NCS FC82012A-17A

Certificate of Certified Reference Material
NCS FC 82012a — NCS FC 82017a
Coal Ash
Issued in 2014
Approved by China National Analysis Center for Iron and Steel
( Beijing China )
Certified Values and Uncertainty
No.
SiO2
K2O
Na2O
P2O5
NCS FC
Certified Value
46.99 29.45 7.95 8.73 1.03 0.69
1.28
1.16
82012a
Uncertainty
0.21 0.21 0.09 0.27 0.06 0.04
0.03
0.04
NCS FC
Certified Value
41.11 28.54 13.43 5.30 0.71 5.10
2.62
1.61
82013a
Uncertainty
0.21 0.12 0.22 0.08 0.07 0.15
0.05
0.06
NCS FC
Certified Value
54.68 28.09 6.04 5.15 1.05 0.49
1.14
1.44
82014a
Uncertainty
0.21 0.11 0.09 0.09 0.09 0.04
0.03
0.06
NCS FC
Certified Value
59.66 22.90 6.55 4.01 1.31 0.40
1.13
1.53
82015a
Uncertainty
0.24 0.10 0.07 0.08 0.10 0.04
0.03
0.07
NCS FC
Certified Value
51.24 34.20 4.89 4.73 0.76 0.43
1.26
0.86
82016a
Uncertainty
0.19 0.19 0.13 0.06 0.06 0.04
0.05
0.02
NCS FC
Certified Value
25.60 10.40 7.17 39.62 3.71 9.04
0.48
0.78
82017a
Uncertainty
0.19 0.13 0.15 0.51 0.05 0.15
0.04
0.03
Note:
1.Each certified value is the mean of analytical results of 9 independent laboratories.
0.79
0.03
0.25
0.01
0.52
0.02
0.78
0.02
0.42
0.04
0.83
0.03
0.28
0.02
0.11
0.01
0.38
0.01
0.55
0.03
0.25
0.01
0.04
0.01
Uncertainty U= tα(m-1)ST,
Al2O3 Fe2O3 CaO MgO
(%)
SO3
TiO2
ST is standard deviation.
2.The sample is packed in bottle with size less than 80 meshes. The minimum package is 30 grams.
3.The sample should be protected from contamination when use.
It should be stored at dry and cool place.
4.The sample should be grinded to less 160 meshes and stoved at 815°C±10°C to constant
weight before analysis. The minimum weight for analysis is 010g.
5.The valid time of the sample is 5 years, although we reserve the right to make change as
issue revisions.
Analytical Methods
Composition
SiO2
Al2O3
Fe2O3
CaO
MgO
SO3
TiO2
K2O
Na2O
P2O5
Analytical method
Silicon-molybdenum blue photometric method;
Inductively coupled plasma method; Gravimetric method
Fluoride replacement-EDTA titrimetric method;
Inductively coupled plasma method
EDTA volumetric method; Atomic absorption spectrophotometry
Photometric method after separation with titaniumferron
EGTA volumetric method; EDTA volumetric method;
Atomic absorption spectrophotometry
EDTA volumetric method; Atomic absorption spectrophotometry
Coulomb-titrimetric method; Gravimetric method
Photometric method after separation with titaniumferron;
H2O2 photometric method
Atomic absorption spectrophotometry; Flame spectrometry; ICP-AES
Atomic absorption spectrophotometry; Flame spectrometry; ICP-AES
Phosphorus molybdenum blue photometric method;
Inductively coupled plasma method