www.sylvania.com QUICKTRONIC® PROStart® T5HO UNV High Ambient Temp. Systems Type CC Programmed Rapid Start Systems Normal Ballast Factor HT Professional Series Q T P T 5H O PSN H T Lamp / Ballast Guide 54W T5HO - PENTRON lamps 1 or 2 lamp QTP2x54T5HO/UNV PSN HT 4 lamp Switchable: QTP4x54T5HO/UNV PSN HT W Also operates: FP54/SS, FT50DL, FT55DL, FPC55, L58T8 1 or 2 lamps on 2L ballast 1, 2, 3, or 4 lamps on 4L ballast ® Key System Features • • • • • • • • • • • • • • • 9 0°C maximum case temp. Universal voltage (120-277V) Low-profile (1.00” High) 100% ballast factor (see table) QUICKSENSE ballast technology (end-of-lamp-life sensing) PROStart programmed rapid start UL type CC rated -20°F (-29C) Min. Starting Temp. Operates at >42 kHz to reduce potential interference with infrared control systems High power factor Low harmonic distortion Lightweight UL, CSA, FCC RoHS compliant Lead-free solder, printed circuit board and manufacturing process Application Information SYLVANIA QUICKTRONIC T5HO HT ballasts are ideally suited for: • Industrial high-bay • Commercial • Retail • Hospitality • Institutional • New construction • Direct lighting • Indirect lighting • Surface mount • Cove lighting ECS429 - 6-13 SYLVANIA QUICKTRONIC PROStart T5HO High Ambient Temperature (HT) electronic ballasts operate PENTRON HO, PENTRON HO Circline, and DULUX® L T5 lamps with full lumen output and optimal system performance. The ballasts are available in two and four lamp models to cover a wide range of applications. These QUICKTRONIC PROStart T5HO ballasts are specifically designed for applications where the ballast is subjected to higher ambient temperatures, as in high bay industrial installations. The four lamp UNV (120-277V) ballast system provides 18,600 mean lumens, which, when factoring in lumen maintenance and typical T5HO fixture efficiency, can be considered as a direct replacement for standard 400W MH. As such, the family is ideally suited to replace 250W to 400W metal halide installations. Unique to the family is the 120-277V 4-lamp “switching” ballast, designed to switch from 4- to 2-, 3- to 2-, 3- to 1- or System Information QUICKTRONIC PROStart T5HO HT ballasts operate on 120V through 277V, 50/60 Hz current, eliminating “wrong voltage” wiring errors and reducing the number of ballast models in inventory by half. PROStart programmed rapid starting provides optimum starting conditions to yield up to 100,000 switching cycles for use on occupancy sensors and building control systems. Customers should always consider upgrading to our High Efficiency Systems to maximize energy savings. QUICKSENSE ballast technology helps to protect against overheated bases and sockets, as well as cracking of the lamp glass wall, and uses dynamic end-of-lamp-life sensing to avoid false shutdowns caused by some static sensing methods. QUICKSENSE ballast technology will auto reset when spent lamps are replaced with new ones. 2- to 1-lamps. The switching feature can be accessed through a second input power terminal. This feature allows for a range of control interfaces, including an occupancy sensor, mounted inside a fixture. circuit boards and manufacturing process. Setting the standard for quality, QUICKTRONIC PROStart T5HO HT systems are covered by the QUICK 60+® warranty, the first and most comprehensive system warranty in the industry. These ballasts are also RoHS compliant and feature lead-free solder, printed System Type Input System Initial MeanRelative Energy Power Fixture*Fixture*Fixture* Savings (W) LPW Lumens Output (%) M400/U (1-lamp) Magnetic Ballast 452 61 FP54T5HO (4-lamps) QTP4x54T5HO/UNV PSN-HTW 236 76 16,74094% 48% FP54/50W/SS (4-lamps) QTP4x54T5HO/UNV PSN-HTW 215 85 17,07596% 52% FP54/47W/SS (4-lamps) QTP4x54T5HO/UNV PSN-HTW 200 84 15,62588% 56% 17,784Baseline Baseline *Based on Fixture Efficiency: 76% for M400 and 90% for FP54T5HO *277V input voltage *Lumen Output for T5HO @ 35°C/95°F 120% 100% Relative Fixture* Output 100% 100% 88% 48% Energy Savings 80% 60% System Power (%) 96% 94% 52% 52% Energy Savings 48% 40% 56% Energy Savings 44% 20% 0% M400/U (1-lamp) Magnetic Ballast FP54T5HO (4-lamp) QTP 4x54T5HO/UNV PSN-HTW FP54/50W/SS (4-lamp) QTP 4x54T5HO/UNV PSN-HTW FP54/47W/SS (4-lamp) QTP 4x54T5HO/UNV PSN-HTW SPECIFICATION DATA Catalog # Date Project Prepared by 2 LAMP T5HO UNV HT Type Fixed Output Ballast Professional Series Comments Lamp / Ballast Guide 2 Lamp, Type CC, High Ambient, Universal Voltage (120-277V) Q T P T 5HO PSN HT High ambient model (90°C case temp.) 49136 QTP 2x54T5HO/UNV PSN HT Wiring diagram for 2-Lamp model Installation Notes • Install in accordance with National & Local Electric Code • Ground ballast case • Switching: Simultaneously disconnect all ungrounded line conductors • Insulate unused leads for 600V 2-Lamp model can be wired for one lamp operation. Item Number 49136 QTP 2 x 54 T5HO / UNV PSN HT High Ambient Temperature (Case) QUICKTRONIC PROFESSIONAL Starting/Ballast Factor Number of Lamps (1, 2) Line Voltage (120-277V) Primary Lamp Wattage Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com SPECIFICATION DATA Catalog # Date Project Prepared by 4 LAMP T5HO UNV HT Type Switchable Ballast Comments Professional Series 4 Lamp, Type CC, High Ambient, Universal Voltage (120-277V) Switching Schematics 4-Lamp Switching Wiring Diagram (4L to 2L) S2 (Output B) Closed (ON) Open (OFF) Closed (ON) Open (OFF) Lamp Control All 4 Lamps ON (Output A&B ON) 2 Lamps ON (Output A ON) 2 Lamps ON (Output B ON) All Lamps OFF Q T P T 5HO PSN HT S1 (Output A) Closed (ON) Closed (ON) Open (OFF) Open (OFF) Output A S1 S2 (Red Switching Line) Output B High ambient switchable model (90°C case temp.) 49161 QTP 4x54T5HO/UNV PSN HT W Installation Notes 3-Lamp Switching Wiring Diagram (3L to 2L, 3L to 1L) S1 (Output A) Closed (ON) Closed (ON) Open (OFF) Open (OFF) S2 (Output B) Closed (ON) Open (OFF) Closed (ON) Open (OFF) Lamp Control All 3 Lamps ON (Output A&B ON) 2 Lamps ON (Output A ON) 1 Lamp ON (Output B ON) All Lamps OFF Output A S1 S2 (Red Switching Line) • Install in accordance with National & Local Electric Code • Ground ballast case • Switching: Simultaneously disconnect all ungrounded line conductors • The AC line inputs must be connected to the same phase of the line voltage • DO NOT CONNECT two separate phases of line voltage to the input of the ballast Output B Input wiring for non-switching operation (Install jumper between black & red switching line terminals) 2-Lamp Switching Wiring Diagram (2L to 1L) S1 (Output A) Closed (ON) Closed (ON) Open (OFF) Open (OFF) S2 (Output B) Closed (ON) Open (OFF) Closed (ON) Open (OFF) Lamp Control 2 Lamps ON (Output A&B ON) 1 Lamp ON (Output A ON) 1 Lamp ON (Output B ON) All Lamps OFF S1 S2 (Red Switching Line) Item Number 49161 QTP 4 x 54 T5HO / UNV PSN HTW Input wiring for occupancy sensors (Install occupancy sensor/switch between black & red line terminals) Output A Output B High Ambient Temperature (Case) QUICKTRONIC PROFESSIONAL Starting/Ballast Factor Number of Lamps Line Voltage (120-277V) Primary Lamp Wattage OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com Normal Ballast Factor SPECIFICATION DATA Catalog # Date Project Prepared by T5HO PROStart Type ® Professional Series Comments Performance Guide Type CC, High Ambient, Universal Voltage (120-277V) InputRated1Ballast1 Input1System CurrentLamp1 Lumens No. of Factor System1Mean1 Power (W) Efficacy (AMPS) Type (lm) Lamps (BF) Lumens Lumens 120V 277V (lm/W) BEF2 QTP 2x54 T5HO Fixed Output BF 1.0 QTP2x54T5HO/UNV PSN-HT 1.00/0.43 FP54T5HO 5000 0.96/0.41 FP54/50W/SS 5000 0.89/0.38 FP54/47W/SS 4575 2 2 2 1.00 1.02 1.02 10,000 10,200 9335 9300 9485 8680 121 115 106 118 112 103 85 91 91 0.85 0.91 0.99 0.53/0.24 FP54T5HO 5000 0.50/0.21 FP54/50W/SS 5000 0.45/0.21 FP54/47W/SS 4575 1 1 1 1.05 1.05 1.03 5250 5250 4710 4885 4885 4380 62 59 54 61 58 53 86 91 89 1.72 1.81 1.94 49161 QTP4x54T5HO/UNV PSN-HTW 2.05/0.90 FP54T5HO 5000 1.85/0.80 FP54/50W/SS 5000 1.72/0.75 FP54/47W/SS 4575 4 4 4 1.00 1.02 1.02 20,000 18,600 241 20,400 18,970 221 18,665 17,360 205 236 215 200 85 95 93 0.42 0.47 0.51 1.51/0.65 FP54T5HO 5000 1.46/0.62 FP54/50W/SS 5000 1.34/0.58 FP54/47W/SS 4575 3 3 3 1.00 1.04 1.04 15,000 13,950 183 15,600 14,510 175 14,275 13,275 161 181 170 158 83 92 90 0.55 0.61 0.66 1.00/0.45 FP54T5HO 5000 0.95/0.42 FP54/50W/SS 5000 0.88/0.39 FP54/47W/SS 4575 2 2 2 1.00 1.03 1.03 10,000 10,300 9425 9300 9580 8765 121 114 105 118 111 104 85 93 91 0.85 0.93 0.99 0.51/0.25 FP54T5HO 5000 0.50/0.25 FP54/50W/SS 5000 0.47/0.25 FP54/47W/SS 4575 1 1 1 1.00 1.06 1.06 5000 5300 4850 4650 4930 4510 61 60 55 61 58 54 82 91 90 1.64 1.83 1.96 QTP 4x54 T5HO Switchable Model 1 At 35°C lamp ambient temperature. 2 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 3 System Efficacy calculation based on lowest input power value *(Item Number) = Item Number/NAED in parentheses are models with leads/wires. Ballast with leads/wires contains 10 pieces each. Ballast without leads contain 20 pieces each. Installation Notes Switching: Simultaneously disconnect all ungrounded line conductors. Install in accordance with National & Local Electrical Code. Ground ballast case. Dimensions: Model QTP2x54T5HO/UNV PSN-HT enclosure size: Overall: 16.73"L x 1.18"W x 1.0"H (425mm L x 30mm W x 25.4mm H) Mounting: 16.34" (415mm) Height Wiring: Push-in connectors Use 18AWG solid copper wire only Product Weight: 0.88lbs (0.40kg) each (approx.) Length 30.0 mm 1.18” Width Height Dimensions: Model QTP4x54T5HO/UNV PSN-HT-W enclosure size: Overall: 16.73"L x 2.32"W x 1.0"H (425mm L x 59mm W x 25.4mm H) Mounting: 16.34" (415mm) Wiring: Push-in connectors Use 18AWG solid copper wire only Product Weight: 1.68lbs (0.40kg) each (approx.) Item Number Length 59.0 mm 2.32” Width 49161 QTP 4 x 54 T5HO / UNV PSN HTW UL Listed Class P, Type 1, Outdoor, UL Type CC Rated CSA Certified High Ambient Applications: 90°C Max. Case Temp. (3 yr. warranty) Standard Ambient Applications: 70°C Max. Case Temp. (5 yr. warranty) FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62.41 Cat. A Transient Protection Dynamic End-of-Lamp-Life Sensing Remote Mounting (Max. wire length from ballast case to lampholder): up to 18 feet RoHS Compliant 5 5 Complies with European Union Restriction of Hazardous Substances Directive (Directive 2002/95/EC) System Life / Warranty Mounting Length Quantity: 10 (leaded and non-leaded) Starting Method: Programmed Rapid Start Ballast Factor: 1.00 (see table) Circuit Type: Series Lamp Frequency: >42 kHz Lamp CCF: Less than 1.6 Starting Temp: -20°F (-29°C) min.4 Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V rated line (108-305V) 4 Operation below 50°F (10°C) may affect light output or lamp operation – see “Low Temp. Starting” definition. Remote red and brown leads up to 18 feet. Keep blue and yellow (for 4-lamp model only) leads <10 ft Mounting Length Quantity: 49136: 20 (no leads) 49135: 10 (with leads) Specifications 4 High Ambient Temperature (Case) QUICKTRONIC PROFESSIONAL Starting/Ballast Factor Number of Lamps Line Voltage (120-277V) Primary Lamp Wattage SYLVANIA, the system solution, PENTRON, DULUX, QUICKSENSE, SUPERSAVER, PROStart, and QUICK 60+ are registered trademarks of OSRAM SYLVANIA Inc. SEE THE WORLD IN A NEW LIGHT is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH. Q T P T 5H O PSN HT 49136 (49135)* QUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com Specifications subject to change without notice. ©2013 OSRAM SYLVANIA Item Number Description Data based upon SYLVANIA PENTRON® HO lamps shown. QUICKTRONIC® PHO HT ballasts are also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications.
© Copyright 2024 ExpyDoc