MBS AG - Beving

Split-core current transformers
We make energy measurable and take care of your future
www.mbs-ag.com
MBS AG
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Page 2
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
MBS AG
Split-core current transformer, type KBU
Features / benefits
-
Perfect for subsequent assembly into already existing installations
Easy and safe mounting, due to hearable locking system
Deliverable with secondary current 5 A / 1 A
Deliverable also in accuracy class 0.5
Four different construction types
General technical specifications
- Operating temperature: -5°C < T < +40°C
- Storage temperature: -25°C < T < +70°C
- Therm. nominal continuous rated current Icth: 1.0 x IN
- Therm. nominal short-time current Ith: 60 x IN, 1 sec.
- Max. operating voltage Um: 0.72 kV
- Isolation test voltage:
3 kV, Ueff, 50 Hz, 1 min.
- Rated frequency: 50 Hz
- Isolation class:
E
- Applicable technical standard: DIN EN 61869, part 1 + 2
Dimensions
Type
KBU 23
KBU 58
KBU 812
KBU 816
A
(width)
[ mm ]
93
125
155
195
B
(height)
[ mm ]
106
158
198
243
C / C1
(depth)
[ mm ]
34 / 58
34 / 58
34 / 58
64 / 79
D
[ mm ]
E
[ mm ]
F
[ mm ]
G
[ mm ]
23
55
85
85
33
85
125
165
64
96
126
156
56
56
56
62
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
Page 3
MBS AG
Order list KBU 23
5A
1A
Accuracy class
Accuracy class
Secondary current
Primary
current
[A]
100
150
200
250
300
400
Burden
[ VA ]
1.25
1.5
2.5
1.5
3.75
1
5
3
Art.-no.
80048
80030
80031
0.5
Art.-no.
1
Art.-no.
3
Art.-no.
80248
80230
80231
1
Art.-no.
80044
80045
0.5
80244
80245
80037
80237
80046
80246
5A
1A
Accuracy class
Accuracy class
Order list KBU 58
Secondary current
Primary
current
[A]
250
300
400
500
600
750
800
1000
Burden
[ VA ]
1.5
2.5
1
2.5
2.5
5
2.5
5
2.5
5
2.5
7.5
5
10
1
Art.-no.
80061
80062
0.5
Art.-no.
1
Art.-no.
80261
80262
80038
80063
80238
80263
80054
80064
80254
80264
80055
80065
80255
80265
80056
80066
80256
80266
80057
80067
80257
80267
80058
80068
0.5
Art.-no.
80258
80268
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Page 4
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
MBS AG
Order list KBU 812
5A
1A
Accuracy class
Accuracy class
Secondary current
Primary
current
[A]
250
300
400
500
600
750
800
1000
1200
1250
1500
Burden
[ VA ]
1.5
2.5
2.5
2.5
5
2.5
5
2.5
2
2.5
7.5
5
10
5
10
7.5
15
7.5
15
1
Art.-no.
80091
80092
80093
0.5
Art.-no.
1
Art.-no.
80291
80292
80293
0.5
Art.-no.
80074
80094
80274
80294
80075
80095
80275
80295
80076
80096
80276
80296
80077
80097
80277
80297
80078
80098
80278
80298
80079
80099
80279
80299
80080
80100
80280
80300
80081
80101
80281
80301
Order list KBU 816
5A
1A
Accuracy class
Accuracy class
Secondary current
Primary
current
[A]
1000
1200
1500
1600
2000
2500
3000
4000
5000
Burden
[ VA ]
10
15
10
15
10
15
10
15
10
15
10
15
15
30
15
30
15
30
1
Art.-no.
80140
80141
80142
80143
80144
80145
80146
80147
80148
80149
80150
80151
80152
80153
80154
80155
80156
80157
0.5
Art.-no.
80110
80111
80112
80113
80114
80115
80116
80117
80119
80120
80122
80123
80124
80125
80126
1
Art.-no.
80340
80341
80342
80343
80344
80345
80346
80347
80348
80349
80350
80351
80352
80353
80354
80355
80356
80357
0.5
Art.-no.
80310
80311
80312
80313
80314
80315
80316
80317
80319
80320
80322
80323
80324
80325
80326
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
Page 5
MBS AG
Split-core current transformer, type KBR
Features / benefits
- Perfect for subsequent assembly into already existing installations
- Due to the „click“-system even a one-hand mounting is possible
- Deliverable with secondary 5 A / 1 A or as a current sensor (0…333 mV) or
measuring transducer (4…20 mA DC).
- Three different construction types
General technical specifications
- Length of connection cable: Sec. 1A:
Sec. 5A:
0…333 mV:
4…20 mA:
-
2.5 m, cross section 2x0.75 mm²
0.5 m, cross section 2x1.5 mm²
2.5 m, cross section 2x0.75 mm²
2.5 m, cross section 2x0.75 mm²
(Other lengths are possible on request)
Operating temperature: -5°C < T < +50°C
Storage temperature: -25°C < T < +70°C
Therm. nominal continuous rated current Icth: 1.2 x IN
Therm. nominal short-time current Ith: 60 x IN, 1 sec.
Max. operating voltage Um: 0.72 kV
Isolation test voltage:
3 kV, Ueff, 50 Hz, 1 min.
Rated frequency: 50 Hz
Isolation class:
E
Applicable technical standard: DIN EN 61869, part 1 + 2
Dimensions
Type
A (width)
[ mm ]
B (height)
[ mm ]
C / C1 (depth)
[ mm ]
D (diameter)
[ mm ]
KBR 18
KBR 32
KBR 44
41.6
59.2
72.2
64.5
96.4
120.6
55 / 67.3
75 / 89.2
85 / 98.1
18.5
32.5
44
Technical characteristics for the KBR with output signal 4…20 mA:
- 2-wire connection, auxiliary power via output circuit
- Auxiliary power: 24 V DC ± 15 %, PV = max. 1 VA
- Load-independent DC current: Live-zero, 4…20 mA
- External resistance: max. 300 Ω
- Current limit under overload: < 30 mA
- Residual ripple of the output current: ≤ 1 % p.p.
- Response time: < 300 ms
Wiring diagram of the KBR 44 (4…20 mA):
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Page 6
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
MBS AG
Order list KBR 18
5A
1A
Accuracy class
Accuracy class
Secondary current
Primary
current
[A]
50
75
100
125
150
200
250
Burden
[ VA ]
3FS5
Art.-no.
1FS5
Art.-no.
1
1
1.25
1.5
2
1
3
1.5
4
3FS5
Art.-no.
18-0001
18-0006
18-0011
18-0016
18-0021
0…333 mV AC
4…20 mA DC
Accuracy class
Accuracy class
1
Art.-no.
50
75
100
125
150
1
Art.-no.
18-1001
18-1006
18-1011
18-1016
18-1021
200
181026
250
18-1031
Output
0…333 mV AC
4…20 mA DC
Accuracy class
Accuracy class
1
Art.-no.
1
Art.-no.
100
32-1011
32-2011
125
32-1016
32-2016
150
32-1021
32-2021
200
32-1026
32-2026
250
32-1031
32-2031
300
32-1034
32-2034
400
500
600
32-1036
32-1038
32-1040
32-2036
32-2038
32-2040
Output
0…333 mV AC
4…20 mA DC
Accuracy class
Accuracy class
1
Art.-no.
1
Art.-no.
250
44-1001
44-2001
300
400
500
600
750
800
1000
44-1006
44-1011
44-1016
44-1021
44-1026
44-1031
44-1036
44-2006
44-2011
44-2016
44-2021
44-2026
44-2031
44-2036
Output
1FS5
Art.-no.
18-0027
18-0026
18-0032
18-0031
Primary
current
[A]
Order list KBR 32
5A
1A
Accuracy class
Accuracy class
Secondary current
Primary
current
[A]
100
125
150
200
250
300
400
500
600
Burden
[ VA ]
1.5
2.5
2.5
3
3
3
5
3
5
2.5
5
5
5
5
3FS5
Art.-no.
32-5011
1FS5
Art.-no.
3FS5
Art.-no.
1FS5
Art.-no.
32-0011
32-5016
32-0016
32-0021
32-5021
32-5026
32-0026
32-5031
32-0031
32-5035
32-0035
32-0037
32-0039
32-0041
32-5037
32-5039
32-5041
Primary
current
[A]
Order list KBR 44
Secondary current
Primary
current
[A]
250
300
400
500
600
750
800
1000
Burden
[ VA ]
1.5
2.5
2.5
5
5
5
5
5
5
5A
1A
Accuracy class
Accuracy class
1FS5
Art.-no.
44-5001
1FS5
Art.-no.
44-5006
44-5011
44-5016
44-5021
44-5026
44-5031
44-5036
44-0001
44-0006
44-0011
44-0016
44-0021
44-0026
44-0031
44-0036
Primary
current
[A]
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
Page 7
MBS AG
You haven’t found the right split-core current transformer?
You are looking for a split-core current transformer…
…with a better accuracy class, f.e. class 0.2 ?
…as a protection CT, f.e. in protection class 5P20 ?
…with several measuring systems in only one device ?
…or a split-core CT with a bigger opening for your primary conductor ?
Then our fully resin-hardened split-core current transformer type CTO is
exactly the right decision!
Features / benefits
- Split-core current transformer suitable for measuring or protection purposes,
depending on the design of the CT
- The modular design of this series allows a large number of varieties within the
different CT sizes (f.e. two cores in one unit); please see next page for details
about the different dimensions
- Max. operating voltage: 0.72/3/- kV or 1.2/6/- kV; if the primary conductor is
suitably insulated the CT can also be used above 0.72 kV or 1.2 kV
- Primary current range: 50 A … 5000 A
- Secondary currents: 1 A, 2 A or 5 A
- Rated burden: 2.5 VA … 30 VA
- Accuracy classes: 0.2S; 0.2; 0.5S; 0.5; 1; 3
- Over-current rated limiting factor for measuring cores: FS5 or FS10
- Protection classes: 5P / 10P / PX
- Over-current rated limiting factor for protection cores: 5, 10, 15, 20, 30
Dimensions
Inner diameter:
max. 360 mm
Transformer width: 150 – 500 mm
Transformer depth: 60 – 300 mm
Please see next page for details
about the different dimensions.
General technical specifications
- Operating temperature: -5°C < T < +40°C
- Storage temperature:
-25°C < T < +70°C
- Therm. nominal continuous current Icth: 1.0 x IN or 1.2 x IN, other values upon request
- Therm. nominal short-time current Ith: Min. 100 x IN, 1 sec., other values upon request
- Isolation test voltage:
3 kV, Ueff, 50 Hz, 1 min. or
6 kV, Ueff, 50 Hz, 1 min.
- Rated frequency: 50 Hz or 60 Hz, other values upon request
- Isolation class:
E
- Applicable technical standard: DIN EN 61869, part 1 + 2
Further information
- Measuring systems fully hardened with Polyurethane resin
- The current transformers type CTO are intended for subsequent installation in existing low-voltage switchgear. In addition, there are
customers who use these current transformers in medium-voltage switchgears, if the primary conductor is suitably insulated.
- The two parts of the current transformer are held together by four screws with springs or spring clips on the sides, which ensures a
permanent contact pressure.
- The secondary connection terminals are factory-fitted with M5 screws. A clear plastic cover serves as an touch protection.
- Protection type: Housing: IP54, Terminal cover: IP20
- Mounting of CT by means of a baseboard attached to the resin body
- Packaging unit: 1 Stk.
- Customs tariff number: 85043129
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Page 8
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
MBS AG
Dimension drawings
Frame size
x*
y*
A
B
C
D
E
F
G
60
90
120
150
200
250
300
25
55
85
115
165
215
265
* Dimension x + y depends on the type and number
of measuring systems installed.
Determination of current transformer type
Example:
CTO 200
B
130
Inner diameter (d1: 130 mm)
Frame size (B: 90 mm)
CT type: CTO 200
CT type
b1
b2
b3
max. d1
d2
h1
h2
h3
max. frame size
Deliverable
CTO 135
CTO 150
CTO 170
CTO 200
CTO 250
CTO 300
CTO 350
CTO 400
CTO 500
135
150
170
200
250
300
350
400
500
150
150
170
200
250
300
350
400
500
130
130
150
180
230
280
330
370
440
90
110
110
140
150
210
250
300
360
9
9
11
11
11
11
11
13
13
150
165
185
220
270
330
380
430
530
75
82,5
97,5
110
135
165
190
215
265
10
10
10
10
10
10
10
15
15
C
D
D
E
E
F
F
G
G
Upon request
Upon request
Yes
Yes
Yes
Yes
Upon request
Upon request
Upon request
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
Page 9
MBS AG
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Page 10
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
MBS AG
Notes
MBS AG
Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen
Germany
Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90
E-Mail: [email protected] ∙ Web: www.mbs-ag.com
Page 11
Current transformers for industry
Current transformers for tariff
Accessories for current transformers
Medium-voltage CTs
Bus bar insulators / -supports
Shunts
Voltage transformers
All current sensors
Measuring transducers
Energy meters with or without
MID approval
Accessories for energy meters
Panel board heaters, filter fans, roof
MBS AG
Eisbachstraße 51 • 74429 Sulzbach-Laufen • Germany
Telefon: +49 7976 9851-0 • Telefax: +49 7976 9851-90
[email protected] • www.mbs-ag.com
www.mbs-ag.com
MBS IDNR 8.4.0372/1000/03-2014
fans and control units