Pow-R-Stock Pow-R-StockPlus program reference guide Unassembled panelboards—EZ Box and EZ Trim Catalog Numbers Ampere Rating Notee: The colors shown in the table to the right correspond to the colorcoding on the trim, interior and box product packaging labels. Be sure that all three parts match when delivering to your customer. Maximum Number of Poles Interiors (Less Main Device) Boxes Trims (NEMA 1) Aluminum Bus Copper Bus NEMA 1 Surface Flush NEMA 3R Enclosures PRL1A1100X18C PRL1A1100X30C PRL1A1225X30C PRL1A1225X42CS PRL1A1225X42C PRL1A1400X42C EZB2036R EZB2048R EZB2048R EZB2048R EZB2060R EZB2072R EZT2036S EZT2048S EZT2048S EZT2048S EZT2060S EZT2072S EZT2036F EZT2048F EZT2048F EZT2048F EZT2060F EZT2072F GWPBQ2036PR GWPBQ2048PR GWPBQ2048PR GWPBQ2048PR GWPBQ2060PR GWPBQ2072PR PRL1A3100X18C PRL1A3100X30C PRL1A3225X30C PRL1A3225L42CS PRL1A3225X42CS PRL1A3225X42C PRL1A3400X42C EZB2036R EZB2048R EZB2048R EZB2042R EZB2048R EZB2060R EZB2072R EZT2036S EZT2048S EZT2048S EZT2042S EZT2048S EZT2060S EZT2072S EZT2036F EZT2048F EZT2048F EZT2042F EZT2048F EZT2060F EZT2072F GWPBQ2036PR GWPBQ2048PR GWPBQ2048PR GWPBQ2042PR GWPBQ2048PR GWPBQ2060PR GWPBQ2072PR PRL2A3100X18C PRL2A3100X30C PRL2A3225X30C PRL2A3225L42CS PRL2A3225X42CS PRL2A3225X42C PRL2A3400X42C EZB2036R EZB2048R EZB2048R EZB2042R EZB2048R EZB2060R EZB2072R EZT2036S EZT2048S EZT2048S EZT2042S EZT2048S EZT2060S EZT2072S EZT2036F EZT2048F EZT2048F EZT2042F EZT2048F EZT2060F EZT2072F GWPBQ2036PR GWPBQ2048PR GWPBQ2048PR GWPBQ2042PR GWPBQ2048PR GWPBQ2060PR GWPBQ2072PR Single-Phase, Three-Wire, 120/240 V 100 18 PRL1A1100X18A 100 30 PRL1A1100X30A 225 30 PRL1A1225X30A 225 42 PRL1A1225X42AS 225 42 PRL1A1225X42A 400 42 PRL1A1400X42A Three-Phase, Four-Wire, 208Y/120 V 100 18 PRL1A3100X18A 100 30 PRL1A3100X30A 225 30 PRL1A3225X30A 225 42 PRL1A3225L42AS 225 42 PRL1A3225X42AS 225 42 PRL1A3225X42A 400 42 PRL1A3400X42A Three-Phase, Four-Wire, 480Y/277 V 100 18 PRL2A3100X18A 100 30 PRL2A3100X30A 225 30 PRL2A3225X30A 225 42 PRL2A3225L42AS 225 42 PRL2A3225X42AS 225 42 PRL2A3225X42A 400 42 PRL2A3400X42A Summary of branch breakers available Breaker Poles Ampere Rating Voltage kAIC Rating Example Panel Type BAB 1 2 2 3 1 2 1 2 2 3 1 1 2 3 15–60 15–100 15–100 15–100 15–30 15–40 15–60 15–100 15–100 15–100 15–20 15–100 15–100 15–100 120 V 120/240 V 240 V 240 V 120 V 120/240 V 120 V 120/240 V 240 V 240 V 277 V 277 V 480Y / 277 V 480Y / 277 V 10 10 10 10 10 10 22 22 22 22 14 14 14 14 BAB1020 BAB2020 BAB2040H BAB3030H QBGF1020 QBGF2040 QBHW1020 QBHW2020 QBHW2040H QBHW3030H GHQ1020 GHB1020 GHB2040 GHB3060 PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL1a PRL2a PRL2a PRL2a PRL2a QBGF QBHW GHQ GHB Circuit breaker kits—unassembled panelboards Kits—main circuit breaker or subfeed circuit breaker (includes circuit breaker and terminals) Kits—main circuit breaker or subfeed circuit breaker (includes circuit breaker and terminals) Max. Ampere Service Breaker Mounting Wire Range Voltage Rating Phase Frame Location Al/Cu Catalog Number Max. Ampere Service Breaker Mounting Wire Range Voltage Rating Phase Frame Location Al/Cu 240 V BKED100T BKED125T BKED150T BKED175T BKED200T BKED225T BKED100B BKED125B BKED150B BKED175B BKED200B BKED225B BKFD100T BKFD125T BKFD150T BKFD175T BKFD200T BKFD225T BKFD100B BKFD125B BKFD150B BKFD175B BKFD200B BKFD225B BKHFD100T BKHFD125T BKHFD150T BKHFD175T BKHFD200T BKHFD225T BKHFD100B BKHFD125B BKHFD150B BKHFD175B BKHFD200B BKHFD225B 480 V 250 300 350 400 1 or 3 1 or 3 1 or 3 1 or 3 KD KD KD KD Top Top Top Top 480 V 250 300 350 400 1 or 3 1 or 3 1 or 3 1 or 3 KD KD KD KD Bottom Bottom Bottom Bottom 480 V 250 300 350 400 1 or 3 1 or 3 1 or 3 1 or 3 KD KD KD KD Top Top Top Top 480 V 250 300 350 400 1 or 3 1 or 3 1 or 3 1 or 3 KD KD KD KD Bottom Bottom Bottom Bottom 240 V 480 V 480 V 480 V 480 V 100 125 150 175 200 225 100 125 150 175 200 225 100 125 150 175 200 225 100 125 150 175 200 225 100 125 150 175 200 225 100 125 150 175 200 225 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 1 or 3 ED ED ED ED ED ED ED ED ED ED ED ED FD FD FD FD FD FD FD FD FD FD FD FD HFD HFD HFD HFD HFD HFD HFD HFD HFD HFD HFD HFD Top Top Top Top Top Top Bottom Bottom Bottom Bottom Bottom Bottom Top Top Top Top Top Top Bottom Bottom Bottom Bottom Bottom Bottom Top Top Top Top Top Top Bottom Bottom Bottom Bottom Bottom Bottom (1) #14–1/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #14–1/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #14–1/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #14–1/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #14–1/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #14–1/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 (1) #4–4/0 Catalog Number (1) 250–500 kcmil BKKD250T (1) 250–500 kcmil BKKD300T (1) 250–500 kcmil BKKD350T (2) 3/0–250 kcmil BKKD400T or (1) 3/0–500 kcmil (1) 250–500 kcmil BKKD250B (1) 250–500 kcmil BKKD300B (1) 250–500 kcmil BKKD350B (2) 3/0–250 kcmil BKKD400B or (1) 3/0–500 kcmil (1) 250–500 kcmil BKHKD250T (1) 250–500 kcmil BKHKD300T (1) 250–500 kcmil BKHKD350T (2) 3/0–250 kcmil BKHKD400T or (1) 3/0–500 kcmil (1) 250–500 kcmil BKHKD250T (1) 250–500 kcmil BKHKD300T (1) 250–500 kcmil BKHKD350T (2) 3/0–250 kcmil BKHKD400T or (1) 3/0–500 kcmil NNote: Order optional lug kit catalog number 3TA225FDK for 175 A to 225 A F-Frame three-pole circuit breakers to provide terminations for (1) #6–300 kcmil. Kits—main lugs/through-feed lugs/subfeed breaker Ampere Rating Service Phase Wire Range Al/Cu Catalog Number 100 225 400 225 1 or 3 1 or 3 1 or 3 1 or 3 (1) #14–1/0 (1) #6–300 kcmil (2) #2–500 kcmil NA LUGKIT100 LUGKIT225 LUGKIT400 225ASFBKIT Kits—service entrance Ampere Rating Service Phase Panel Type Catalog Number 100/225 400 1 or 3 1 or 3 PRL1a or PRL2a PRL1a or PRL2a SEK1/2 SEK4/6 Kits—insulated/isolated or copper ground or series rating (carton quantity of 5) Ampere Rating Service Phase Panel Type Catalog Number NA NA NA 1 or 3 1 or 3 1 or 3 PRL1a or PRL2a PRL1a or PRL2a PRL1a or PRL2a ISOGROUND CUGROUND SRK Kits—200% neutral Ampere Rating Service Phase Panel Type Catalog Number 100 225 1 or 3 1 or 3 PRL1a or PRL2a PRL1a or PRL2a 2NK100 2NK225 Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com © 2014 Eaton All Rights Reserved Printed in USA Publication No. SA01413001E / Z14690 January 2014 Eaton is a registered trademark. All other trademarks are property of their respective owners.
© Copyright 2024 ExpyDoc