Flint Creek Power Plant

Flint Creek Power Plant - Water Flow Diagram
Flint Creek
Sanitary Sewage
Gentry Sewage
Treatment
Plant
Dike Seepage
& Pump Back
City of Gentry
Sewage Treatment
Plant Effluent
(ARR0020184)
Demineralizer
Sump
Boiler
Blowdown
Storm Water
Runoff
Demineralizer
Process Wastes
Lab Drains
 South portion of plant
 Coal pile runoff
 Non-industrial upgradient runoff - 1,127 acres
Bottom Ash Sump
Condenser Sump
~0.63 MGD
Landfill
Landfill
Leachate
0.072 MDG max
Bioreactor
Treatment System
Secondary
Settling
Basin
(3.7 acres)
0.036 MGD max
Weir and pH
Neutralization
Basin
Landfill Truck Wash
Station
15,000 gal
capacity
CO2 Injection
(pH control)
Arkansas
River
Stack Seal
Water Overflow
Coal Pile Reclaim
Hopper & Rail Car
Dumper Sumps
Outfall 101
47.8 MGD max
Coal Handling
Equipment
Washwater
Bottom Ash &
Economizer Ash
Sluice Water
0.72 MGD max
Illinois River
Outfall 001
2.0 cfs min
Flint Creek
Little Flint
Creek
Water
Recovery
Pond
Washwater & Storm Water from
Waste Silos, NID, & ACI Areas
SWEPCO
Lake
(530 acres)
Industrial Storm
Water
Runoff
(north side of
plant - S001)
Note 1* - Total wastewater and stormwater flow from plant processes into
the Primary Settling Basin is 128 MDG maximum
Transformer Secondary Containment
Drains (uncontaminated storm water)
Equipment
Coolers in
Turbine Building
Hydrogen
Coolers
Reclaim
Water
Storage Basin
High
Pressure
Svc Water
NID Service
Water Tank
NID Oil-Containing Equip. Washwater,
Stormwater and Condensate
NID Nozzle Cleaning Waste
Lake
Tenkiller
Plant Floor
Drains
Turbine Building Roof Drains
Daily Slab and Equipment Washwater
Air Heater Washwater (non-chemical MCW)
Heat Exchanger Washwater (non-chemical MCW)
Ash
Sluice
Pump
Hydrovactor
Water
NID Oil/Water
Separator
Pump
Back
Condenser Washwater
(non-chemical MCW)
Pulverizer Lube Oil Coolers
~1.5 MDG
Main Lift Sump
36.25 MGD
Ash Landfill Leachate
Collection Pond
Ecology
Pit
Note 1*
Ash Landfill Contact Storm
Water Pond
Landfill Contact
Storm Water
Precipitation
FD Fan Bearing Oil Coolers
Primary
Settling
Basin
(42.8 acres)
Landfill
Non-Contact
Storm Water
Demineralizer
System
Demin
Water Tanks
Boiler
Pin Mixer Make-up at
Byproduct Silo
(mixed with waste
and hauled to landfill)
Turbine Oil
Coolers
Generator &
Alterex Coolers
Surge Tank
Outfall 401
~406 MGD max
Surge Tank Overflow
Cooling Water
Intake Structure
Traveling Screen
Washwater
Main
Condenser
Auxiliary
Condenser
Service
Water
Boiler Water
Lances & Water
Cannons
Low
Pressure
Svc Water
ClNaO
Injection
(biocide)