MJB 250 MA4 - German Generator GmbH

THREE PHASE SYNCRONOUS GENERATOR
MJB 250 MA4
4 poles
50 Hz - 1500 rpm / 60 Hz - 1800 rpm
CONTINUOUS DUTY
AMBIENT TEMPERATURE 40°C
TEMPERATURE RISE
H
INSULATION CLASS
H
POWER FACTOR 0,8
FREQUENCY
VOLTAGE
Hz
Connections
Star series
Star parallel
RATING POWER
EFFICIENCY [%] @ 0,8 p.f.
EFFICIENCY [%] @ 1 p.f.
SHORT CIRCUIT RATIO
REACTANCES [%]
Direct axis synchronous
Quadrature axis synchronous
Direct axis transient
Direct axis subtransient
Quadrature axis subtransient
Negative sequence
Zero sequence
TIME CONSTANTS [s]
Open circuit
Transient
Subtransient
Armature
Winding code M0
Number of leads 12
Winding pitch 2/3
WINDING DATA
kVA
kW
4/4
3/4
2/4
4/4
3/4
2/4
SCR
380
190
165
132
92,5
93,0
93,2
94,0
94,4
94,6
0,42
50 Hz
400 415
200 208
165 165
132 132
92,9 92,8
93,2 93,1
93,1 93,0
94,4 94,3
94,6 94,5
94,5 94,5
0,47 0,51
440
220
165
132
92,7
93,0
92,8
94,2
94,5
94,3
0,57
380
190
170
136
91,7
92,7
93,1
93,4
94,2
94,5
0,34
416
208
175
140
92,2
93,1
93,2
93,8
94,5
94,6
0,40
60 Hz
440
220
185
148
92,4
93,1
93,3
94,0
94,6
94,7
0,42
460
230
195
156
92,6
93,3
93,4
94,1
94,7
94,8
0,44
480
240
205
164
93,6
93,8
93,4
94,9
95,1
94,8
0,45
Xd
Xq
X'd
X''d
X''q
X2
X0
361
201
31,7
13,3
15,3
14,3
3,0
326
181
28,6
12,0
13,8
12,9
2,8
269
150
23,6
9,9
11,4
10,7
2,3
338
248
39,2
16,4
18,9
17,7
3,8
384
213
33,7
14,1
16,2
15,2
3,2
362
201
31,8
13,3
15,3
14,3
3,1
350
194
30,7
12,9
14,8
13,8
2,9
338
187
29,6
12,4
14,3
13,4
2,8
V
T'do
T'd
T"d
Ta
303
168
26,6
11,1
12,8
12,0
2,6
0,95
0,09
0,011
0,012
MECHANICAL CHARACTERISTICS
D-end bearing/Lubrication
N-end bearing/Lubrication
Overspeed [r.p.m.]
Inertia (J) [kgm2]
Refer to B34 construction
Weight [kg]
Refer to B34 construction
Method of cooling
Cooling air required [m3/s] @ 50/60 Hz
Degree of protection
Types of construction available
Direction of rotation (Standard)
6218 2RS C3 / Prelubricated
6313 2Z C3 / Prelubricated
2250
1,41
530
IC01
0,42 / 0,52
IP23
B2 (SAE) - IM B34
CW
OTHER DATA
Phase resistance
@ 20 °C - Star series
Overloads
3-phase short circuit sustained current
Voltage regulation accuracy
Radio interference
Wave form THF
Total harmonic content
0,032
10% for 1 hour every 12 hours
≥ 300 % (3 In) with auxiliary winding
± 0,5 % In steady state condition
EN 55011 - Class B Group 1
< 2%
< 2% - At no load
STANDARDS
IEC 60034-1; CEI 2-3; BS 4999-5000; VDE 0530; NF 51-100,111; OVE M-10, NEMA MG 1.22.
SIN.DT.014.6
Data and Technical Specification are subject to change in order to update or improve the products, without prior notice
THREE PHASE SYNCRONOUS GENERATOR
MJB 250 MA4
Typical efficiency curves
50 Hz - 1500 rpm
380 V
Efficiency [%]
96
pf 1
94
pf 0,8
92
90
0%
25%
50%
75%
100%
125%
Load [%]
400 V
Efficiency [%]
96
pf 1
94
pf 0,8
92
90
0%
25%
50%
75%
100%
125%
Load [%]
415 V
Efficiency [%]
96
pf 1
94
pf 0,8
92
90
88
0%
25%
50%
75%
100%
125%
Load [%]
440 V
Efficiency [%]
96
pf 1
94
pf 0,8
92
90
88
0%
25%
50%
75%
100%
Load [%]
Typical efficiency curves
SIN.DT.014.6
60 Hz - 1800 rpm
Data and Technical Specification are subject to change in order to update or improve the products, without prior notice
125%
THREE PHASE SYNCRONOUS GENERATOR
MJB 250 MA4
Typical efficiency curves
60 Hz - 1800 rpm
380 V
Efficiency [%]
96
94
pf 1
92
90
0%
pf 0,8
25%
50%
75%
100%
125%
Load [%]
416 V
Efficiency [%]
96
94
pf 1
92
pf 0,8
90
0%
25%
50%
75%
100%
125%
Load [%]
440 V
Efficiency [%]
96
94
pf 1
pf 0,8
92
90
0%
25%
50%
75%
100%
125%
Load [%]
460 V
Efficiency [%]
96
pf 1
94
pf 0,8
92
90
0%
25%
50%
75%
100%
125%
Load [%]
480 V
Efficiency [%]
96
pf 1
94
pf 0,8
92
90
0%
25%
50%
75%
100%
Load [%]
SIN.DT.014.6
Data and Technical Specification are subject to change in order to update or improve the products, without prior notice
125%
THREE PHASE SYNCRONOUS GENERATOR
MJB 250 MA4
Locked rotor motor starting curves (*)
50 Hz - 1500 rpm
380 V
400 V
415 V
440 V
50
45
Voltage Dip [%]
40
35
30
25
20
15
10
5
0
0
50
100
150
200
250
300
350
400
450
400
450
60 Hz - 1800 rpm
380 V
416 V
440 V
460 V
480 V
60
Voltage Dip [%]
50
40
30
20
10
0
0
50
100
150
200
250
300
350
(*): A coefficient of 0,85 must be applied to the voltage dip if the load has a power factor equal or greater than 0,8.
SIN.DT.014.6
Data and Technical Specification are subject to change in order to update or improve the products, without prior notice