The Free Share Rolling Bungalow :: plans for a one and one-half story, 160 sq. ft. Tiny House :: THE small HOUSE CATALOG 1574 Gulf Road #214 Pt. Roberts, WA 98281 W W W . T H E S M A L L H O U S E C A T A L O G . C O M DESIGNED & DRAFTED BY SHAWN A. DEHNER 2010 RELEASED: SEPTEMBER 2011 REVISED: JULY 2013 REVISED & UPDATED: AUGUST 2014 ANCHORS: H1 HURRICANE TIES, RAFTER RIDGE CONNECTORS, METAL STRAPPING, HDU2'S AND A23/A35 RIGHT ANGLE CLIPS ARE RECOMMENDED FOR THIS TINY HOUSE. STOCK PLAN DISCLAIMER: 1) THE small HOUSE CATALOG has prepared these documents to meet generally accepted professional standards and practices. However, they have been designed without any knowledge of – or reference to – the Licensee’s specific site or geographical location. Specific site conditions may vary and include but are not limited to such things as: such as frost depth, soil bearing capacity, seismic and wind zones, etc. In addition, local code requirements, including such life-safety requirements as stair width, stair rise and run, egress windows and smoke detectors, etc. may vary. The strength of materials (e.g. lumber) available may vary. Therefore, supplemental to these documents, it is the Licensee’s responsibility to consult with his/ her chosen builder, local building department and a structural engineer to determine that these documents meet all current federal, state/provincial and local codes, ordinances/bylaws and regulations, etc., and are appropriate to specific site conditions. Compliance with such requirements shall take precedence over these documents. 2) Any use of this information without adaptation to changes in codes, standards, site conditions and other factors is at the Licensee’s sole risk. THE small HOUSE CATALOG assumes no responsibility for changes made to these plans by others and makes no warranties, either expressed or implied, in the use of these plans. The Licensee agrees to defend and indemnify THE small HOUSE CATALOG for all claims, costs, losses or damages resulting from the use of these documents. 3) Before starting construction, it is the builder’s responsibility to check all dimensions and details, and verify conformance with governing code requirements for the geographic area in which the house is to be built. All structural, mechanical and electrical requirements shall also be reviewed before construction begins. Codes govern over drawings and dimensions govern over scale. Please notify THE small HOUSE CATALOG of dimensional discrepancies. 4) THE small HOUSE CATALOG has not been engaged for construction supervision of any kind and assumes no responsibility to ensure that construction conforms to these plans, nor has any responsibility for construction means, methods, techniques, sequences, procedures or safety precautions in connection with the work. 5) This is not a sale of original documents. THE small HOUSE CATALOG retains ownership of all original documents and all subsequent copies (regardless of format). 6) The Licensee is granted the right to make copies as needed for the construction of one (1) building per plan purchase and/or free download. THE small HOUSE CATALOG requests that you honor this copyright policy. Additional rights can be easily purchased at a reasonable price from THE small HOUSE CATALOG office. 7) Terms and conditions apply to all plans. FLOOR JOISTS: JOISTS ARE INSTALLED, LOCATED & SPACED ACCORDING TO THE DESIGN. ANY JOISTS HAVING A SLIGHT BOW EDGEWISE SHOULD BE PLACED WITH THE CROWN ON TOP. JOISTS ARE CANTILEVERED TO SUPPORT A LIGHT FRAMED WALL & ROOF. INSTALL BLOCKING BETWEEN JOISTS TO TRANSFER CONCENTRATED LOADS TO TRAILER BELOW & TO PREVENT JOISTS ROLLING. PRODUCT QUALITY: 1. CONSIDER SPECIAL ORDERING FORMALDEHYDE-FREE PLYWOOD. 2. USE ZERO-VOC, NON-TOXIC & NON-CARCINOGENIC PAINTS & STAINS. 3. USE ZERO-VOC, NON-TOXIC & NON-CARCINOGENIC CAULKS, SEALANTS & ADHESIVES. 4. AVOID POLYSTYRENE RIGID BOARD INSUL., WHICH CONTAINS BROMINATED FIRE RETARDANTS. BUGS & PESTS: NO BROAD SPECTRUM INSECTICIDES OR HERBICIDES TO BE APPLIED BEFORE, DURING OR AFTER THE FOUNDATION WORK. APPLY TERMITE SHIELDS, IF REQ'D. PROPERLY SCREEN ALL VENTS & OPENINGS. BORATES (STANDARD BORAX) CAN BE APPLIED INSIDE WALL CAVITIES IN CLIMATES WHERE INSECTS MAY BE PROBLEMATIC. ROOF FRAMING NOTES: 1. NUMBER OF JACK STUDS FOR ALL GIRDER & HEADER SPANS PER IRC TABLE R502.5 (1) & (2) - FOOTNOTE 'D'. 2. POSITIVE CONNECTION & TRANSFER OF LOAD FROM ROOF TO LOAD SUPPORTING ELEMENTS REQ'D. 3. PROVIDE ANCHORAGE OF BEAMS OR GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 & R802.11 4. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER SCHEDULE, IRC TABLES R602.3 (1) THRU (5). 5. SOLID BLOCKING REQ'D @ ALL BEARING POINTS OF FLOOR, CEILING & ROOF SYSTEMS AS PER IRC SEC'S R502 & R802. 6. PROVIDE VENTILATION PER IRC SEC R806. ELECTRICAL: 1. KITCHEN & BATHROOM, BASEMENT OUTLETS TO BE GFCI. 2. EXTERIOR OUTLETS TO BE WEATHER PROOF. 3. AFCI RECOMMENDED IN SLEEPING LOFTS. PLUMBING: 1. KITCHEN SINKS: DWV MIN. 2" DRAIN & 1 1/2" VENT. 2.BATHROOM SINKS: DWV MIN. 1 1/4 DRAIN & VENT. 3. BATHTUBS: MIN. 2" DRAIN & 1 1/2" VENT. 4. SHOWERS: MIN. 1 1/2" DRAIN & VENT. 5. INCOMING WATER SUPPLY LINE: TYP. 3/4" - 1" 6. PRIMARY WATER SUPPLY LINE: TYP. 3/4" 7. INTERIOR WATER SUPPLY LINES: TYP. 1/2" 8. MAIN DRAIN LINE: TYP. 3" 9. MAIN STACK VENT: TYP. EQUAL OR > THAN MAIN DWV LINE. WEATHER PROOF OUTLET OR RANGE OUTLET O 240 240 OUTLET FIRST FLOOR AREA: 160 SQ. FT. SLEEPING LOFT AREA: 60 SQ. FT. STORAGE LOFT AREA: 18 SQ. FT. TOTAL FLOOR & LOFT AREA: 238 SQ. FT. FIRST FLOOR LOAD: 40 PSF LIVE / 20 PSF DEAD [SEE IRC TABLE R502.3.1 (2)] LOFT FLOOR LOAD: 20 PSF LIVE / 10 PSF DEAD [SEE IRC TABLE R802.4 (2)] ROOF LOAD: 20 PSF LIVE / 20 PSF DEAD [SEE IRC TABLE R802.5.1 (2)] THIS SECTION FOR YOUR NOTES & IDEAS $ SINGLE POLE WALL MOUNTED LIGHT SWITCH $3 3-WAY WALL MOUNTED LIGHT SWITCH CEILING LIGHT WALL LIGHT w CEILING LIGHT (WEATHER PROOF) w WALL LIGHT (WEATHER PROOF) $ PULL SWITCH CEILING LIGHT F CEILING EXHAUST FAN F DIRECT VENT WALL VENT SD SMOKE DETECTOR CO CARBON MONOXIDE DETECTOR WH ON-DEMAND WATER HEATER EMAIL: [email protected] 5) Terms and conditions apply to all plans. OWP O O O O O I I 4) House plans are non-refundable. OGFI GFI ELECTRICAL OUTLET 11111111 FRAMING: PRIOR TO START-UP, INSPECT TRAILER CONDITION AND COMPARE ALL DIMENSIONS WITH PLAN DIMENSIONS. IT IS POSSIBLE THAT YOUR SELECTED TRAILER WILL VARY SLIGHTLY WITH THE DIMENSIONS SHOWN, PARTICULARLY IN RESPECT TO WHEEL WELL SIZE AND OVERALL LENGTH & WIDTH. SWITCHED ELECTRICAL OUTLET 11111111 3) The Licensee is granted license to build one house per plan. Additional prints may be independently copied, as required, to build your house. Any changes to these plans must be confirmed by a licensed structural engineer and approved by your local code enforcement agency. OS 11 SITE PREPARATION: A SURFACE DRAINAGE PATTERN SHOULD BE ESTABLISHED WHICH WILL DRAIN THE ENTIRE AREA AND DIRECT WATER AWAY FROM THE TRAILER DURING & AFTER CONSTRUCTION. STANDARD ELECTRICAL OUTLET (DUPLEX) 11 2) THE small HOUSE CATALOG – including anyone who has been involved in the creation, production, or delivery of these documents – shall not be liable for any direct, indirect, consequential, or incidental damages. DESIGN FACTORS O 11 FASTENERS: FOR ALL PRESERVATIVE-TREATED & FIRERETARDANT TREATED: CONNECTORS SHALL BE TREATMENT RATED. FASTENERS SHALL BE HOT- DIPPED ZINC-COATED GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR COPPER. FOLLOW IRC TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS. THIS HOUSE DESIGN IS BASED IN PART ON THE 2012 INTERNATIONAL RESIDENTIAL CODE (IRC) & THE 2009 WASHINGTON STATE ENERGY CODE. ASPECTS OF THIS HOUSE DO NOT MEET STANDARD BUILDING CODES AND ARE TYP. EXEMPT FROM SUCH CODES AS LONG AS IT IS BUILT ON A TRAILER AND NOT ON THE GROUND. THIS INFORMATION SHOULD BE VERIFIED BY YOUR LOCAL CODE ENFORCEMENT AND BUILT ACCORDING TO LOCAL ZONING LAWS. THESE CODES WILL SUPERSEDE ANY INFORMATION CONTAINED WITHIN THESE DOCUMENTS. THE FREE SHARE TINY HOUSE ROLLING BUNGALOW TRAILER: ELECTRICAL LEGEND 11 1) These plans have been designed to satisfy generally accepted building requirements. However, THE small HOUSE CATALOG cannot guarantee that they will be appropriate for your specific conditions or that they will meet all the requirements of your local coding agency. It is the responsibility of the Licensee to see that they do. Consultation with your builder prior to submission of a permit application is recommended. DESIGN STANDARDS GENERAL NOTES GENERAL CONSTRUCTION NOTES: LICENSE AGREEMENT: 8) THE small HOUSE CATALOG can be contacted at P.O. BOX 1734, Pt. Roberts, WA 98281-1734. Tel. (360) 207-4513. Email: [email protected]. Website: www.thesmallhousecatalog.com 00 PRE-CUT STANDING SEAM METAL ROOF EMAIL: [email protected] BARGE RAFTER ONE SIZE WIDER THAN RAFTERS (E.G. 2X6 RAFTERS = 1X8 0R 2X8 BARGE) 3" O/HANG 13'-11" +/- 4-1/2" LAP SIDING W/3" EXPOSURE TRAILER HEIGHT 20'-0" +/FRONT ELEVATION NO SCALE - ISOMETRIC 1 2 LEFT ELEVATION NO SCALE - ISOMETRIC DICKINSON PROPANE STOVE VENT STACK W/ FACTORY SUPPLIED BELL OPT. 1X APRON BELOW SILL 2X WINDOW HEAD CASING W/ 1/2" O/HANGS THE FREE SHARE TINY HOUSE ROLLING BUNGALOW 1'-8" +/- 1X FASCIA 5/4" WINDOW RAILS 2X WINDOW SILL 3 08 METAL FLASHING OR SITEBUILT WATER TABLE & CAP ARE REQ'D 0/ WHEEL COVERS 8'-0" +/- 3 REAR ELEVATION NO SCALE - ISOMETRIC ELEVATIONS 4X4 PORCH POST 1X CORNER TRIM 4 RIGHT ELEVATION NO SCALE - ISOMETRIC 01 NOTES INDICATED WITH AN (*) ARE INCLUDED TO SHOW PRECISELY WHERE TINY HOUSES DEVIATE FROM THE MOST WIDELY ACCEPTED CODES. WHILE THESE CODES DO NOT STRICTLY APPLY TO TINY HOUSES BUILT ON TRAILERS AT THE TIME OF THIS PLAN'S DESIGN, IT'S GOOD PRACTICE TO CONSIDER WHY SOME OF THESE CODES HAVE BEEN ENFORCED & HOW THEY MIGHT EFFECT SOMEONE LIVING IN A TINY SPACE. WHERE POSSIBLE, THESE CODES HAVE BEEN INCORPORATED INTO THIS PLAN. 2'-6" 17'-6" 6'-0" 8'-7/8" 2'-8" PORCH 1 B ENTRY 2'-7" OFFICE NOOK A BATH 5'-11" 10'-6 1/2" 4'-11 1/2" 2 DINING AREA 1'-7 3/4" 2'-6" A 7'-4" 8'-0" 8'-3/4" B KITCHEN LIVING AREA 4'-8" 5'-4" 2'-1/2" WINDOW REQUIREMENTS*: 1. MINIMUM 5.7 SQ. FT. NET CLEAR OPENABLE AREA, EXCEPT GRADE FLOOR OPENINGS PERMIT MIN. 5 SQ. FT. OPENABLE AREA. 2. MINIMUM 24" NET CLEAR OPENABLE HEIGHT. 3. MINIMUM 20" NET CLEAR OPENABLE WIDTH. 4. SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR. 5. OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE. 4'-4 1/2" PROPANE FIREPLACE A 3'-1/2" 1'-7 3/4" B 7'-3/4" 8'-3/4" 3'-5 1/4" 20'-0" 1 07 SPACE FOR REMOVABLE INDUCTION COOK-TOP OR COUNTER SUNK BOAT/RV PROPANE STOVE 60" FULL FRIDGE TOASTER OVEN TOWERW/ STORAGE PLAN 1 FLOOR 1/2" = 1' 20'-0" STAIRS*: 1. STAIRWAYS & STAIRWAY LANDINGS, HANDRAILS & ILLUMINATION SHALL COMPLY WITH IRC SEC R311. GUARDS PER IRC SEC R312. 2'-9 1/2" 4'-0" SMOKE DETECTORS & CARBON MONOXIDE ALARMS*: C 8'-0" WATER EFFICIENCY*: 1. WATER EFFICIENCY STANDARDS FOR PLUMBING FIXTURES SHALL BE MAX. 1.6 GAL PER FLUSH & 2.5 GAL. PER MINUTE FOR SHOWER HEADS, L A V A T O R Y FAUCETS AND KITCHEN FAUCETS. BRACED WALLS*: FOLLOW IRC R602.10.3 & LOCAL CODE REQ'S. THIS TINY HOUSE HAS BEEN DESIGNED TO MEET AN SW4 SHEAR WALL RATING USING HDU2 HOLD DOWNS & IRC SHEAR ADD RAILING & ACCESS FOR WALL NAILING SCHEDULE. ADDITIONAL SINGLE SLEEPING LOFT 8'-8" 2'-5 1/2" STORAGE OR SINGLE BED SLEEPING LOFT MINUMUM FIREPLACE REQUIREMENTS*: 1. PROPANE & SOLID FUEL BURNING FIREPLACES INSTALLATION SHALL COMPLY WITH IRC CHAP. 10 2. PROPANE & SOLID FUEL BURNING FIREPLACES TO BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 8'-6 1/2" 4'-0" 8'-4" TEA TABLE (PLAN INCLUDED) VERTICAL LADDER 2'-1" (PLAN INCLUDED) 7'-4" C 8'-0" 1'-11" SLEEPING LOFT 4'-0" 4'-0" 2'-9 1/2" 8'-6 1/2" FLOOR PLANS 1'-5 1/4" A THE FREE SHARE TINY HOUSE ROLLING BUNGALOW A MINIMUM ROOM AREAS & CEILING HEIGHT*: 1. HABITABLE ROOMS PER IRC SEC R304 FOR FLOOR AREA. 2. HABITABLE ROOMS PER IRC SEC R305 FOR CEILING HEIGHT. SECOND FLOOR HALLWAYS, BEDROOMS & BATHROOMS TO MEET R305 - EXCEPTIONS (1) AND (2) FOR SLOPED CEILINGS. 1. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH IRC R314.3. 2. PROVIDE UL-2034 APPROVED CARBON MONOXIDE ALARMS OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF EACH BEDROOM IN ACCORDANCE WITH IRC R315.2 O 3'-5 1/8" A EGRESS*: 1. ALL ROOMS TO BE USED FOR SLEEPING PURPOSES & BASEMENTS WITH HABITABLE SPACE REQUIRE EMERGENCY & RESCUE OPENING COMPLYING WITH IRC SEC R310.1. 2. AT LEAST ONE DOOR SHALL MEET EGRESS REQ. IRC R311. THIS DOOR MUST BE SIDE HINGED WITH MIN. 32" (813 MM) CLEAR WIDTH WHEN MEASURED B/T THE FACE OF THE DOOR & THE STOP W/ DOOR AT 90 DEGREES (1.57 RAD.). MIN. CLEAR HEIGHT OF DOOR MUST NOT BE < THAN 78" (1981 MM) MEASURED FROM TOP OF THRESHOLD TO BOTTOM OF STOP. EMAIL: [email protected] FLOOR PLAN NOTES: 8'-8" 20'-0" PLAN 2 LOFT 1/2" = 1' 02 TRAILER NOTES: REMOVE DECKING BENEATH PORCH 2 HOLES @ EACH SIDE FOR HDU2'S (SEE SHEAR WALL NOTES, PAGE 05). 6'-0" +/- 2. IF YOU PURCHASE A USED TRAILER YOU WILL NEED TO REMOVE THE HORIZONTAL METAL COMPONENTS ABOVE THE TRAILER BED (EXCEPT THE WHEEL COVERS). EMAIL: [email protected] 3. IF YOU BUY A NEW TRAILER YOU CAN CUSTOM ORDER IT TO MEET YOUR NEEDS (SEE NO. 2 ABOVE) AND MAY ACTUALLY COST LESS THAN A USED ONE BECAUSE CERTAIN FEATURES (LIKE RAMPS) CAN BE OMITTED. A NEW TRAILER SHOULD ALSO INCLUDE FUNCTIONING BRAKE LIGHTS, BRAKING SYSTEMS, ETC., WHICH ARE THINGS THAT NED TO BE TESTED ON A USED TRAILER PRIOR TO PURCHASING. 9" +/- 6'-11" +/- 4. WHETHER YOU BUY NEW OR USED THE TYPE OF TRAILER YOU SELECT SHOULD HAVE A GROSS VEHICLE WEIGHT RATING (GVWR) OF 10K LBS. (MIN. 5K LBS. PER AXLE) AND YOU SHOULD VERIFY ALL SYSTEMS ARE IN WORKING ORDER. 5. PURCHASING A TRAILER WITH A BED THAT SITS 20" OR LESS FROM THE TOP OF THE BED TO THE GROUND WHEN THE TRAILER IS LEVEL WILL ENSURE YOUR ROLLING BUNGALOW WILL HAVE THE PROPER ROAD HEIGHT ONCE COMPLETED. 2 HOLES @ EACH SIDE FOR HDU2'S (SEE SHEAR WALL NOTES, PAGE 05). 7. SOME TRAILER MANUFACTURERS INCLUDE: 20'-0" +/- REMOVE DECKING TO PROVIDE DRAINAGE; USE P.T. OR CEDAR 2X4'S; INSTALL METAL FLASHING O/ LEDGER BOARDS; CEDAR 4X4 POST TUFF TRAILER (WWW.TUFFTRAILER.COM) BIG TEX TRAILERS (WWW.BIGTEXTRAILERS.COM) KAUFMAN TRAILERS (WWW.KAUFMANTRAILERS.COM) TRAILERS PLUS (WWW.TRAILERS PLUS.COM) 1 THE FREE SHARE TINY HOUSE ROLLING BUNGALOW 6. IF YOU HAVE A TRAILER MADE TO ORDER (RECOMMENDED) IT IS GOOD PRACTICE TO SHOW YOUR PLANS TO THE MANUFACTURER. THE MANUFACTURER MAY BE ABLE TO EXTEND THE DECKING SUBSTRUCTURE ALONG THE LONG SIDES OF YOUR TRAILER TO OFFER ADDITIONAL SUPPORT FOR THE FLOOR SYSTEM OF YOUR HOUSE. ESTIMATED TRAILER DIMENSIONS 1/2" = 1' 20'-0" MAIN FLOOR FRAMING NOTES 1'-6 3/4" 1'-7 1/4" 2'-0" 2'-0" 8'-6 1/2" 1'-6 1/4" 5 3/4" 2'-4 1/2" 2. 3/4" CDX PLYWOOD OR DIAG. BOARDS SUBFLOOR (INSTALL FLOOR INSULATION FIRST... ) 5'-11" 4 3/4" 5'-6 1/2" 1. 2X6 DF#2 FLOOR JOIST SYSTEM W/ JOISTS @ 24" O.C. 2'-0" 2'-0" 2'-0" 2'-3/4" 3. 2X4 P.T. OR CDR PORCH JOISTS. 4. BLOCKING RECOMMENDED B/T JOISTS 5. PORCH JOISTS SHOULD BE PRESSURE TREATED 2X DF #2 OR NATURALLY DECAY RESISTANT (CEDAR, E.G.) MATERIAL. 6. HOUSE TO BE ANCHORED TO TRAILER SUBSTRUCTURE WITH 5/8" ANCHOR BOLTS (OR STRONG-TIE HDU2 CONNECTORS) AT SHORT NON-CANTILEVERED ENDS OF HOUSE & TO TRAILER DECKING USING A23 OR A35 FRAMING ANCHORS WITH SSD SCREWS. IF THE LATTER METHOD IS USED, METAL STRAPPING SHOULD ALSO BE INSTALLED TO TIE THE HOUSE STRUCTURE DIRECTLY TO THE TRAILER SUBSTRUCTURE. 6. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER SCHEDULE, TABLES R602.3 (1) THRU (5). 2'-8" 8'-0" 8'-0" 5'-4" 1'-11 1/4" 1'-6 3/4" 1'-7 1/4" 2'-0" 5'-6 1/2" 2'-0" 1'-6 1/4" 5 3/4" 9. FOR ALL PRESSURE PRESERVATIVE & FIRE-RETARDANT TREATED WOOD USE TREATMENT RATED CONNECTORS & HOTDIPPED GALVANIZED, STAINLESS STEEL, SILICON BRONZE OR COPPER FASTENERS PER IRC SEC R317. 4 3/4" 8. LUMBER SHALL BE PROTECTED AGAINST ROT & DECAY PER IRC SEC R317. (TYP, P.T. OR CEDAR) 5 1/4" 7. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF FLOOR, CEILING & ROOF SYSTEMS PER IRC SEC'S R502 & R802 & IBC SEC'S 2308.8.2 & 2308.10.6. 2'-0" 5'-11" 2'-0" 2'-0" 8'-6 1/2" 2'-3/4" STRONG-TIE ANGLE CLIPS TRAILER & MAIN FLOOR FRAMING PLANS 1. A TYPICAL 7' X 20' CAR HAULER OR FLATBED TRAILER IS A GOOD CHOICE FOR A ROLLING BUNGALOW. 20'-0" 110 REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR FASTENERS & CONNECTORS. 2 CANTILEVERED FLOOR FRAMING O/ TRAILER 1/2" = 1' VISUAL NOTE: CONNECT EACH JOIST TO TRAILER DECKING W/MIN. 4 A23 OR A35 STRONG-TIE CLIPS BOTH SIDES @ 24" O.C. & USE METAL STRAPPING TO TIE RIM JOISTS TO TRAILER FRAMING. SEE SIDE NOTES FOR ALTERNATE METHOD. NOTE: IN DIMENSIONING OUT FRAMING PLANS, OVERALL PATTERN SPACING IS SOMETIMES LOST. REST ASSURED THAT THESE DIMENSIONS ARE ESTABLISHED AT SET PATTERNS, EITHER 16" OR 24" O.C., TO PROPERLY MANAGE STANDARD 4X8 SHEET GOODS. 03 WALL FRAMING NOTES: 1'-11 1/4" HOUSE HEIGHT: 3 1/2" SEAT FOR 2X4 WALL TIE 3 1/2" SEAT FOR 2X4 WALL TIE 1'-1 1/4" 1'-11 1/4" 20'-0" 1'-5" 1'-7 5/8" 3'-7 3/4" 3 1/2" RAFTER SEAT 1'-10 1/2" 1'-10 1/2" 1'-10 1/2" 3'-1/4" 4'-1/4" 1'-10 1/2" 2'-1 1/2" 1'-10 1/2" 4'-1/4" 4'-1/4" 7'-5 3/4" 11'-1 1/2" 4'-1/4" 7'-5 3/4" SHEAR WALLS: 6'-6" 1. TINY HOUSES SHOULD BE BUILT TO PROPERLY MANAGE LATERAL LOADS. IN ORDER TO DO THIS EACH EXT. HOUSE WALL MUST HAVE ONE SECTION W/ A MIN. 4X8 SHEET OF UNBROKEN PLYWOOD, PROPERLY NAILED TO SCHEDULE SW4 OR SIMILAR. CORNER BRACING IS HELPFUL BUT NOT A REPLACEMENT FOR SHEAR WALL NAILING SCHEDULES. 1'-6" 6" 2'-4 1/2" 1'-6 1/4" 11 1/2" 1'-1" 8'-6 1/2" 4'-9" 2 IMPORTANT NOTE: BE SURE TO VERIFY ROUGH OPENINGS FOR WINDOWS & DOORS WITH THE WINDOW MANUFACTURER PRIOR TO STARTING YOUR FRAMING. THSE DIMENSION MAY CHANGE OR YOU MAY USE WINDOWS W/ DIFFERENT R.O. DIMENSIONS. IT IS GOOD PRACTICE TO LAYOUT YOUR WALLS ACCORDING TO THE PLAN & VERIFY THE PLAN DIMENSIONS W/ YOUR ON-SITE DIMENSIONS, WHICH MAY BE SLIGHTLY DIFFERENT. SIMPLY ADJUST YOUR LAYOUT ACCORDINGLY. FRONT END WALL FRAMING PLAN 1/2" = 1' 3. PLYWOOD SHOULD INSTALLED AS PRESCRIBED ABOVE W/NON-TOXIC SHEAR WALL RATED ADHESIVE WHEREVER IT MEETS HOUSE FRAMING (STUDS, PLATES, ETC). RIGHT SIDE WALL FRAMING PLAN 1/2" = 1' 1'-11 1/4" GAP = LOFT JOIST 8'-0" C L 1'-1 1/4" 11 1/2" 16'-11" 1'-10 1/2" 1'-10 1/2" 1'-10 1/2" 3'-1/4" 2'-2 3/4" 1'-6" 2'-6 3/4" 4'-1/4" 4'-1/4" 7'-5 3/4" 6'-3 1/2" 1'-11 1/4" 1'-5" 1'-7 5/8" 1'-10 1/2" 11'-1 1/2" 3'-1/4" 7'-5 3/4" WALL ORIENTATION 1'-11 1/4" 1'-0" 1'-0" 1'-6 3/4" 2'-0" 1'-4 3/4" 8'-6 1/2" 6" 1'-6" 6" 1'-6" 5'-11" 1'-5 3/4" 1'-6 3/4" 3'-1/2" 2'-0" 1'-6 3/4" 2'-1 1/2" 1'-11 1/2" 1'-9 1/4" 6" KITCHEN 6 1/4" 5 1/2" BATH 7 1/4" OFFICE NOOK 2-2X6 HEADER W/ 1/2 PLY B/T 5 1/4" 1'-8 1/4" 1'-1 1/4" 2'-2 1/2" THIS WALL BORDERS PORCH TBD 6'-10 1/4" BATH/KITCHEN WALL BATH/OFFICE NOOK WALL 11 1/2" 3 1/2" SEAT FOR 2X4 WALL TIE 20'-0" 3'-7 3/4" 2'-11 1/2" 2'-3/4" 20'-0" 7'-5" 1 2'-0" WALL FRAMING PLANS 2'-3" 1'-6 1/4" 5'-11" 5'-6 1/2" 2'-4 1/2" 1'-5 1/2" 5 3/4" 1'-7 1/4" 5 3/4" 1'-6 1/4" 6 1/2" 2'-0" 4 3/4" 5" 2-2X6 HEADER W/ 1/2 PLY B/T 2. RECOMMEND SHEAR WALL: 1/2" CDX W/ 8D NAILS SPACED 3" O.C. @ EDGES, 12" O.C. IN THE FIELD. 2-HUD2'S @ EACH 8' SIDE OF TINY HOUSE CONNECTED TO TRAILER FRAMING. HOLES CAN BE DRILLED IN YOUR TRAILER'S SUBSTRUCTURE ON-SITE OR BY THE FABRICATOR WHEN PLACING AN ORDER. 1'-3 1/4" EMAIL: [email protected] 19'-5" THE FREE SHARE TINY HOUSE ROLLING BUNGALOW IF YOU INTEND TO MOVE YOUR PORTABLE HOUSE YOU'LL NEED TO DETERMINE THE TRAILER HEIGHT LIMITS FOR YOUR PARTICULAR STATE OR PROVINCE. AREAS VARY FROM 13'-6" (PRIMARILY IN THE EAST) TO 14'-0" (MOSTLY IN THE WEST). THESE PLANs ARE DESIGNED TO BUILD A 13'-11" +/- TALL HOUSE (INCLUDING A 20" HIGH TRAILER). IF YOU NEED TO ADJUST FOR 13'-6" LIMITS SIMPLY SUBTRACT THE NECESSARY 6-INCHES (ASSUMING YOU HAVE A 20" HIGH TRAILER) FROM THE FRAMING HEIGHT OF ALL WALLS. THIS IS A VERY SIMPLE SOLUTION & THE PLANS ARE DESIGNED TO WORK THIS WAY. 1'-1 1/4" 8'-0" C L 11 1/2" 11 1/2" 7'-5" 5 17'-6" INTERIOR WALL FRAMING 1/4" = 1' 3 LEFT SIDE WALL FRAMING PLAN 1/2" = 1' 2'-6" 4 REAR END WALL FRAMING PLAN 1/2" = 1' NOTE: IN DIMENSIONING OUT FRAMING PLANS, OVERALL PATTERN SPACING IS SOMETIMES LOST. REST ASSURED THAT THESE DIMENSIONS ARE ESTABLISHED AT SET PATTERNS, EITHER 16" OR 24" O.C., TO PROPERLY MANAGE STANDARD 4X8 SHEET GOODS. 04 FRAMING NOTES FLOOR JOISTS: JOISTS ARE INSTALLED, LOCATED & SPACED ACCORDING TO THE DESIGN, WHICH IS 24" O.C. ANY JOISTS HAVING A SLIGHT BOW EDGEWISE SHOULD BE PLACED WITH THE CROWN ON TOP. MAIN FLOOR JOISTS ARE DESIGNED TO CREATE A CANTILEVERED FLOOR SYSTEM. ALL JOISTS TO BE FASTENED TO TRAILER WITH FULLY SCREWED STRONG-TIE CLIPS. WHERE APPLICABLE, INSTALL BLOCKING BETWEEN JOISTS TO TRANSFER CONCENTRATED LOADS TO BEARING BELOW & PREVENT JOISTS FROM ROLLING. LOFT FLOOR JOIST ARE TIED TO CORRESPONDING STUDS W/ STRONG-DRIVE® SDS STRUCTURAL-CONNECTOR SCREWS SIZED 1/4" X 3" (340 LBS. SHEAR CAPACITY) TO FASTEN LOFT FLOOR JOISTS TO CORRESPONDING STUDS. 2'-10" 2X4 DF#2/SPF#2 LOFT FLOOR JOISTS @ 24" O.C. 8'-0" 2'-9 1/2" 1'-5 1/4" 6 3/4" 5'-2" 8'-6 1/2" 2'-0" 2'-0" 2'-2 1/4" 8'-8" 20'-0" 1 LOFT FLOOR FRAMING PLAN 1/2" = 1' 2X VENTED & SCREENED BLOCKING 2x4 LOOKOUTS, EVENLY SPACED; W/ 3/4" T&G DECKING ATTACHED BELOW 2x6 DF#2/SPF#2 RIDGE BEAM 8'-3" 2X6 DF#2/SPF#2 RAFTERS @ 24" O.C. W/ H1 HURRICANE TIES & MIN. R-19 INSUL.; LEAVE 1" VENTILATION GAP (BAFFLE) B/T INSUL. & ROOF DECKING 1X LEDGER BOARD LET-IN TO STUDS 1'-11 1/4" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" EMAIL: [email protected] 8'-8" THE FREE SHARE TINY HOUSE ROLLING BUNGALOW 8'-6 1/2" LOFT & ROOF FRAMING PLANS 2'-9 1/2" 5 3/4" ROOF FRAMING NOTES: 1. NUMBER OF JACK STUDS FOR ALL GIRDER & HEADER SPANS PER IRC TABLE R502.5 (1) & (2) - FOOTNOTE 'D'. 2. POSITIVE CONNECTION & TRANSFER OF LOAD FROM ROOF TO LOAD SUPPORTING ELEMENTS REQ'D. 3. PROVIDE ANCHORAGE OF BEAMS OR GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 & R802.11 4. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER SCHEDULE, IRC TABLES R602.3 (1) THRU (5). 5. SOLID BLOCKING REQ'D @ ALL BEARING POINTS OF FLOOR, CEILING & ROOF SYSTEMS AS PER IRC SEC'S R502 & R802. 6. ATTIC VENTILATION PER IRC SEC R806. 7. ROOF TOTAL WIDTH NEEDS TO BE 102" OR < @ FASCIA TO BE ROAD LEGAL IN MOST STATES & PROVINCES. 8. 12" OVERHANG @ GABLE ENDS & 3" OVERHANGS @ SIDES (INCLUDING FASCIA). 9. ROOF PITCH = 12:12 10. STRONG-TIE H1 HURRICANE CLIPS @ EACH FULL BEARING RAFTER 11. STRONG-TIE RR CONNECTORS @ EACH FULL BEARING RAFTER OR COLLAR TIES SPACED NOT LESS THAN 48" O.C. 12. MIN. 1/2" ROOF SHEATHING. 13. PROVIDE AN INSULATION BAFFLE (I.E. A CONTINUOUS VENT) BUILT FROM RIGID FOAM BOARDS TO PREVENT CONDENSATION BUILD-UP INSIDE ROOF ASSEMBLY. NOTE: VENTILATION IS THE MOST OVERLOOKED COMPONENT OF TINY HOUSES. PLEASE VENTILATE YOUR ROOF SYSTEM & INSTALL ADEQUATE MECHANICAL VENTILATION IF YOU INTEND TO USE YOUR TINY HOUSE FOR EXTENDED PERIODS OF TIME &/OR YOU EXPECT TO USE YOUR TINY HOUSR IN HEAVILY CONDITIONED AREAS IN THE NORTH OR SOUTH. 20'-0" 2'-3/4" 20'-0" 2 ROOF FRAMING PLAN 1/2" = 1' 05 NOTE: IN DIMENSIONING OUT FRAMING PLANS, OVERALL PATTERN SPACING IS SOMETIMES LOST. REST ASSURED THAT THESE DIMENSIONS ARE ESTABLISHED AT SET PATTERNS, EITHER 16" OR 24" O.C., TO PROPERLY MANAGE STANDARD 4X8 SHEET GOODS. 06 FULL FRAMING OVERVIEW THE FREE SHARE TINY HOUSE ROLLING BUNGALOW EMAIL: [email protected] 2X6 RIDGE BEAM BUILDING NOTES: 3'-6 3/4" 2X VENTED & SCREENED BLOCKING BARGE RAFTERS @ ENDS 7'-4" 6" 1/2" CDX PLYWOOD SHEATHING W/ 30# FELT 2X6 VENTED RAFTERS 2X VENTED BLOCKING DBL. TOP PLATE WHEEL WELL COVERS BOXED & INSUL.; CABINETRY BUILT OVER TOP OF BOXES 7 3/4" MAIN FLOOR SYSTEM: 3/4" T&G WOOD FLOORING 3/4" CDX PLYWOOD OR DIAG. BOARD SUBFLOOR 2X6 DF OR SPF #2 FLOOR JOISTS @ 24" O.C. JOISTS FASTENED TO TRAILER DECKING W/ STRONG-TIE ANGLE TIES & SDS SCREWS. FLOOR SYSTEM TIED TO TRAILER SUBSTRUCTURE W/ METAL STRAPPING. 2-3 LAYERS OF 1-1/2" THERMAX POLYISOCYANURATE BOARD INSUL. (MIN. R-19) 2X4 LOFT JOISTS W/ 3/4" T&G DECKING TOP & BOTTOM SCREENED VENT 3-IN SDS SCREWS X 3 +6'-7 1/2" TO SUBFLOOR 2X6 JOISTS @ 24" O.C. W/ R-19 INSUL. 1'-8" +/- TRAILER: 7X20 DROP DECK STYLE TRAILER. 10K CAPACITY. 20" HEIGHT FROM GROUND TO TOP OF DECKING. MIN. 2-AXLE W/ 5000K RATING PER AXLE. 1X FASCIA 1 ADD SHEATHING OR FLASHING BELOW CANTILEVERED FLOOR JOISTS 1x4 LEDGER LET-IN TO STUDS SECTION THRU HOUSE 1/2" = 1' 2X4 STUDS W/ 3/4" T&G INT., 1/2" CDX PLYWOOD EXT. HEATING SYSTEM: DICKINSON PROPANE FIREPLACE CONVECTION STYLE ELECTRIC WALL BACK-UP HEATER 7'-5 3/4" VENTILATION SYSTEM: EXHAUST FAN @ KITCHEN (150 CFM) EXHAUST FAN BATHS & LAUNDRY (110 CFM) VENTED ROOF ASSEMBLY 1X4 OR 1X6 T&G PANELS, PINE TYP. ADD RAFTER RIDGE CONNECTORS @ FLUSH MOUNTED RAFTER, EACH SIDE ADD 2X4 COLLAR TIES IF RR CONNECTORS ARE NOT USED THE FREE SHARE TINY HOUSE ROLLING BUNGALOW 6'-9 1/2" STANDING SEAM METAL ROOFING 3/4" HARDWOOD O/ BROWN BUILDING PAPER, TYP. 3/4" PLY 08 2X6 (0R 2X8) JOISTS W/ 3/4" CDX PLYWOOD SUBFLOOR & 1/2" CDX SHEATHING UNDER @ EXPOSED CANTILEVER 2 H1 HURRICANE TIE @ FULL BEARING RAFTERS 2X6 DF#2/SPF#2 RAFTERS @ 24" O.C. W/ H1 HURRICANE TIES & MIN. R-19 INSUL.; LEAVE 1" VENTILATION GAP (BAFFLE) B/T INSUL. & ROOF DECKING ADD STRUCTURAL 2X VENTED & SCREENED BLOCKING B/T RAFTERS 5 1/2" 6 1/2" TRAILER BED 1/2" SHEATH BELOW CANTILEVER 3 2 SECTION THRU HOUSE LOFT FLOOR SYSTEM: 3/4" T&G WOOD DECKING 2X4 DF OR SPF #2 LOFT JOISTS @ 24" O.C. (JOISTS FASTENED TO CORRESPONDING STUDS W/ 3-SDS SCREWS @ EACH SIDE) TRAILER HEIGHT FROM GROUND TO TOP OF DECKING 1X EAVE FASCIA 08 13'-11" +/- 2X4 STUDS @ 24" O.C. W/ R-19 INSUL. 2X4 STUDS @ 24" O.C. W/ R-19 INSUL. 2X4 JOISTS @ 24" W/ 3-SDS SCREWS EACH SIDE 3 WALL SYSTEM: SIDING: CEDAR CLAPBOARD 1/2" RAIN SCREEN 30# HOUSEWRAP 1/2" CDX PLYWOOD SHEATHING 2X4 DF OR SPF #2 STUDS @ 16" O.C. HORIZ. 2X HEADERS CAULKING AT ALL STUD JOINTS 2 LAYERS OF 1-1/2" THERMAX POLYISOCYANURATE BOARD INSUL. (MIN. R-19) CAULKING @ PLATES CAULKING & SEALANT @ EXT. DOORS AND WINDOWS INTERIOR SURFACE: 3/8"-3/4" T&G WOOD PANELING NON-TOXIC INTERIOR LATEX PAINT 2X6 RAFTERS @ 24" O.C. W/ R-19 INSUL. EMAIL: [email protected] 2X4 COLLAR TIES @ 24" O.C. ROOF SYSTEM: ROOFING: METAL STANDING SEAM 30# FELT W/ 6" MIN HEAD & SIDE LAPS 1/2" CDX SHEATHING 2X6 DF OR SPF #2 RAFTERS @ 24" O.C. 1" AIR GAPR B/T SHEATHING & INSUL. 2-3 LAYERS OF 1-1/2" THERMAX POLYISOCYANURATE BOARD INSUL. (MIN. R-19) 3/4" T&G WOOD CEILING OR 5/8" G.W.B. NON-TOXIC NATURAL FINISH OR LATEX PAINT. WALL SECTION 1"= 1' ROOF SECTION SHOWING CONNECTIONS 3/4" = 1' 07 BOARD INSUL.INSTALLED 1" BELOW ROOF SHEATHING AIR FLOW 1" AIR GAP CONT. TO & VENTED @ RIDGE; THIS DESIGN PREVENTS MOISTURE BUIL-UP AND EXCESSIVE HEAT INSIDE YOUR TINY HOUSE AIR GAP B/T BLOCKING & INSUL. VENTED BLOCKING W/ MESH BUG SCREEN EMAIL: [email protected] 1/2" SHEATHING O/ INSUL BAFFLE (NOT SHOWN, INSTALL @ TIME OF FRAMING) 1X4 LEDGER BOARD LET-IN TO STUD WALL 2X4 STUD NOTCHED TO RECEIVE LEDGER 2 THE FREE SHARE TINY HOUSE ROLLING BUNGALOW AIR FLOW VENTED EAVE DETAIL NO SCALE - ISOMETRIC 1/2" STRUCTURAL SHEATHING W/ SW4 SHEAR WALL NAILING SCHEDULE & ADHESIVE 2X4 LOFT JOISTS CONNECTED TO STUDS W/ 3-SDS SCREWS O/ 1X4 CONT. LEDGER 2X4 STUDS @ 24" O.C. W/ MIN. R-19 INSUL. 30# BUILDING PAPER 5° BEVEL FOR EXT. CASINGS 3/8" - 3/4" PLYWOOD OR WOOD RAIN SCREEN EXT. SHEATHING 2X HEAD CASING 2x6 (OR 2x8) CANTILEVERED FLOOR JOISTS @ 24" O.C. 1 1/4" 5/4" RAILS 2" 4-1/2" CLAPBOARD W/ 3" REVEAL SILL DETAIL 2X SILL W/ CHAMFERED EDGES 5/4" APRON, OPT. 3 1 TYP. WALL TREATEMENT NO SCALE - ISOMETRIC INT. & EXT. WINDOW CASINGS DETAIL CONSTRUCTION DETAILS 1" 15° BEVEL 1" = 1' NOTE: POCKET-HOLE JOINERY IS A GREAT WAY TO ASSEMBLE WINDOW CASINGS AT GROUND LEVEL. PLEASE SEE OUR BLOG ENTRY ABOUT SITE-BUILT WINDOW CASINGS TO LEARN MORE. 08 INTERIOR VIEWS 3/4 T&G WALL PANELS SEE WINDOW CASINGS DETAIL, PAGE 10, FOR WINDOW TREATMENT INSTALL ALUM. OR METAL 3" KIT. EXHAUST VENT HERE *NOTE: FOR DETAILED INFO. ABOUT APPLIANCES & FIXTURES, REFERENCE THE MATERIALS LIST ON PAGE 13. ADD PLATFORM FOR PROPANE CANISTER &/OR UTILITY STORAGE BOX FOLDING DINING TABLE BUILT FROM PLANED 2X STOCK W/ DOWEL JOINERY, OR SIMILAR SPLIT SECTION ISOMETRIC* No Scale 4" WIDE WINE, TEA & COFFE CUP CABINET; ADD HOOKS & BARS, AS DESIRED SITE-BUILT 1X6 T&G BATHROOM DOOR 5 1/2" 1 THE FREE SHARE TINY HOUSE ROLLING BUNGALOW 3/4" WOOD FLOORING 1'-0" 120 CFM DIRECT WALL VENT FAN UNDER CORNER CABINET 1'-6" BUILD TO DESIRED HEIGHT 6'-9 1/2" 6'-9 1/2" INSTALL OPEN PANTRY & DRAWERS, AS DESIRED 6'-9 1/2" 5'-9 1/2" 3'-0" 2'-0" 2'-3" 1'-8 5/8" 3 5/8" 3'-0" 1'-11 5/8" 2'-0" 1'-5/8" 11 1/4" 2'-0" 7'-11 1/4" 2 EMAIL: [email protected] USE FACTORY VENT KIT IF USING PROPANE FIREPLACE KITCHEN VIEWS* 1/2" = 1' TYP. FIXTURES 1-1/4" TOP RAILS 1/2" NOTCH 1-3/4" BOTTOM RAILS ADJ. CABINETS TO DESIRED HEIGHTS & TO WORK AROUND SELECTED TOILET & SINK 6'-9 1/2" 2X LEGS, PLANED SHELVING, OPT. 8'-6" +/- 6'-9 1/2" 2" DOWELS OR SCREWS TUB COMBO OR SHOWER 2'-0" 3 BATHROOM VIEWS* 1/2" = 1' 11 1/4" 1'-5 1/2" 2" DOWELS 10 1/2" 2'-7" FINISHING DETAILS 2x12 TOP, CHAMFERED & SANDED MIRROR OR STORAGE CABINET, AS DESIRED SCREWS 2'-7" 4 LOFT LADDER (IN CONTEXT) 1/2" = 1' 5 TINY HOUSE "SCRAP WOOD" TEA TABLE 1/2" = 1' 09 ELECTRICAL LEGEND 11 11 OGFI GFI ELECTRICAL OUTLET WEATHER PROOF OUTLET OR RANGE OUTLET 11 OWP 11111111 3" DRAIN OUT, 2" VENT STACK PORCH OUTLET HANDY FOR HOLIDAY LIGHTS 11111111 O 240 240 OUTLET BATH EXHAUST RECOMMENDED IN COLD CLIMATES SUGGESTED 120V CONVECTION STYLE WALL HEATER (HARDWIRE OR PLUG) WATER HEATER 11 PROPANE FIREPLACE (SEE MATERIALS LIST) WH GFI SMOKE DETECTORS & CARBON MONOXIDE ALARMS: 1. PROVIDE SMOKE DETECTORS AS PER WITH IRC R314.3. 2. FOR SOLID FUEL HEATERS, PROVIDE UL-2034 APPROVED CARBON MONOXIDE ALARMS INSIDE SLEEPING LOFT IN ACCORDANCE WITH IRC R315.2 O OGFI O O O 11 11 11 F 11 11 1-1/2" WASHING MACHINE DRAIN UNDER COUNTER TO SINK DRAIN 1 OWP OWP 30-AMP RV INLET 11 WIRING: 1. 30 AMP SINGLE POLE INLET TO 30 AMP PANEL: 10-2 2. 20 AMP CIRCUIT 1 (BATH): 12-2 3. 20 AMP CIRCUIT 2 (KITCHEN GFI'S): 12-2 4. 15 CIRCUIT 3 (DINING AREA, OFFICE): 14-2 5. 15 CIRCUIT 4 (LIVING ROOM): 14-2 6. 20 CIRCUIT 5 (EXT. GFO OUTLETS): 12-2 7. ALT. OPT. ALL CIRCUITS = 20 AMP W/ 12-2 WASHER 11 ELECTRICAL NOTES GENERAL: 1. ALL KITCHEN, BATHROOM & EXT. OUTLETS TO BE GFI. 2. EXTERIOR OUTLETS TO BE WEATHER PROOF. 3. AFCI REQ'D IN SLEEPING AREAS. UNDER COUNTER WATER HEATER 11 WH SINGLE POLE 30 AMP BREAKER PANEL MAIN FLOOR ELECTRICAL, PLUMBING & LPG PLAN 1/2" = 1' PLUMBING: 1. KITCHEN SINKS: DWV MIN. 2" DRAIN & 1 1/2" VENT. 2.BATHROOM SINKS: DWV MIN. 1 1/4 DRAIN & VENT. 3. BATHTUBS: MIN. 2" DRAIN & 1 1/2" VENT. 4. SHOWERS: MIN. 1 1/2" DRAIN & VENT. 5. INCOMING WATER SUPPLY LINE: TYP. 3/4" - 1" 6. PRIMARY WATER SUPPLY LINE: TYP. 3/4" 7. INTERIOR WATER SUPPLY LINES: TYP. 1/2" 8. MAIN DRAIN LINE: TYP. 3" 9. MAIN STACK VENT: TYP. EQUAL OR > THAN MAIN DWV LINE. 10. IF YOU LIVE IN CANADA, OR HAVE ACCES TO SMALLER DWV PIPING, CONSIDER USING 1-1.4" DIA. IN LIEU OF 1-1/2" FOR EASIER INSTALLATION IN WALLS. STUB OUT FOR 1/2" SCHEDULE 40 STEEL PIPE OR GASFLEX TUBING FOR PROPANE FIREPLACE, IN-WALL & CONT. TO APPLIANCE. OPT. TEE-OFF FOR PROPANE STOVE @ KITCHEN. 11 O $3 TO MA IN F LOO RS WIT CO CH O I CARBON MONOXIDE DETECTOR OGFI CO O SMOKE DETECTOR $$ SD O SD OWP DIRECT VENT WALL VENT OGFI O F TO LOFT 11 O CEILING EXHAUST FAN 11 F O $ PULL SWITCH CEILING LIGHT F WALL LIGHT (WEATHER PROOF) 1/1/2" DRAIN, 1-1.2" HORIZ. VENT TO STACK 11 w $3 CEILING LIGHT (WEATHER PROOF) 1-1/2" DRAIN, 1-1/2" HORIZ. VENT TO STACK w WALL LIGHT w $ O O O O O O I I $$ CEILING LIGHT O I 3-WAY WALL MOUNTED LIGHT SWITCH 11 $3 O SINGLE POLE WALL MOUNTED LIGHT SWITCH O $ EMAIL: [email protected] SWITCHED ELECTRICAL OUTLET THE FREE SHARE TINY HOUSE ROLLING BUNGALOW OS 11 O VENT FIREPLACE WITH MANUFACTURER'S EXHAUST BELL/BOOT 2 ELECTRICAL, PLUMBING & LPG LINE PLAN STANDARD ELECTRICAL OUTLET (DUPLEX) 11 O LOFT ELECTRICAL PLAN 1/2" = 1' 10 1 MATERIALS ESTIMATE ONLY WINDOW SYMBOL UNIT SIZE R.O. TYPE FINISH GLASS REMARKS ITDH 2248 1'-10" X 4'-0" 1' 10-1/2" X 4' 0-1/4" DOUBLE HUNG WOOD/FG CLEAR 2W1H LITES ITDH 2236 1'-10" X 3'-0" 1' 10-1/2" X 3' 0-1/4" DOUBLE HUNG WOOD/FG CLEAR 2W1H LITES CUAWN 1620 1'-6" X 1'-8" 1' 5" X 1' 7 5/8" AWNING WOOD/METAL CLEAR 2W1H LITES QUANTITY MANF./STYLE MODEL NO. A 6 B 3 C 2 MARVIN INTEGRITY MARVIN INTEGRITY MARVIN INTEGRITY DOOR SCHEDULE WINDOW SYMBOL QUANTITY MANF./STYLE MODEL NO. DOOR SIZE R.O. TYPE FINISH GLASS REMARKS 1 1 SIMPSON N/A 2' 0" X 6' 4" 25-1/2" X 78" ENTRY SOLID WOOD CLEAR 6-PANEL OR CRAFTSMAN STYLE, GLASS OPT. 2 1 SITE-BUILT N/A 1' 6" X 6' 6" TBD INTERIOR SOLID WOOD NONE 3/4" T&G PANEL (CAN BE WIDER, IF DESIRED) 2 SCHEDULES WINDOWS & DOORS CLOSING NOTES: OUR BASIC TOOLBOX: 1. ALL SHEATHING IS STRUCTURAL & SHOULD BE NAILED, SCREWED & GLUED TO FRAMING MATERIAL. FOR NON-TOXIC ADHESIVES, PLEASE VISIT OUR RESOURCES PAGE AT OUR WEBSITE. BORING TOOLS: 1. PORTABLE DRILL-DRIVER 2. CORDED DRILL 3. SQUARE & PHILLIPS HEADS 4. SMALL DIAM. BRAD-POINT DRILL BIT SET 5. POCKET HOLE JIG 6. DOWELING JIG 2. WE RECOMMEND INSULATING YOUR ROLLING BUNGALOW TO A MIN. OF R-19 ALL AROUND (FLOORS, WALLS & CEILING) USING RIGID FOIL-FACED FOAM BOARDS. AND BE SURE TO MAKE A VENTED INSULATION BAFFLE PART OF YOUR ROOF ASSEMBLY. 3. IF YOU INTEND TO HAVE A BATHROOM & KITCHEN IT IS IMPERATIVE TO INSTALL PROPER MECHANICAL VENTILATION. TINY SPACES WILL ACCUMULATE MOISTURE FAST, ESPECIALLY DURING COLD WEATHER. MOISTURE CAN BE MANAGED BY EXHAUST FAN(S) AT CRUCIAL POINTS (BATHROOM & KITCHEN) & FULLY VENTING THE ROOF ASSEMBLY. 4. IF YOU CHOOSE A LARGER SIZED REFRIGERATOR (AS WE DID) YOU SHOULD INSTALL IT PRIOR TO HANGING YOUR FRONT DOOR (OR BE SURE YOUR APPLIANCE DOORS CAN BE TEMPORARILY REMOVED). USE SCREWS TO SET YOUR DOOR JAMBS IN CASE YOU EVER NEED TO REPLACE THE APPLIANCE. MOST REFRIGERATORS HAVE REMOVABLE DOORS, WHICH WILL ASSIST YOU SHOULD YOU NEED TO REMOVE IT AT SOME POINT. 5. A 30-AMP CONNECTION IS MORE THAN ADEQUATE TO RUN A FRIDGE, WATER HEATER, ELECTRIC COOKTOP, COMPUTER, LIGHTS, AND MORE, AS SHOWN IN THIS PLAN. IF YOU'RE UNFAMILIAR WITH ELECTRICAL WIRING, CONTACT AN ELECTRICIAN TO DO A "ROUGH-IN" JOB AND PROOF READ YOUR PLAN. 6. THE 2012 IRC (INTERNATIONAL RESIDENTIAL CODE) IS A GREAT RESOURCE FOR GENERAL CONSTRUCTION INFORMATION. IF YOU BUY ONE, YOU SHOULD BE ABLE TO EASILY SELL IT BACK ONLINE. AND MOST LIBRARIES HAVE THE IRC AVAILABLE. PLEASE USE ONE TO ASSIST YOU WHILE BUILDING TO AVOID CONSTRUCTION MISTAKES. 7. PLUMBING WATER LINES CAN BE 1/2" PEX LINES. A SIMPLE CRIMPING TOOL CAN BE BOUGHT FOR LESS THAN $100. TYP. HOUSE PLUMBING HARDWARE WORKS GREAT. A GOOD LIBRARY BOOK AND SOME BASIC TOOLS IS ALL YOU NEED TO DO YOUR OWN ROUGH-IN PLUMBING. IT'S EASIER THAN YOU MIGHT THINK. BLACK ABS PIPE IS MORE RIGID AND WORKABLE THAN WHITE PVC. 8. CANVAS WHEEL COVERS ARE A GOOD INVESTMENT BECAUSE SUN WILL DEGRADE YOUR TIRES. 9. PLEASE INSTALL A SMOKE DETECTOR IN YOUR TINY HOUSE. A CO2 DETECTOR IS REQ'D IF YOU INSTALL A FIREPLACE. AND ALWAYS KEEP A FIRE EXTINGUISHER ON HAND IN YOUR HOUSE. 10. EXPOSED EXTERIOR WATER PIPES CAN BE INSULATED (OR HEAT TAPED). IF YOUR AREA GETS COLD, ADDING ROCK SALT TO YOUR WASTE WATER LINES SHOULD PREVENT FREEZING. HAMMERING TOOLS: 1. WOODEN DALLUGE STYLE FRAMING HAMMER 2. 12 OZ. ESTWING STYLE FINISHING HAMMER 3. BRAD NAILER W/ LIGHTWEIGHT COMPRESSOR 4. FLOORING HAMMER (RENTED) 5. CHISELS CUTTING TOOLS: 1. 10" TABLE SAW 2. CIRCULAR SAW W/ 96" TRACK 3. D-HANDLE JIGSAW 4. SLIDING COMPOUND MITER SAW 5. HAND SAW(S) MEASURING & MARKING TOOLS: 1. FRAMING SQUARE 2. SPEED SQUARE 3. FOLDING CABINET RULER 4. COMBINATION SQUARE 5. 12" STEEL RULER 6. CHALK LINE 7. SPEED LEVEL 8. 48"-96" LEVEL PLANING TOOLS: 1. HAND PLANER 2. BENCH PLANER WE USE A VARIETY OF PLUMBING, GAS & ELECTRICAL AND HAND CABINET TOOLS. IF YOU HIRE THESE SERVICES OUT THEN YOU CAN FOREGO PURCHASING ADDITIONAL TOOL.S (RECOMMENDED IN MOST CASES). EMAIL: [email protected] WINDOW SCHEDULE THE FREE SHARE TINY HOUSE ROLLING BUNGALOW FLOOR SYSTEM: 1. 2X6X8 DF#2 (17) 2. 2X6X10 DF#2 (2) 3. 2X6X12 DF#2 (2) 4. 3X4X8 POLYISO RIGID FOAM BOARD INSULATION (5) 5. 3/4" CDX PLYWOOD (5) 6. 160 SQ. FT. BROWN BUILDING PAPER 7. 160 SQ. FT OF 3/4" FINISH FLOORING PORCH: 1. P.T. OR CDR 2X4X8 (2) 2. 2X4X8 CDR DECKING (9) 3. 4X4X8 CDR POST (1) WALLS: 1. 2X4X8 DF#2 (75) 2. 2X4X10 DF#2 (4) 3. 2x4x12 DF#2 (2) 4. 2X6X8 DF#2 (4) 5. 1/2" CDX PLYWOOD (17) 6. 3X4X8 POLYISO RIGID FOAM BOARD INSULATION (16) 7. 500-600 SQ. FT. OF 3/8" - 3/4" T&G INT. PANELING OR 1/2" G.W.B. 8. 500 SQ. FT. BUILDING PAPER OR HOUSEWRAP 9. 500 SQ. FT. OF SIDING LOFT FLOOR: 1. 2X4X8 DF#2 (8) 2. 1X4X10 DF#2 (2) 3. 5/8" 0R 3/4" T&G DECKING (100 SQ. FT) ROOF: 1. 2X6X8 DF#2 (30) 2. 2X4X8 DF#2 (5) 3. 2X4X12 DF#2 (2) 4. 1X8X8 DF#2 OR CDR (4) 5. 1X6X10 DF#2 OR CDR (4) 6. 3X4X8 POLYISO RIGID FOAM BOARD INSULATION (10) 7. 1/2" CDX PLYWOOD (10) 8. 265 SQ.. FT. OF ROOFING PAPER & ROOFING MATERIAL (YOUR CHOICE). MISCELLANEOUS FRAMING MATERIALS: 1. 16D, 10D AND 8D NAILS & 2. 1/4" X 3" SDS SCREWS 3. A23 RIGHT ANGLE CLIPS: 60 4. METAL STRAPPING 5. 4 HDU2 STRONG-TIE HOLD DOWNS 6. NON-TOXIC ADHESIVE (ECOBOND, CHEMLINK, ET AL.) WINDOWS & DOORS: (SEE SCHEDULES) ELECTRICAL & PLUMBING: (SEE PAGE 10) KITCHEN FIXTURES & APPLIANCES: 1. REFRIGERATOR MODEL LG #LRBP1031W 2. THE BREVILLE SMART OVEN MODEL #BOV800XL 3. HAIER SPACE-SAVING PORTABLE COMPACT ELECTRONIC 1 CUBIC FOOT TOP LOAD WASHER MODEL # HLP21N. 4. FULL SIZE IKEA SINK BOHOLMEN SINK 5. STANDARD TWO-BURNER BOAT OR RV STYLE PROPANE COOK TOP 6. OPTIONAL INDUCTION COOK TOP (MECHANICAL FAN & VENTING RECOMMENDED FOR FULL-TIME USE) 7. STIEBEL-ELTRON WATER HEATER MODEL #SHC4 8. LEE VALLEY CABINET HARDWARE (1-1/4" CHROME PLATE CATCHES & STAINLESS STEEL HINGES) BATHROOM FIXTURES: 1. LYONS (OR SIMILAR) 24" X 32" RV/BOAT BATHTUB WITH RIGHT SIDE DRAIN RECOMMENDED WITH CEDAR SHOWER SURROUND (SITE-BUILT USING CEDAR SIDING & MIRACLE COVER NON-TOXIC MARINE SEALER) OR FIBERGLASS SHOWER PANELS. 2. CORONA PROFILE SMART 305 WITH INTEGRATED SINK 3. BRICOR B100 ULTRA-MAX SHOWER HEAD* LIVING & DINING ROOM: 1. IKEA SOLSTA COUCH 2. LEE VALLEY 4-POSITION FOLDING BRACKETS (2) FOR FOLDING DINING TABLE 3. IKEA JOKK MOKK DINING TABLE CHAIRS (2) 4. NEWPORT PROPANE BOAT FIREPLACE BY DICKINSON MODEL #P9000 5. CONVECTION STYLE WALL HEAER (120V) - HARDWIRED OR PLUG - LOCATE AS DESIRED MISCELLANEOUS FINISHING MATERIALS: 1. CABINETRY MATERIALS TO BE ESTIMATED BY BUILDER. 2. BUILT-IN FURNITURE MATERIALS TO BE ESTIMATED BY BUILDER. 3. ANY OTHER CHANGES MADE BY OWNER OR BUILDER. 4. NON-TOXIC CAULKING FOR SEALING 5. SPRAY-FOAM FOR WINDOW SEALING IMPORTANT: VERIFY ALL WINDOW & DOOR INFORMATION W/ MANUFACTURER PRIOR TO CONSTRUCTION. MATERIALS, SCHEDULES & CLOSING NOTES, ETC. DISCLAIMER: THIS IS AN ESTIMATE OF THE MATERIALS YOU'LL NEED TO COMPLETE YOUR TINY HOUSE. IT WILL HELP GAUGE COSTS AND ASSIST WITH THE PRIMARY ORDER & DELIVERY. BE SURE TO CALCULATE 10% FOR WASTE, ETC. (BUT DON'T WASTE IT! BUILD SCRAP-WOOD FURNITURE FOR YOUR HOUSE). KEEP IN MIND ADDITIONAL MATERIALS WILL LIKELY BE REQ'D. SINCE YOUR INDIVIDUAL PREFERENCES WILL FINISH YOUR HOUSE. IT IS A PRIVILEGE & A JOY TO BUILD. YOUR COOL FOR TAKING ON THE CHALLENGE OF CREATING YOUR OWN HOUSE! REMEMBER TO WORK SAFELY... 11. BE SURE NOT TO EXCEED YOUR TRAILERS WEIGHT CAPACITY. WEIGH YOUR TRAILER BEFORE YOU START & USE A BATHROOM SCALE TO HELP YOU ESTIMATE WEIGHT AS YOU BUILD (OUR OWN TINY HOUSE WEIGHS ABOUT 8,000 LBS). 11
© Copyright 2025 ExpyDoc