s y s t e m s Magnetic Proximity Switch Catalog Magnetic Guide Sensor Catalog accurate systems Corporation 4729-3 Chuo,Ina-shi,Nagano 396-0015 Japan Tel : 81-265-98-7927 FAX : 81-265-98-7926 Oct/2012 1 s y s t e m s Specification Magnetic proximity switch MHS-1005 1. General MHS-1005 is a magnetic proximity switch which utilize a Hall element. MHS-1005 detects the magnetic field and identify the N pole and S pole. The outputs generate ON or OFF signal according to the detected magnetic pole. MHS-1005-N is activated by N pole and MHS-1005-S is activated by S pole. The operating magnetic field strength is set as 0.5mT and 0.8mT. 2. Specifications Power supply : DC+10〜30V Ripple less than 1% Current consumption: Less than 12mA : 0.5mT±0.01mT /0.8mT±0.01mT Activating point : Less than 0.03mT Hysteresis : NPN Transistor Open Collector Output (Normal Open) Output : NPN Transistor Open Collector Output (Normal Close) Withstand voltage DC30V max. Sink current 30mA max. : Less than 0.3 m second Response time : Magnet ( N pole or S pole, depends on the variation No.) Detection object : Power supply reverse connect, Output surge voltage Circuit protection : LED red Output indication : -10 〜+60℃ Operating temperature Operating humidity : 10 〜90% RH ( non-icing, non-condensing) : Less than 0.05mT/10℃ Temperature Coefficient Vibration : 5 G (10〜55Hz) : 50 G Shock : 50g Weight : φ5.1 PVC 1m length Cable : Brown : Power supply + : Blue : 0V : Black : Output : White : No connection : IP-65 Enclosure : 8Kgf.cm Fastening Torque 3. Wiring Brown Black Blue 2 s y s t e m s 4. Outline dimension No. ① Description Plastic case ② ③ Cable Nut Material Qty ABS ( Gray for MHS-1005-N ) 1 ( Blue for MHS-1005-S ) φ5.1 PVC (pig tail) 1m BS ( Nickel plated) 2 5. Installation MHS-1005 should be installed away from magnetic field generating objects such as a motor to avoid false operation due to the magnetic field interference. Since Ferro-magnetic material such as iron affects the magnetic field distribution, the activating range would be changed and distorted. To prevent this inadequate operation, the iron bracket should be kept away from the tip of the sensor as described below. d1=20mm d2=20mm 3 s y s t e m s 6. Ordering Guide MHS-1005-□-□□-□ Detection pole N: N pole S: S pole Sensitivity 05: 0.5mT 08: 0.8mT Output No description: Normal Open B: Normal Close 4 s y s t e m s Specification Magnetic proximity switch MHS-1008 1. General MHS-1008 is a magnetic proximity switch which utilizse a Hall element. MHS-1008 detects the magnetic field and identify the N pole and S pole. The dual outputs generate ON or OFF signal according to the detected magnetic pole. The operating magnetic field strength is set as 0.5mT and 0.8mT. 2. Specifications Power supply : Type V2: DC+24±10% Ripple less than 1% Current consumption: Less than 19mA : Type 05: 0.5mT±0.1mT Sensitivity Type 08: 0.8mT±0.1mT : NPN Transistor Open Collector Output (Normal Open) Output NPN Transistor Open Collector Output (Normal Close) Withstand voltage DC30V max. Sink current 30mA max. : Less than 0.3 m second Response time : Magnet ( N pole or S pole) Detection object : Power supply reverse connect, Output surge voltage Circuit protection : LED red (N pole) , LED green (S pole) Output indication : -10 〜+60℃ Operating temperature Operating humidity : 10 〜90% RH ( non-icing, non-condensing) : Less than 0.05 mT/10℃ Temperature Coefficient Weight : 50g : φ5.1 PVC 1m length Cable : Brown : Power supply : Blue : 0V : Black : Output ( N pole) : White : Output ( S pole) : IP-65 Enclosure : 8kgf.cm Fastening Torque 5 s y s t e m s 3. Wiring 4. Outline dimension No. ① ② ③ Description Plastic case Cable Nut Material ABS (black) φ5.1 PVC (pig tail) BS ( Nickel plated) Qty 1 1m 2 6 s y s t e m s 5. Installation MHS-1008 should be installed away from magnetic field generating objects such as a motor to avoid false operation due to the magnetic field interference. Since Ferro-magnetic material such as iron affects the magnetic field distribution, the activating range would be changed and distorted. To prevent this inadequate operation, the iron bracket should be kept away from the tip of the sensor as described below. d1=20mm d2=20mm 6. Ordering Guide MHS-1008-□-□□-□ Power supply V2: DC+24V±10% Sensitivity 05: 0.5mT 08: 0.8mT Output No description: Normal Open B: Normal Close 7 s y s t e m s Specification Magnetic proximity switch MHS-1043 1. General MHS-1043 is a magnetic proximity switch which utilizes a Hall element. MHS-1043 detects the magnetic field and identify the N pole and S pole. The dual outputs generate ON or OFF signal according to the detected magnetic pole. The operating magnetic field strength is set as 0.5mT and 0.8mT. 2. Specifications Power supply : DC+10…28V Ripple less than 1% Current consumption: Less than 15mA : 0.5mT±0.1mT Sensitivity 0.8mT±0.1mT : NPN Transistor Open Collector Output (Normal Open) Output Withstand voltage DC30V max. Sink current 30mA max. : Less than 0.3 m second Response time : Magnet ( N pole or S pole) Detection object : Power supply reverse connect, Output surge voltage Circuit protection : LED red (N pole) , LED green (S pole) Output indication : -10 〜+50℃ Operating temperature Operating humidity : 10 〜90% RH ( non-icing, non-condensing) : Less than 0.05 mT/10℃ Temperature Coefficient Hysteresis : Less than 0.3mT Insulation resistance : More than 100MO (between signal ground and attachment metal fitting) : 30g Weight : φ3.8 PVC 1m length Cable : Brown : Power supply : Blue : 0V : Black : Output ( N pole) : White : Output ( S pole) : IP-65 Enclosure Fastening Torque : 8kgf.cm Center of detection pole signal lamp (MHS-1043U) (red) Center of detection S pole signal lamp (green) (MHS-1043F) Resin case (ABS) 8 s y s t e m s 3. Ordering guide MHS - 1043 - □ - □□ Detection side Detection sensitivity Detection side Detection sensitivity U F 05 08 Upper side Front side 0.5mT 0.8mT 4. Installation MHS-1043 should be installed in non-ferrous material (aluminum, brass, SUS304, etc.) and kept away from magnetic field (e.g. motor). In case there is ferrous material (e.g. iron) near the detection center of the switch, magnetic flux distribution is disturbed and detection sensitivity is affected. In this case please make the space around the switch as below. d1>30mm, d2>20mm 5. Connections (sample) brown load load black north pole output white south pole output DC power supply In case of inductive load connection, protective circuit must be connected. (diode: 1A, 100V) blue Magnetic detection circuit 9 s y s t e m s Specification Guide Sensor UDS-1044 1. General UDS-1044 is a guide sensor for automated guided vehicles. UDS-1044 detects the magnetic tape on the route and the plural number of magnetic switches in the sensor housing turns ON when they detect the magnetic flux generated by the magnetic tape. The magnetic switch is allocated by 15 bits for guide and outputs the bit signals parallely. 2. Specifications Guide Tape (Rubber Magnet) 0.9 x 50 1) General physical property Specific gravity : 3.7 Hardness : 95 Hs(JIS A) (JIS K6301) Tensile strength : 62 kgf/cm2 (JIS K6301) Extension : 25%(JIS K6301) Operating : -10〜+80℃ temperature 2 ) Magnetic property Class : Anisotropy Residual magnetic : 0.24〜0.25T (2400〜2500G) flux(Br) Coercive force(BHC) : 2150〜2300 Oe Magnetizing : Magnetize equally in the direction of thickness direction Magnetic Induction Sensor Power supply : DC+24V±10% Ripple less than 1% Current : Less than 130mA consumption Sensitivity : 0.5±0.1mT (N pole) Output : NPN Transistor Open Collector Output (Normal Open) Withstand voltage DC50V max. Sink current 50mA max. Output ON voltage : Less than 0.5V Response time : Less than 0.3 m second Detection object : 0.9 x 50 guide tape (N pole) Hysteresis : Less than 0.03mT Installation position : 20mm (between guide tape surface and sensor detection side) Operating range :10〜35mm Circuit protection :Power supply reverse connect, output surge voltage Temperature : Less than 0.04mT/10℃ coefficient 10 s y s t e m s Operating : -10〜+50℃ temperature Operating humidity : 10 〜90% RH ( non-icing, non-condensing) Insulation resistance : More than 100MO (between signal ground and case) Enclosure : IP-65 3. Outline dimension Aluminum plate/t1.5 (Black alumite) Case (ABS resin) Flat cable Polarity mark Socket connector 2-φ6hole 4. Installation UDS-1044 should be installed away from the magnetic field generating objects. It should not be installed near a drive motor of the vehicle. It should be installed in a nonmagnetic bracket. In case there is a magnetic frame near sensor, the sensor should be kept away from the frame as below. Magnetic frame Magnetic frame 11 s y s t e m s The detection side of the sensor should be set parallel with the surface of the guide tape. 5. Wiring Pin No. 1 2 3 4 5 6 7 8 9 10 Connection NC No.1 output No.2 output No.3 output No.4 output No.5 output No.6 output No.7 output No.8 output No.9 output Pin No. 11 12 13 14 15 16 17 18 19 20 Connection No.10 output No.11 output No.12 output No.13 output No.14 output No.15 output NC NC Vcc 0V Input-output connector (male) Model No.: HIF3BA-20PD-2. 54R-MC (or equivalent) -Example- Appropriate connecor (female) Model No.: HIF3BA-20D-2.54R Key ditch Socket (male) connector (joint side) 12
© Copyright 2024 ExpyDoc