 1.0 Dimensions (substation): 413 mm width x 211 mm depth x 713 mm height Design temperature, °C 100 - 100 Weight: 15 kg, casing 5 kg Relief valve opening pressure, MPa 100 - 0.9 0.35 - Transport particulars: Total weight 28 kg, 0.2 m³ Volume, l 0.34 Dimensions (cover): 422 mm width x 330 mm depth, 728 mm height Connections Screws Performance at available primary differential pressure 50-400 kPa Heating network media supply G ¾ Designed temperature programme (°C) Heating network media return G ¾ Heating circuit supply G ¾ Heating circuit return G ¾ Capacity (kW) Primary flow (l/s) Actual Secondary return temp. flow (°C) (l/s) Hot water circuit 80-30/10-55 57 0.27 30 0.30 Cold water G ¾ 80-25/10-55 37 0.16 25 0.20 Hot water G ¾ 65-25/10-50 25 0.15 25 0.15 75-25/10-50 42 0.20 25 0.25 70-25/10-50 34 0.18 25 0.20 80-60 12 0.14 60 0.14 85-60 12 0.11 60 0.11 85-45 12 0.07 45 0.07 75-60 5 0.08 60 0.08 Heating circuit .... ISO 9001:2008 . ECF00364EN 1203 How to contact Alfa Laval Up-to-date AlfaLaval contact details for all countries are always available on our website on www.alfalaval.com Alfa Laval reserves the right to change specifications without prior notification.
© Copyright 2024 ExpyDoc