IBX TECHNICAL SPECIFICATIONS ashburn 2 (dC2) IBX® Center about location power Equinix operates International Business Exchange™ (IBX®) data centers across 18 markets in North America, Europe, and Asia-Pacific. These IBX centers serve as a reliable and secure destination for the world’s most powerful networks and companies. It’s what we do every day•without compromise. 21715 Filigree Ct. Ashburn, VA 20147 Electrical Capacity – 1.75 kW per cabinet UPS Configuration –N+1 Distributed Redundant System # of Utility Feeders – 1 # of Power Transformers – 7 Utility Voltage – 480 volts, 3-phase Standby Power – Six 2,000 kW diesel engine-generator power Standby Power Config. – N+1 Equinix operates five IBX centers in a campus environment and offers a full range of premium colocation, interconnection and support services to a wide range of networks, enterprise, content companies and financial institutions. Because of the area’s strategic importance as the Eastern hub of traffic exchange to the United States, Equinix’s DC metro IBX centers are one of the largest Internet exchange points in the world. From Airports – 6 miles to Dulles Intl Airport (IAD); 33 miles to Washington National Airport (DCA); 61 miles to Baltimore-Washington Intl Airport (BWI) Location Orientation – 33 miles to the White House Parking – Adjacent building parking available (no charge) Profile Phone – 1.888.892.0607 (USA or Canada) or 1.650.513.7600 (outside USA or Canada) Email – [email protected] Cooling Capacity – 1.75 kW per cabinet (5973 BTUH ) Cooling Plant – Water-cooled centrifugal chillers & air handlers security Square Footage Breakdown (Sq. Ft.) Leased 147,600 Colocation Area 118,447 0 Flex Space 1,867 Satellite Platform Telco Information © 2008 Equinix, Inc. | www.equinix.com Cooling NPA/NXX 703-723 CLLI code ASBNVAAS LEC VERIZON LATA 246 Physical – “Man trap” entry Human – 24x7 security gaurds Electronic – CCTV and Recorders, Motion Detection, Hand Geometry Readers, Fiber Vault IBX TECHNICAL SPECIFICATIONS ashburn 2 (dc2) IBX® Center building Construction Type – Single story, tilt-up concrete, steel, concrete slab on grade Building Type – 2-C Fully Sprinklered Floor Load Capacity – 250 PSF building code compliance Building – 1996 BOCA National Building Code with Virginia State Supplement Mechanical – 1996 International Mechanical Code Plumbing – 1995 International Plumbing Code Electrical – 1996 National Electric Code Life Safety – 1996 NFPA 13 - Installation of Sprinkler Systems; 1996 NFPA 72 - National Fire Alarm Code Other – N/A Significant building Dates Year Base Building Constructed – 2000 Year Base Building RETROFITTED – N/A Year EQIX IBX Constructed – 2000 Lateral Load Design Seismic EPV(Av) – Av = 0.05 Seismic EPA(Aa) – Aa = 0.05 Seismic Hazard Exposure – SHEG = 1 Seismic Importance Factor Ie – N/A Seismic Zone – 1 Fire protection Fire Suppression – Double-interlocked, pre-action (dry pipe) Fire Rating – Not required by code interconnection options System – Overhead proprietary cable tray system with multi-tier ladder rack Cross Connects Available – SingleMode fiber, Multi-Mode fiber (62.5 and 50 micron), CAT5, CAT6, CAT5 (T1), and CAT3 (POTS) Intra-Building Innerduct (IBID) Available – a dedicated private path via a conduit between buildings or customers Chicago CH1 Chicago CH2 Chicago CH3 Elk Grove Dallas DA1 Dallas Los Angeles LA1 Los Angeles LA2 Los Angeles LA3 El Segundo New York NY1 Newark NY2 Secaucus NY3 New York City1 NY4 Secaucus Silicon Valley SV1 San Jose (North) SV2 Santa Clara SV3 San Jose (South) SV4 Sunnyvale Washington DC1 Ashburn DC2 Ashburn DC3 Ashburn DC4 Ashburn DC5 Ashburn2 1. 2. Equinix Exchange Services only All DC5 IBXs are same campus IBX centers in the North America region EQUINIX CONFIDENTIAL—Subject to change without notice. For distribution to existing Equinix customers, or to persons who have signed an Equinix Non-Disclosure Agreement. © 2008 Equinix, Inc. | www.equinix.com Each private path innerduct is 1.25” in width. Customer runs their own Single-mode fiber within the innerduct which can potentially fit 432 standard cross connects. Equinix Exchange™ Available – Central switch for public and private peering Equinix Direct™ Available – Automated network provisioning, multi-homing and billing
© Copyright 2024 ExpyDoc