SpecLink-E Catalog Listing As Of: January, 2015 Total Sections: 657 DIVISION 23 23 0130.51 - BSD 23 0513 - BSD 23 0516 - BSD 23 0519 - BSD 23 0533 - BSD 23 0548 - BSD A = Architectural; S = Structural; C = Civil; L = Landscape; ME = Mechanical / Electrical; DC, # = Design Criteria; ++ = Checklist HEATING, VENTILATING, AND AIR-CONDITIONING (HVAC) 23 0553 - BSD 23 0593 - BSD 23 0713 - BSD 23 0716 - BSD 23 0719 - BSD 23 0800 - BSD 23 0913 - BSD 23 0923 - BSD 23 0943 - BSD 23 0993 - BSD 23 1113 - BSD 23 2113 - BSD 23 2113.33 - BSD 23 2114 - BSD 23 2123 - BSD 23 2213 - BSD 23 2214 - BSD 23 2300 - BSD 23 2500 - BSD 23 3100 - BSD 23 3300 - BSD 23 3319 - BSD 23 3413 - BSD 23 3416 - BSD 23 3423 - BSD 23 3433 - BSD 23 3514 - BSD 23 3516 - BSD HVAC Air Duct Cleaning Common Motor Requirements for HVAC Equipment Expansion Fittings and Loops for HVAC Piping Meters and Gages for HVAC Piping Heat Tracing for HVAC Piping Vibration and Seismic Controls for HVAC Piping and Equipment Identification for HVAC Piping and Equipment Testing, Adjusting, and Balancing for HVAC Duct Insulation HVAC Equipment Insulation HVAC Piping Insulation Commissioning of HVAC Instrumentation and Control Devices for HVAC Direct-Digital Control System for HVAC Pneumatic Control System for HVAC Sequence of Operations for HVAC Controls Facility Fuel-Oil Piping Hydronic Piping Ground-Loop Heat-Pump Piping Hydronic Specialties Hydronic Pumps Steam and Condensate Heating Piping Steam and Condensate Heating Specialties Refrigerant Piping HVAC Water Treatment HVAC Ducts and Casings Air Duct Accessories Duct Silencers Axial HVAC Fans Centrifugal HVAC Fans HVAC Power Ventilators Air Curtains Dust Collection Equipment Engine Exhaust Systems 23 3600 - BSD Air Terminal Units 23 3700 - BSD Air Outlets and Inlets Catalog Updated ++ Duct and equipment cleaning; testing and inspection. Electric motors and accessories normally supplied as part of HVAC equipment. Fittings and practices to compensate for thermal expansion and other movement. Fixed measuring devices showing local indication of conditions. Electric heat tracing for HVAC piping. Inertia bases and vibration isolators for equipment; seismic restraints. AME ME ME ME ME ME Jul 2014 Aug 2012 Aug 2014 Mar 2014 NEW Aug 2013 Field-installed nameplates, labels; piping identification. ++ Air and water systems testing, adjusting, and balancing. Thermal and acoustic insulation; jackets; for ducts and air handling devices. Thermal insulation; jackets; accessories. Thermal insulation; jackets; accessories. Scope, objectives, procedures, Contractor's responsibilities. Devices normally found in pneumatic, digital, and electric control systems. Components and software for a direct digital HVAC control system. All types of devices normally found in a complete pneumatic control system. To be used for description of overall operation, coordinating all HVAC sections. Tanks, piping, fittings, pumps, and valves. Heating, glycol, chilled water, condenser water, and engine exhaust piping systems. ++ Ground-coupled heat exchangers; polyethylene or copper piping. Expansion tanks; air vents; relief valves; strainers; flow indicators; air separators; etc. Centrifugal pumps and accessories normally encountered in hydronic systems. Pipe materials, fittings, and valves normally encountered. Traps; air vents; tanks; boiler feed units; condensate return pumps; valves; etc. Piping and piping specialties normally found in built-up refrigerant systems. Equipment/materials for cleaning and treating HVAC hydronic and steam systems. Materials, construction, supports, cleaning; no seismic requirements. Control, smoke, and fire dampers; access doors, test holes, air turning devices. Duct and cross-talk silencers, acoustic housings, duct lagging, acoustical louvers. Vaneaxial, tubeaxial, propeller; motors and drives. Backward inclined, forward curved, airfoil, radial, tubular, inline; motors and drives. Roof and wall exhausters; cabinet and ceiling exhaust fans. For door and window openings to reduce heating/cooling losses, wind gusts, pests. Equipment, ducts, and accessories; complete system. Ductwork, fittings and equipment; complete system for motor vehicle tailpipe exhaust in enclosed vehicle maintenance areas. "#1" for products and materials specified in SpecLink-E can be found on the BSD website under "#2." For #3. Roof, wall, floor diffusers; registers, grilles, louvers; louvered penthouses; roof hoods. ME ME ME ME ME AME ME ME ME ME CME ME ACME ME ME ME ME ME ME ME ME ME ME ME ME ME ME ME Aug 2012 Dec 2014 Dec 2014 Jul 2014 Oct 2014 Oct 2012 Aug 2014 Nov 2012 Feb 2012 Nov 2014 Nov 2014 Oct 2014 Mar 2014 Apr 2014 Jan 2014 Oct 2014 Nov 2014 Nov 2014 Apr 2012 Dec 2014 Dec 2014 Jun 2014 Dec 2014 Dec 2014 Mar 2014 Feb 2010 Dec 2014 Dec 2014 ME Dec 2014 ME Dec 2014 SpecLink-E Catalog Listing As Of: January, 2015 Total Sections: 657 A = Architectural; S = Structural; C = Civil; L = Landscape; ME = Mechanical / Electrical; DC, # = Design Criteria; ++ = Checklist 23 3813 - BSD 23 4000 - BSD 23 5100 - BSD 23 5213 - BSD 23 5216 - BSD Commercial-Kitchen Hoods HVAC Air Cleaning Devices Breechings, Chimneys, and Stacks Electric Boilers Condensing Boilers 23 5223 - BSD 23 5233.13 - BSD 23 5233.16 - BSD 23 5239.13 - BSD 23 5400 - BSD 23 5533 - BSD 23 5613.13 - BSD 23 5700 - BSD 23 6100 - BSD 23 6213 - BSD Cast-Iron Boilers Finned Water-Tube Boilers Steel Water-Tube Boilers Scotch Marine Boilers Furnaces Fuel-Fired Unit Heaters Heating Solar Flat-Plate Collectors Heat Exchangers for HVAC Refrigerant Compressors Packaged Air-Cooled Refrigerant Compressor and Condenser Units Air Cooled Refrigerant Condensers Absorption Water Chillers Centrifugal Water Chillers Scroll Water Chillers Rotary-Screw Water Chillers Modular Water Chillers Forced-Draft Cooling Towers Natural-Draft Cooling Towers Ejector Cooling Towers Liquid Coolers Packaged Air-to-Air Energy Recovery Units Modular Central-Station Air-Handling Units Packaged Outdoor Central-Station Air-Handling Units Packaged Outdoor Heating and Cooling Make-Up Air Units Terminal Heat Transfer Units Packaged Terminal Air-Conditioners Self-Contained Air-Conditioners Computer Room Air Conditioners - Floor Mounted Computer Room Air Conditioners - Ceiling Mounted Small Split-System Heating and Cooling Variable Refrigerant Volume (VRV) HVAC System Basis of Design VRV Equipment Water-to-Water Heat Pumps 23 6313 - BSD 23 6413 - BSD 23 6416 - BSD 23 6423 - BSD 23 6426 - BSD 23 6429 - BSD 23 6513 - BSD 23 6516 - BSD 23 6522 - BSD 23 6533 - BSD 23 7223 - BSD 23 7313 - BSD 23 7413 - BSD 23 7433 - BSD 23 8101 - BSD 23 8113 - BSD 23 8119 - BSD 23 8124 - BSD 23 8125 - BSD 23 8127 - BSD 23 8129 - BSD 23 8130 - DAIKN 23 8149 - BSD Grease extracting, grease filter, condensate type; duct connections; fire extinguishing. Air filters and air cleaning devices. Built-up and manufactured products; vent dampers; induced draft fans. Packaged hot water/steam boilers; controls. Packaged hot water; trim; fuel burning system; controls; natural gas, propane, or fuel oil; indoor or outdoor. Packaged boilers, controls, and boiler trim accessories; hot water/steam generation. Packaged hot water boilers, controls, and accessories. Packaged hot water/steam; power burners; controls; natural gas, propane, fuel oil. Oil/gas fire-tube boilers, boiler trim, and connections. Gas, oil, and electric; with optional economizer, humidifiers, air cleaners. Unit heaters, industrial heaters, duct furnaces, infrared heaters; packaged units. Collectors, controls, pumps, valves, chemical treatment. Shell and tube type; plate type; common accessories. Packaged compressors; controls and motor starters. Outdoor; enclosure, refrigerant compressors, condensing coils and fans, controls. AME ME ME ME ME Dec 2014 Jun 2014 Dec 2014 Apr 2014 Apr 2014 ME ME ME ME ME ME ME ME ME ME Mar 2014 Apr 2014 Jul 2014 Jul 2014 Mar 2014 Mar 2014 Nov 2014 Apr 2014 May 2014 May 2014 Packaged condensers, controls, starters, connections. Packaged; lithium bromide refrigerant; gas/oil/steam/hot water heat source; controls. Packaged centrifugal compressor, water cooled condenser. Packaged, water/air-cooled scroll type; for indoor and outdoor use. Packaged, water/air-cooled rotary screw type; for indoor and outdoor use. Packaged, water/air-cooled modular type; for indoor and outdoor use. Steel, blow-through; fan, fill, controls; framework, safety railing, ladder. Wood, steel, fiberglass; fans, fill, controls; framework, safety railing, ladder. Packaged, steel, parallel flow, blow-through, water injection process; controls. Packaged liquid coolers using evaporative cooling; circulating pump; accessories. Dessicant wheel type. Modular packaged units; coils, mixing boxes, filters, dampers, humidifiers. Self-contained; electric cooling; gas, electric, or heat pump heating; controls. Gas fired make-up air units; integrated air-cooled refrigeration; indoor and outdoor. For hydronic and steam heating systems; electric heaters. Packaged indoor refrigerant units; water cooled or external air cooled condenser. Free standing or through-the-wall; air conditioning and heat pump units; controls. Floor mounted units specifically designed for computer rooms. Ceiling mounted units specifically designed for computer rooms. ++ Matched indoor/outdoor units; furnace, AC, air-/water-source heat pumps. Highly efficient heat pump and heat recovery systems; long piping runs possible. Daikin AC VRV Equipment; outdoor/condensers, indoor/evaporators. ++ Water source heat pumps with refrigerant-to-water condensers and evaporators. ME ME ME ME ME ME ME ME ME ME ME ME Free ME ME ME ME ME ME ME ME ME ME May 2014 Apr 2014 Jun 2014 Jun 2014 Jul 2014 Jun 2014 Nov 2014 Nov 2014 Mar 2014 Aug 2014 Oct 2014 Dec 2014 Jun 2014 Jun 2014 Jan 2014 May 2014 Jun 2014 Jun 2014 Jun 2014 May 2014 May 2014 Nov 2011 Jul 2014 SpecLink-E Catalog Listing As Of: January, 2015 Total Sections: 657 23 8200 - BSD 23 8216 - BSD 23 8300 - BSD 23 8313 - BSD 23 8413 - BSD 23 8414 - BSD 23 8415 - BSD 23 8417 - BSD A = Architectural; S = Structural; C = Civil; L = Landscape; ME = Mechanical / Electrical; DC, # = Design Criteria; ++ = Checklist Convection Heating and Cooling Units Air Coils Radiant Heating Units Radiant-Heating Cables Humidifiers Evaporative Pan Humidifiers Steam Humidifiers Sprayed Coil Dehumidifiers Terminal units with water, steam, electric, and refrigerant coils. Air system coils; water, glycol/water, steam, and halon; electric heating coils. Hydronic and electric radiant heating units. Electric; for snow melting, heat tracing, etc. Wetted media humidifiers and evaporative coolers; for installation in equipment. Heated pan humidifiers using hot water, steam, or electricity for heat source. External steam sources are any steam generating system. Packaged; for central air handling units; optional spray pumps. ME ME ME ME ME ME ME ME Dec 2014 Dec 2014 Jul 2014 Jun 2014 Nov 2010 Nov 2010 Nov 2010 Dec 2014
© Copyright 2024 ExpyDoc