15 Minute Universal Multiplex Assay Platform BREAKTHROUGH UNIVERSAL MULTIPLEXING FOR FAST, EASY & ACCURATE TESTING The Maverick Detection System performs multiplexed label-free detection of protein binding events by measuring wavelength resonance shifts caused by surface binding on silicon photonic sensors, eliminating the need for fluorescent, luminescent, or radioactive labels used in other immunoassay formats. The Maverick Detection System is designed around a proprietary disposable consumable – the AutoArray – which contains 12 silicon chips, each with an array of patented Microring Sensors on its surface. The binding of proteins or antibodies to any of the microring sensors on the chip is detected in real-time and the results are simultaneously analyzed with accompanying Genalyte software. 4 Independent Sensors per Analyte nne Cha ple Sam Sa mp le Ch l1 an ne l2 16 Analytes per Sample Channel 2 Sample Channels per Chip Each of the 12 chips in the AutoArray contain two independent sample channels. Each sample channel contains 16 sensor spots, enabling up to 24 samples to be tested against 16 analytes, or 12 samples tested against 32 analytes per kit. THE MAVERICKTM ADVANTAGE SPEND TIME DOING RESEARCH NOT ASSAYS Simple & Easy To Use SMALL SAMPLE VOLUME Automated workflow requires minimal hands-on time and reduces or eliminates the multiple washes, incubations, or additional steps typical of other technologies. On-board fluidics ensure assays are performed the same way every time, reducing the opportunity for variation and thereby lowering CV%. 5-10µL sample volume extends the use of precious samples. RESULTS IN ONLY 10 MINUTES First results are reported in as little as 10 minutes. That’s over 10x faster than traditional ELISA and light speed ahead of bead-based technology. LABEL-FREE TECHNOLOGY Enables kinetic screening and affinity measurements of multiple interactions. THE MAVERICKTM SILICON PHOTONIC CHIP The key to the Maverick Detection System is its patented silicon chip containing arrays of Microring Sensors that can simultaneously analyze multiple proteins from a single sample. HOW IT WORKS 1. Each microring sensor on the chip is coated with a distinct antigen or antibody which enables multiplexing. 2. An infrared laser generates light in a broad wavelength range which traverses waveguides on the chip surface. 3. Each ring resonates at a particular wavelength causing only that wavelength to be trapped in the ring while all others continue on to a photodetector. This results in a measurable “notch” in the spectrum detected by the instrument. 4. As material binds to the sensor surface the wavelength of required for resonance within the ring changes, causing the “notch” to move (resonance shift). 5. The resonance shift changes proportional to the amount of material bound to the ring surface. This shift is monitored in real-time by the Maverick instrument and results plotted in picometers of wavelength shift over time - Genalyte Response Units (GRU). Time (minutes) THE MAVERICKTM ASSAY KIT Maverick assay kits include an AutoArray, a Reagent Plate, and a USB drive. The USB drive contains the assay protocol(s) and is linked to the AutoArray and Reagent Plate via barcode. This enables the instrument to track chip and reagent well usage allowing partial kits to be used without danger of accidentally reusing a chip or well. It also prevents incompatible kit components from being used. Sample Channel 1 2 Chip 1 1 9 17 2 10 18 3 11 19 4 12 20 5 13 21 6 14 22 7 15 23 8 16 24 The reagent plate is mapped out by chip and the number of wells required to hold the reagents specified by the protocol. The reagent plate comes with all necessary reagents preloaded into the appropriate wells. Test samples are added to the numbered wells. Each AutoArray contains 12 Maverick silicon photonic chips. Each of the 24 sample channels (2 per chip) uses dedicated fluidics, providing the capacity the to test 24 samples. Dedicated fluidics for each sample 1 2 3 4 5 6 7 8 9 11 13 15 17 19 21 23 10 12 14 16 18 20 22 24 EASY TO OPERATE 1. load sample 2. pipette to mix 3. insert usB, autoarray, and reagent plate into Maverick 4. press start. instrument automation moves autoarray and reagent plate as directed by assay protocol , testing up to 24 samples with no human interaction APPLICATIONS ISOTYPED IMMUNOGENICITY TESTING MaverickTM Multi-Tier Anti-Drug Antibody Assay (MT-ADA) Screen, Confirm and Isotype Anti-Drug Antibodies in One Assay The Maverick™ MT-ADA assay streamlines immunogenicity testing by combining screening, confirmation, and isotyping into a single assay providing real-time detection of anti-drug antibodies (ADA) without the use of fluorescent probes or radioactive labels. The sensor spots on the assay chip are functionalized with anti-isotype capture antibodies. This design provides simultaneous ADA screening and confirmation of eight classes/isotypes in the same assay without additional effort or reagents. The inherent multiplexing capability of the Maverick also speeds assay development by enabling assessment of assay sensitivity and free drug tolerance for total ADA and multiple classes/isotypes simultaneously. Streptavidin Coated Bead Biotinylated Drug Sam ple Sa mp Cha le nne Ch l1 an ne l2 IgG3 IgG2b IgG2a IgG1 IgE IgA IgM IgX 2 1 The isotype capture assay format allows both drug binding sites on the ADA to be potentially available for labeled drug binding. This enables the MT-ADA assay to generate a signal with a single drug molecule bound to the ADA as compared to a traditional bridging assay which requires labeled drug to bind to both sites. Anti-IgG1 Capture Ab Maverick MT-ADA Sensorgram 1400 Igx IgG1 1000 800 600 IgG3 400 IgG2a IgM 200 IgG2b IgE, IgA 0 -200 4 Running Buffer 6 8 10 12 Running Buffer Time (minutes) Running Buffer Wash Buffer 2 Running Buffer Genalyte Response Units (GRU) 1200 0 Sample Confirmation w/ SA Beads ADA (IgG1) To demonstrate assay functionality, mouse monoclonal antibodies of known isotype against human insulin were used to represent ADA and biotinylated insulin was used to represent the drug. Known concentrations of ADA were spiked into a buffer sample and combined with biotinylated drug using equilibrium binding and acid dissociation methods. Detection of ADAs with concentration varying by isotype is demonstrated in the sensorgram to the left. MULTIPLEX ANTIBODY DETECTION IN MULTIPLE MATRICES The Maverick performs assays in multiple complex matrices such as serum, plasma, whole blood and crude extracts, minimizing sample preparation. Serum A multi-positive ENA serum sample tested on the Maverick ENA-7 assay kit diluted 1:50 in buffer. Surfaces of individual sensor spots are functionalized with SLE-related autoantigens. 400 Antibody Antigen 350 Genalyte Response Units (GRU) Anti-IgG Jo-1 Anti-Human IgG (Pos Control) SS-A60 SS-B 300 250 Scl-70 SS-A52 200 150 100 RNP Smith 50 0 0.0 2.0 4.0 Time (minutes) 6.0 8.0 Cell Culture Media Supernatant from a hybridoma culture producing mouse IgG1 monoclonal antibodies was tested with a Maverick Mouse MT-ADA assay kit using an alternate protocol. Biotinylated rat αnti-mouse kappa light chain antibody and streptavidin beads were used for signal amplification. Streptavidin Bead Sensors 1400 Biotinylated Rat aMouse Kappa Light Chain 1200 1000 IgG1 Mouse Monoclonal Ab Anti-IgG1 Capture Ab 800 600 400 200 0 0 2 4 Crude Extracts Demonstration of the use of the Maverick to detect Bean Pod Mottle Virus (BPMV), a common viral pathogen in soybean crops. The graph shows sensor response to diluted (1:200) leaf extracts from BPMV infected and healthy soybean plants. 6 8 Time (minutes) 10 12 14 16 The sensor surface was functionalized with anti-BPMV antibody. Leaf extract samples were prepared by grinding approximately 100 mg of leaf material in a mortar and pestle with 1 mL of BSA–PBS buffer until homogeneous. Solid plant debris was removed via centrifugation. Source: M.S. McClellan et al., Biosensors and Bioelectronics 31 (2012) 388-392 RAPID ASSAY DEVELOPMENT I1 I9 I2 I10 I3 I11 I4 I12 I5 I13 I6 I14 d I8 Use PI Not Capture Ab De All pair-wise combinations of 15 insulin antibodies were evaluated as both capture antibody (spotted on chip) and biotinylated detection antibody (in reagent plate). The analyte (insulin), buffer conditions, and secondary (streptavidin coated beads) were the same for all assays. te c An tion al A yt b Bu e ffe Be r ad s( se co nd ar y ) The Maverick’s onboard AutoArray and Reagent Plate automation enable rapid testing of multiple assay conditions in a single run, streamlining assay development. The contents of each well will pass over all sensors in the corresponding sample channel of its designated chip, allowing multiple combinations to be tested at once. The design of the Maverick AutoArray (12 chips x 2 sample channels x 16 sensor spots) enables an assay developer to test up to 24 different analytes and/or 24 different buffer conditions against up to 16 different probe molecules in a single run. Genalyte’s custom spotting service can economically functionalize assay chips with client probe molecules and provide fully assembled AutoArrays. The open reagent plate format allows a user to load reagents of their choice into the reagent wells. Guidance is provided by a plate map automatically generated by the Maverick Protocol Editor software based on the assay protocol designed by the user. Screening of Antibody Pairs in Development of a Quantitative Insulin Assay I7 The top candidate pairs (yellow in table, left) clearly stand out on the real-time sensorgrams (lower right). Dose curves for the top two candidate pairs lead to a clear winning combination (lower left). Real-Time Sensorgrams for Top 2 Pairs DESIGN YOUR OWN PROTOCOLS Maverick Protocol Editor software simplifies assay development by enabling researchers to design their own protocol or edit an existing protocol for any Maverick assay kit. The software generates a reagent plate map based on the protocol to guide the user in loading reagents. Create/modify reagent list Reagent list populates Specify reagent flow Software calculates drop down menu to add rate and duration required well volume additional protocol steps DIMENSIONS Length 17.75 in / 45 cm Width 15 in / 38 cm Height 21 in / 53 cm WEIGHT 87 lb / 39 kg POWER REQUIREMENTS 110/220 volt compatible SCALABLE Link systems for increased throughput ORDERING INFORMATION 85000 Maverick M24 Detection System 85001 Maverick M24 XM Expansion Unit To place an order please call 858-956-1200 [email protected] Genalyte 11095 Flintkote Ave Suite A San Diego, CA 92121 Research Use Only Genalyte, Inc. | 858.956.1200 | [email protected] | www.genalyte.com Maverick is a trademark of Genalyte | © 2013 Genalyte 150008 rev 1
© Copyright 2024 ExpyDoc