Contrel technology and safety in hospital segment A complete and performing range of products: a Contrel products range specific for medical locations, where operational continuity and reliability are key requirements for safety and protection of patients and medical staff. 1| Operational continuity in hospital segment Hospital products range A broaden range of reliable products to assure safety to patients and medical staff inside intensive care units, operating theatres, first aid and day hospital, ambulatories, dental care, nursing home. HRI-R40, insulating monitoring devices for 230 V a.c. IT-M circuits HRI-R24, insulating monitoring devices for 24 V a.c./d.c. circuits supplying scialitic lamps 2| Operational continuity in hospital segment PR-5, remote signaling panel with luminous and acoustic fault indicationsupplying scialitic lamps RMS-12, multiple rooms monitoring with LCD screen terminal Remote Monitoring System REMOTE ALARM AND DISPLAY PANEL Thanks to its display and communication terminals it is possible to control the status of a group of operating insulation monitoring device (from 1 to 12) from a single control room. ROOM 1 R Z T1 T2 I [kΩ] [kΩ] [°C] [°C] [A] 120 0 70 0 9.6 80 0 55 0 7.0 The personnel may verify the status of each insulation monitoring device and any alarm signaling in real time. It includes software which allows for very simple installation: no programming is necessary. The display allows visualizing: - - General page: it is possible immediately understand whether the system of each facility is functioning correctly or if, instead, it is suffering anomalies or damages. Measures page: summarizes in a single screen the real time, threshold measures (resistance, impedance, temperature of the transformer primary and secondary, current) and the alarm RMS-12 (low insulation; surpassed programmed threshold alarm) Alarm page: summarizes in a single screen the alarm RMS-12 presents (resistance, impedance, as well as any over temperature of the transformer primary and secondary and over current) Language page: it is possible to configure the device language: Italian, English, Spanish. Configuration page: it is possible to configure the system to be monitored (communication parameters, language) General page Measures Page ROOM 1-6 Room1 Room2 Room3 OK Room4 Room5 OK Room6 Alarm page ROOM 1 OK OK 3| Operational continuity in hospital segment R Z T1 T2 I [kΩ] [kΩ] [°C] [°C] [A] 120 0 70 0 5.0 80 0 55 0 10.0 ALARM ROOM 3 Resistence Impedence Temperature1 Temperature2 Current Link Failure OK OK OK OK With HRI-R40 and RMS-12 devices it is possible to keep under control electrical parameters of different medical locations from single control room, through Modbus-RTU network protocol and display screen terminals. 4| Operational continuity in hospital segment Remote Monitoring System Technical features The RMS-12 remote alarm indicator is used for: Indication and visualization of operating status and alarm messages Displaying measured values for monitoring Contrel HRI-R40 insulation’s supervisors with Modbus protocol. The RMS-12 is available for flush mounting. Function On its backlight display, the RSM-12 shows alarm messages and values parameters from all HRI-R40 devices connected on the network. In the event of an alarm message, the red alarm LED lights up and the message appears on the LCD display in plain text format. At the same time, there is an audible signal to distinguish alarm RMS-12. The RMS-12 can be used as a master device in all HRI-R40 networks. Display / Operating elements The RMS-12 LCD display features graphics characters. It supplies medical and technical personnel with information that is always clear and unambiguous, in order to help them to make decisions. Every alarm message appears spontaneously and additional alarm RMS-12 can be displayed at the touch of a button. Another additional line contains status information, such as number of messages or menu information. One LED is located below the LCD display which allow to distinguish between normal (no alarm RMS-12) and alarm messages. Four large buttons are available for operating the RMS-12. These buttons provide the following functions: Scrolling alarm texts and messages Scrolling measured values of all HRI-R40 devices Enter into menu parameters setting Applications indication and visualization of operating status and alarm messages central network status visualization of HRI-R40 devices displaying measured values of response values for monitoring purpose 5| Operational continuity in hospital segment Operating and display elements ROOM 1 R Z T1 T2 I 3 [kΩ] [kΩ] [°C] [°C] [A] 120 0 70 0 9.6 4 80 0 55 0 7.0 5 7 4 1. LCD: to display operating, measured values and alarm messages. 2. LED “ALARM”: alarm messages 3. Buzzer mute: in operating mode: to mute the buzzer in menu mode: ESC function 4. Scroll button: in operating mode: to scroll messages in menu mode: UP 5. Scroll button: in operating mode: to scroll messages in menu mode: DOWN 6. “ENTER button”: in operating mode: to scroll windows in menu mode: confirm function 7. “MENU” button: in operating mode: to call up the menu mode in menu mode: enter function 6| Operational continuity in hospital segment 1 2 6 4 Wiring diagrams - Serial connection Serial connection COM2 – RS485 COM1 – RS485 Wiring diagrams - Ethernet connection Serial connection Ethernet connection RJ45 COM1 – RS485 7| Operational continuity in hospital segment Web server embedded Functions The internal Ethernet interface can be used for communication, visualization and management. Flexible meter polling rules and customizable reading history storage. Integrated reporting and a data querying for reading data. Manual export of alarm history or measured values into CSV formats. RMS-12 are directly supported standard communication protocols (Modbus-TCP, FTP, SMTP). Device installations are operated by many people. Allowing one users to access/view/modify devices and resources (setup, reports…). Restricting a user’s access enabling read-only access to devices or reports. Reporting is indispensable Reporting is indispensable for applications and systems with highly develop data processing and analisys capabilities. It’s simple to build reports. You don’t have to program anything. First, you use the internal Log function to select the measures that I want to store. Reports are browsed and printed. • Data coming from hardware devices. • Reports exported to CSV file. • Logs selected by custom criteria. • Reports are downloaded from internal FTP. • Browse reports by using a PC. Automatically sending email with report Contrel ethernet devices send an automatic e-mail with a CSV file. The schedule outgoing value is from every 1 hour to 48 hours, weekly or monthly. An example of application is to send the report of alarm RMS-12. Automatic discovery Device Explorer is the utility to view and manage the devices. TCP-IP communication protocol support discovery mechanism and thus lets you connect most devices in “plug-and-play” style. Upload firmware through the network For Ethernet devices, upgrading firmware is a very simple and convenient process. This operation will take a very few seconds. Contrel provides a boot loader utility for firmware upgrade. Operating elements To access the configuration you must change the IP address of the PC. Follow the instructions at the bottom of the following manual Troubleshooting section. Open your browser (Internet Explorer, Firefox, Mozilla, Opera, etc. ..) and go at http://10.0.0.100/index.html Please enter the correct Username and Password for administrator access and press Login button. It’s possible to modify the Username and Password in the configuration of the device. 8| Operational continuity in hospital segment NETWORK SETUP IP-address: IP address associated to the device. Netmask: Subnet-mask of the device. Gateway IP-address: IP address of the gateway associated to the device. Port Number(0-65534): TCP port number for Modbus communication. TIME SETUP Date: specify the date in System Clock in dd/mm/yyyy format. Time: specify the time in System Clock in hh:mm format. COMMUNICATION SETUP Unit ID (01-247): specify the address modbus of the device. Communication Protocol: specify the communication protocol used. LOG SETUP Log Filename [.csv]: Choose the name of the file where you saved all data. You can view that file in the integrated FTP server application. Polling Saving Time: Select the saving time (every minimum 15 seconds to maximum 1 hour or daily, weekly, monthly) to save the measures periodically. If you select 15 minutes in practice, the device stores the value on the quarter hour (example: 14:15-14:30-14:45-15:00). 9| Operational continuity in hospital segment E-MAIL SETUP Report by e-mail: enable or disable the automatic sending of e-mail. Account Name: Enter the name of the account to which you have the POP access. Normally, it is the text in your email address before the "@" symbol. If you have trouble with it, please contact your ISP. Password: Enter the password of the account. From(sender): Enter the name of the account sender. To(receiver): Enter the name of the account receiver. Period: Select the value from 1 hour, 6 or 12 hours, weekly or monthly) to send your email account periodically. LOGIN ACCOUNT SETUP Device Name: Enter the name you want to assign to the mnemonic device. Username: Enter the new username to access at RMS-12 configuration. Password: Enter the new password to access at RMS-12 configuration. Username and password are set also for administration and a guest user. It always advisable to change the password of the device as the default password is public domain. 10| Operational continuity in hospital segment HISTORICAL VIEW The storage and processing of collected data is carried out by the engine-modbus inside of the device. The monitored measures are customized by the user. The user can select and store from 1 to 16 parameters between all those from the device. In this page is indicated the percentage of memory used. You can search in all the values stored. To save a data table to disk, highlight the CSV link, right-click, and then select "Save Target As." Make sure that you save the file as a CSV Text Document (rename the extension .html to .csv). 11| Operational continuity in hospital segment
© Copyright 2024 ExpyDoc