SECURA KEY CARD ACCESS CONFIGURATION GUIDE Single/Multi-Reader Systems with SK-ACPE Two-Door Panel MULTI-PANEL SYSTEM USING SK-NETTM SOFTWARE- SINGLE LOCATION WITH LAN CONNECTION NOTE: In this example, only the first panel is connected to the LAN. Additional panels are daisy-chained from the first panel using RS-485 over twisted pair. SK-NET-MLD software must be used when connecting more than one SK-ACPE to the LAN. This diagram can also be a remote location connected over a WAN, if a static IP address is used at each remote site. ¿ 3 SK-ACPE 3 SK-ACPE SK-ACPE SK-ACPE 1 SK-ACPE 1 STAR / FANOUT DAISY CHAIN / MULTIDROP 3 “T” CONFIG ¿ ¿ NETWORK 1 SK-ACPE SK-ACPE SK-ACPE RS-485 NETWORK CABLE: SK-ACPE RS-485 communications. Suggested cable: CAT 5 network cable or Two Twisted Pair. Total system cable length: 4,000 ft. SK-ACPE STUBBED SK-ACPE ETHERNET CABLE: Standard Ethernet cable connector connected to existing LAN. NOTE: Each SK-ACPE above can support 2 Wiegand output card readers. SK-ACPE SYSTEM USING SK-NET-MLD SOFTWARE WITH MULTIPLE LAN CONNECTIONS ROUTER/SWITCH 3 HUB 3 WIRED/WIRELESS ROUTER 3 3 SK-ACPE 3 SK-ACPE SK-ACPE ETHERNET CABLE: (Required cables CAT 5e or CAT 6). Wired: max distance 300’ (100m) between devices. Wireless: Typically 100-200’ (30-60m) depending on interference, building structure and metal objects. NOTE: Each SK-ACPE above can support 2 Wiegand Output Card Readers. SK-ACPE WITH OPTIONAL SK-WLSE MOD* MULTI LOCATION SYSTEM WITH SK-NET-MLD SOFTWARE 1 ¿ SK-ACPE RS-232 GATEWAY 1 USB USB SK-USB SK-USB SK-ACPE ¿ MODEM NET-CONV-P 2 TELCO LINE SK-ACPE SK-ACPE SK-ACPE SK-MDM SK-ACPE 1 Up to 100 SK-ACPE’s A virtually unlimited number of remote locations can be set-up on one PC with SK-NET-MLD Software. Up to 100 SK-ACPE’s RS-485 Network Wiring Connections SK-ACPE NOVA.16 J8 J2 Line A (2) ¿ Line B (1) DC SIGNAL GROUND (3) (REQUIRED) ¿ Earth Grounded Shield is highly recommended in environments to high Earthsubject Grounded Shield voltage is highlyelectrical recommended in environments subject to discharge (i.e. lightning). Shield high voltage electrical discharge (i.e. should lightning). Shield be shouldconnected be connected toto earth earthground ground only at one the cable. only at end oneofend of the cable. DC Signal ground is required. DC DC Signal ground is required. DC Ground wire is NOT to be connected to earthGround ground. wire is NOT to be connected to earth ground. MULTI-PANEL SYSTEM USING SK-NETTM SOFTWARE- SINGLE LOCATION with RS-485 CONVERTER NOTE: Use this configuration when the PC is located more than 100’ from the first SK-ACPE, and a LAN connection is not available. NET-CONV-P RS232-RS485 CONVERTER PLUG INTO SK-USB USB SK-USB ¿ 1 RS-485 NETWORK CABLE: 2 SERIAL CABLE: 1 UP TO 4000 Ft. RS-485 communications. Suggested cable: CAT 5 network cable or Two Twisted Pair. Total system cable length: 4,000 ft. RS-232 communications. Suggested cable: 6-Conductor, Shielded, with no twisted pairs. Total cable length 100 feet. 1 SK-ACPE SK-ACPE SK-ACPE SK-ACPE NOTE: When using the RS-232 to RS-485 converter, you cannot use the stubbed, star fanout or “T” configuration. All network connections from SK-ACPE to the next SK-ACPE must be in parallel with each other. The J8 connector, Pins 1 and 2 must be a twisted pair. Pin 3 (Ground) can use 1 conductor of a second pair. SK-ACPE PANEL SYSTEM USING SK-NETTM SOFTWARE WITH RS-232 GATEWAY CONNECTED DIRECTLY TO A PC UP TO 500 Ft. 4 RS-232 GATEWAY USB DB9 ¿ SK-USB SK-PLUG9 2 CARD READER WITH ANY C A R D T E C H N O L O G Y, WIEGAND OUTPUT, 26 BITS RS-232 UP TO 100 Ft. SK-ACPE SK-ACPE PANEL SYSTEM USING SK-NETTM SOFTWARE WITH RS-232 TO RS-485 CONVERTER (NET-CONV-P) UP TO 500 Ft. NET-CONV-P RS232-RS485 CONVERTER PLUG INTO SK-USB 4 1 ¿ RS-485 UP TO 4000 Ft. SK-USB CARD READER WITH ANY C A R D T E C H N O L O G Y, WIEGAND OUTPUT, 26 BITS SK-ACPE ¿ MULTI-PANEL SYSTEM USING SK-NETTM SOFTWARE- SINGLE LOCATION RS-232 CONNECTION DAISY CHAIN / MULTIDROP ¿ SK-USB DB9 SK-PLUG9 2 UP TO 100 Ft. SK-ACPE SK-ACPE 1 SK-ACPE SK-ACPE SK-ACPE ¿ USB “T” CONFIG STAR / FANOUT SK-ACPE SK-ACPE SK-ACPE SK-ACPE SK-ACPE STUBBED SK-ACPE NOTE: Each SK-ACPE above can support 2 Wiegand output card readers. 1 RS-45 NETWORK CABLE: 2 SERIAL CABLE: 4 WIEGAND CABLE: RS-485 communications. Suggested cable: CAT 5 network cable or Two Twisted Pair. Total system cable length: 4,000 ft. For RS-232 communications interface. Suggested cable: 6-Conductor, Shielded, with no twisted pairs. Total cable length 100 feet. SK-USB required if your PC does not have a COM port Suggested cable: 6-Conductor, Shielded, with no twisted pairs. Total cable length 500 feet. 1 SYSTEM equipment components ACCESS CONTROL UNIT: SK-ACPE: Two Door Access Control Unit Radio Key® Low Frequency Proximity READERS: RK-WM: Proximity Reader (2 readers per SK-ACPE), Mullion RK-WS: Proximity Reader (2 readers per SK-ACPE), Switchplate RK-WL: Proximity Reader (2 readers per SK-ACPE), Long Range CARDS/TAGS: RKCM-02-2 RKKT-02-2 RKCI-02-2 Molded Proximity Cards - 26/32 bit encoding Key Tags - 26/32 bit encoding ISO Proximity Cards - 26/32 bit encoding E*Tag® High Frequency Proximity: READERS: ET4-WXM: 13.56 MHz ISO 15693, Mullion ET4-WXS: 13.56 MHz ISO 15693, Switchplate ET8-RO-W-D: 13.56 MHz ISO 15693, Switchplate ET8-RO-W-M: 13.56 MHz ISO 15693, Mullion CARDS/TAGS: ETCI04-1- ISO Card- 26/32 bit encoding ETCI04-4- ISO Card- 26/32 bit encoding, Mag-Stripe ETST03-1-Key Tag Trapezoidal - 26/32 bit encoding ETKT03-1 Key Tag, Rounded End, 26/32 bit encoding PC REQUIREMENTS: See Table MINIMUM REQUIREMENTS* OPERATING SYSTEM PROCESSOR SPEED RAM AVAILABLE DISK SPACE WINDOWS® XP OR NEWER 1 GHz 1 GB 1 GB * For larger installation more disk space may be required. RECOMMENDED SYSTEM WINDOWS® XP OR NEWER 2 GHz 2 GB 10 GB * For larger installation more disk space may be required. SERVER REQUIREMENT (FOR CLIENT/SERVER VERSIONS)** WINDOWS® 2003 OR NEWER 2 GHz 1 GB 1 GB ** For SK-NET-MLD-C/S version, a server is required to install ADS and the database. SK-NET™ must be installed on a workstation only. Required Peripherals: RS-232 COM Port, USB Port or TCP/IP, a modem if you use dial-up and a printer for reports. SOFTWARE: SK-NET™- DM - Basic Software - USB Flash Drive and manual SK-NET™ -MLD - Multi-Location Software with USB Flash Drive and manual SK-NET-MLD - CSXX (XX= 2,5,10 or 15 workstations), USB Flash Drive & Manual with Client Server License ACCESSORIES: NET-CONV-P - RS-232 to RS-485 Converter with Power Supply (plug into SK-USB) RS-232E - Connects J11 MTA connector to DB9 SK-24VDC - DC power supply, provides 1A@24VDC. SK-MDM - Modem - 56K Baud External Modem for dial-up connection to any SK-ACPE with MLD software SK-ACP-PS - 1A, 24VDC 4.0 AH supply and stand by battery for SK-ACPE. SK-BAT - 4.0 AH standby battery for SK-ACPE. SK-PLUG9 - Computer connector (DB9) with wire pigtail. SK-USB - Converts USB Port at PC to serial COM Port with DB9 connector SK-WLSE-MOD* - Wireless LAN adapter, 802.11 b/g. Powered by SK-ACPE. Connect at J12 and set jumpers. SK-XFRMR - 16.5VAC 40VA Transformer for SK-ACPE. * Contact Factory for Availability. SECURA KEY sk-acpE Typical Door Installation 2 2 INPUT 1-2 INPUT 2-1 2 INPUT 2-2 3 INPUT 1-1 DOOR MONITOR READER INPUT 2 1 RELAY 2-1 2 REMOTE DOOROPEN SWITCH } TO 2ND DOOR READER INPUT 1 TO PC HOST. 3 ¿ 3 L A T C H BATTERY BACK-UP ¿ 1 1 1 ELECTRIC STRIKE or MAG LOCK RS-485 TO ADDITIONAL PANELS 4 SK-ACPE RK-WM 5 4 POWER 1 XFMR or POWER SUPPLY PANEL POWER SUPPLY POWER STRIKE OR MAGLOCK SUPPLY CABLE TYPES: 8060 1 2 COND, UNSHIELDED 16-18 AWG 2 2 COND, SHIELDED 18-24 AWG 3 6 COND, SHIELDED, NO TWISTED PAIRS 18-24 AWG WIEGAND OR RS-232 4 RS-485 - CAT 5 Network cable OR TWO Twisted Pair 5 TCP/IP - CAT 5e or CAT 6 ETHERNET CABLE 20301 NORDHOFF STREET CHATSWORTH, CA 91311 PHONE (818) 882-0020 • FAX (818) 882-7052 TOLL FREE (800) 891-0020 [email protected] • www.securakey.com
© Copyright 2024 ExpyDoc