KLP Diaphragm Pump Product manual A/1 Version KAMOER fluid tech (shanghai) Co.,Ltd. KLP01 KLP01 Diaphragm Pump KLP Micro diaphragm liquid pump from Kamoer are based on a simple principal of the oscillating displacement pump which is remarkably simpale in design. The circular power from the motor is converted into vertical movement by an eccentric. This motion is then transferred to a diaphragm by means of a connecting rod which in conjunction with an inlet and outlet valve creates a pumping action. KLP 01 type liquid pumps can be mounted in any position and can deliver up to 0.5~0.7 l/min depending on the model and will operate against pressure to 5 bar. Features Small and powerful Self-priming and excellent for pressure Extreme chemical resistance Dry running, durable and maintenance free Brush and Brushless direct current motor for selection KLP01- E 1 KA 1 2 3 4 KLP01 1 Materials of diaphragm KLP01 - E KA 1S Currently we provide two materials of diaphragm for selection: Code Material Performance E EPDM Good resistance and tolerance with alcohol,acid,alkali,oxidant,ketone and fat,etc. Poor oil resistivity. T PTFE Non-Stick、Excellent corrosion resistance.Lifetime is lower than EPDM. Performance Positive pessure(bar) Negative pressure( bar) Liquid pressure(bar) Diaphragm Flow rate (ml/min) E >500 0.6 0.5 3 T >500 0.6 0.5 5 KLP01 - E KA 1S 2 Motor selection Currently we provide eight kinds of motor for selection: KA:24VDC brush motor(56mm) KB:24VDC brushless motor(67mm) KC:12VDC brush motor(56mm) KD:12VDC brushless motor(67mm) KE: 6VDC brush motor(56mm) KG:24VDC brush motor(82.5mm) KH:12VDC brush motor(82.5mm) KI: 6VDC brush motor(82.5mm) Note:Single head for KA、KC、KE Motor,Dual head for KG-KI Motor, Single or Dual head for KB、KD Motor. ml/min Flow rate chart 600 500 400 EPDM 300 PTFE 200 100 0 0 0.5 1 1.5 2 2.5 3 3.5 4 bar KLP01 KLP01 - E KA 1 S 3 Pump head selection Currently we provide 1 or 2 pump heads for selection, see photo: Pump head-1 Pump head -2 ® Note: When select two pump heads, you can use it for two-way output, or for one-way output. If use it as two-way output, it equivalents to two diaphragm pumps run at the same time; If use it as one-way output, the flow rate would increase.* *Total increased amount of flow rate is closely related with tubing connector when pipe merged ,tubing ID. In order to reduce flow rate loss, recommend use Kamoer three-way tubing connector. 4 C ustom parts material selection KLP01 - E KA 1 S Now KLP01 diaphragm pump has one kind of custom part, see photo: eccentric 1. Default material :(PA66),no c ode. Example : KLP01-EKA1 2.Custom material is stainless steel(SUS304,Code is S Example: KLP01-EKA1S Other technical parameter Weight(g) M otor code Volt(V) KA 24 1 0.10 0.30 200 KB 24 1 0.13 0.26 245 KB 24 2 0.20 0.37 275 KC 12 1 0.19 0.36 200 KD 12 1 0.19 0.38 245 KD 12 2 0.25 0.49 275 KE 6 1 0.34 0.78 200 KG 24 2 0.23 0.38 322 KH 12 2 0.42 0.69 322 KI 6 2 0.87 1.90 322 Pump head no-load current(A) Rated current(A) Note: 1.No-load current is the current with no fluid pumping. 2.Rated current is similar to input and output current value when pumping liquid(water) under the atmosphere.In the process of actual use, with the increase of liquid viscosity and input and output pressure, the operating current could corresponding increase. Operating condition: Ambient temperature 0~40℃ Relative humidity (RH)<80% KLP01 Dimensions(mm) Currently we provide two kinds of installation: 1. Side installation method 2. Bottom installation Note:If pump head is 2,only side installation method input 4- 2.5 7 User mounting hole B B 7.8 7 Motor length(See 2 motor selection) 2.6 20.4 27.4 Pump head - 2 Motor length (See 2 motor selection) 27.2 Bottom installation method 7.8 2- 3.2 User mounting hole Side installation method 43.5 3.2 Side installation method User mounting hole 27.2 2- 3.2 31 28(KB、KD) Pump head - 1 60 29.2 A 32.5 A 4.6 Output 81.3 Note: When select bottom installation method, recommend use tapping screw 3 KLP02 KLP02 Diaphragm Pump KLP Micro diaphragm liquid pump from Kamoer are based on a simple principal of the oscillating displacement pump which is remarkably simpale in design. The circular power from the motor is converted into vertical movement by an eccentric. This motion is then transferred to a diaphragm by means of a connecting rod which in conjunction with an inlet and outlet valve creates a pumping action. KLP 01 type liquid pumps can be mounted in any position and can deliver up to 0.8~1.5 l/min depending on the model and will operate against pressure to 5 bar. Features Small and powerful Self-priming and excellent for pressure Extreme chemical resistance Dry running, durable and maintenance free Brush and Brushless direct current motor for selection KLP02- E 1 KA 1 2 3 S 4 KLP02 KLP02 - E KA 1S 1 Materials of diaphragm Currently we provide two materials of diaphragm for selection: Code Material Performance E EPDM Good resistance and tolerance with alcohol,acid,alkali,oxidant,ketone and fat,etc. Poor oil resistivity. T PTFE Non-Stick、Excellent corrosion resistance.Lifetime is lower than EPDM. Performance Positive pessure(bar) Negative pressure(bar) Liquid pressure(bar) Diaphragm Flow rate (ml/min) T >500 0.6 0.4 5 E >850 0.6 0.4 3 KLP02 - E KA 1S 2 Motor selection Currently we provide eight kinds of motor for selection: KA:24VDC brush motor(56mm) KB:24VDC brushless motor(67mm) KC:12VDC brush motor(56mm) KD:12VDC brushless motor(67mm) KE: 6VDC brush motor(56mm) KG:24VDC brush motor(82.5mm) KH:12VDC brush motor(82.5mm) KI: 6VDC brush motor(82.5mm) Note:Single head for KA、KC、KE Motor,Dual head for KG-KI Motor, Single or Dual head for KB、KD Motor. m l/min Flow rate chart 800 700 600 500 EPDM 400 PTFE 300 200 100 0 0 1 2 3 4 5 bar KLP02 KLP02 - E KA 1 S 3 Pump head selection Currently we provide 1 or 2 pump heads for selection, see photo:: Pump head-1 Pump head-2 Note: When select two pump heads, you can use it for two-way output, or for one-way output. If use it as two-way output, it equivalents to two diaphragm pumps run at the same time; If use it as one-way output, the flow rate would increase.* *Total increased amount of flow rate is closely related with tubing connector when pipe merged ,tubing ID. ® flow rate loss, recommend use Kamoer three-way tubing connector.。 In order to reduce 4 Custom parts material selection KLP02 - E KA 1 S Now KLP02 diaphragm pump has one kind of custom part, see photo: eccentric 1. Default material :(PA66),no c ode. Example : KLP02-EKA1 2.Custom material is stainless steel(SUS304,Code is S Example: KLP02-EKA1S Other technical parameter M otor code Volt(V) Pump head no-load current(A) Rated current(A) Weight(g) KA 24 1 0.10 0.30 212 KB 24 1 0.13 0.26 250 KB 24 2 0.20 0.37 290 KC 12 1 0.19 0.36 212 KD 12 1 0.19 0.38 250 KD 12 2 0.25 0.49 290 KE 6 1 0.34 0.78 212 KG 24 2 0.23 0.38 336 KH 12 2 0.42 0.69 336 KI 6 2 0.87 1.90 336 Note: 1.No-load current is the current with no fluid pumping. 2.Rated current is similar to input and output current value when pumping liquid(water) under the atmosphere.In the process of actual use, with the increase of liquid viscosity and input and output pressure, the operating current could corresponding increase. Operating condition: Ambient temperature 0~40℃ Relative humidity (RH)<80% KLP02 Dimensions(mm) Currently we provide two kinds of installation: 1. Side installation method 2. Bottom installation Note:If pump head is 2,only side installation method 32.5 A User mounting hole 7.8 7 27.2 Motor length(See 2 motor selection) B 2.6 user mounting hole Bottom installation method 20.4 43.6 Pump head - 2 3.2 Side installation method 4- 2.5 7 27.2 29.2 2- 3.2 31 28(KB、KD) Input 64 Pump head - 1 A 4.8 Output 7.8 2- 3.2 User mounting hole Side installation method 90 Note: When select bottom installation method, recommend use tapping screw 3 Your fluid Expert KAMOER fluid tech (shanghai) Co.,Ltd. TEL:86-21-67742578 ext 8013 FAX:86-21-67741776 www.kamoer.com ADD:Building 7#No 7459,Beisong Road, SongjiangDistrict,Shanghai,China Mobile:86-13564819209 E-mail: [email protected] 本公司保留对产品外观及技术规格加以改进和改变的权利,恕不另行通知
© Copyright 2024 ExpyDoc