Pow-R-StockPlus program reference guide

Pow-R-Stock
Pow-R-StockPlus program
reference guide
Unassembled panelboards—EZ Box and EZ Trim
Catalog Numbers
Ampere
Rating
Notee: The colors shown in the table
to the right correspond to the colorcoding on the trim, interior and box
product packaging labels. Be sure
that all three parts match when
delivering to your customer.
Maximum
Number
of Poles
Interiors (Less Main Device)
Boxes
Trims (NEMA 1)
Aluminum Bus
Copper Bus
NEMA 1
Surface
Flush
NEMA 3R
Enclosures
PRL1A1100X18C
PRL1A1100X30C
PRL1A1225X30C
PRL1A1225X42CS
PRL1A1225X42C
PRL1A1400X42C
EZB2036R
EZB2048R
EZB2048R
EZB2048R
EZB2060R
EZB2072R
EZT2036S
EZT2048S
EZT2048S
EZT2048S
EZT2060S
EZT2072S
EZT2036F
EZT2048F
EZT2048F
EZT2048F
EZT2060F
EZT2072F
GWPBQ2036PR
GWPBQ2048PR
GWPBQ2048PR
GWPBQ2048PR
GWPBQ2060PR
GWPBQ2072PR
PRL1A3100X18C
PRL1A3100X30C
PRL1A3225X30C
PRL1A3225L42CS
PRL1A3225X42CS
PRL1A3225X42C
PRL1A3400X42C
EZB2036R
EZB2048R
EZB2048R
EZB2042R
EZB2048R
EZB2060R
EZB2072R
EZT2036S
EZT2048S
EZT2048S
EZT2042S
EZT2048S
EZT2060S
EZT2072S
EZT2036F
EZT2048F
EZT2048F
EZT2042F
EZT2048F
EZT2060F
EZT2072F
GWPBQ2036PR
GWPBQ2048PR
GWPBQ2048PR
GWPBQ2042PR
GWPBQ2048PR
GWPBQ2060PR
GWPBQ2072PR
PRL2A3100X18C
PRL2A3100X30C
PRL2A3225X30C
PRL2A3225L42CS
PRL2A3225X42CS
PRL2A3225X42C
PRL2A3400X42C
EZB2036R
EZB2048R
EZB2048R
EZB2042R
EZB2048R
EZB2060R
EZB2072R
EZT2036S
EZT2048S
EZT2048S
EZT2042S
EZT2048S
EZT2060S
EZT2072S
EZT2036F
EZT2048F
EZT2048F
EZT2042F
EZT2048F
EZT2060F
EZT2072F
GWPBQ2036PR
GWPBQ2048PR
GWPBQ2048PR
GWPBQ2042PR
GWPBQ2048PR
GWPBQ2060PR
GWPBQ2072PR
Single-Phase, Three-Wire, 120/240 V
100
18
PRL1A1100X18A
100
30
PRL1A1100X30A
225
30
PRL1A1225X30A
225
42
PRL1A1225X42AS
225
42
PRL1A1225X42A
400
42
PRL1A1400X42A
Three-Phase, Four-Wire, 208Y/120 V
100
18
PRL1A3100X18A
100
30
PRL1A3100X30A
225
30
PRL1A3225X30A
225
42
PRL1A3225L42AS
225
42
PRL1A3225X42AS
225
42
PRL1A3225X42A
400
42
PRL1A3400X42A
Three-Phase, Four-Wire, 480Y/277 V
100
18
PRL2A3100X18A
100
30
PRL2A3100X30A
225
30
PRL2A3225X30A
225
42
PRL2A3225L42AS
225
42
PRL2A3225X42AS
225
42
PRL2A3225X42A
400
42
PRL2A3400X42A
Summary of branch breakers available
Breaker
Poles
Ampere
Rating
Voltage
kAIC
Rating
Example
Panel
Type
BAB
1
2
2
3
1
2
1
2
2
3
1
1
2
3
15–60
15–100
15–100
15–100
15–30
15–40
15–60
15–100
15–100
15–100
15–20
15–100
15–100
15–100
120 V
120/240 V
240 V
240 V
120 V
120/240 V
120 V
120/240 V
240 V
240 V
277 V
277 V
480Y / 277 V
480Y / 277 V
10
10
10
10
10
10
22
22
22
22
14
14
14
14
BAB1020
BAB2020
BAB2040H
BAB3030H
QBGF1020
QBGF2040
QBHW1020
QBHW2020
QBHW2040H
QBHW3030H
GHQ1020
GHB1020
GHB2040
GHB3060
PRL1a
PRL1a
PRL1a
PRL1a
PRL1a
PRL1a
PRL1a
PRL1a
PRL1a
PRL1a
PRL2a
PRL2a
PRL2a
PRL2a
QBGF
QBHW
GHQ
GHB
Circuit breaker kits—unassembled panelboards
Kits—main circuit breaker or subfeed circuit breaker
(includes circuit breaker and terminals)
Kits—main circuit breaker or subfeed circuit breaker
(includes circuit breaker and terminals)
Max.
Ampere Service Breaker Mounting Wire Range
Voltage Rating Phase Frame
Location Al/Cu
Catalog
Number
Max.
Ampere Service Breaker Mounting Wire Range
Voltage Rating Phase Frame
Location Al/Cu
240 V
BKED100T
BKED125T
BKED150T
BKED175T
BKED200T
BKED225T
BKED100B
BKED125B
BKED150B
BKED175B
BKED200B
BKED225B
BKFD100T
BKFD125T
BKFD150T
BKFD175T
BKFD200T
BKFD225T
BKFD100B
BKFD125B
BKFD150B
BKFD175B
BKFD200B
BKFD225B
BKHFD100T
BKHFD125T
BKHFD150T
BKHFD175T
BKHFD200T
BKHFD225T
BKHFD100B
BKHFD125B
BKHFD150B
BKHFD175B
BKHFD200B
BKHFD225B
480 V
250
300
350
400
1 or 3
1 or 3
1 or 3
1 or 3
KD
KD
KD
KD
Top
Top
Top
Top
480 V
250
300
350
400
1 or 3
1 or 3
1 or 3
1 or 3
KD
KD
KD
KD
Bottom
Bottom
Bottom
Bottom
480 V
250
300
350
400
1 or 3
1 or 3
1 or 3
1 or 3
KD
KD
KD
KD
Top
Top
Top
Top
480 V
250
300
350
400
1 or 3
1 or 3
1 or 3
1 or 3
KD
KD
KD
KD
Bottom
Bottom
Bottom
Bottom
240 V
480 V
480 V
480 V
480 V
100
125
150
175
200
225
100
125
150
175
200
225
100
125
150
175
200
225
100
125
150
175
200
225
100
125
150
175
200
225
100
125
150
175
200
225
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
1 or 3
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
ED
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
FD
HFD
HFD
HFD
HFD
HFD
HFD
HFD
HFD
HFD
HFD
HFD
HFD
Top
Top
Top
Top
Top
Top
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Top
Top
Top
Top
Top
Top
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
Top
Top
Top
Top
Top
Top
Bottom
Bottom
Bottom
Bottom
Bottom
Bottom
(1) #14–1/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #14–1/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #14–1/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #14–1/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #14–1/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #14–1/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
(1) #4–4/0
Catalog
Number
(1) 250–500 kcmil BKKD250T
(1) 250–500 kcmil BKKD300T
(1) 250–500 kcmil BKKD350T
(2) 3/0–250 kcmil BKKD400T
or (1) 3/0–500 kcmil
(1) 250–500 kcmil BKKD250B
(1) 250–500 kcmil BKKD300B
(1) 250–500 kcmil BKKD350B
(2) 3/0–250 kcmil BKKD400B
or (1) 3/0–500 kcmil
(1) 250–500 kcmil BKHKD250T
(1) 250–500 kcmil BKHKD300T
(1) 250–500 kcmil BKHKD350T
(2) 3/0–250 kcmil BKHKD400T
or (1) 3/0–500 kcmil
(1) 250–500 kcmil BKHKD250T
(1) 250–500 kcmil BKHKD300T
(1) 250–500 kcmil BKHKD350T
(2) 3/0–250 kcmil BKHKD400T
or (1) 3/0–500 kcmil
NNote: Order optional lug kit catalog number 3TA225FDK for 175 A to
225 A F-Frame three-pole circuit breakers to provide terminations for
(1) #6–300 kcmil.
Kits—main lugs/through-feed lugs/subfeed breaker
Ampere
Rating
Service
Phase
Wire Range
Al/Cu
Catalog
Number
100
225
400
225
1 or 3
1 or 3
1 or 3
1 or 3
(1) #14–1/0
(1) #6–300 kcmil
(2) #2–500 kcmil
NA
LUGKIT100
LUGKIT225
LUGKIT400
225ASFBKIT
Kits—service entrance
Ampere
Rating
Service
Phase
Panel Type
Catalog
Number
100/225
400
1 or 3
1 or 3
PRL1a or PRL2a
PRL1a or PRL2a
SEK1/2
SEK4/6
Kits—insulated/isolated or copper ground or series rating
(carton quantity of 5)
Ampere
Rating
Service
Phase
Panel Type
Catalog
Number
NA
NA
NA
1 or 3
1 or 3
1 or 3
PRL1a or PRL2a
PRL1a or PRL2a
PRL1a or PRL2a
ISOGROUND
CUGROUND
SRK
Kits—200% neutral
Ampere
Rating
Service
Phase
Panel Type
Catalog
Number
100
225
1 or 3
1 or 3
PRL1a or PRL2a
PRL1a or PRL2a
2NK100
2NK225
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
© 2014 Eaton
All Rights Reserved
Printed in USA
Publication No. SA01413001E / Z14690
January 2014
Eaton is a registered trademark.
All other trademarks are property