Split-core current transformers We make energy measurable and take care of your future www.mbs-ag.com MBS AG MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Page 2 Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com MBS AG Split-core current transformer, type KBU Features / benefits - Perfect for subsequent assembly into already existing installations Easy and safe mounting, due to hearable locking system Deliverable with secondary current 5 A / 1 A Deliverable also in accuracy class 0.5 Four different construction types General technical specifications - Operating temperature: -5°C < T < +40°C - Storage temperature: -25°C < T < +70°C - Therm. nominal continuous rated current Icth: 1.0 x IN - Therm. nominal short-time current Ith: 60 x IN, 1 sec. - Max. operating voltage Um: 0.72 kV - Isolation test voltage: 3 kV, Ueff, 50 Hz, 1 min. - Rated frequency: 50 Hz - Isolation class: E - Applicable technical standard: DIN EN 61869, part 1 + 2 Dimensions Type KBU 23 KBU 58 KBU 812 KBU 816 A (width) [ mm ] 93 125 155 195 B (height) [ mm ] 106 158 198 243 C / C1 (depth) [ mm ] 34 / 58 34 / 58 34 / 58 64 / 79 D [ mm ] E [ mm ] F [ mm ] G [ mm ] 23 55 85 85 33 85 125 165 64 96 126 156 56 56 56 62 MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com Page 3 MBS AG Order list KBU 23 5A 1A Accuracy class Accuracy class Secondary current Primary current [A] 100 150 200 250 300 400 Burden [ VA ] 1.25 1.5 2.5 1.5 3.75 1 5 3 Art.-no. 80048 80030 80031 0.5 Art.-no. 1 Art.-no. 3 Art.-no. 80248 80230 80231 1 Art.-no. 80044 80045 0.5 80244 80245 80037 80237 80046 80246 5A 1A Accuracy class Accuracy class Order list KBU 58 Secondary current Primary current [A] 250 300 400 500 600 750 800 1000 Burden [ VA ] 1.5 2.5 1 2.5 2.5 5 2.5 5 2.5 5 2.5 7.5 5 10 1 Art.-no. 80061 80062 0.5 Art.-no. 1 Art.-no. 80261 80262 80038 80063 80238 80263 80054 80064 80254 80264 80055 80065 80255 80265 80056 80066 80256 80266 80057 80067 80257 80267 80058 80068 0.5 Art.-no. 80258 80268 MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Page 4 Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com MBS AG Order list KBU 812 5A 1A Accuracy class Accuracy class Secondary current Primary current [A] 250 300 400 500 600 750 800 1000 1200 1250 1500 Burden [ VA ] 1.5 2.5 2.5 2.5 5 2.5 5 2.5 2 2.5 7.5 5 10 5 10 7.5 15 7.5 15 1 Art.-no. 80091 80092 80093 0.5 Art.-no. 1 Art.-no. 80291 80292 80293 0.5 Art.-no. 80074 80094 80274 80294 80075 80095 80275 80295 80076 80096 80276 80296 80077 80097 80277 80297 80078 80098 80278 80298 80079 80099 80279 80299 80080 80100 80280 80300 80081 80101 80281 80301 Order list KBU 816 5A 1A Accuracy class Accuracy class Secondary current Primary current [A] 1000 1200 1500 1600 2000 2500 3000 4000 5000 Burden [ VA ] 10 15 10 15 10 15 10 15 10 15 10 15 15 30 15 30 15 30 1 Art.-no. 80140 80141 80142 80143 80144 80145 80146 80147 80148 80149 80150 80151 80152 80153 80154 80155 80156 80157 0.5 Art.-no. 80110 80111 80112 80113 80114 80115 80116 80117 80119 80120 80122 80123 80124 80125 80126 1 Art.-no. 80340 80341 80342 80343 80344 80345 80346 80347 80348 80349 80350 80351 80352 80353 80354 80355 80356 80357 0.5 Art.-no. 80310 80311 80312 80313 80314 80315 80316 80317 80319 80320 80322 80323 80324 80325 80326 MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com Page 5 MBS AG Split-core current transformer, type KBR Features / benefits - Perfect for subsequent assembly into already existing installations - Due to the „click“-system even a one-hand mounting is possible - Deliverable with secondary 5 A / 1 A or as a current sensor (0…333 mV) or measuring transducer (4…20 mA DC). - Three different construction types General technical specifications - Length of connection cable: Sec. 1A: Sec. 5A: 0…333 mV: 4…20 mA: - 2.5 m, cross section 2x0.75 mm² 0.5 m, cross section 2x1.5 mm² 2.5 m, cross section 2x0.75 mm² 2.5 m, cross section 2x0.75 mm² (Other lengths are possible on request) Operating temperature: -5°C < T < +50°C Storage temperature: -25°C < T < +70°C Therm. nominal continuous rated current Icth: 1.2 x IN Therm. nominal short-time current Ith: 60 x IN, 1 sec. Max. operating voltage Um: 0.72 kV Isolation test voltage: 3 kV, Ueff, 50 Hz, 1 min. Rated frequency: 50 Hz Isolation class: E Applicable technical standard: DIN EN 61869, part 1 + 2 Dimensions Type A (width) [ mm ] B (height) [ mm ] C / C1 (depth) [ mm ] D (diameter) [ mm ] KBR 18 KBR 32 KBR 44 41.6 59.2 72.2 64.5 96.4 120.6 55 / 67.3 75 / 89.2 85 / 98.1 18.5 32.5 44 Technical characteristics for the KBR with output signal 4…20 mA: - 2-wire connection, auxiliary power via output circuit - Auxiliary power: 24 V DC ± 15 %, PV = max. 1 VA - Load-independent DC current: Live-zero, 4…20 mA - External resistance: max. 300 Ω - Current limit under overload: < 30 mA - Residual ripple of the output current: ≤ 1 % p.p. - Response time: < 300 ms Wiring diagram of the KBR 44 (4…20 mA): MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Page 6 Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com MBS AG Order list KBR 18 5A 1A Accuracy class Accuracy class Secondary current Primary current [A] 50 75 100 125 150 200 250 Burden [ VA ] 3FS5 Art.-no. 1FS5 Art.-no. 1 1 1.25 1.5 2 1 3 1.5 4 3FS5 Art.-no. 18-0001 18-0006 18-0011 18-0016 18-0021 0…333 mV AC 4…20 mA DC Accuracy class Accuracy class 1 Art.-no. 50 75 100 125 150 1 Art.-no. 18-1001 18-1006 18-1011 18-1016 18-1021 200 181026 250 18-1031 Output 0…333 mV AC 4…20 mA DC Accuracy class Accuracy class 1 Art.-no. 1 Art.-no. 100 32-1011 32-2011 125 32-1016 32-2016 150 32-1021 32-2021 200 32-1026 32-2026 250 32-1031 32-2031 300 32-1034 32-2034 400 500 600 32-1036 32-1038 32-1040 32-2036 32-2038 32-2040 Output 0…333 mV AC 4…20 mA DC Accuracy class Accuracy class 1 Art.-no. 1 Art.-no. 250 44-1001 44-2001 300 400 500 600 750 800 1000 44-1006 44-1011 44-1016 44-1021 44-1026 44-1031 44-1036 44-2006 44-2011 44-2016 44-2021 44-2026 44-2031 44-2036 Output 1FS5 Art.-no. 18-0027 18-0026 18-0032 18-0031 Primary current [A] Order list KBR 32 5A 1A Accuracy class Accuracy class Secondary current Primary current [A] 100 125 150 200 250 300 400 500 600 Burden [ VA ] 1.5 2.5 2.5 3 3 3 5 3 5 2.5 5 5 5 5 3FS5 Art.-no. 32-5011 1FS5 Art.-no. 3FS5 Art.-no. 1FS5 Art.-no. 32-0011 32-5016 32-0016 32-0021 32-5021 32-5026 32-0026 32-5031 32-0031 32-5035 32-0035 32-0037 32-0039 32-0041 32-5037 32-5039 32-5041 Primary current [A] Order list KBR 44 Secondary current Primary current [A] 250 300 400 500 600 750 800 1000 Burden [ VA ] 1.5 2.5 2.5 5 5 5 5 5 5 5A 1A Accuracy class Accuracy class 1FS5 Art.-no. 44-5001 1FS5 Art.-no. 44-5006 44-5011 44-5016 44-5021 44-5026 44-5031 44-5036 44-0001 44-0006 44-0011 44-0016 44-0021 44-0026 44-0031 44-0036 Primary current [A] MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com Page 7 MBS AG You haven’t found the right split-core current transformer? You are looking for a split-core current transformer… …with a better accuracy class, f.e. class 0.2 ? …as a protection CT, f.e. in protection class 5P20 ? …with several measuring systems in only one device ? …or a split-core CT with a bigger opening for your primary conductor ? Then our fully resin-hardened split-core current transformer type CTO is exactly the right decision! Features / benefits - Split-core current transformer suitable for measuring or protection purposes, depending on the design of the CT - The modular design of this series allows a large number of varieties within the different CT sizes (f.e. two cores in one unit); please see next page for details about the different dimensions - Max. operating voltage: 0.72/3/- kV or 1.2/6/- kV; if the primary conductor is suitably insulated the CT can also be used above 0.72 kV or 1.2 kV - Primary current range: 50 A … 5000 A - Secondary currents: 1 A, 2 A or 5 A - Rated burden: 2.5 VA … 30 VA - Accuracy classes: 0.2S; 0.2; 0.5S; 0.5; 1; 3 - Over-current rated limiting factor for measuring cores: FS5 or FS10 - Protection classes: 5P / 10P / PX - Over-current rated limiting factor for protection cores: 5, 10, 15, 20, 30 Dimensions Inner diameter: max. 360 mm Transformer width: 150 – 500 mm Transformer depth: 60 – 300 mm Please see next page for details about the different dimensions. General technical specifications - Operating temperature: -5°C < T < +40°C - Storage temperature: -25°C < T < +70°C - Therm. nominal continuous current Icth: 1.0 x IN or 1.2 x IN, other values upon request - Therm. nominal short-time current Ith: Min. 100 x IN, 1 sec., other values upon request - Isolation test voltage: 3 kV, Ueff, 50 Hz, 1 min. or 6 kV, Ueff, 50 Hz, 1 min. - Rated frequency: 50 Hz or 60 Hz, other values upon request - Isolation class: E - Applicable technical standard: DIN EN 61869, part 1 + 2 Further information - Measuring systems fully hardened with Polyurethane resin - The current transformers type CTO are intended for subsequent installation in existing low-voltage switchgear. In addition, there are customers who use these current transformers in medium-voltage switchgears, if the primary conductor is suitably insulated. - The two parts of the current transformer are held together by four screws with springs or spring clips on the sides, which ensures a permanent contact pressure. - The secondary connection terminals are factory-fitted with M5 screws. A clear plastic cover serves as an touch protection. - Protection type: Housing: IP54, Terminal cover: IP20 - Mounting of CT by means of a baseboard attached to the resin body - Packaging unit: 1 Stk. - Customs tariff number: 85043129 MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Page 8 Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com MBS AG Dimension drawings Frame size x* y* A B C D E F G 60 90 120 150 200 250 300 25 55 85 115 165 215 265 * Dimension x + y depends on the type and number of measuring systems installed. Determination of current transformer type Example: CTO 200 B 130 Inner diameter (d1: 130 mm) Frame size (B: 90 mm) CT type: CTO 200 CT type b1 b2 b3 max. d1 d2 h1 h2 h3 max. frame size Deliverable CTO 135 CTO 150 CTO 170 CTO 200 CTO 250 CTO 300 CTO 350 CTO 400 CTO 500 135 150 170 200 250 300 350 400 500 150 150 170 200 250 300 350 400 500 130 130 150 180 230 280 330 370 440 90 110 110 140 150 210 250 300 360 9 9 11 11 11 11 11 13 13 150 165 185 220 270 330 380 430 530 75 82,5 97,5 110 135 165 190 215 265 10 10 10 10 10 10 10 15 15 C D D E E F F G G Upon request Upon request Yes Yes Yes Yes Upon request Upon request Upon request MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com Page 9 MBS AG MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Page 10 Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com MBS AG Notes MBS AG Eisbachstraße 51 ∙ 74429 Sulzbach-Laufen Germany Telefon: +49 7976 9851-0 ∙ Telefax: +49 7976 9851-90 E-Mail: [email protected] ∙ Web: www.mbs-ag.com Page 11 Current transformers for industry Current transformers for tariff Accessories for current transformers Medium-voltage CTs Bus bar insulators / -supports Shunts Voltage transformers All current sensors Measuring transducers Energy meters with or without MID approval Accessories for energy meters Panel board heaters, filter fans, roof MBS AG Eisbachstraße 51 • 74429 Sulzbach-Laufen • Germany Telefon: +49 7976 9851-0 • Telefax: +49 7976 9851-90 [email protected] • www.mbs-ag.com www.mbs-ag.com MBS IDNR 8.4.0372/1000/03-2014 fans and control units
© Copyright 2024 ExpyDoc