COOLmax_Dross and Saltslag cooler

- engineering your visions -
www.kmf.at
1
- engineering your visions -
Don´t BURN it
-
Present cooling WITHOUT COOLmax
Dust, fumes, waste of energy and
storage problems
COOL it !
COOLmax stopps Aluminium
burning fast and sustainable
No dust, low fumes, safe and quick
processing and no further burning of dross
www.kmf.at
2
- engineering your visions -
Main Components
Vertical airflow
Fan
Hydraulic charging
mechanism
Double walled
cooling container
Slag/Dross container
Motor and control unit
for cooling movement
Solid base
frame
www.kmf.at
3
- engineering your visions -
Approved by Remelters, Refiners and Cast Houses
Direct dedrossing in
COOLmax dross container
Quick and
easy charging
Easy Discharging
Automatic and safe cooling
www.kmf.at
4
- engineering your visions -
temperature [°C]
COOLmax Cooling Performance
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
COOLmax 1500
COOLmax 500
Normal Air Cooling
0
50
100
150
200
250
cooling time [min]
300
350
400
Cooling curves and yield may vary depending on dross or slag conditions
www.kmf.at
5
- engineering your visions -
Results after cooling in COOLmax
www.kmf.at
6
- engineering your visions -
COOLmax Recovery Rates
(from TRF)
Reovery Rate
Dross 55%-60%
Recovery Rate
Dross 70%-75%
54%
68%
Yield air cooling
COOLmax
32%
COOLmax
57%
Yield COOLmax
Yield air cooling
Yield COOLmax
Suitable for dross from cast alloys and wrought alloys containing between app. 40%-75% aluminium
Recovery rates are dependant on time to charge, alloy composition, aluminium content of dross and remelting conditions
www.kmf.at
7
- engineering your visions -
COOLmax Results with TRF Salt Slag
COOLmax Cooling Curve of TRF salt slag with SF 0,4
1400
tempertaure [°C]
1200
1000
800
salt slag 520kg (SF
0,4), Al yield 4 %
600
400
200
0
0
20
40
60
cooling time [min]
80
www.kmf.at
8
- engineering your visions -
Technical Specification
Description
COOLmax 500
COOLmax 1500
Capacity
max 0,5 t
max 1,5 t
Weight of cooling container
app. 1 t
app. 3 t
Dimensions Dross/slag container (LxWxH)
1660 x 1080 x 705
2660 x 1600 x 705
Air flow (vertical exhaust direction)
max. 13m³/sec
max. 800 m³/min
Electrical power
18 kW (400V, 50A)
30 kW (400V, 60A)
Manual safty door when doors are open with 180˚
5,6 x 5,0 x 2,3 m
Ca 5,6 x 5,0 x 2,5 m
E- vertical lift gate with open door
4,0 x 3,4 x 4,0 m
Ca 4,0 x 3,4 x 4,0 m
Total weight with manual safty door
appr. 7.5 t
ca. 21,5 t
Total weight with E-vertical lift gate
appr. 7.8 t
ca. 22,0 t
Dimensions including fence (LxWxH)
www.kmf.at
9
- engineering your visions -
COOLmax Main Advantages
• Minimized Cooling Time
• Maximized Aluminium Recovery
• No filter needed
• No water cooling
• Fast Amortization
• Easy Handling
• CE-certified
www.kmf.at
10
- engineering your visions -
Other Aluminium-related Products of KMF
 Tilting Rotary Furnaces for Aluminiumrecycling
 Design and Construction of Recycling Lines
 Turnkey Remelting Plants
www.kmf.at
11
- engineering your visions -
KMF Facts and Figures
 Established 1874
 5th generation family run company
 Legal status: GmbH (Ltd.)
 Markets: 90% international, 10% national
 85 employees
 Production area 12.000m2
 Storage area 27.000m2
 60 t crane and lifting capacity
 ISO 9001 and ISO 14001 certified
www.kmf.at
12
- engineering your visions -
Contact
Italiener Strasse 62
9500 Villach, Austria / Europe
www.kmf.at
Dr. Erhard Ogris
Head of Sales
phone:
[+43] (0) 699 1200 3307
[email protected]
Peter Kalkusch
Senior Sales Manager
phone:
[+43] (0) 699 1200 3322
[email protected]
Thomas Putz
Sales Manager
phone:
[+43] (0) 699 1234 8621
[email protected]
www.kmf.at
13