REPORT No. 200010961UDI-IEC

TEST REPORT
REPORT No. 200010961UDI-IEC
Operator:
Giovanni DEL NEGRO
Report Verified:
Massimiliano DARIO
Date of issue:
30 January 2014
Total pages
6
Revision
0
This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.
Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any
party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the
Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in
writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does
not imply that the material, product, or service is or has ever been under an Intertek certification program
INTERTEK ITALIA SPA
Via Principe di Udine,114 - 33030 Campoformido (UD)
Tel : +39 0432 653411
Fax: +39 0432 653499
INTERTEK ITALIA SPA
Report No. 200010961UDI-ETL
Via Principe di Udine, 114
33030 Campoformido (UD) – Italy
Tel. +39 0432 653411 - Fax +39 0432 653499
pag. 2 (6)
CONTENTS
1. IDENTIFICATIONS
1.1 Customer identification
1.2 Product identification
2. CUSTOMER REQUEST
3. TESTS PERFORMED
3.1 Protection against solid foreign objects (first characteristic numeral 6 –
Dust tight)
3.1.1 Test method
3.1.2 Test results
3.2 Protection against water (second characteristic numeral 8 – Protected
against the effects of continuous immersion in water)
3.2.1 Test method
3.2.2 Test results
4. EQUIPMENT USED
5. PHOTOS OF THE PRODUCTS TESTED
200010961UDI-IEC.DOC
Date of issue: 30 January 2014
INTERTEK ITALIA SPA
Report No. 200010961UDI-ETL
Via Principe di Udine, 114
33030 Campoformido (UD) – Italy
Tel. +39 0432 653411 - Fax +39 0432 653499
pag. 3 (6)
1. IDENTIFICATIONS
1.1 CUSTOMER IDENTIFICATION
Company name:
VIVAX ITALIA SRL
Company address:
Via Nepal 56
00144 ROMA
Italy
Name of reference person:
Mattia VENTURA
Telephone:
(+39) 334 137 2150
Email:
[email protected]
1.2 PRODUCT IDENTIFICATION
Product:
Laptop case
Model:
VIVAX
Intertek ID
UDI1401091342-001
UDI1401091342-002
Sample Tested:
2
Sample Conditions:
as furnished
Test Conditions
20 °C; 48 % R.H.
Dates of evaluation:
28-30 January 2014
2. CUSTOMER REQUEST
Verification of IP 68 grade according to the standard:
IEC/EN 60529:1991 + A1:2000 – Degrees of protection provide by enclosure (IP Code)
200010961UDI-IEC.DOC
Date of issue: 30 January 2014
INTERTEK ITALIA SPA
Report No. 200010961UDI-ETL
Via Principe di Udine, 114
33030 Campoformido (UD) – Italy
Tel. +39 0432 653411 - Fax +39 0432 653499
pag. 4 (6)
3. TESTS PERFORMED
3.1 Protection against solid foreign objects (first characteristic numeral 6 –
Dust tight)
3.1.1 Test method
According to clauses 13.4 and 13.6 of EN 60529:1991 + A1:2000;
Appliance is placed suspended in a dust chamber filled with talcum powder capable to pass through a
square meshed sieve the nominal wire diameter of which is 50 µm and the nominal width of a gap
between wires is 75 µm.
The suction hose is connected to the predisposed pipe fixed on the appliance to provide the required
depression inside the appliance.
The volume of the appliance is calculated.
The value of depression applied shall draw into the enclosure of appliance a volume of air of 80 times
the appliance volume without exceeding the extraction rate of 60 volumes per hour. In no case the
depression shall exceed 20 mbar. For an extraction rate from 40 to 60 volumes per hour, the test
duration shall be 2 hours. For an extraction rate less than 40 volumes per hour, the test continues until
80 volumes of air are extracted or until 8 hours are elapsed.
At the end of the test shall be no evidence of deposit of dust inside the enclosure of appliance.
3.1.2 Test results
Model
Appliance
volume
Depression
Duration
of test
Dust inside
enclosure
Result
VIVAX
6,16 dm3
20 mbar
8 hours
No
PASS
3.2 Protection against water (second characteristic numeral 8 – Protected
against the effects of continuous immersion in water)
3.2.1 Test method
According to clauses 14.2.8 and 14.3 of EN 60529:1991 + A1:2000;
The test is made by completely immersing the enclosure in water in its service position as specified by
the manufacturer so that the following conditions are satisfied:
a) the equipment under test is located 2 000 mm below the surface of the water;
c) the duration of the test is 24 Hours;
d) the water temperature does not differ from that of the equipment by more than 5 K.
At the end of the test shall be no evidence of ingress of water inside the enclosure of appliance.
3.2.2 Test results
Model
Depth of
immersion
Duration of test
Water inside
enclosure
Result
VIVAX
2000 mm
24 hours
No
PASS
200010961UDI-IEC.DOC
Date of issue: 30 January 2014
INTERTEK ITALIA SPA
Report No. 200010961UDI-ETL
Via Principe di Udine, 114
33030 Campoformido (UD) – Italy
Tel. +39 0432 653411 - Fax +39 0432 653499
pag. 5 (6)
4. EQUIPMENT USED
Instrument
Manufacturer
Model
Model ID
Calibration due
Dirt chamber
Galbusera
03.02-C
1147
20 Jun. 2014
Aprochimide
HM 4
---
---
IP X8 device
Galbusera
Art. 03.28-C
1391
24 Nov. 2014
Chronometer
Quantum
--
1071
30 Jun. 2014
PCE Group
PCE-HT110
1383
25 Jul. 2014
Talcum powder
Humidity/Temperatur
e Data Recorder
200010961UDI-IEC.DOC
Date of issue: 30 January 2014
INTERTEK ITALIA SPA
Via Principe di Udine, 114
33030 Campoformido (UD) – Italy
Tel. +39 0432 653411 - Fax +39 0432 653499
Report No. 200010961UDI-ETL
pag. 6 (6)
5. PHOTOS OF PRODUCTS TESTED
200010961UDI-IEC.DOC
Date of issue: 30 January 2014