BEAVERTON HIGH SCHOOL HEALTH CLINIC 13000 SW 2ND STREET, BEAVERTON, OREGON 97005 NORTH GENERAL NOTES BEAVERTON HIGH SCHOOL HEALTH CLINIC OSSC: BUILDING INFORMATION: PROJECT ADDRESS: 13000 SW 2ND STREET, BEAVERTON, OREGON 97005 PROJECT DESCRIPTION: SW FARMINGTON ROAD SITE STAGING AREA BUILDING OCCUPANT LOAD: 30 OCCUPANTS COMMERCIAL TENANT IMPROVEMENT TO CREATE A SCHOOL BASED HEALTH CLINIC IN EXISTING CLASSROOM SPACE. -REMOVAL OF NON-LOADBEARING INTERIOR CMU WALLS TO COMBINE (2) CLASSROOMS -NEW INTERIOR PARTITIONS AND CEILINGS -NEW FINISHES -NEW HVAC INCLUDING ROOF TOP SCREENING -NEW ELECTRICAL -NEW PLUMBING -NEW EXTERIOR DOORS IN EXISTING LOCATIONS -NEW WINDOWS IN EXISTING DOOR LOCATIONS -MINOR EXTERIOR FINISH CODE REQUIRED LIGHTING AND SIGNAGE @ DOORS BUILDING EXITS REQUIRED: 2 EXIT SEPARATION REQUIRED: 1/2 MAX. DIAGONAL = 42', EXIT SEPARATION IS 64' CONCRETE SLAB ON GRADE WITH PERIMETER FOOTING, EXTERIOR AND INTERIOR CMU WALLS (LOAD BEARING AND NON-LOADBEARING), ROOF TRUSSES BELOW LOW SLOPE ASPHALTIC ROOF. SEC 602 CONSTRUCTION TYPE III-B TABLE 601 FIRE RESISTANCE RATING FOR EXISTING BUILDING ELEMENTS: 1 THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTORS. 2 DIMENSIONS TAKE PRECEDENCE OVER DRAWING: DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATIONS. THE ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCY PRIOR TO CONTINUING WITH WORK. 3 ALL DIMENSIONS ON PLANS ARE FROM FACE OF STUD OR CENTERLINE OF STRUCTURE UNLESS NOTED OTHERWISE. CH 3 USE AND OCCUPANCY CLASSIFICATION: SEC 304: BUILDING OCCUPANCY E TI OCCUPANCY B 4 CH 5 GENERAL BUILDING HEIGHTS AND AREAS: TABLE 508.3: MEETS THE REQUIREMENTS OF A NON-SEPARATED (MIXED) OCCUPANCY E OCCUPANCY IS MORE RESTRICTIVE THAN B 5 CH 6 TYPES OF CONSTRUCTION: SW 2ND EXISTING BUILDING: MAIN BLDG ZONING: R-10 RESIDENTIAL -SCHOOL IS A CONDITIONAL USE CLINIC WILL BE AN ACCESSORY USE TO SCHOOL BUILDING AREA: PROJECT AREA: 18,473 SF 2,972 SF APPLICABLE CODES: 2010 OREGON STRUCTURAL SPECIALTY CODE 2010 OREGON MECHANICAL SPECIALTY CODE 2011 OREGON ELECTRICAL SPECIALTY CODE 2011 OREGON PLUMBING SPECIALTY CODE 2010 OREGON FIRE CODE NATIONAL FIRE PROTECTION (NFPA) ADA-AADAG/ICC 117.2003 STRUCTURAL FRAME: BEARING WALLS: -EXTERIOR: -INTERIOR: NON-BEARING WALLS: -EXTERIOR: -INTERIOR: FLOOR CONSTRUCTION: ROOF CONSTRUCTION: SEC 709.1 (1,2,3,5) (4) 0 HOURS 0 HOURS 0 HOURS NOT REQ. PER EXCEPTION b 6 ALL REQUIRED CITY AND/OR COUNTY LICENSE SHALL BE ACQUIRED AND PAID FOR BY THE INDIVIDUAL TRADE. 7 THE ARCHITECT WILL REVIEW SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT. THE ARCHITECT'S REVIEW OF A SEPARATE ITEM SHALL NOT INDICATE APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM FUNCTIONS. N/A CORRIDOR WALLS AS REQUIRED BY SECTION 1018.1 8 IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WHETHER SHOWN HEREIN OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. 9 CITY APPROVED PLANS SHALL BE KEPT IN A SECURE PLACE AND SHALL NOT BE USED BY WORKMEN. THE CONTRACTOR SHALL BE RESPONSIBLE THAT ALL SUBCONTRACTORS' CONSTRUCTION SETS REFLECT SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN, IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDUMS, AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES. THESE ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. INTERIOR ENVIRONMENT: MIN. FLAME SPREAD RATING EXIT ENCLOSURES: CORRIDORS: ROOMS: EMERGENCY EGRESS PATH (MINIMUM 1 FT CANDLE) EXIT 2 HOURS 0 HOURS B & E OCCUPANCIES A B C CH10 MEANS OF EGRESS: REQUIRED EXIT DENOTES HYPOTHETICAL TRAVEL DISTANCE PATH SIDEWALK ALONG BASEBALL FIELD TABLE 1004.1.1 MAXIMUM FLOOR AREA PER OCCUPANT 100 GROSS (30 OCCUPANTS) SEC 1005.1 EGRESS WIDTH; 0.2 FOR EXIT WIDTH 6" (36" MIN.) SEC 1014.3: COMMON PATH OF EGRESS 200' MAX. SEC 1015.1: MAXIMUM LOAD PER ROOM W/ ONE EXIT PER TABLE 1015.1. 49 OCC. EXIT 15 OCC @ MAX. TRAVEL DISTANCE 65' TABLE 1016.1: TEL: FAX: ATTN: B OCCUPANCY 503.591.4492 503.591.4475 SHERI STANLEY CG THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE THE JOB IS IN PROGRESS AND UNTIL JOB COMPLETION. 11 ALL DEBRIS SHALL BE REMOVED FROM THE PREMISES AND ALL AREAS SHALL BE LEFT IN A BROOM CLEAN CONDITION AT ALL TIMES. 200' MAX. SEC 1018: REQUIRED CORRIDOR RATING: SEC 1018.4: DEAD END CORRIDOR 12 THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES. 13 THE CONTRACTOR IS SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS AND METHODS AND SHALL MAINTAIN THE STRUCTURAL INTEGRITY OF ANY CONSTRUCTION UNTIL ALL FINAL LATERAL AND VERTICAL LOAD CARRYING SYSTEMS ARE COMPLETED. N/A 30 OCC CG CG B OCCUPANCY 20' MAX. (13' PER PLAN) MINIMUM EXITS PER STORY 2 CG CG CG SEC 1021.1: CG CG ARCHITECT SCOTT | EDWARDS ARCHITECTURE, LLP 2525 E. BURNSIDE STREET PORTLAND, OREGON 97214 10 MAXIMUM EXIT ACCESS TRAVEL PROJECT DIRECTORY OWNER: BEAVERTON HIGH SCHOOL 13000 SW 2ND STREET BEAVERTON, OREGON 97005 THE CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS HE MAY DISCOVER. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ERROR AFTER THE START OF CONSTRUCTION WHICH HAS NOT BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT. THE MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY THE ARCHITECT. CH 7 FIRE AND SMOKE PROTECTION FEATURES: TABLE 803.9 LEGEND: 0 HOURS ALL CONSTRUCTION SHALL COMPLY WITH THE 2010 OREGON STRUCTURAL SPECIALTY CODE AND ALL LOCAL GOVERNING BUILDING CODES AND ORDINANCES. CG CG TEL: FAX: ATTN: CG CG 503.226.3617 503.226.3715 SARAH CANTINE 14 CH 13 ENERGY EFFICIENCY: CG TBL N1101.2 CG STRUCTURAL: BUTLER CONSULTING INC. 16110 SE GOOSEHOLLOW DR. DAMASCUS, OR 97089 TEL: FAX: ATTN: 503.658.0200 CG CG MARK BUTLER CG MEP MKE & ASSOCIATES 6915 SW MACADAM AVE, SUITE 200 PORTLAND, OR 97219 CG 503.892.1188 RICK DUSA JEFF REILLY 15 OCC @ MAX. TRAVEL DISTANCE 60' - WORK BY OWNER GRAPHIC SYMBOLS 16 CONTRACTOR TO PROVIDE BACKING OR BLOCKING AS REQUIRED FOR MOUNTING ALL WALL MOUNTED SHELVES, EQUIPMENT, ACCESSORIES, CABINETS, ETC. 17 CAULK SHALL BE USED TO SEAL ALL JOINTS OF MILLWORK, TRIM, EQUIPMENT MOUNTING, WALL PENETRATIONS AND FLASHINGS TO PRODUCE A WATERTIGHT SEAL. 18 THE SITE AND BUILDINGS ARE DESIGNED TO COMPLY WITH ADA-ABAG CODES. 19 CONTRACTOR SHALL PROVIDE MANUFACTURER'S PRODUCT LITERATURE, SHOP DRAWINGS, INSTALLATION INSTRUCTIONS, AND/OR SAMPLES AS REQUIRED FOR OWNER'S/ARCHITECT'S REVIEW PRIOR TO INSTALLATION. 20 CONTRACTOR SHALL SALVAGE ALL EXISTING BUILDING COMPONENTSFOR CLIENT OR PROJECT REUSE. SEE NOTES. 3404 ALTERATIONS EXIT TEL: FAX: ATTN: ALL ELECTRICAL, MECHANICAL AND PLUMBING WORK SHALL CONFORM TO THE REQUIREMENTS OF THE CURRENT NEC, UMC, UPC RESPECTIVELY. ISSUED FOR REFERENCE ONLY REVISION REVISION (ISSUED VIA 8-1/2 x 11) GENERAL A0.1 COVER SHEET A1.1 DEMO FLOOR PLAN A2.1 FLOOR PLAN A2.2 REFLECTED CEILING PLAN A2.3 EQUIPMENT & MATERIALS PLAN A4.1 BUILDING SECTIONS A6.1 INTERIOR ELEVATIONS A6.2 INTERIOR ELEVATIONS A6.3 INTERIOR ELEVATIONS A8.1 DETAILS A8.2 CASEWORK DETAILS SCHEDULES: DOOR, WINDOW, ROOM A9.1 A9.2 CONSTRUCTION ASSEMBLIES E0.1 ED2.1 E1.1 E1.2 E2.1 E3.1 ELECTRICAL TITLE SHEET ELECTRICAL DEMOLITION PLAN OVERALL ELECTRICAL PLAN ELECTRICAL SCHEDULES POWER & SIGNAL PLAN LIGHTING PLAN Digitally signed by Lisa McClellan Date: 2014.05.05 11:35:53-07'00' BEAVERTON SCHOOL DIST. SBHC FACILITY 13000 SW 2ND STREET BEAVERTON, OR 97005 MT.01 MECHANICAL TITLE SHEET P1.0 PD2.1 P2.1 P9.0 PLUMBING SCHEDULES PLUMBING DEMOLITION PLAN PLUMBING PLAN PLUMBING DETAILS M1.0 MD2.1 M2.1 M9.0 HVAC SCHEDULES HVAC DEMOLITION PLAN HVAC PLAN HVAC DETAILS CH 34 EXISTING STRUCTURES: SIDEWALK ALONG PARKING LOT CONTRACTOR: TBD - 15 ISSUED FOR OWNER REVIEW / PRICING CG CG TEL: FAX: ATTN: BUILDING COMPONENT REQUIREMENTS WALLS = NOT ALTERED FLAT CEILING = NOT ALTERED WINDOWS = U-0.46 EXTERIOR GLAZED DOORS = U-0.80 THE CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REPLACE OR REMEDY ANY FAULTY, IMPROPER OR INFERIOR MATERIALS OR WORKMANSHIP WHICH SHALL APPEAR, WITHIN ONE (1) YEAR AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK UNDER THIS CONTRACT, U.N.O. IN THIS CONTRACT. ISSUED FOR CONSTRUCTION / PERMIT ISSUE 5/2/14 ISSUE 4/17/14 PROJECT SUMMARY: VICINITY MAP NTS SEC 3401.1 GENERAL: EXCEPT AS REQUIRED BY 3401.4 OR THIS SECTION, ALTERATIONS TO ANY BUILDING OR STRUCTURE SHALL COMPLY WITH THE REQUIREMENTS OF THE CODE FOR NEW CONSTRUCTION. ALTERATIONS SHALL BE SUCH THAT THE EXISTING BUILDING OR STRUCTURE IS NO LESS COMPLYING WITH THE PROVISIONS OF THIS CODE THAN THE EXISTING BUILDING OR STRUCTURE WAS PRIOR TO THE ALTERATION. BID ALTERNATES 1. MEDICAL, DENTAL & OFFICE FURNITURE & EQUIPMENT AS SPECIFIED. 2. WIRING HOOKUP AND PROGRAMING FROM THERMOSTATS TO MECHANICAL UNITS. 1. ADD ALTERNATE # 1: SUBSTITUTE RESILIENT FLOORING IN LIEU OF EXISTING EXPOSED CONCRETE FLOORING. SEE FINISH SCHEDULE FOR FLOORING TYPE. . ABBREVIATIONS Drawing: ROOM # ROOM NAME TAG - DOOR TAG - SEE DOOR SCHEDULE ELEVATION MARKER WINDOW TAG - SEE WINDOW SCHEDULE W - GRIDLINE BUBBLE KEYNOTE DTL # SHT # E INTERIOR ELEVATION MARKER S - FIXTURE/EQUIPMENT TAG SEE EQPT SCHEDULE - BUILDING ASSEMBLY TAG SEE BUILDING ASSEMBLY SCHEDULE DTL # SHT # DTL # - FINISH TAG SEE SHEET FINISH SCHEDULE # REVISION NUMBER SHT # DTL# SHT # BUILDING SECTION MARKER EXTERIOR ELEVATION MARKER DETAIL MARKER L @ C L # Ø Angle At Centerline Pound or Number Diameter or Round AB AC AD ACOUS ACT ADJ AL APPROX ARCH ASPH Anchor Bolt Asphaltic Concrete Area Drain Acoustical Acoustic Ceiling Tile Adjustable Aluminum Approximate or Approximately Architectual or Architect Asphalt BD. BITUM. BLDG. BLK. BLKG. BM. BOT. Board Bituminous Building Block Blocking Beam Bottom C.B. C.I. C.J. C.L. CAB. CEM. CER. CL. CLG. CLKG. CLOS. CLR. CNTR. COL. CONC. CONN. CONSTR. CONT. CTR. CTSK. Catch Basin Cast Iron Ceiling Joist Centerline Cabinet Cement Ceramic Centerline Ceiling Caulking Closet Clear Counter Column Concrete Connection Construction Continuous Center Countersunk DIA. DIM. DN. DR. D.W. DWG. DWR. Diameter Dimension Down Door Dishwasher Drawing Drawer E. E.J. EA. ELEC. ELEV. EMER. ENCL. EQ. EQUIP. EXIST./(E) EXP. EXT. East Expansion Joint Each Electrical Elevation Emergency Enclosure Equal Equipment Existing Exposed Exterior D.F. D.O. D.S. D.S.P. DBL. DEPT. DET./DTL. Douglas Fir Door Opening Downspout Dry Standpipe Double Department Detail F.A. F.D. F.E. F.F. F.O.F F.G. F.O.C. F.O.S. FDN. Fire Alarm Floor Drain Fire Extinguisher Finish Face Face of Finish Fibreglass Face of Concrete Face of Stud Foundation FIN. FLASH. FLR. FLUOR. FPRF. FRZ. FT. FTG. FURR. FUT. Finish Flashing Floor Fluorescent Fireproof Freezer Foot or Feet Footing Furring Future I.D. IN. INSUL. INT. Inside Diameter Inches Insulation Interior JAN. JST. JT. Janitor Joist Joint KIT. Kitchen G.B. G.C. GA. GALV. GL. GND. GR. GYP. Grab Bar General Contractor Gauge Galvanized Glass or Glazing Ground Grade Gypsum L. or LIN. L.B. LAB. LAM. LAV. LKR. LT. LTWT. Linen Closet Leader Box Laboratory Laminated Lavatory Locker Light Lightweight H.B. H.C. H.M. H. WD. HDWR. HNDCP. HORIZ. HR. HT. Hose Bibb Hollow Core Hollow Metal Hardwood Hardware Handicap Horizontal Hour Height M.C. M.O. MAT. MAX. MECH. MFR. MH. MIN. Medicine Cabinet Masonry Opening Material Maximum Mechanical Manufacturer Manhole Minimum MIR. MISC. MTD. MTL. MUL. Mirror Miscellaneous Mounted Metal Mullion (N) N. N.I.C. N.T.S. NOM. New North Not In Contract Not To Scale Nominal O. O.C. O.D. OBS. O.F.C.I. OPNG. OPP. Oven On Center Outside Diameter (Dim.) Obscure Owner Furnished Contractor Installed Opening Opposite P. P.LAM. P.W. PL. PLAS. PLYWD. or P.W. PRCST. PT. Pantry Plastic Laminate Plywood Plate Plaster Plywood Pre-cast Point Q.T. Quarry Tile R. R.D. R.O. R.R. RAD. or R. REC. REF. REFR. REINF. REQ'D. RESIL. REV. RGTR. RM. RWD. or R.W. Riser Roof Drain Rough Opening Roof Rafter Radius Recommendation Reference Refrigerator Reinforcement Required Resilient Revision Register Room Redwood S. S.C. S.D. S.S. S.SK. SCHED. SEC. SHF. or SH. SHT. SHWR. South Solid Core Soap Dispenser Stainless Steel Service Sink Schedule Section Shelf or Shelves Sheet Shower SIM. SPEC. SQ. STA. STD. STL. STOR. STRL. STRUCT. SUSP. SYM. Similar Specification Square Station Standard Steel Storage Structural Structural Suspended Symmetrical U.N.O. UNF. UR. Unless Noted Otherwise Unfinished Urinal V.A.T. V.G. VCT. VER. VERT. VEST. VIF Vinyl Asbestos Tile Vertical Grain Vinyl Composite Tile Verify W. Arch/Owner Vertical Vestibule Verify in field T.&G. T. T.B. T.C. T.O. T.P. T.P.D. or T.P.H. Tongue and Groove Tread Towel Bar Top of Curb Top of Overhang Top of Pavement Top of Toilet Paper Dispenser or Holder Television Top of wall Telephone Terrazzo Thick Thickness Typical W. W.C. W.I. W.P. W/ or W. W/O WD. WSCT. WT. West Water Closet Wrought Iron Waterproof With Without Wood Wainscot Weight T.V. T.W. TEL. TER. THK. THK. TYP. COVER SHEET Job No: 13108 Date: 5-2-14 Sheet No: A0.1 1 2 2 A4.1 3 3 A4.1 7 8 A 10 4 4 3 4 Digitally signed by Lisa McClellan Date: 2014.05.05 11:36:02-07'00' 4 B 6 6 C 3 1 EXISTING CLASSROOM A4.1 EXISTING CLASSROOM BEAVERTON SCHOOL DIST. SBHC FACILITY 13000 SW 2ND STREET BEAVERTON, OR 97005 5 1 5 4 1 2 2 A4.1 3 3 A4.1 A B C 1 A4.1 D D S406 C406 E EXISTING RESTROOM 1'-6" 2 2 NOTE: REFER TO M-E-P DRAWINGS FOR BALANCE & EXTENT OF DEMOLITION, AND COORDINATE FOR THE LEAST AMOUNT OF FLOOR SAWCUTTING/DEMO. 10 9 9 4'-0" AREA OF WORK 4 E 1 OVERALL BUILDING PLAN 1 NTS GENERAL NOTES: DEMO FLOOR PLAN 8 1/4" = 1'-0" SYMBOL LEGEND: SYMBOL 7 DESCRIPTION Drawing: KEYNOTES: SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION 1.) ALL DIMENSIONS ARE TAKEN FROM F.O. STUD/CMU U.N.O. 2.) ALL GRIDLINES SHOWN ARE F.O. CMU/STUD U.N.O. ROOM # 3.) PROTECT EXISTING CONC FLOOR DURING DEMO. EXISTING CONC FLOOR IS TO BE THE EXPOSED FINISHED FLOOR. 5.) PROTECT EXISTING CONSTRUCTION AND ACTIVE SYSTEMS TO REMAIN DURING CONSTRUCTION. I.E. (BUT NOT LIMITED TO): SPEAKER/INTERCOM, SECURITY, DATA, AND FIRE ALARM. DOOR TAG, SEE DOOR SCHEDULE ON SHEET A7.1 ### X 4.) LIMITS OF DEMOLITION ARE GENERAL. CONTRACTOR TO VERIFY EXACT DEMOLITION REQUIRED TO PREPARE SUBSTRATES FOR NEW FINISH. # WINDOW TAG, SEE SCHEDULE ON SHEET A7.1 XX-X 1 EXISTING CONSTRUCTION TO BE REMOVED 2 3 4 EXISTING FORCED AIR DUCTWORK TO BE ABANDONED IN PLACE -SEE MD2.1 FOR MORE INFORMATION. 5 REMOVE ANY LOOSE CEILING TILE ABOVE & DISPOSE. 6 REMOVE EXISTING LIGHT FIXTURES & DISPOSE. INTERIOR ELEVATION TAG # SHT # SHT SEE PD2.1 FOR INFORMATION ON REMOVAL OF EXISTING DRINKING FOUNTAINS. NOTE: IF ASBESTOS LADEN WRAP IS FOUND ON PLUMBING ABATE PER CODE. REMOVE AND DISPOSE OF EXISTING CABINETRY AND FIXTURES. RECYCLE WHERE POSSIBLE. C 6.) REFER TO M-E-P DRAWINGS FOR BALANCE & EXTENT OF DEMOLITION. DEMOLISH 6" CMU WALLS TO SLAB, CUT REBAR & GRIND TO EXISTING SLAB HEIGHT. NOTE: EXISTING CONCRETE TO BE FINISHED FLOOR FINISH FINISH TAG - SEE FINISH SCHEDULE ON SHEET A7.1 A # D SHT B KEYNOTE ROOM TAG BLDG OR WALL SECTION FLAG EXTERIOR ELEVATION TAG 7 REMOVE EXISTING FRAMED DOOR FOR NEW FRAME & WINDOW. 8 REMOVE EXISTING FRAMED DOOR FOR NEW DOOR & FRAME. 9 EXISTING ELECTRICAL PANELS TO REMAIN. 10 1 2 EXISTING 1 " & 2" COLD WATER LINES TO REMAIN. SEE PLUMBING DEMO/EXISTING FLOOR PLAN Job No: 13108 Date: 5-2-14 Sheet No: A1.1 1 2 2 A4.1 3 3 A4.1 65'-5" 35'-4 1/2" 30'-0 1/2" EQ. 9'-10 1/2" 5'-5 1/2" 8 1/4" EQ. 9'-9 1/2" 9'-10" 10'-5" 3'-4" VIF 120A 9'-10 1/2" B A 9 2'-0" 5 3'-4" VIF 9 1'-0' MIN DENTAL CARE ROOM CARE ROOM CARE ROOM MH ROOM 11'-2" CARE ROOM 5 A 9 7 117A 1'-6" FIN TYPICAL FOR ALL CARE ROOMS 5'-0" 1'-6" FIN 1'-6" FIN CG A 1 A6.3 6 1'-6" FIN Digitally signed by Lisa McClellan Date: 2014.05.05 11:36:13-07'00' 122A 6 6 121A C B A6.2 A A HALL 6 119A 6 118A 6 D A6.2 B C B 9 CG 4 C A6.2 B 2" CG CG CG 5'-0" 5'-9" 2 A6.1 E CG ELIGIBILITY 18'-4" A D 2 1" C CG RECEPTION D CG 9 1/2" 10° 1 1/2" 3 10 A6.1 3 3 30" MIN. 8 3'-10" VIF WAITING 2'-9" 100A 1'-6" 4 7 CG 9 8" 3'-10" VIF 4'-1 1/2" ENTRY D A6.1 B C CG 1'-6" 1 CG 15'-5" A 1'-3" EXISTING RESTROOM AREA OF WORK CG CG 11 101A EW2 E CM OFFICE 2'-6" 1 CG D 8'-0" 1'-1" 2 CG CG CG 53'-6" 21'-11" 8'-0" 9 CG CG 3'-5" CG 129A A4.1 PRINT CG 3'-1" CG CG CG MP OFFICE 2'-9" CG A6.1 B HALL SUPPORT 4" 4" 3'-0" 6'-4" 1 A6.2 B 4'-2" CG 6'-9 3/4" A 2 A6.2 3 2'-6" BEAVERTON, OR 97005 A A B A6.2 PRINT STORAGE 109A 13000 SW 2ND STREET 8'-9" 104A 7'-6" 128A 4 D A6.3 B C BEAVERTON SCHOOL DIST. SBHC FACILITY 1 CG CG A4.1 A C CG CG 1 3 4'-2" CG CG TEAM A A6.3 ° 90 CG PREP 6'-4" 107A 2'-1" ° 80 RESOURCE B CG CG RR 108A A4.1 CG LAB 110A A CG CG CG 2 D A6.3 B C CG 116A 3 3 A 5 D A6.3 B C 10'-2" 111A 5'-0" 3'-10" MECH C CG CG 12 2 CG W1 8'-2" SERVER CG 2 123A 124A 4'-6" A 7'-6 1/2" 115A JAN GROUP A4.1 5'-4" 2'-2" CG HALL 1 6'-7" RR 2'-11" 6 1/2" 8'-10" 5 B A6.2 5'-9" 2 1/2" CG BREAK A 6'-10" CG 11 4A 113A 5'-5" 4'-4" 4'-4" 3'-5" HALL 5'-1" STOR A 5 A8.2 EW2 CG E 1 OVERALL BUILDING PLAN 1 NTS GENERAL NOTES: 1.) ALL DIMENSIONS ARE TAKEN FROM F.O. STUD/CMU U.N.O. 2.) ALL GRIDLINES SHOWN ARE F.O. CMU/STUD U.N.O. FLOOR PLAN 1/4" = 1'-0" SYMBOL LEGEND: SYMBOL ROOM # DESCRIPTION # ### DOOR TAG, SEE DOOR SCHEDULE ON SHEET A7.1 4.) SEE DOOR SCHEDULE FOR DOOR TYPES AND INSTALLATION DETAILS CORRESPONDING TO DOOR NUMBERS. X WINDOW TAG, SEE SCHEDULE ON SHEET A7.1 XX-X 5.) SEE WINDOW SCHEDULE FOR WINDOW TYPES & DIMENSIONS. 6.) EQUIPMENT AND FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY. 7.) FOR FLOOR FINISHES SEE FINISH SCHEDULE - SHEET A9.1 # 10.) PATCH FLOOR PER SPECIFICATIONS. MATCH LEVEL, FINISH AND COLOR. DESCRIPTION KEYNOTE INTERIOR ELEVATION TAG LINE OF CONSTRUCTION ABOVE FE CG SYMBOL DESCRIPTION DESCRIPTION 1 FIRE ALARM PAD -COORDINATE W/SIMPLEX DESIGNED SYSTEM CFCI. 6 WALL MOUNTED COMPUTER CONTROL ARM OFCI -SEE 11/A8.1. 2 SECURITY PAD COORDINATE WITH SECURITY DESIGNED SYSTEM TIED TO SCHOOL. CFCI. 7 EXISTING 1 21" CW SUPPLY 3 EXISTING ELECTRICAL PANEL TO REMAIN. 8 NEW WALL MOUNTED DRINKING FOUNTAIN. 4 FURR WALL AT EXISTING WATER SUPPLY AND FOR SIDE WALLS WITH REMOVABLE COUNTER FOR ACCESS TO WATER SHUT-OFF. SEE 5/A8.2. 9 FORM & FILL W/ CONCRETE (E) FLOOR REGISTER. GRIND SMOOTH TO MATCH ADJACENT FLOOR FINISH. 10 RAISED SOFFIT WITH COVE LIGHTING ABOVE SHOWN DASHED. 11 NEW MECHANICAL UNITS IN EXISTING MECHANICAL MEZZANINE ABOVE EXISTING RESTROOM 12 PROVIDE BLOCKING IN WALL FOR WALL MOUNTED PROJECTION SCREEN FIRE EXTINGUISHER CABINET - SEE GENERAL NOTE CORNER GUARD, 4' HIGH SYMBOL FLOOR PLANS Job No: 13108 Date: 5-2-14 C 8.) PROVIDE FIRE EXTINGUISHER CABINETS AS SPEC'D. COORDINATE FINAL LOCATIONS WITH FIRE MARSHALL. 9.) SEE DETAIL A9.2 FOR TYPICAL PARTITION CONSTRUCTION - INTERIOR PARTITIONS W-1 U.N.O. - INTERIOR FURRING PARTITION EW-1 U.N.O. FINISH TAG - SEE FINISH SCHEDULE ON SHEET A7.1 A D SHT B SYMBOL ROOM TAG 3.) ALL DOOR / WINDOW DIMENSIONS ARE TO CMU OPENING, SEE WINDOW SCHEDULE AND WINDOW DETAILS FOR TYPICAL INSTALLATION DETAIL. Drawing: KEYNOTES: # SHT # SHT BLDG OR WALL SECTION FLAG EXTERIOR ELEVATION TAG 5 POWER BOX FOR DENTAL CHAIR (SURFACE MOUNT). COORDINATE W/E2.1 FOR POWER AND DENTAL SUPPLY FOR BOX SIZE (OFCI). PROVIDE A 2" BELOW SLAB CONDUIT SLEEVE CUT FLUSH TO SLAB FOR DENTAL SUCTION LINES TO CABINET (OFOI). CONDUIT AND ELECTRICAL TO FIT WITHIN BOX. SEE 8/A8.2. Sheet No: A2.1 1 2 2 A4.1 3 3 A4.1 A CARE ROOM DENTAL CARE ROOM +-9'-0" +-9'-0" +-9'-0" CARE ROOM HALL CARE ROOM +-9'-0" +-9'-0" +-9'-0" MH ROOM FIXTURE LEGEND: SYMBOL Digitally signed by Lisa McClellan Date: 2014.05.05 11:36:23-07'00' +-9'-0" +8'-2" B DESCRIPTION RECESSED FLUORESCENT (GRID) STOR 5 HALL +-12'-0" +-12'-0" +8'-4" TYP RECESSED FLUORESCENT (GRID & GYP) S C TEAM +-12'-0" JAN RECESSED DOWN LIGHT BREAK +-12'-0" +-9'-0" MECH SERVER +8'-2" 1 +-9'-0" RECESSED DOWNLIGHT - WALL WASH +-12'-0" +-9'-0" LAB RR 1 A4.1 +-8'-0" PREP UNDER CABINET LIGHT RR +8'-2" +-8'-0" MP OFFICE HALL CLOSET LIGHT STORAGE SUPPORT +-9'-0" 13000 SW 2ND STREET +-8'-0" BEAVERTON, OR 97005 +-9'-0" HALL GROUP VANITY STRIP LIGHT BEAVERTON SCHOOL DIST. SBHC FACILITY +8'-2" +-9'-0" +10'-0" +8'-2" +-12'-0" PENDANT LIGHT RESOURCE ELIGIBILITY RECEPTION CM OFFICE 14' -6" COVE LIGHT +7'-6" +-8'-0" +8'-2" 5 D EXTERIOR WALL MOUNT LIGHT 11'-0" EXIT LIGHT +12'-0" SPEAKER / P.A. 8'-0" S 9" MEZZANINE ABOVE 9'-0 " MEZZANINE ABOVE 25° MEZZANINE ABOVE EXHAUST FAN WAITING ENTRY 4 +10'-0" S 6 A8.1 RETURN AIR DIFFUSER SUPPLY DIFFUSER E 1 GENERAL NOTES: 1.) ALL DIMENSIONS ARE TAKEN FROM F.O. STUD OR COL â„„ U.N.O. 2.) ALL GRIDLINES SHOWN ARE F.O. STUD U.N.O. 3.) ALL CEILINGS PT-2 U.N.O. 4.) ALL CEILINGS 9'-0" U.N.O. 5.) LOCATE ALL LIGHT FIXTURES, MECHANICAL DIFFUSERS, SPRINKLER HEADS, ACCESS PANELS, SPEAKERS & ANY OTHER CEILING-MOUNTED DEVICES IN THE CENTER OF THE ROOM, SPACE OR CEILING GRID UNLESS DIMENSIONED OR NOTED OTHERWISE. 6.) PROVIDE ACCESS PANELS AS REQ'D BY ALL TRADES AT INACCESSIBLE CEILINGS. FINISH TO MATCH CEILING. ARCHITECT TO REVIEW BEFORE INSTALLATION. 7.) SUSPENDED CEILING SHALL COMPLY W/ SEC. 808.1 AND ASCE 7-05 SEC. 13.5.6. SEE A9.2 FOR MORE INFO. 8.) SPECIAL INSPECTION IS REQUIRED FOR THE SUSPENDED CEILING AND ITS ANCHORAGE IN SEISMIC DESIGN CATEGORY D, E, 1705.3. 9.) SEE ELECTRICAL SHEETS FOR LIGHTING SPECIFICATION, SUPPLY, RETURN & EXHAUST. REFLECTED CEILING PLAN 1/4" = 1'-0" SYMBOL LEGEND: SYMBOL ROOM # # DESCRIPTION ROOM TAG SYMBOL FINISH TAG - SEE FINISH SCHEDULE ON SHEET A7.1 +9'-0" CEILING ELEVATION TAG EMERGENCY 'EXIT' SIGN. SHADED AREA INDICATES ILLUMINATED FACE. ARROW INDICATES DIRECTION OF TRAVEL. DESCRIPTION 1 COOLING FAN SEE MECH 2 NOT USED 3 NOT USED 4 5 SYMBOL DESCRIPTION REFLECTED CEILING PLAN ACT-1 SUSPENDED ACOUSTIC TILE PANEL CEILING KEYNOTE ACT-1 Drawing: KEYNOTES: Job No: 13108 NEW PULL DOWN LADDER W/IN EXISTING OPENING Date: 5-2-14 NEW SPEAKERS -CONNECT TO EXIST'G P.A. INFRASTRUCTURE W/ VOLUME CONTROL. VERIFY LOCATIONS WITH OWNER Sheet No: SUSPENDED OR DIRECT HUNG GYPSUM CEILING A2.2 1 2 3 A SHARPS SHARPS SOAP WOM-2 XRAY DCHAIR PT SOAP GLOVE CARE ROOM EX LI PT CARE ROOM CARE ROOM PT-3 CARE ROOM MH ROOM 3 DENTAL B A6.2 CO HK A CG PT-1 WASTE A CG CONC CPT-1 PT-1 PT-5 RR A 3 BDRAW PT-1 D A6.2 B C BREAK MECH A 2 B A6.2 CONC A D A6.2 B C IMM UC LAB UC SPEC CG PRINT ULTRA S FAX PT-1 PT-1 PT-1 PT-5 4 BEAVERTON, OR 97005 PT-5 PT-3 HALL A 2 A6.1 B A PT-4 CG B A6.1 PT-3 CONC CPT-1 PRINT STORAGE CG 13000 SW 2ND STREET PT-5 SEE 4/A6.3 FOR A ACCESSORY 2 D A6.2 B LOCATIONS C A A6.3 AUTOCLV CENTRIF PT-1 BEAVERTON SCHOOL DIST. SBHC FACILITY CG CG 1 RR A CONC CPT-1 PREP SEE 2/A6.3 FOR ACCESSORY LOCATIONS EYE WA CPT-1 HALL TEAM SCALE CG PT-1 PT-3 PT-3 CG CG 6 SPEC PT SEE 5/A6.3 FOR ACCESSORY LOCATIONS S RACK GROUP IMM F 3 A6.1 MP OFFICE PT-5 PT-5 SERVER C CG STAD SHARPS WASTE JAN PT-5 CG CG PRO SC B PT-1 CG REF Digitally signed by Lisa McClellan Date: 2014.05.05 11:36:31-07'00' HALL 1 C A6.2 B MICRO 2 A6.3 HALL CHART STORAGE A PT-5 CA PT-4 5 D A6.2 B C PT-4 CA PT-4 PT-4 A PT-4 EQ RA GLOVE SUPPORT CG CG CG CG CPT-1 CONC CONC CPT-1 RECEPTION PT-5 CG CG MATERIALS LEGEND PT-5 CPT-1 PT-6 CG PT-3 WALL PAINT PT-4 WALL PAINT D CM OFFICE CONC PT-3 CG CG PT-5 A PT-5 EXISTING RESTROOM WALL PAINT 1 CPT-1 CG CG PT-3 D A6.1 B C WOM-1 PT-6 WALL PAINT SEE A6.3 FOR ACCESSORY SCHEDULE CONC CONCRETE FLOOR CPT-1 CARPET FLOOR WOM-1 WALK-OFF MAT FLOOR WOM-2 WALK-OFF MAT FLOOR WAITING PT-5 CG E NOTE: COORDINATE WITH INFORMATION ON INTERIOR ELEVATIONS AND A9.1 FLOOR PLAN 1 GENERAL NOTES: ENTRY 1/4" = 1'-0" Drawing: EQUIPMENT/ACCESSORY LEGEND: SYMBOL DESCRIPTION VG BSD * NOTE: EXTRA TALL SEE ELEVS CFCI OFCI OFOI SYMBOL DESCRIPTION SHARPS SHARPS CONTAINER VG BSD CFCI OFCI OFOI SYMBOL DESCRIPTION 1.) ALL FURNISHINGS SHOWN FOR REFERENCE, OFOI. 2.) SEE EQUIP LEGEND FOR INSTALLATION RESPONSIBILITIES 3.) SEE CARE ROOM # 118 FOR TYPICAL LAYOUT. ALL OTHERS SIMILAR. CA EQ RA 4.) TOILET ACCESSORIES BY CONTRACTOR, SEE SCHEDULE ON A6.3. 5.) PROVIDE BLOCKING FOR ALL MOUNTED EQUIPMENT. WALL MOUNTED COMPUTER ARM EQUIPMENT RAIL FOR SPHYGMOMANOMETER & OPTHAMALASCOPE GLOVE SOAP CHART CHART RACK REF BREAK ROOM REFIGERATOR DCHAIR DENTAL CHAIR & POWER BOX UC SPEC UNDER COUNTER SPECIMENT REFIGERATOR SUMMIT, MODEL FF511L * IMM F IMM UC IMMUNIZATION REFRIGERATOR HELMER SCIENTIFIC, HORIZON MODEL HLR111 UNDER COUNTER IMMUNIZTION FREEZER PANASONIC, MODEL SF-L6111W-PA * PT GLOVE DISPENSER XRAY FAX DENTAL XRAY - HAND HELD PRINT PRINTER PAPER TOWEL DISPENSER EX LI EXAM LIGHT - FLOOR EY WA EYE WASH MICRO MICROWAVE CO HK COAT HOOK SCALE WEIGHT SCALE STAD STADIOMETER SPECIMEN PASS THROUGH S RACK SERVER RACK WASTE WASTE RECEPTICAL PRO SC PROJECTION SCREEN (CONTRACTOR PROVIDED WALL BLOCKING) BSD CFCI OFCI OFOI EQUIPMENT & MATERIALS PLAN FAX MACHINE SOAP DISPENSER SPEC PT VG BD DRAW BLOOD DRAW CHAIR CENTRIF CENTRIFUGE AUTOCLV AUTOCLAVE ULTRA S ULTRASOUND Job No: 13108 Date: 5-2-14 Sheet No: A2.3 1'-6" +/- 2'-10 1/4" 3'-0" 2'-10 1/4" KEYNOTES: 3'-0" SYMBOL +12'-2" R1 BREAK MECH R1 SERVER R1 HALL 4 W1 1 INSULATE ALL NEW WALLS, TYP. 2 WALLS TO UNDERSIDE OF CEILING STRUCTURE BENEATH TRUSSES, TYPICAL. 3 DEMOLISH (E) WALL. SEE A1.1. 4 HVAC SEE M2.1 R1 TYP RESTROOM R3 DESCRIPTION LAB R3 R3 R2 R3 TEAM PREP EW1 TYP W2 (FOR POCKET DOOR) EW1 TYP Digitally signed by Lisa McClellan Date: 2014.05.05 11:36:41-07'00' +0'-0" PAINTED METAL FLASHING CAP DASHEDABOVE P.T. END TRIM EXISTING TRUSSES BELOW TYP. 1 NORTH-SOUTH BUILDING SECTION P.T. RAILS 5 1/4" = 1'-0" A4.1 24'-10" 2'-0" 4/5 A4.1 SCREENING SIGHTLINE NOTE: LOCATION OF ROOF TOP UNITS SHOWN FOR PURPOSES OF LOCATION AND TO KEY TO DETAILS ONLY (NOT RELATIVE TO ROOMS BELOW). COORDINATE ONSITE WITH EXISTING TRUSS LAYOUT AND DETAILS TO RIGHT. PROVIDE WATERTIGHT PATCH AND REPAIR AT ALL NEW ROOF PENETRATIONS, CURBS AND BOOTS. SCREENING SIGHTLINE 3'-0" CLR 6'-0" 3'-0" CLR CONNECTIONS? BEAVERTON SCHOOL DIST. SBHC FACILITY +12'-2" 13000 SW 2ND STREET 4 HALL R3 RESTROOM HALL R3 RESTROOM R3 ELIGIBILITY 2'-0" CLR R1 ENTRY R3 BEAVERTON, OR 97005 NEW PAINTED METAL POSTS ATTACHED TO EXISTING TRUSS FACE TYP. W1 TYP 3 4'-0" TYP EW2 +0'-0" 4 ENLARGED MECHANICAL SCREEN PLAN 3/4" = 1'-0" PT 2X CAP UNDER PAINTED METAL CAP FLASHING -MATCH SIDING 2 EAST-WEST BUILDING SECTION THROUGH ENTRY 1/4"x2"x2" STEEL TABS WELDED TO POST TYP 1/4" = 1'-0" PT 2X RAILS AND VERTICAL SIDING NAILERS CORRUGATED SIDING 24 GA NU-WAVE PANELS 3/8"x3" LAG SCREW TYP EA CORNER PREMANUFACTURED PIPE BOOT H8 TIE SLEEPER TO TRUSS TYP SEE DETAIL 4/M9.0 HSS2x2x3/16" TUBE STEEL POST @48" O.C. +12'-2" 4 R1 Drawing: R3 CARE ROOM WAITING BUILDING SECTIONS R3i HALL W1 TYP EW1 TYP 1/4"x3"x8" PL WITH (2) 1/2" BOLTS THRU TRUSS CHORD 3 TYP EW1 3/16 TYP +0'-0" Job No: 13108 Date: 5-2-14 Sheet No: 3 EAST-WEST BUILDING SECTION 1/4" = 1'-0" 5 ENLARGED MECHANICAL SCREEN SECTION 3/4" = 1'-0" A4.1 6 A8.1 PT-1 8'-2'' FIXTURE PT-1 PT-5 PT-3 5'-8" 2 A8.2 PL-4 PT-3 5 A8.2 5 A8.2 2 A8.2 SIM PT-3 3 2'-6" PL-4 PT-5 PL-1 A) WEST ENTRY 100/WAITING 101 1/4" = 1'-0" Digitally signed by Lisa McClellan Date: 2014.05.05 11:36:49-07'00' 5 A8.1 TYP (** = FIXTURE DIMENSION) 36" MAX. 24" MAX. 9" 7 27" MIN. 8 A8.1 17" TO 19" 4 A8.1 30X48 CLR. FLR. AREA 1 B) NORTH 6" MAX. 8" MIN. C) EAST 1 D) SOUTH 12 A8.1 ENTRY 100/WAITING 101 CONT'D BEAVERTON SCHOOL DIST. SBHC FACILITY 13000 SW 2ND STREET 1/4" = 1'-0" BEAVERTON, OR 97005 PT-3 PT-5 PT-6 2 A8.2 2 A8.2 2 A8.2 2 A8.2 SIM 8'-2" PL-1 SIM 6 A8.2 SIM PL-4 1 6 A8.2 PL-4 PT-6 PT-5 A) WEST 2 B) NORTH C) EAST PT-6 E) NORTH D) SOUTH RECEPTION 102 1/4" = 1'-0" 6 A8.2 CG 4'-6" PL-4 C ALIGN COUNTER SUPPORT W/ WALL 4'-2" A D 2 ANGLE SUPPORTS BELOW COUNTER A6.1 B 2 A6.1 E C GENERAL NOTES: CG C 2 A8.2 6 A8.2 4" 4" RETURN COUNTER TO FLOOR 3'-5" 2" 11" 1'-7" PL-1 ENLARGED RECEPTION PLAN RETURN COUNTER TO FLOOR 2" ANGLED FACE PANEL BELOW (DASHED) 1/2" = 1'-0" 1. ALL DIMENSIONS TO FACE OF FINISH U.N.O. 2. SEE RCP FOR CEILING HEIGHTS. 3. ALL WALLS TO BE PAINTED PT-1 UNLESS NOTED OTHERWISE. SEE ELEVATOR FOR ACCENT WALL PAINT. 4. 8'-3" 3 PT-5 PL-4 5. KEYNOTES: 1 FIRE ALARM AND CONTROL PANELS, COORDINATE WITH OWNER PROVIDE IN WALL BLOCKING AS REQUIRED FOR CASEWORK, EQUIPMENT & FIXTURES. 2 CORNER GUARD, SEE FLOOR PLAN FOR LOCATIONS ALL CABINETS TO BE SCRIBED FOR FLUSH INSTALLATION WHERE REQUIRED. 3 FIXED PLAM SHELF FLUSH W/WALL IN NICHE 6. X = ACCESSORY TAG SEE ACCESSORY SCHEDULE A5.2 4 LIGHT FIXTURE, SEE RCP SHEET A2.1 7. EPOXY PAINT AT ALL RESTROOM WALLS, TYP. SEE SPEC. 5 EQUIP, FURNISHINGS BY OWNER 8. ADJUSTABLE SHELVES GREATER THAN 24" IN WIDTH SHALL BE A MINIMUM THICKNESS OF 1" 6 WALL MOUNTED PROJECTOR SCREEN 9. VERIFY ALL LOCATIONS FOR WALL MOUNTED EQUIPMENT WITH OWNER PRIOR TO INSTALLATION OF BLOCKING. 7 DRINKING FOUNTAIN -SEE ADJACENT MOUNTING REQUIREMENTS 10. WALL BASE SHALL BE B-1 U.N.O. 11. SEE CABINETRY DETAILS ON A8.2 FOR LOCK INFORMATION 5'-8" Drawing: INTERIOR ELEVATIONS Job No: 13108 Date: 5-2-14 Sheet No: A6.1 4'-5" 4 EQ. 3'-0" 3'-0" 2'-2" 7 A8.2 B) NORTH A) WEST 8 A8.2 A) WEST 8 A8.2 8 A8.2 6'-4" 5 EQ. 1 4 A8.2 1'-8" 3'-0" 2'-0" 3'-0" 3'-0" A) WEST 6'-11" 6 EQ. 4 A8.2 2'-0" 4 A8.2 3'-0" 4 A8.2 5'-5" 5 EQ. 2'-10" 7'-2" 7 EQ. 3'-7" 3 EQ. 12 A8.2 2'-6" SUPPORT 103 2 1/4" = 1'-0" SECURE STORAGE 104 3 1/4" = 1'-0" 2'-6" B) SOUTH 1'-9" Digitally signed by Lisa McClellan Date: 2014.05.05 11:36:57-07'00' GROUP 108 1/4" = 1'-0" 3'-11" 3 EQ. 8'-4'' FIXTURE 4'-1 1/2" 9 A8.2 3'-0" BEAVERTON SCHOOL DIST. SBHC FACILITY T A) WEST B) SOUTH 13000 SW 2ND STREET C) EAST BEAVERTON, OR 97005 4 HALLWAY 112/STORAGE 113/114 1/4" = 1'-0" 3'-2" 2 EQ. 5'-4" 5 EQ. 2'-0" 2'-0" 2'-6" 3'-0" 3'-0" 4 A8.2 CA CHART SHARPS SOAP 1'-8" 1'-8" PT GLOVE A) WEST 5 3'-0" 2'-10" REF B) SOUTH A) EAST 11 A8.2 5'-4" 4 EQ. BREAK ROOM 115 B) SOUTH 11 A8.2 8 A8.2 6 1/4" = 1'-0" 1'-6" DENTAL 117 2'-6" 8 A8.2 2'-6" 1/4" = 1'-0" 4'-0" TYP. Drawing: INTERIOR ELEVATIONS 3'-0" 11 A8.1 CHART EQ RA PT SOAP GLOVE A) WEST B) NORTH C) EAST 3'-0" CA SEE SHEET A6.1 FOR BALANCE OF GENERAL NOTES AND KEYNOTES D) SOUTH 8 A8.2 7 CARE ROOM 118, 119, 121, 122 1/4" = 1'-0" 1'-8" SHARPS 11 A8.2 4'-0" 3 EQ. Job No: 13108 Date: 5-2-14 Sheet No: A6.2 7'-6" 5 EQ. 2'-4" 9'-6" 6 EQ. 4 A8.2 5'-9" 4 EQ. 4 A8.2 4 A8.2 2'-6" 4'-0" 2'-0" 4'-0" 4'-0" 4 A8.1 2'-0" 4'-0" CLR REF PL-3 9 REF BLOOD DRAW 3'-0" 3'-0" VAC 3'-0" BLOOD DRAW PL-2 2'-0" 4 A8.1 SPEC A) WEST A) WEST B) NORTH 8 A8.1 2'-4" 1 MENTAL HEALTH 123 2 1/4" = 1'-0" C) EAST 7 12 A8.2 A8.2 1'-9 3/4" 2'-0" 7 A8.2 D) SOUTH 12 A8.2 1'-6" 11 A8.2 2'-6" 12 A8.2 1'-6" 7 A8.2 8 A8.2 2'-2 1/4" 11 A8.2 3'-0" 7 A8.2 1'-9 3/4" Digitally signed by Lisa McClellan Date: 2014.05.05 11:37:04-07'00' LAB 124 1/4" = 1'-0" 6'-0" 6 EQ. 3'-6" 4 A8.2 1 6 WEIGH ALCOVE 3'-0" 5 3 BEAVERTON SCHOOL DIST. SBHC FACILITY 5 4 A) SOUTH A) WEST 11 A8.2 3 8 2 1'-8" 8'-2" OPEN TO RECPT 6'-0" 4 EQ. PREP AREA 125 B) NORTH C) EAST 8 A8.2 13000 SW 2ND STREET D) SOUTH B2 4 1/4" = 1'-0" BEAVERTON, OR 97005 RESTROOM 109 1/4" = 1'-0" 1 6 9 4 A) WEST 8 5 7 B) NORTH C) EAST 3 A8.2 D) SOUTH B2 RESTROOM 110 1/4" = 1'-0" ACC. MOUNTING AND CLEARANCE REQS: 3. RECESSED TOWEL DISPENSER / WASTE RCPT BOBRICK B-43944 4. TOILET TISSUE ROLL DISPENSER BOBRICK B-4288 5. GRAB BARS: 1 1/2" SMOOTH, 18", 36" AND 48" BOBRICK B-6806 7"-9" MIRROR 48" MAX BY OWNER 1/4" = 1'-0" - DIMENSIONS ARE FROM FACE OF FINISH AND/OR CENTERLINE OF FIXTURE OR ACCESSORY HIGHEST OPERABLE PART SOAP DISPENSER 34" MAX. 2. 29" MIN. BOBRICK 27" MIN. MIRROR 9" B-290-2448 1. FILE: L:\AUTOCAD\BLOCKS\00_BATHROOM\ACCESSORIES.DWG - PROVIDE SOLID BLOCKING FOR FIXTURES AND ACCESSORIES TYPICAL 40" MAX. MODEL 1 1/2" MIN. BRAND 17"-19"** DESCRIPTION 39" TO 41" X (** = FIXTURE DIMENSION) 39" TO 41" 33" TO 36" ACCESSORY SCHEDULE: 18" MIN. BASED ON 2010 OSSC 15" MIN. SEE SHEET A6.1 FOR BALANCE OF GENERAL NOTES AND KEYNOTES Drawing: INTERIOR ELEVATIONS 6" MAX. (TOE) 8" MIN. (KNEE - HIGH) 7. BABY CHANGING STATION KOALA KARE KB111-SSWM 8. PURSE / COAT HOOK BOBRICK B-6717 9. SPECIMAN PASS-THRU BOBRICK B505 3'-0" MIN. B-4221 FLUSH VALVE OPPOSITE WALL 60X56 CLR. FLR. AREA 30X48 CLR. FLR. AREA 48" MIN. BOBRICK 17"-25" TOE 25" MAX. KNEE 30" MIN. SEAT COVER DISPENSER 15" MAX 6. 16"-18" 12" MAX. 4'-6" MIN. 42" MIN.** 24" MAX. 11" MIN. (KNEE - LOW) 24" MIN. 12" MIN. 5 3 3'-5" 5 2 36" MIN. ALCOVE FORWARD APPROACH 60" MIN. ALCOVE PARALLEL APPROACH Job No: 13108 Date: 5-2-14 Sheet No: A6.3 X EXISTING CMU OPENING BACKER ROD AND CAULK EA. SIDE FRAMING SHOWN FOR REFERENCE ONLY NOTE: NO FURRED WALL ABOVE DOOR IN WAITING 101 "VERTI CLIP" DEFLECTION CLIP SYSTEM @ STUD BLOCK AND SHIM AS REQUIRED. R.O. METAL CORNER BEAD AT EXPOSED TOP & TRANSITION EDGES TYP. CURRIES STEEL FRAME DOOR -SEE DOOR SCHEDULE NOTE: APPLICABLE TO WOOD AND/OR METAL STUDS - SEE PLAN FOR SIZES 1 2" Digitally signed by Lisa McClellan Date: 2014.05.05 11:37:12-07'00' PT PLYWOOD CONTINUOUS FURRING UNDER GBD RETURN HEAD FLASHING IN SEALANT BED TO ROUGH OPENING STUD FRAMING CLIP SYSTEM CURRIES STEEL FRAME STEEL WINDOW 1 DEFLECTION HEAD DETAIL 2 3" = 1'-0" NOT USED 3" = 1'-0" FASTEN TO STRUCTURE, 100# PULLOUT MIN.; TYP. TYP. HEAD @ DOOR 3 WINDOW HEAD DETAIL - MH ROOM 123 4 3" = 1'-0" 3" = 1'-0" WAITING 101 SIMILAR FIXED INSULATED GLAZING @ LOWER PANEL, STEEL CASEMENT @ UPPER (SHOWN) X LED STRIP LIGHT FIXTURE MOUNTED ON BACK OF SOFFIT LIP -SEE E0.1 5" 8" MAX. CURRIES STEEL FRAME DOOR -SEE DOOR SCHEDULE 4" TYP FLEXIBLE SHEET METAL STABILIZER EXISTING CMU OPENING BACKER ROD AND CAULK EA. SIDE 9 GA. HANGER WIRE @ 48" O.C. 1/2" PT PLYWOOD CONTINUOUS FURRING UNDER GBD RETURN FRAMING SHOWN FOR REFERENCE ONLY 1" 1-1/2" CHANNELS @ 48" O.C. BEAVERTON SCHOOL DIST. SBHC FACILITY 13000 SW 2ND STREET BEAVERTON, OR 97005 6 1/4" PT BLOCKING METAL CORNER BEAD AT EXPOSED TRANSITION EDGES TYP. CURRIES STEEL FRAME NOTE: TRAPEZE DUCTWORK AND OTHER LARGE OBSTRUCTIONS MTL FURRING @ 24" O.C. NOTE: REFER TO A.9.2 REGARDING REFRENCE STANDARDS FOR PRESCRIPTIVE PATH SUSPENSION SYSTEMS FOR LAY-IN CEILINGS. USE NWCB FIELD TECHNICAL INFORMATION BULLETIN 401-OREGON 4/07 5 8" SEE RCP FOR CEILING HT. FRAMING SHOWN FOR REFERENCE ONLY SEE RCP FOR CEILING HT. 1" 4" NEW FURRED STUD WALL AND WINDOW RETURN WHERE SHOWN ON PLAN SEE ASSEMBLY SCHEDULE FOR WALL TYPE INFO TYPICAL SOFFIT RETURN 6 3" = 1'-0" LIGHT SOFFIT AT RECEPTION 3" = 1'-0" TYP. JAMB @ DOOR (HINGE SHOWN) 7 3" = 1'-0" 3'-9" HATCH AREA INDICATES MIN. EXTENT OF BLOCKING REQUIRED WAITING 101 SIMILAR 3" = 1'-0" 2'-4" 3" 4" 5" 4" 4" LINE OF MONITOR ARM TRACK WINDOW JAMB DETAIL - MH ROOM 123 8 X 5'-4" METAL STUD FRAMING 2'-10" PHONE JACK DATA JACK OUTLET (60" A.F.F.) BETWEEN ARM & DOOR ARM AND ARM SWING SHOWN DASHED CURRIES STEEL FRAME - PER MANUF. INSTALLATION -SHIM AS DIRECTED EXISTING ENTRY SLAB 4" 5'-0" METAL BOTTOM TRACK HOLD GYPSUM BOARD UP OFF CONC. FLOOR SURFACE PREFINISHED SILL PAN FLASHING - BACKER ROD AND CAULK EA. SIDE FLOORING PER SCHEDULE WALL WITH DOOR CONC EXPANSION ANCHOR EXISTING CONCRETE FLOOR CABINET NOTE: 1. COORDINATE MOUNTING LOCATION WITH MANUFACTURER AND OWNER. TYPICAL WALL TO CONC SLAB 3" = 1'-0" DETAILS 10 NOT USED 3" = 1'-0" 11 COMPUTER MONITOR ARM DETAIL 3" = 1'-0" Job No: 13108 Date: 5-2-14 Sheet No: 2. ORIENTATION RELATIVE TO DOORWAY AND CABINETRY, FLIP AS NECESSARY. 9 Drawing: 2'-6" 1/2" SCHEDULED BASE typ. FIXED INSULATED GLAZING @ LOWER PANEL, STEEL CASEMENT @ UPPER 12 SILL DETAIL - STEEL WINDOW TO SLAB 3" = 1'-0" A8.1 PLAM FACE PANEL ON HIGH DESK IS @ ANGLE SEE 3/A6.1 NOTE: GLUE & SCREW 3/4" AC EXT. PLYWOOD JOINTS TYP. PL-4 P-LAM ON COUNTERTOP, NOSE, APRON, AND BACKSPLASH 17" MAX. HC. 3'-6" 4" 2" 2" 2" 4" 4 5 1/2" 2 4 2 " x 1 " x 3/16" x 2'-0" x 10" MAX. BRACKETS @ ADA COUNTER - MITER & WELD @ 90°, ANCHOR TO SOLID BLKG IN DBL 4" STUDS W/ (3) 1/2" DIA M.B.s W/ FLAT WASHERS PL-4 P-LAM ON 3/4" FULL FLUSH OVERLAY DOORS. USE WIRE STYLE PULLS, ALL HARDWARE TO BE CONCEALED. PL-3 2'-0" RADIUSED CORNER, PAINT 2'-6 1/2" 4" 2" OLYMPUS 100DR 200DW COORDINATE LOCKING PER BSD STANDARDS PRIOR TO CABINET CONSTRUCTION -VERIFY W/ARCHITECT 2 PROVIDE 2X BLOCKING AS REQUIRED 1'-2" 34" TO F.F. (TO SINK RIM.) CL 1 1/2" 3" PL-4 1 1/2" P-LAM ON COUNTERTOP 2" 2" SEE CEILING PLANS FOR ABOVE CABINET CONDITIONS WRAP BACKSPASH TO SIDE WALL 4" 2" 3" 4" 4" 2 " x 1 " x 3/16" x 2'-0" x 10" MAX. BRACKETS @ ADA COUNTER MITER & WELD @ 90°, ANCHOR TO SOLID BLKG IN DBL STUDS W/ (3) 1/2" DIA M.B.s W/ FLAT WASHERS SEE INTERIOR ELEVATIONS PL-1 L 2 1/2"X2 1/2"X3/16"X2'-0"X2'-6" -MITER & WELD @ 90^ W/ (4) 1/2"~ M.B. W/ FLAT WASHERS TO DBL STUDS PL-4 ADJUSTABLE SHELF (2 PER CAB, TYP) FINISH UNDERSIDE OF COUNTER SAME AS TOP AND FACE SCHEDULED BASE PLAM ON PLYWOOD DESK FRONT Digitally signed by Lisa McClellan Date: 2014.05.05 11:37:19-07'00' UNDER CABINET LIGHTING (MAY OCCUR) PL-1 OWNER PROVIDED EQUIPMENT DASHED SCHEDULED BASE 1 1/2" 1 1/2" 3" PL-4 RADIUSED CORNER 2'-6" 2 " x 1 " x 3/16" x 2'-0" x 10" MAX. BRACKETS @ ADA COUNTER MITER & WELD @ 90°, ANCHOR TO SOLID BLKG IN DBL 4" STUDS W/ (3) 1/2" DIA M.B.s W/ FLAT WASHERS SCHEDULED BASE NICHE LEDGE SECTION NOTE: 3/4" NOSE AT PORTIONS ABOVE UNDER CABINET REF. -COORDINATE WITH MANUFACTURERS INSTALLATION INSTRUCTIONS SUPPORT COUNTER END AT WALL WITH LEDGER OR OVER BASE CABINET ADJACENT BASE CABINET SHOWN DASHED * 2'-0" ELIGABILITY DESK SECTION 1" = 1'-0" P-LAM 3/4" FULL FLUSH OVERLAY DOORS & DRAWER FACES. SEE SPECIFICATION FOR PULLS, AND HARDWARE BEAVERTON, OR 97005 PL-4 VENT IN DOOR FACE @ * DENTAL CABINET SEE 6B/A6.2 SCHEDULED BASE SCHEDULED BASE 2" CONDUIT SLEEVE FROM *POWERBOX TO EQUIPMENT IN CABINET -COORDINATE FINAL LOCATION SCHEDULED BASE 6 13000 SW 2ND STREET * HOLE & GROMMET @ DENTAL 1" = 1'-0" TRIM BLOCK AT CEILING WHERE NEEDED DRAWER MAY NOT OCCUR, SEE INTERIOR ELEVATIONS PROVIDE 2X BLOCKING AS REQUIRED * PROVIDE 2X BLOCKING AS REQUIRED FINISH UNDERSIDE OF COUNTER SAME AS TOP AND FACE BEAVERTON SCHOOL DIST. SBHC FACILITY 1 1/2" 2'-1" PL-4 PROVIDE 2X BLOCKING AS REQUIRED 2'-10" 2'-4" P-LAM ON COUNTERTOP AND BACKSPLASH 2'-1" 6" 1'-10" P-LAM ON COUNTERTOP W/ 1 1/2" NOSE TO RECEPTION, 3" TO ELIGABILITY & WAITING 1" = 1'-0" P-LAM ON COUNTERTOP AND BACKSPLASH 4" 3" TYPICAL WALL -REINFORCE FRAMING AT TOP FOR POTENTIAL COUNTER LOAD 5 1" = 1'-0" 2 " x 1 " x 3/16" x 2'-0" x 10" MAX. BRACKETS @ ADA COUNTER MITER & WELD @ 90°, ANCHOR TO SOLID BLKG IN DBL STUDS W/ (3) 1/2" DIA M.B.s W/ FLAT WASHERS PL-4 TYPICAL UPPER CABINET SECTION 4 1'-10" 1" = 1'-0" P-LAM ON COUNTERTOP W/ 3" NOSE COUNTERTOP FIXED TO FRAMED WALL BELOW ON WEST SIDE, REMOVABLE AT EAST SIDE FOR WATER SHUT OFF 1'-6" REST ROOM VANITY 3 4" NTS RECEPTION DESK SECTION 4" 2 SEE ELEVATIONS LOCKING DIAGRAM SEE ELEVATIONS 1 OPEN BASE CABINET SECTION 7 1" = 1'-0" 8 * @ DENTAL ONLY SEE 6B/A6.2 TYPICAL BASE CABINET W/DOOR 1" = 1'-0" P-LAM FULL FLUSH OVERLAY DOORS. SEE SPECIFICATION FOR PULLS AND HARDWARE 4'-2" PL-4 ADJUSTABLE SHELVES (3 ) P-LAM ON COUNTERTOP AND BACKSPLASH P-LAM ON COUNTERTOP AND BACKSPLASH P-LAM ON COUNTERTOP AND BACKSPLASH PROVIDE 2X BLOCKING AS REQUIRED 4" 6" 6" CASEWORK DETAILS PROVIDE 2X BLOCKING AS REQUIRED SCHEDULED BASE SCHEDULED BASE Job No: 13108 Date: 5-2-14 Sheet No: SCHEDULED BASE FULL HEIGHT CABINET SECTION Drawing: 2'-0" PROVIDE 2X BLOCKING AS REQUIRED 4" P-LAM 3/4" FULL FLUSH OVERLAY DOORS & DRAWER FACES. SEE SPECIFICATION FOR PULLS, AND HARDWARE PL-4 4" 2'-8" PL-4 PROVIDE 2X BLOCKING AS REQUIRED SCHEDULED BASE 1" = 1'-0" 2'-0" P-LAM 3/4" FULL FLUSH OVERLAY DOORS & DRAWER FACES. SEE SPECIFICATION FOR PULLS, AND HARDWARE SEE INT. ELEVATIONS L 2 1/2"X2 1/2"X3/16"X6'-1/2"~ M.B.s W/ FLAT WASHERS TO DBL STUDS BOTH ENDS AND BLOCK BELOW SEE ELEVATIONS 2'-6" ALIGN ADJUSTABLE SHELF 9 1 1/2" 4" 6" 4" 1 1/2" PL-1 4" 1'-8" 2'-1" 2'-1" 10 SECURE STORAGE COUNTER SECTION 1" = 1'-0" 11 SINK BASE CABINET SECTION 1" = 1'-0" 12 TYPICAL BASE CABINET W/DRAWERS 1" = 1'-0" A8.2 1. REVIEW ACCENT WALL LOCATIONS WITH ARCHITECT PRIOR TO PAINTING. 2. SEE A2.3 FOR MORE DETAIL. N/A PT-1,3,5 GWB PT-1 GWB PT-5 GWB PT-3,5 A GWB 101 WAITING CPT-1 B-1 GWB 102 RECEPTION CPT-1 B-1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 103 SUPPORT CPT-1 B-1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 104 STORAGE CPT-1 B-1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 105 ELIGIBILITY CPT-1 B-1 GWB PT-6 N/A GWB PT-3,5 106 RESOURCE (NICHE) CPT-1 B-1 N/A PT-1 GWB PT-5 GWB PT-5 GWB PT-5 107 HALL CPT-1 B-1 GWB PT-5 GWB PT-5 GWB PT-1 GWB PT-1 108 GROUP CPT-1 B-1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 109 RESTROOM CONC. B-2 GWB PT-1 GWB PT-3 GWB PT-3 GWB PT-1 110 RESTROOM CONC. B-2 GWB PT-1 GWB PT-3 GWB PT-3 GWB PT-1 111 SERVER CONC. B-1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 112 HALL CONC. B-1 GWB PT-1 GWB PT-1,5 GWB PT-1 GWB PT-1 113 STORAGE CONC. B-1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 114 JANITOR CONC. B-1 GWB, FRP-1 PT-1 GWB, FRP-1 PT-1 GWB, FRP-1 PT-1 GWB, FRP-1 PT-1 115 BREAK ROOM CONC. B-1 GWB PT-1 GWB PT-3 GWB PT-1 GWB PT-1 116 MECHANICAL CONC. B-1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 117 DENTAL CONC. B-1 GWB PT-4 GWB PT-1 GWB PT-1 GWB PT-1 118 CARE ROOM CONC. B-1 GWB PT-4 GWB PT-1 GWB PT-1 GWB PT-1 119 CARE ROOM CONC. B-1 GWB PT-4 GWB PT-1 GWB PT-1 GWB PT-1 120 HALL CONC. B-1 GWB PT-1 GWB PT-1 GWB PT-3 GWB PT-1 121 CARE ROOM CONC. B-1 GWB PT-4 GWB PT-1 GWB PT-1 GWB PT-1 122 CARE ROOM CONC. B-1 GWB PT-4 GWB PT-1 GWB PT-1 GWB PT-1 123 MH ROOM CPT-1 B-1 GWB PT-1 GWB PT-5 GWB PT-5 GWB PT-1 124 LAB CONC. B-1 GWB PT-1 GWB PT-1 GWB PT-1 GWB PT-1 125 PREP (NICHES) CONC. B-1 N/A PT-1 GWB PT-3 GWB PT-3 GWB PT-3 126 HALL CONC. B-1 GWB PT-1 GWB PT-1 GWB PT-5 GWB PT-1 127 TEAM CPT-1 B-1 GWB PT-3 GWB PT-1 GWB PT-1 GWB PT-1 128 MP OFFICE CPT-1 B-1 GWB PT-1 GWB PT-5 GWB PT-1 GWB PT-1 129 CM OFFICE CPT-1 B-1 GWB PT-1 GWB PT-5 GWB PT-1 GWB PT-1 N/A B 100A ENTRY C 3 +- 3'-10" X 7'-0" +- 101A WAITING D 1 3'-0" X 7'-0" 104A STORAGE A 1 107A HALL D 108A GROUP ROOM 109A FIRE RATING PT-5 B-1 EXTERIOR FINISH GWB WOM 1. ALL DOOR AND RELITE GLAZING TO BE TEMPERED 2. SEE SPECIFICATIONS FOR HARDWARE TYPES INTERIOR FINISH PT-5 ENTRY NOTES KNOCKDOWN GWB 100 HOLLOW METAL FIN. PAINT PAINT EXISTING OPENING V.I.F. X MFGR MFGR CARD READER WOOD X MFGR MFGR DOOR CONTACT (ALARMED) WOOD WOOD X MFGR MFGR CARD READER X WOOD WOOD X MFGR MFGR 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR B 1 2'-8" X 7'-0" X WOOD WOOD X MFGR MFGR STORAGE A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 114A JANITOR A 1 2'-8" X 7'-0" X WOOD WOOD X MFGR MFGR 115A BREAK ROOM A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 116A MECHANICAL ROOM A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 117A DENTAL A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 118A CARE ROOM A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 119A CARE ROOM A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 120A HALL C 3 3'-0" X 7'-0" HM HM PAINT PAINT 121A CARE ROOM A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 122A CARE ROOM A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 123A MH ROOM A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 124A LAB B 1P 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 128A MP OFFICE A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR 129A CM / OFFICE A 1 3'-0" X 7'-0" X WOOD WOOD X MFGR MFGR A WAITING F 4 3'-10" X 7'-0" X HM HM X PAINT PAINT EXIST'G OPENING V.I.F. DOOR CONTACT (ALARMED) B MH OFFICE F 4 3'-4" X 7'-0" X HM HM X PAINT PAINT EXIST'G OPENING V.I.F. DOOR CONTACT (ALARMED) HM HM X WOOD WOOD 3'-0" X 7'-0" X WOOD 1 3'-0" X 7'-0" X D 1 3'-0" X 7'-0" RESTROOM A 1 110A RESTROOM A 111A SERVER ROOM 113A X X WOOD FIN. MAT. EXTERIOR FINISH PT-5 FIN. MAT. FRAME INTERIOR FINISH FIN. MAT. DOOR ROOM FINISH NOTES HOLLOW METAL MAT. WINDOWS WOOD BASE WEST DOOR SIZE MAT. SOUTH FRAME TYPE EAST DOOR TYPE NAME NORTH LOCATION NO. FLOOR DOOR & WINDOW SCHEDULE DOOR NUMBER ROOM FINISH SCHEDULE: X X DIRECT CONTACT (ALARMED) Digitally signed by Lisa McClellan Date: 2014.05.05 11:37:28-07'00' EXISTING OPENING V.I.F. POCKET DOOR & FRAME DOOR CONTACT (ALARMED) DOOR CONTACT (ALARMED) GENERAL NOTES: BEAVERTON SCHOOL DIST. SBHC FACILITY 13000 SW 2ND STREET 1 SEE REFLECTED CEILING PLAN FOR CEILING HEIGHT & FINISH 4 SEE INTERIOR ELEVATIONS & SECTIONS FOR EXTENT OF ACCENT PAINT 2 ALL WALLS TO BE PAINTED PT-1 U.N.O. 5 ALL GWB IN RESTROOMS TO RECEIVE EPOXY PAINT 3 ALL GWB CEILINGS TO BE PAINTED PT-2 U.N.O. 6 ALTERNATE # 1: LINO AT ALL CONC FLOORING EXCEPT SERVER 111. JAN 114 & MECH 116 FRAME TYPES 1. 2" SEE SCHED. 2" 2. 2" SEE SCHED. T T P-LAM / FRP CPT-1 CARPET TILE MANUF: MANNINGTON COMMERCIAL PRODUCT: 'SOCIAL' TILE PATT: VERITCAL ASHLAR PL-2 PLASTIC LAMINATE -COUNTERTOPS 'CLEAN' LAB MANUF: NEVAMAR PRODUCT: COOL CHIC VA7002T LINOLEUM SHEET ALTERNATE # 1 SUBSTITUTE LINO-1 FOR (E) CONC FLOORING MANUF: FORBO MARMOLEUM PRODUCT: REAL COLOR: EIGER 2629 PL-3 WOM-1 CARPET WALK OFF TILE MANUF: MATSINC (CONNEXUS) PRODUCT: HERCULES COLOR: CHARCOAL PL-4 PLASTIC LAMINATE -CABINET FACES & FRONT DESK MANUF: FORMICA PRODUCT: NATURAL CANE 6930-NT WOM-2 WALK OFF MAT MANUF: MATSINC (CONNEXUS) PRODUCT: BERBER VINYLBACK ENTRANCE MAT COLOR: CHARCOAL FRP-1 FIBER REINFORCED PANEL (JANITOR'S WAINSCOT) MANUF: KEMLITE GLASBOARD-P PRODUCT: 'IVORY' - 84, 0.09", PEBBLE FINISH LINO-1 NOT USED EXTERIOR H.M. W/ GLAZED OPENING EXTERIOR H.M. DOOR TYPES SCALE: 1/4" = 1'-0" 1. PLASTIC LAMINATE COUNTERTOPS 'DIRTY' LAB MANUF: NEVAMAR PRODUCT: SERENE STARDOM VA5001T SEE SCHED. SEE SCHED. SEE SCHED. 5" 5" VIF 5" 5" 6" COLOR: DISCLOSE 13210 INTERIOR TYP. P=POCKET 4 T PT-1 WALL BASE PAINT - INTERIOR (FIELD) MANUF: BENJAMIN MOORE COLOR: CHANTILLY LACE 2127-7 B-1 RUBBER BASE, 4" MANUF:JOHNSONITE PRODUCT: BURNT UMBER 63 PT-2 PAINT - INTERIOR (CEILING) MANUF: BENJAMIN MOORE COLOR: CHANTILLY LACE 2127-7 B-2 RUBBER BASE, 6" MANUF: JOHNSONITE PRODUCT: BURNT UMBER 63 PT-3 PAINT - INTERIOR (ACCENT) MANUF: BENJAMIN MOORE COLOR: ELECTRIC ORANGE 2015-10 PT-4 PAINT - INTERIOR (ACCENT) MANUF: BENJAMIN MOORE COLOR: TEQUILA LIME 2028-30 ACOUSTIC TILE CEILING ACT-1 ACOUSTIC TILE CEILING (TYPICAL) MANUF: ARMSTRONG PRODUCT: 895 24X48" WHITE T-BAR PT-5 PAINT - INTERIOR (ACCENT) MANUF: BENJAMIN MOORE COLOR: TAOS TAUPE 2111-40 PT-6 PAINT - INTERIOR (ACCENT) MANUF: BENJAMIN MOORE COLOR: BLACK BEAUTY 2128-10 10" T A B FLUSH POCKET 10" T INTERIOR PAINT 2. VERIFY ALL R.O. SIZES PRIOR TO DOOR FABRICATION. UNLESS NOTED OTHERWISE, SIZES SHOWN ARE NOMINAL. ALL GLASS TO BE LAMINATED OR TEMPERED SAFETY GLAZING. 6" PLASTIC LAMINATE -COUNTERTOPS TYPICAL & FRONT DESK MANUF: FORMICA PRODUCT: WHITE DROPS 8824-58 TRANSLUCENT GLAZING SEE SCHED. PL-1 3 VIF EXISTING CONCRETE SLAB MANUF: EXISTING & PATCH PER SPEC PRODUCT: TNEMEC SERIES 287 - EVVIRPOX, CLEAR 2 SEE SCHED. CONC 1 SEE SCHED. FLOORING VERIFY ALL R.O. SIZES PRIOR TO DOOR FABRICATION. UNLESS NOTED OTHERWISE, SIZES SHOWN ARE NOMINAL. ALL GLASS TO BE LAMINATED OR TEMPERED SAFETY GLAZING. CLEAR GLAZING PROVIDE LIMITER HARDWARE 2'-6" 2" SEE SCHED. VIF SEE SCHED. 2" SEE SCHED. VIF FINISH MATERIAL LEGEND BEAVERTON, OR 97005 SCALE: 1/4" = 1'-0" C H.M. W/ GLAZING D FLUSH Drawing: SCHEDULES: DOOR, WINDOW ROOM & FINISHES Job No: 13108 Date: 5-2-14 Sheet No: A9.1 SUSPENDED CEILING SYSTEMS - GENERAL REQUIREMENTS: NOTES: 1. SEE BUILDING AND WALL SECTIONS FOR ADDITIONAL INFORMATION ABOUT INSULATION INSTALLATION. ROOF TYPES: CEILING TYPE: TYPE LAY-IN ACOUSTIC PANELS OR DIRECT (SCREW) ATTACHED 5 8" LOAD CRITERIA: VERTICAL: 4 PSF. LATERAL: OSSC SEISMIC ZONE - SEE STRUCTURAL OSSC T1604.5 OCCUPANCY CATAGORY: SEE PROJECT MANUAL DUTY CLASSIFICATION: HEAVY-DUTY PER ASTM C-635. CROSS RUNNER DEFLECTION: L/360 MAX. GRID LIMITATIONS: MAXIMUM GRID SPACING: 4'X4'. INTERSTITIAL SPACE HEIGHT: 15' MAXIMUM. INTERIOR NON-BEARING PARTITIONS: INDEPENDENTLY SUPPORTED AND BRACED - SEE DETAILS. REFERENCE SOURCES PER HEIRARCHY: 2010 OSSC ASTM C 635, ASTM C636, ASTM E 580/E 580M ASCE 7-05, SECTION 13.5.6 CISCA - GUIDELINES FOR SEISMIC RESTRAINT FOR DIRECT HUNG SUSPENDED CEILING ASSEMBLIES - SEISMIC ZONES 3 &4. MAY, 2004 NWCB FIELD TECHNICAL INFORMATION BULLETIN 401 - REVISED 10/09 CITY OF PORTLAND - CODE GUIDE IBC/25/#2. A. MAIN RUNNERS 1 12" CROSS RUNNERS 7 8" B. EXISTING ROOF (NO CHANGE) EXISTING TORCH DOWN over EXISTING PLYWOOD SHEATHING over MANUFACTURED WOOD TRUSSES PROPRIETARY SYSTEM FIELD FRAMED SYSTEM COMPRESSION STRUT @ 12'-0"OC MAX EA WAY CROSS RUNNERS Digitally signed by Lisa McClellan Date: 2014.05.05 11:37:36-07'00' #12 WIRE BRACING @ 45^ & ALIGNED W/ EA RUNNER (4 DIRECTIONS) COLD FORMED STEEL 'C' CHANNEL, OR PRORIETARY 'T' SECTION MEETING HEAVY DUTY RATING, @ 48" O/C. 5 X 28" X 25 GA. CARBON SHEET STEEL HAT CHANNELS, OR PROPRIETARY 'T' SECTION MEETING DUTY RATING SPECIFIED ABOVE @ 2' O/C. MAIN RUNNERS EXISITING CEILING (NO CHANGE) 1 2" ACT over 1 2" GWB over 2X FURRING STRIPS #12 SWG GALVANIZED WIRE. #18 SWG GALVANIZED WIRE - DOUBLE STRAND. TENSION LOAD CAPACITY: 200# MIN. EA. 1 WOOD: 4"X3" SCREW EYES. 1 STEEL DECK: CMI DC1 OR DC 2 4" METAL DECK SCREW EYES. 1 3 CONCRETE: EMBEDS OR 4" X 4" METAL HIT ANCHORS. LATERAL BRACING - CEILINGS OVER 1,000 SF: PROVIDE 4 WIRES OF MINIMUM NO. 12 GAUGE IN 4 DIRECTIONS 90° APART, AND CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT TO EXCEED 45° FROM THE PLANE OF THE CEILING. THESE LATERAL SUPPORT POINTS SHALL PLACED 12' O.C. WALL. IN EACH DIRECTION WITH THE FIRST POINT WITHIN 4' FROM EACH 1 2"Ø 3 4"Ø EMT CONDUIT EMT CONDUIT 1"Ø EMT CONDUIT 5 (1) 1-8"X20GA METAL STUD 5 (2) BACK TO BACK 1- 8"X20GA METAL STUD 8" MAX C. 2" 5'-10" MAX LENGTH 7'-8" MAX LENGTH 9'-9" MAX LENGTH 12'-0" MAX LENGTH 15'-0" MAX LENGTH 48"OC TYP PERIMETER L @ STARTER WALL FIXED END NEW WALL TERMINATES AT UNDERSIDE OF EXISTING CEILING LID 8" MAX 1" MIN. CLR. TO ALL PENETRATIONS RUNNERS STABILIZER 3 4" D. 2" PERIMETER L @ OPPOSITE WALL FLOATING END PERIMETER CLOSURE - LAY-IN ACOUSTIC PANEL CEILINGS OVER 1,000 SF: E. VERTICAL SUPPORT: HANGER WIRES SHALL ATTACHE TO RUNNERS AND SUPPORT ABOVE WITH A MINIMUM OF THREE FULL TURNS WITHIN A 3 INCH LENGTH. F. FIXTURE SUPPORT: LIGHTING FIXTURES AND AIR DIFFUSERS SHALL BE SUPPORTED DIRECTLY BY 12 GAGE WIRES TO THE STRUCTURE ABOVE BY A MINIMUM OF 4 HANGERS ONE AT EACH CORNER. EXCEPTION: FIXTURES NOT OVER 56 POUNDS IN WEIGHT BUT MORE THAN 20 POUNDS IN WEIGHT, MAY BE SUPPORTED AND ATTACHED DIRECTLY TO THE CEILING SYSTEM RUNNERS W/IN 3" OF GRID INTERSECTIONS BY A POSITIVE ATTACHMENT SUCH AS SCREWS OR BOLTS. AND, SHALL HAVE (2) #12 GAGE HANGERS DIRECTLY FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE. THESE MAY BE SLACK. FIXTURES WHICH WEIGH NOT MORE THAN 20 POUNDS AND WHICH RECEIVE NO TRIBUTARY LOADING FROM DUCT WORK MAY BE POSITIVELY ATTACHED TO AND SUPPORTED BY THE CEILING RUNNERS ALONE. R-2 R-2i DROPPED CEILING SOUND BATT INSULATION (INSULATION ONLY IN R2i) over DIRECT HUNG SUSPENDED DRYWALL CEILING SYSTEM w/ (1) LAYER OF 5/8" GWB. R-3 R-3i DROPPED ACT CEILING (SIMILAR TO R-2) SOUND BATT INSULATION (INSULATION ONLY IN R3i) over SUSPENDED ACOUSTICAL CEILING SYSTEM BEAVERTON SCHOOL DIST. SBHC FACILITY 13000 SW 2ND STREET NOTES: 1. SEE SPECIFICATIONS FOR FURRING, SIDING AND SHEATHING FASTENING. 2. PROVIDE TILE BACKER IN LIEU OF GWB BEHIND TILE AT ALL LOCATIONS INDICATED ON INTERIOR ELEVATIONS. WALL TYPES: BEAVERTON, OR 97005 56# + GRID HANGER TYPE DESCRIPTION RATING EXTERIOR WALLS EW-1 EXISTING EXTERIOR 8" CMU WALL 1" AIR SPACE 4" MTL. STUDS AT 16" O.C. with BATT INSULATION PER SPECIFICATIONS with (1) LAYER 5/8" GWB @ INTERIOR EW-2 EXISTING EXTERIOR CMU WALL PATCH & PAINT ONLY G.L. E. MAIN RUNNERS SHALL BE HUNG USING SPECIFIED WIRE AT MINIMUM 4' O/C AND; CROSS RUNNERS AND MAIN RUNNERS SHALL BE SUPPORTED WITH ADDITIONAL HANGER WIRES WITHIN 8" OF ANY DISCONTINUOUS END, INCLUDING PERIMETER SUPPORT ANGLES. HANGERS SHALL NOT PRESS AGAINST PIPES OR DUCTS. HANGERS MORE THAN 1:6 OUT OF PLUMB SHALL HAVE COUNTERSLOPING WIRES ADDED. COUNTERSLOPING HANGERS SHALL BE INSTALLED WITH A MINIMUM 45 DEGREE ANGLE FROM HORIZONTAL. PROVIDE A TRAPEZE MADE OF MAIN RUNNER STOCK WHERE OBSTRUCTIONS TO STRUCTURE REQUIRE DIRECT ATTACHEMENT. CEILING (1) LAYER OF 5/8" GWB. APPLIED DIRECTLY TO UNDERSIDE OF EXISTING GRID HANGER PROVIDE 1" CLEAR ON ALL SIDES OF PENETRATIONS. STABILIZER BARS - LAY-I N ACOUSTIC PANEL CEILINGS OVER 1,000 SF. GRID MEMBERS PERPENDICULAR TO THE WALL AT THE UNATTACHED SIDES OF THE GRID SHALL BE TIED TOGETHER (STABILIZED) AT A POINT NOT MORE THAT 8" FROM AND PARALLEL TO THE WALL, TO PRVENT THEIR SPREADING R-1 (4) #12 DIRECTLY ON FIXTURES PERIMETER SUPPORT ANGLE SHALL BE ATTACHED TO WALL FRAMING WITH MINIMUM #6 SCREW @24" O/C MAX AND, ANGLE SHALL HAVE A MINIMUM 2" HORIZONTAL LEG. ONE END OF GRID SHALL BE ATTACHED TO THE CLOSURE ANGLE AT EACH OF TWO ADJACENT WALLS W/ RIVETS. THE OPPOSITE END OF THE GRID IN EACH HORIZONTAL DIRECTION WILL REST FREE UPON THE SUPPORT ANGLE W/ 3 / 4" CLEARANCE BETWEEN GRID END AND WALL. D. N/A A. COMPRESSION STRUT: LOCATE AT AND CENTER ON ALL LATERAL SPLAY WIRE LOCATIONS NOTED ABOVE. ATTACHED RIGIDLY FROM MAIN RUNNER TO STRUCTURE ABOVE. C. 2" MAX RATING G.L. B. SYSTEM COMPONENTS: SUSPENSION WIRE TIE WIRE ANCHORS 2" MAX GYPSUM WALL BOARD. DESCRIPTION ROOFS N/A (2) #12 SAFETY HANGERS GRID HANGER 20#-56# GRID HANGER TYPE DESCRIPTION RATING INTERIOR WALLS W1 INTERIOR - 4" METAL STUD W2 INTERIOR -6" METAL STUD (LAB POCKET DOOR) N/A (1) LAYER 5/8" GWB over METAL STUDS @ SPACING PER STRUCT. over (1) LAYER 5/8" GWB 3 21" ACOUSTIC BATT INSULATION- SEE SPECS. Drawing: NOTES: 1. SEE BUILDING AND WALL SECTIONS FOR FLOOR/CEILING TYPES. FLOOR TYPE: TYPE DESCRIPTION CONST ASSEMBLIES RATING FLOORS / CEILINGS N/A F-1 SLAB ON GRADE FLOOR WHERE INDICATED, CARPET TILE/WOM/LINO over EXISTING CONC. SLAB ON GRADE Job No: 13108 Date: 5-2-14 Sheet No: A9.2
© Copyright 2025 ExpyDoc