862075-XTG-F-0513 ® TECHNICAL GUIDE R-410A ZF SERIES 7-1/2 THRU 12-1/2 TON 50 Hz (Export) Description ASHRAE 90.1 COMPLIANT YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 7-1/2 through 12-1/2 ton models. All units have two compressors with independent refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Predator® units are available in the following configurations: cooling only, cooling with electric heat, and cooling with gas heat. Electric heaters are available as factory-installed options or field-installed accessories. ZF 7-1/2 AND 10 TON All units provide constant supply air volume. ZF 12-1/2 TON FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 862075-XTG-F-0513 Table of Contents Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Capacity Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Sound Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Typical Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Economizer Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Component Location Cooling With Gas Heat Simplicity® control board Filter Access Disconnect location w/screw connector for T-stat (2” or 4” filter options) Filter drier (solid core) wiring and network connections (optional disconnect switch) ZF Series utilize Micro-Channel Aluminum Tube/Aluminum Fin Condenser Terminal block for hi-voltage connection Second model nameplate inside hinged access panel Slide-out motor and blower assembly for easy adjustment and service Dual stage cooling for maximum comfort Power ventor motor Compressor #2 access (highefficiency compressor w/crankcase heater) 20-gauge aluminized steel tubular heat exchanger for long life (stainless steel option) Base rails w/forklift slots (three sides) and lifting holes Two-stage gas heating to maintain warm, comfortable temperature Roof curbs in eight- and fourteen-inch heights. Roof curbs for transitioning from York Sunline™ footprint to the ZF Series footprints are also available (field installed accessory) 2 Belt-drive blower motor Slide-out drain pan with 3/4” NPT, female connection Toolless door latch Side entry power and control wiring knockouts Intelligent control board for safe and efficient operation Compressor #1 access (high-efficiency compressor w/crankcase heater) Johnson Controls Unitary Products 862075-XTG-F-0513 Nomenclature 7.5-12.5 Ton York® Model Number Nomenclature Z F 090 N10 A 7 A AA 5 0 1 2 4 A Product Category Product Style Z = A/C, Single Pkg., R410A A = Style A Product Identifier Configuration Options (not required for all units) These four digits will not be assigned until a quote is requested, or an order placed. F = 11.2 EER 7.5 & 10 Ton A/C 11.0 EER 12.5 Ton A/C SS Drain Pan Honeywell Controller, DFS, APS Simplicity IntelliComfort Controller Nominal Cooling Capacity Simplicity IntelliComfort Controller w/ModLinc 090 = 7.5 Ton 120 = 10.0 Ton 150 = 12.5 Ton 2" Pleated Filters, MERV 7 4" Pleated Filters, MERV 13 BAS Ready Unit with Belimo Economizer Shipping Bag Heat Type and Nominal Heat Capacity Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned C00 = Cooling Only. No heat installed Gas Heat Options* N10 = 100 MBH Output Aluminized Steel N15 = 150 MBH Output Aluminized Steel N20 = 200 MBH Output Aluminized Steel S10 = 100 MBH Output Stainless Steel S15 = 150 MBH Output Stainless Steel S20 = 200 MBH Output Stainless Steel * N10/S10 Not Available on ZF120/150 Electric Heat Options* E18 = 18 KW E24 = 24 KW E36 = 36 KW E54 = 54 KW * No Electric Heat Options for ZF090 Airflow A = Std. Motor B = Std. Motor/Econo./Barometric Relief (Downflow Only) C = Std. Motor/Econo./Power Exhaust (Downflow Only) D = Std. Motor/Motorized Damper (Downflow Only) E = Std. Motor/Horizontal Economizer (No Baro.) F = Std. Motor/Slab Econo./Power Exhaust (Downflow Only) G = Std. Motor/Slab Econo./Barometric Relief (Downflow Only) N = Hi Static Mtr.** P = Hi Static Mtr./Econo./Barometric Relief (Downflow Only) Q = Hi Static Mtr./Econo./Power Exhaust (Downflow Only) R = Hi Static Mtr./Motorized Damper (Downflow Only) S = Hi Static Mtr./Horizontal Economizer (No Baro.) T = Hi Static Mtr./Slab Econo./Power Exhaust (Downflow Only) U = Hi Static Mtr./Slab Econo./Barometric Relief (Downflow only) ** Only Hi Static Is Offered On ZF150 Johnson Controls Unitary Products Product Generation 5 = Fifth Generation Additional Options AA = None AB = Phase Monitor AC = Coil Guard AD = Dirty Filter Switch AE = Phase Monitor & Coil Guard AF = Phase Monitor & Dirty Filter Switch AG = Coil Guard & Dirty Filter Switch AH = Phase Monitor, Coil Guard & Dirty Filter Switch RC = Coil Guard & American Flag TA = Technicoat Condenser Coil TJ = Technicoat Evaporator Coil TS = Technicoat Evaporator & Condenser Coils EA = ElectroFin Condenser Coil EJ = ElectroFin Evaporator Coil ES = ElectroFin Cond & Evap Coils ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18. Installation Options A = No Options Installed B = Option 1 E = Option 3 F = Option 4 G = Options 1 & 3 H = Options 1 & 4 L = Options 1,3 & 4 R = Options 3 & 4 Options 1 = Disconnect 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. Voltage 7 = 380/415-3-50 3 862075-XTG-F-0513 Features and Benefits Standard Features • High Efficiency – High efficiency units reach as high as 11.2 EER. Gas/electric units have electronic spark ignition and power vented combustion with steady state efficiencies of 80%. These efficiencies exceed all legislated minimum levels and provide low operating costs. • Service Friendly – The Predator® incorporates a number of enhancements which improve serviceability. The motor and blower slide out of the unit as a common assembly. This facilitates greater access to all the indoor airflow components, thus simplifying maintenance and adjustment. Service time is reduced through the use of hinged, toolless panels. Such panels provide access to frequently inspected components and areas, including the control box, compressors, filters, indoor motor & blower, and the heating section. The panels are screwed in place at the factory to prevent access by children or other unauthorized persons. It is recommended that the panels be secured with screws once service is complete. Service windows have been placed in both condenser section walls. Rotation of the cover allows easy access to the condenser coils for cleaning or inspection. Both the unit control board and ignition control board utilize flash codes to aid in diagnosis of unit malfunctions. Unique alarm codes quickly identify the source of the unit alarm. All units use the same standard filter size. This standardization removes any confusion on which filter sizes are needed for replacement. The non-corrosive drain pan slides out of the unit to permit easy cleaning. The drain pan is accessed by removing the drain pan cover plate on the rear of the unit. Once the plate is removed, the drain pan slides out through the rear of the unit. All Predator® units have a second model nameplate located inside the control access door. This is to prevent deterioration of the nameplate through weathering. • Coil Technology – ZF condensers utilize Micro-Channel “all aluminum” condensers which provide improved heat transfer capabilities and reduced charge volumes. • Environmentally Aware – For improved Indoor Air Quality, a combination of foil faced and elastometric rubber insulation is used exclusively throughout the units. • Balanced Heating – The Predator® offers “Ultimate Heating Comfort” with a balance between 1st and 2nd stage gas heating. The first stage of a gas heat Predator® unit provides 60% of the heating capacity. Balanced heating allows the unit to better maintain desired temperatures. • Convertible Airflow Design – The side duct openings are covered when they leave the factory. If a side supply/ return is desired, the installer simply removes the two side duct covers from the outside of the unit and installs them over the down shot openings. No panel cutting is required. Convertible airflow design allows maximum field flexibility and minimum inventory. • System Protection - Suction line freezestats are supplied on all units to protect against loss of charge and coil frosting 4 • when the economizer operates at low outdoor air temperatures while the compressors are running. Every unit has solid-core liquid line filter-driers and high and lowpressure switches. Internal compressor protection is standard on all compressors. Crankcase heaters are standard on reciprocating compressors. Scroll compressors do not require crankcase heaters. Phase Monitors are standard on units with scroll compressors. This accessory monitors the incoming power to the unit and protects the unit from phase loss and reversed phase rotation. Advanced Controls - Simplicity® control boards have standardized a number of features previously available only as options or by utilizing additional controls. • Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0F outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. The Simplicity® control board used in this product will effectively operate the cooling system down to 0°F when this product is applied in a comfort cooling application for people. An economizer is typically included in this type of application. When applying this product for process cooling applications (computer rooms, switchgear, etc.), please reference applications bulletin AE-011-07 or call the applications department for Unitary Products @ 1-877UPG-SERV for guidance. Additional accessories may be needed for stable operation at temperatures below 30° F. • Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti-short cycle delay can be temporarily overridden with the push of a button. • Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. • Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor. Johnson Controls Unitary Products 862075-XTG-F-0513 • On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. • Reliable – From the beginning – All units undergo computer automated testing before they leave the factory. Units are tested for refrigerant charge and pressure, unit amperage, and 100% functionality. For the long term – All Predator® units are painted with a long lasting, powder paint that stands up over the life of the unit. The paint used has been proven by a 1000 hour salt spray test. • Flexible Placement – All models and configurations share the same cabinet/footprint and thus the same roof curb. You have the flexibility to set one curb and choose the correct tonnage size and heating option after the internal loads have been determined. To further simplify planning and installation, Predator® ZF cabinets are designed to fit your roof. With the optional roof curb, the unit ductwork is designed to fit around 24” on-center joists or between 48” on-center joists. The drain pan can be rotated to drain to either the front or the rear of the unit. Additionally, the drain pan can be fitted to drain through the roof curb. As it is sometimes difficult to have a level installation, the drain pan features a generous slope to ensure proper drainage. • Full Perimeter Base Rails – The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails offer forklift access from 3 sides, and rigging holes are available so that an overhead crane can be used to place the units on a roof. • Easy Installation – Gas and electric utility knockouts are supplied in the unit underside as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. All units are shipped with 2” throw-away filters installed. • Wide Range of Indoor Airflows – All indoor fan motors are belt-drive type providing maximum flexibility to handle most airflow requirements. For high static applications, factory installed alternate indoor fan motors are available. With the optional indoor fan motor, all units can supply nominal airflow at a minimum of 1.5” ESP. • Warranty - All models include a 1-year limited warranty on the complete unit. Compressors and electric heater elements each carry a 5-year warranty. Aluminized steel and stainless steel tubular heat exchangers carry a 10year warranty. Factory Installed Options YORK® offers several equipment options factory installed, for the Predator®line. • Optional Factory Installed Economizers - Predator units offer a variety of optional factory installed economizers with low leak dampers. The outdoor air enthalpy sensor Johnson Controls Unitary Products enables economizer operation if the outdoor enthalpy is less than the setpoint of the economizer logic module. See economizer options section to determine the correct economizer for your application. • Downflow Economizer - (With barometric relief) The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type, and is shipped installed and wired. The installer needs only to assemble and mount the outdoor air hood (Provided). The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. • Horizontal Economizer - (Without barometric relief) All features of the downflow economizer exist except you must order the duct mount barometric relief separately. You must order a 1EH0408 if you are installing a power exhaust. You can order a 1RD0411 Barometric Relief for horizontal flow economizers only. • BAS Ready Economizer -(With barometric relief) The economizer is provided with an actuator that requires a 2-10V DC input from an external source (i.e., field installed building automation system controller). Power exhaust options are available. The economizer is 2% low leakage type with spring return and fully modulating dampers capable of introducing up to 100% outside air. Also include 2” pleated filters. BAS Ready actuators have an adjustable auxiliary end-switch for optional power exhaust control. For units with Simplicity® INTELLI-Comfort II™ control, a factory-installed, dry bulb sensor determines if outdoor air temperature is low enough to provide free-cooling operation. (Field-installed humidity sensors for either outdoor air or outdoor & return air streams are available for single enthalpy and differential enthalpy configurations respectively). •Slab Economizer for Energy Recovery Ventilators(With barometric relief and Fresh Air Hood) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type, and is shipped installed and wired. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand 5 862075-XTG-F-0513 • • • • • • • • • • ventilation.With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. Power Exhaust (Downflow only) - This accessory installs in the unit with a down flow economizer. Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory. Alternate Indoor Blower Motor - For applications with high static restrictions, units are offered with optional indoor motors that provide higher static output and/or higher airflow, depending upon the installer’s needs. Aluminized Steel Gas Heat Exchanger - For applications in non-corrosive environments. Stainless Steel Gas Heat Exchanger - For applications in corrosive environments, this option provides a full stainless steel heat exchanger assembly. Stainless Steel Drain Pan - An optional rust-proof stainless steel drain pan is available to provide years of trouble-free operation in corrosive environments. Electric Heaters (10 & 12.5 Ton Only) - The electric heaters range from 18KW to 54kW and are available in all the voltage options of the base units. All heaters are dual staged. All heaters are intended for single point power supply. Disconnect Switch - For gas heat units and cooling units with electric heat, a HACR breaker sized to the unit is provided. For cooling only units, a switch sized to the largest electric heat available for the particular unit is provided. Factory installed option only. Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. Available for both the supply and/or return air configurations. Filters – 2” Pleated MERV 7 or 4” Pleated MERV 13 are available to meet LEED requirements. A 2” Throwaway is shipped as standard. Factory-installed smoke detectors may be subjected to extreme temperatures during "off" times due to outside air infiltration. These smoke detectors have an operational range of -4 °F to 158°F. Smoke detectors installed in areas that could be outside this range will have to be relocated to prevent false alarms. • Phase Monitors - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-of phase condition. (Standard on units with Scroll Compressors.) 6 • Coil Guard - Customers can purchase a coil guard kit to protect the condenser coil from damage. Additionally, this kit stops animals and foreign objects from entering the space between the inner condenser coil and the main cabinet. This is not a hail guard kit. • Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. • Technicoat Condenser Coils - The condenser coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • Technicoat Evaporator Coil - The evaporator coils are coated with a phenolic coating for protection against corrosion due to harsh environments. • ElectroFin® E-coat Condenser Coils - The condenser coils are coated with an epoxy polymer coating to protect against corrosion. • ElectroFin® E-coat Evaporator Coils - The evaporator coils are coated with an epoxy polymer coating to protect against corrosion. Control Options • BAS - Building Automation System Controls Simplicity® INTELLI-Comfort II™ Control - The York® Simplicity® INTELLI-Comfort II™ control is factory installed. It includes a supply air sensor, a return air sensor, and an outside air sensor. There are provisions for a field installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor, a Return Air Humidity sensor, an Inside IAQ sensor, and an Outside Air IAQ sensor. Construction mode operation, 365-day real time clock with 7 day programming plus holiday scheduling is built-in. Two different modes of demand ventilation are achieved through the INTELLI-Comfort II™ using CO2 sensors. It uses an inside CO2 sensor to perform Demand Ventilation. It can also use an Outside CO2 sensor to perform Differential Demand Ventilation. It uses a Patented Comfort Ventilation algorithm to provide comfortable ventilation air temperature. The patented economizer-loading algorithm will protect the equipment when harsh operating conditions exist. Humidity in the occupied space or return duct can be monitored and controlled via humidity sensors and the onboard connection for hot gas re-heat system. It uses the INTELLI-Start™ algorithm to maximize energy savings by recovering the building from the Unoccupied Setpoints to the Occupied Setpoints just in time for the Occupied Time Period to begin. The Simplicity® INTELLI-Comfort II™ balances space temperature, ventilation air temperature, CO2 and humidity for ultimate comfort. • Simplicity® INTELLI-Comfort II™ with Simplicity®LINC Control - The York® Simplicity® INTELLI-Comfort II™ with Simplicity®LINC control is factory installed. It includes all the features of the INTELLI-Comfort II™ control with an additional control to translate communications from MODBUS to the BACnet MSTP protocol. Johnson Controls Unitary Products 862075-XTG-F-0513 • Novar® BAS Control - The Novar® building automation system controller is factory installed. Incudes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • Johnson Controls BAS Control - The Johnson Control YK-UNT-1126 building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch, and air proving switch. • CPC BAS Control - The Computer Process Controls Model 810-3060 ARTC Advanced Rooftop building automation system controller is factory installed. Includes supply air sensor, return air sensor, dirty filter indicator switch and air proving switch. • Honeywell BAS Control - The Honeywell W7750C building automation system controller is factory installed. Includes air supply sensor, return air sensor, dirty filter indicator switch, and air proving switch. • York Commercial Comfort System (YCCS) - Provides rooftop system integration for YCCS single zone and change-over bypass systems (Not offered on ZR units.). Field Installed Accessories YORK® offers several equipment accessories for field installation, for the Predator® line. • Downflow Economizer - (With barometric relief) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer control accepts an optional CO2 input for demand ventilation. With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. • Horizontal Economizer - (Without barometric relief) All features of the downflow economizer exist except you must order the duct mount barometric relief separately. You must order a 1EH0408 if you are installing a power exhaust. You can order a 1RD0411 Barometric Relief for horizontal flow economizer. • Slab Economizer for Energy Recovery Ventilator(Without barometric relief or Fresh Air Hood) - The economizer is provided with a single enthalpy input. The economizer is 2% low leakage type. The economizer has spring return, fully modulating damper actuators and is capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is regulated by the standard single enthalpy input. There is an optional input dual dry bulb available. To meet regulated air standards, the economizer Johnson Controls Unitary Products • • • • • • • • • • • • control accepts an optional CO2 input for demand ventilation.With single enthalpy input, the economizer control monitors outdoor air. The dual enthalpy kit provides a second input used to monitor the return air. With a dual input kit installed, the economizer control compares the values of the two enthalpy or temperature inputs and positions the dampers to provide the maximum efficiency possible. You can order 1EH0409 Barometric Relief/FA Hood for field installations without an ERV. Dual Enthalpy Control, Accessory - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. Barometric Relief Damper - Zero to 100% capacity barometric relief dampers for use with horizontal flow, or field installed slab economizers. Power Exhaust - This accessory installs in the unit with a down flow economizer. Power exhaust plugs into the connector in the unit bulkhead. You must purchase 1EH0408 barometric relief when applying to a horizontal flow application. Manual Outdoor Air Damper - Like the motorized outdoor air damper, each manual outdoor air damper includes a slide-in damper assembly with an outdoor air hood and filters. Customers have a choice of dampers with ranges of 0% to 100% or 0% to 35% outdoor air entry. Motorized Outdoor Air Damper - The motorized outdoor air damper includes a slide-in/plug-in damper assembly with an outdoor air hood and filters. The outdoor air dampers open to the preset position when the indoor fan motor is energized. The damper has a range of 0% to 100% outdoor air entry. Factory installed option or field installed accessory. Smoke Detectors - The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. CO2 Sensor - Senses CO2 levels and automatically overrides the economizer when levels rise above the preset limits. Dirty Filter Switch - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Coil Guard - Field installed decorative wire coil guard. Hail Guard - This kit includes a sloped hood which installs over the outside condenser coil and prevents damage to the coil fins from hail strikes. Field installed accessory only. Flue Exhaust Extension Kit - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes. -60°F Gas Heat Kit - For installations which require gas heat units to perform in low ambient temperatures, a gas section heating kit is available. This kit provides electric heat in the gas heat controls section to ensure the gas valve and controls will continue to function properly at extremely low temperatures. 7 862075-XTG-F-0513 • Gas Heat High Altitude Kit - This kit converts a gas heat unit to operate at high altitudes, 2,000 to 6,000 feet. Conversion kits are available for natural gas and propane. • Gas Heat Propane Conversion Kit - This kit converts a gas-fired heater from natural gas to propane. It contains the main burner orifices and gas valve replacement springs. • Gas Piping Kit - Contains pipe nipples, fittings and gas cock required for gas supply connection with external shut off. • Electric Heaters (10 & 12.5 Ton Only) - The electric heaters range from 18 kW to 54kW. All heaters are dual staged. Cooling units include an adapter panel for easy installation of the electric heaters. Necessary hardware and connectors are included with the heaters. All heaters are intended for single point power supply. • Low Limit / Compressor Lockout Kit • Compressor Lockout (CLO): To prevent mechanical (compressorized) operation of the unit during cold outdoor conditions where there is a risk of returning liquid refrigerant back to the compressors. 8 • Low Limit Control (LLC): To prevent the supply air from dropping below a specified setpoint by utilizing the units first stage heating means when there is a demand for cooling during cold outside conditions. • Metal Frame Filter Kit - Metal frame with polyester filter medium. • Permanent Filters - Permanent filters are available. • Roof Curbs - The roof curbs have insulated decks and are shipped disassembled The roof curbs are available in 8” and 14” heights. For applications with security concerns, burglar bars are available for the duct openings of the roof curbs. • Roof Curb Transition - Single Piece Adapter (10” High) Roof curbs for transitioning from Sunline™ units to Predator® units. Fits 7.5 to 12.5 Sunline™ roof curbs only. • Burglar Bars - Mount in the supply and return openings to prevent entry into the duct work. • Thermostat - The units are designed to operate with 24volt electronic and electro-mechanical thermostats. All units (with or without an economizer) operate with twostage heat/two-stage cool or two-stage cooling only thermostats, depending upon unit configuration. Johnson Controls Unitary Products 862075-XTG-F-0513 Accessories Field Installed Accessories - Non-Electrical MODEL 1BD0408 1CG0419 1CG0420 1CG0427 1CG0428 VOLTAGE All All All All All 1HG0411 1HG0415 1FE0411 1FF0414 1FF0415 1FL0402 1FL0423 1GP0405 1HA0442 1HA0443 1NP0442 1RC0470 1RC0471 All All All All All All All All All All All All All 1RC0472 All 1WC0412 All DESCRIPTION Burglar Bars, Downflow Coil Guard Coil Guard Coil Guard Coil Guard WHERE USED All Cabinets (Electric / Electric Models), 50” Tall Standard Cabinets (Gas / Electric Models), 50" Tall Standard Cabinets (Electric / Electric Models), 42” Tall Cabinets (Gas / Electric Models), 42" Tall Cabinets All Tall (50") Standard Cabinets, (Excludes 12.5T "V" cabinets) All Short (42") Standard Cabinets All Cabinets All Tall 50" Cabinets All Tall 42" Cabinets All Tall 50" Cabinets All Tall 42" Cabinets All Cabinets All 7 1/2 - 12T Cabinets All 7 1/2 - 12T Cabinets All 6 - 12T Cabinets All Cabinets All Cabinets Hail Guard Kit Hail Guard Kit Flue Exhaust Extension Kit 2" only Metal Filter Frame Kit 2" only Metal Filter Frame Kit Permanent 2" only Filter Kit Includes (4) Four Filters) Permanent 2" only Filter Kit (Includes (4) four Filters) Gas Piping Kit High Altitude Kit for Natural Gas High Altitude Kit for Propane Propane Conversion Kit Roof Curb, 8" Height Roof Curb, 14" Height Roof Curb, Transition (7.5 T thru 12.5T Sunline to Predator 3- 12T) All Cabinets Wooden Crate for extra protection during shipping and Standard Cabinets Only (not applicable to units 119" in handling length) Field Installed Accessories - Electric Heat MODEL 2TP04521850 VOLTAGE DESCRIPTION 380/415-3-50 18kW Electric Heat WHERE USED All 50" Cabinet 10 Ton Models 2TP04522450 380/415-3-50 24kW Electric Heat All 50" Cabinet 10 and 12.5 Ton Models 2TP04523650 380/415-3-50 36kW Electric Heat All 50" Cabinet 10 and 12.5 Ton Models 2TP04525450 380/415-3-50 54kW Electric Heat All 50" Cabinet 10 and 12.5 Ton Models *Note: No factory or field installed electric heater available for 42” Cabinet ZF090 Johnson Controls Unitary Products 9 862075-XTG-F-0513 Accessories (Continued) Field Installed Accessories - Fresh Air MODEL VOLTAGE DESCRIPTION WHERE USED Barometric Relief Kit for Power Exhaust, Downflow All Application (Includes Hood) All Cabinets 1EH0407 Barometric Relief Kit for Power Exhaust, Horizontal 1EH0408 All Application All Cabinets Barometric Relief/Hood Kit - Required for field installed 1EH0409 All slab economizer without ERV All Cabinets 1FA0413 All Manual Outside Air Damper 0-35%, Downflow All Cabinets 1FA0414 All Manual Outside Air Damper 0-100%, Downflow All Cabinets 1RD0411 All Barometric Relief Kit for Horizontal Applications All Cabinets 2EC04700924 All Dual Enthalpy Control All Cabinets Downflow Economizer, Slab type for ERV, (no 2EE04705724 All Barometric Relief or FA hood) All 50" Cabinets Downflow Economizer, Slab type for ERV, (no 2EE04705824 All Barometric Relief or FA hood) All 42" Cabinets 2EE04705924 All Downflow Economizer with Barometric Relief All Cabinets 2EE04706024 All Horizontal Economizer without Barometric Relief All Cabinets 2MD04703224 All Motorized Damper, Downflow without Barometric Relief All Cabinets 2MD04703724 All Motorized Damper, Horizontal All Cabinets 2PE04703246* 460 Power Exhaust 460V Downflow or Horizontal All Cabinets * Must be installed in return Duct on Horizontal Applications and a 1EH0408 is required. Approved for operation on 50Hz Field Installed Accessories - Controls MODEL 2AP0401 2AQ04700324 2AQ04700424 2DF0402 2DH04700024 VOLTAGE All All All All All 2SD04700624 2SD04700824 2SD04700924 2SD04701024 All All All All DESCRIPTION Air Proving Switch CO2 Space Accessory CO2 Unit Accessory Dirty Air Switch Humidistat Smoke Detector for Supply or Return Smoke Detector for Supply Smoke Detector for Return Smoke Detector for Supply and Return Guide Specifications GENERAL Units shall be manufactured by York International Unitary Products in an ISO 9001 certified facility. YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 7-1/2 through 12-1/2 ton models. All units have two compressors with independent R410A refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged with R-410A, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage 10 WHERE USED All Units All Units All Units All Units All Units All Gen 4 or older units with 2" Filter only capable Cabinets All Gen 5 units with 2" & 4" Filters All Gen 5 units with 2" & 4" Filters All Gen 5 units with 2" & 4" Filters sizes. Predator® units are available in the following configurations: cooling only, cooling with electric heat, cooling with gas heat, heat pump, and heat pump with electric heat. Electric heaters are available as factory-installed options or field-installed accessories. DESCRIPTION Units shall be factory assembled, single package, (Elec/Elec, Gas/ Elec), designed for outdoor installation. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return and be available with factory installed options or field installed accessories. The units shall be factory wired, piped and charged with R-410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. The cooling performance shall be rated in accordance with DOE and AHRI test procedures and MEW-2010. Johnson Controls Unitary Products 862075-XTG-F-0513 UNIT CABINET Unit cabinet shall be constructed of galvanized steel with exterior surfaces coated with a non-chalking, powder paint finish, certified at 1000 hour salt spray test per ASTM-B117 standards. Indoor blower sections shall be insulated with up to 1” thick insulation coated on the airside. Either aluminum foil faced or elastometric rubber insulation shall be used in the unit’s compartments and be fastened to prevent insulation from entering the air stream. Cabinet doors shall be hinged with toolless access for easy servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, fork truck access and proper sealing on roof curb applications. Disposable 2” filters shall be furnished as standard and be accessible through hinged access door. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating bypass of the coils. Condensate pan shall be slide out design, constructed of a non corrosive material, internally sloped and conforming to ASHRAE 62-B9 standards. Condensate connection shall be a minimum of ¾” I.D. female and be rigid mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY Fan shall be a belt drive assembly and include an adjustable pitch motor pulley. Job site selected brake horsepower shall not exceed the motors nameplate horsepower rating plus the service factor. Units shall be designed to operate within the service factor. Fan wheel shall be double inlet type with forward curve blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. Entire blower assembly and motor shall be slide out design. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, drawthru design. c. Condenser coils shall have Micro-Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the draw-thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent thermally operated expansion devices. b. Solid core filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The unit shall have two independent refrigerant circuits, equally split in 50% capacity increments. Unit Controls: a. Unit shall be complete with self-contained low-voltage control circuit protected by a resettable circuit breaker on the 24-volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor: c. Loss-of-charge/Low-pressure switch. OUTDOOR (CONDENSER) FAN ASSEMBLY • High-pressure switch. The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. • Freeze-protection thermostat, evaporator coil. If any of the above safety devices trip, an LED (light-emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, internally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or – 10% of the unit nameplate voltage. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Johnson Controls Unitary Products d. Unit shall incorporate “AUTO RESET” compressor over temperature, over current protection. e. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. f. Unit control board shall have on-board diagnostics and fault code display. g. Standard controls shall include anti-short cycle and low voltage protection, and permit cooling operation down to 0 ºF. h. Control board shall monitor each refrigerant safety switch independently. i. Control board shall retain last 5 fault codes in nonvolatile memory, which will not be lost in the event of a power loss. 11 862075-XTG-F-0513 GAS HEATING SECTION (IF EQUIPPED) Heat exchanger and exhaust system shall be constructed of aluminized steel and shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 ºF. Burners shall be of the in-shot type, constructed of aluminum-coated steel. All gas piping shall enter the unit cabinet at a single location, through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary and auxiliary high-temperature limit switches. b. Induced draft pressure sensor. c. Flame roll out switch (manual reset). d. Flame proving controls. e. All two stage units shall have two independent stages of capacity (60% 1st stage, 100% 2nd stage). ELECTRIC HEATING SECTION (IF EQUIPPED) An electric heating section, with nickel chromium elements, shall be provided in a range of 18 thru 54 KW, offering two states of capacity all sizes. The heating section shall have a primary limit control(s) (automatic reset) to prevent the heating element system from operating at an excessive temperature. The Heating Section assembly shall slide out of the unit for easy maintenance and service. Units with Electric Heating Sections shall be wired for a single point power supply with branch circuit fusing (where required). UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125 ºF outdoor temperature, exceeding maximum load criteria of AHRI Standard 340/360. The compressor, with standard controls, shall be capable of operation down to 0 ºF outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up. (Gas heat only) ELECTRICAL REQUIREMENTS - All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES - Compressor – 5 Years, Heat Exchanger – 10 Years, Elect. Heat Elem. – 5 Years, Parts – 1 Year FACTORY INSTALLED OPTIONAL OUTDOOR AIR (Shall be made available by either/or): • ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER – Outdoor and return air dampers that are interlocked and positioned by a fully-modulating, spring-return damper actuator. The maximum leakage rate for the outdoor air 12 intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixedair temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55 ºF. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Available with barometric relief or power exhaust. • MOTORIZED OUTDOOR AIR DAMPERS – Outdoor and return air dampers that are interlocked and positioned by a 2-position, spring-return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit-mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the ventilation requirements of the conditioned space during normal operation. Whenever the indoor fan motor is energized, the dampers open up to one of two pre-selected positions – regardless of the outdoor air enthalpy. Dampers return to the fully closed position when the indoor fan motor is de-energized. Dampers shall fully close on power loss. ADDITIONAL FACTORY INSTALLED OPTIONS • ALTERNATE INDOOR BLOWER MOTOR – For applications with high restrictions, units are available with optional indoor blower motors that provide higher static output and/or higher airflow. • ELECTRIC HEAT (10 & 12.5 Ton Only) - Electric Heaters range from 18 kW to 54 kW and are available in all the voltage options of the base unit. • PHASE MONITOR - Designed to prevent damage in outof-phase condition. • COIL GUARD - Designed to prevent condenser coil damage. • BAS CONTROLS - Include supply air sensor, return air sensor, dirty filter indicator and air proving switch. • DIRTY FILTER SWITCH – This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally highpressure drop across the filters. • BREAKER – An HACR breaker can be factory installed on gas heat units or cooling units with electric heat. • DISCONNECT SWITCH - A disconnect can be factory installed on a cooling only units sized for the largest electric heat available. Johnson Controls Unitary Products 862075-XTG-F-0513 • STAINLESS STEEL HEAT EXCHANGER – For applications in a corrosive environment, this option provides a full stainless steel heat exchanger assembly. • SMOKE DETECTOR – A smoke detector can be factory mounted and wired in the supply and/or return air compartments. OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE hardware. Used to relieve internal air pressure through the unit during economizer operation. • PROPANE CONVERSION KIT – Contains new orifices and gas valve springs to convert from natural to L.P. gas. • 60ºF GAS HEAT KIT – Provides an electric heat kit for the gas compartment for use in extreme low ambient conditions. • ECONOMIZER (Downflow and Horizontal flow) • ROOF CURB - 14” and 8” high, full perimeter knockdown curb, with hinged design for quick assembly. • POWER EXHAUST – (Unit mount – Downflow, Duct mount – Horizontal flow) • BAROMETRIC RELIEF DAMPER – (Unit mounted – Downflow, Duct Mounted – Horizontal) – Contains a rain hood, air inlet screen, exhaust damper and mounting • DUAL ENTHALPY KIT - Provides a second input to economizer to monitor return air. Johnson Controls Unitary Products 13 862075-XTG-F-0513 Physical Data ZF090-150 Physical Data Models Component ZF090 ZF120 7.5 10 12.5 88200 115300 151500 Nominal Tonnage Gross Capacity @ AHRI A point (Mbh) ZF150 EER 11.2 11.2 11.0 Nominal CFM 3000 4000 5000 System power (KW) 7.21 10.05 12.7 R-410A R-410A R-410A System 1 4-12 7-12 8-3 System 2 4-12 7-8 8-10 Refrigerant type Refrigerant charge (lb-oz) AHRI HEATING PERFORMANCE Heating model 10 15 15 20 15 20 Heat input (K Btu) 120 180 180 240 180 240 Heat output (K Btu) 96 144 144 192 144 192 - - - - - - 80 80 80 80 80 80 AFUE % Steady state efficiency (%) No. burners 4 6 6 8 6 8 No. stages 21 21 21 21 21 21 15-45 30-60 20-50 35-65 10-40 25-55 Gas Limit Setting (ºF) 165 165 195 160 195 160 Gas piping connection (in.) 3/4 3/4 3/4 3/4 3/4 3/4 Temperature Rise Range (ºF) DIMENSIONS (inches) Length 89 89 119-1/2 Width 59 59 59 Height 42 50-3/4 50-3/4 OPERATING WT. (lbs.) 880 1060 1253 Scroll Scroll Scroll 2 2 2 50 / 100 50 / 100 50 / 100 18.5 29.0 29.0 COMPRESSORS Type Quantity Unit Capacity Steps (%) CONDENSER COIL DATA Face area (Sq. Ft.) Rows 1 1 1 Fins per inch 23 23 23 .71/18 1/25 1/25 Tube diameter (in.)/mm Circuitry Type 2-pass Microchannel 2-pass Microchannel 2-pass Microchannel EVAPORATOR COIL DATA Face area (Sq. Ft.) 10.6 13.2 Rows 3 4 13.2 4 Fins per inch 15 15 15 Tube diameter 0.375 0.375 0.375 Circuitry Type Intertwined Intertwined Intertwined TXV TXV TXV Refrigerant control 14 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF090-150 Physical Data (Continued) Component Nominal Tonnage Models ZF090 ZF120 ZF150 7.5 10 12.5 CONDENSER FAN DATA Quantity of Fans 2 2 4 Fan diameter (Inch) 24 24 24 Type Prop Prop Prop Drive type Direct Direct Direct Quantity of motors 2 2 4 Motor HP each @ 50 Hz. 3/4 3/4 3/4 No. speeds 1 1 1 RPM @ 50 Hz. 9402 9402 9402 Nominal total CFM 7600 9500 13900 BELT DRIVE EVAP FAN DATA Quantity 1 1 1 12 x 12 15 x 15 15 x 15 Centrifugal Centrifugal Centrifugal Motor Sheave 1VM50 1VP56 1VP56 Blower Sheave AK54 AK66 BK72 A47 A56 BX56 Fan Size (Inch) Type Belt Motor HP each @ 50 Hz. RPM @ 50 Hz. Frame size 2 4 4 14253 14553 14553 56 184T 184T 4 - (24 x 20 x 2)4,5 4 - (24 x 20 x 2)4, 5 4 - (24 x 20 x 4)6 4 - (24 x 20 x 4)6 FILTERS Quantity - Size 1. 2. 3. 4. 5. 6. 4 - (24 x 16 x 2)4, 4 - (24 x 16 x 4)6 5 1ST Stage 60% of 2nd Stage 1110 RPM 60 Hz. 1725 RPM 60 Hz. 2 In. Throwaway, Standard, MERV (Minimum Efficiency Reporting Value) 3 2 In. Pleated, Optional, MERV 7 4 In. Pleated, Optional, MERV 13 Johnson Controls Unitary Products 15 862075-XTG-F-0513 ZF078-150 Unit Limitations Unit Limitations Size (Tons/KW) 16 Model Unit Voltage Applied Voltage Outdoor DB Temp Min Max Max (°F/°C) 090 (7.5/26) ZF 380/415-3-50 342 457 125/52 120 (10/35) ZF 380/415-3-50 342 457 125/52 150 (12.5/44) ZF 380/415-3-50 342 457 125/52 Johnson Controls Unitary Products 862075-XTG-F-0513 Capacity Performance ZF090-150 Cooling Capacities ZF090 (7.5 Ton) Imperial Air on Evaporator Coil CFM 2250 2625 3000 3325 3650 2250 2625 3000 3325 3650 WB (°F) Total Capacity1,2 (MBh) Total Input (kW)3 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 105.2 98.1 90.9 82.9 82.6 108.4 101.0 93.6 85.4 85.0 111.5 103.9 96.3 87.9 87.5 112.9 105.2 97.5 88.9 88.6 114.2 106.4 98.7 90.0 89.6 6.36 6.35 6.33 6.33 5.78 6.86 6.85 6.84 6.83 6.25 7.42 7.40 7.39 7.38 6.77 7.43 7.41 7.40 7.39 6.81 7.43 7.42 7.41 7.40 6.85 45.4 58.7 72.1 79.2 78.7 48.1 63.7 79.4 80.5 80.0 50.8 68.7 86.7 81.8 81.3 58.7 74.0 89.2 83.0 82.5 66.7 79.2 91.8 84.1 83.6 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 96.0 88.3 80.6 73.9 73.6 97.4 89.6 81.8 75.0 74.7 98.9 90.9 83.0 76.2 75.8 100.3 92.2 84.2 77.3 76.9 101.7 93.6 85.4 78.4 78.0 7.80 7.79 7.78 7.77 7.77 7.98 7.97 7.96 7.95 7.95 8.21 8.20 8.19 8.18 8.18 8.53 8.52 8.51 8.50 8.50 8.85 8.84 8.83 8.82 8.82 42.6 55.9 69.1 73.9 73.6 50.6 60.7 70.7 75.0 74.7 58.6 65.4 72.3 76.2 75.8 61.9 70.4 78.8 77.3 76.9 65.2 75.3 85.4 78.4 78.0 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 85 80 75 70 65 85°F 36.2 33.7 102.4 7.01 49.6 45.4 31.2 94.4 6.99 62.9 57.1 44.5 35.4 86.4 6.98 76.7 71.5 58.3 49.1 39.9 79.2 6.97 78.7 76.4 63.0 53.9 44.7 78.7 6.96 38.7 35.9 104.1 7.19 53.8 48.3 34.0 95.9 7.17 68.9 60.7 48.0 37.5 87.8 7.16 79.2 76.0 62.6 51.8 41.0 80.5 7.15 80.0 81.2 67.4 56.3 45.1 80.0 7.15 41.2 38.0 105.8 7.42 58.1 51.1 36.8 97.5 7.41 74.9 64.3 51.4 39.6 89.3 7.39 81.8 80.4 66.9 54.4 42.0 81.8 7.38 81.3 86.0 71.8 58.7 45.6 81.3 7.38 44.9 40.3 107.3 7.74 62.0 54.3 38.0 98.9 7.73 79.1 68.3 54.0 41.4 90.5 7.71 83.0 85.2 68.8 55.9 43.1 83.0 7.70 82.5 87.8 71.0 57.8 44.6 82.5 7.70 48.5 42.7 108.8 8.06 65.9 57.5 39.2 100.3 8.05 83.3 72.3 56.6 43.3 91.8 8.03 84.1 90.0 70.8 57.4 44.1 84.1 8.02 83.6 89.6 70.3 56.9 43.6 83.6 8.02 105°F 33.4 24.1 89.6 8.60 46.6 37.3 28.1 82.2 8.59 59.8 50.6 41.3 32.0 74.8 8.57 72.8 63.5 54.2 45.0 35.7 68.7 8.58 73.6 67.4 58.2 48.9 39.6 68.4 8.58 38.1 26.4 90.8 8.78 50.7 40.8 30.9 83.3 8.77 63.4 55.3 47.2 39.1 75.8 8.75 74.5 69.5 58.7 47.9 37.1 69.6 8.76 74.7 73.7 62.6 51.4 40.2 69.3 8.76 42.8 28.6 92.0 9.01 54.9 44.3 33.8 84.4 9.00 66.9 60.0 53.1 46.2 76.7 8.98 76.2 75.4 63.1 50.7 38.4 70.5 8.99 75.8 80.1 67.0 53.9 40.8 70.2 8.99 43.8 30.1 93.3 9.33 58.5 46.6 34.8 85.6 9.31 73.2 63.2 53.1 43.1 77.9 9.30 77.3 76.9 64.1 51.4 38.6 71.6 9.30 76.9 79.0 65.9 52.7 39.6 71.3 9.30 44.8 31.6 94.7 9.65 62.1 48.9 35.7 86.9 9.63 79.5 66.3 53.1 39.9 79.0 9.62 78.4 78.4 65.2 52.0 38.8 72.6 9.62 78.0 78.0 64.8 51.6 38.4 72.3 9.62 90 45.6 59.0 72.4 79.2 78.7 57.7 63.9 70.1 80.5 80.0 69.8 68.8 67.8 81.8 81.3 68.1 73.9 79.8 83.0 82.5 66.3 79.1 91.8 84.1 83.6 39.6 52.7 65.8 68.7 68.4 43.5 57.4 71.3 69.6 69.3 47.4 62.1 76.7 70.5 70.2 55.7 66.8 77.9 71.6 71.3 64.1 71.6 79.0 72.6 72.3 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 95°F 36.3 27.0 49.7 40.4 31.0 63.1 53.7 44.4 35.1 76.8 67.5 58.1 48.8 78.7 72.2 62.9 53.6 43.5 29.3 53.9 43.9 33.9 64.3 58.4 52.6 46.8 79.3 73.4 62.6 51.8 80.0 78.6 67.3 56.0 50.8 31.7 58.1 47.4 36.7 65.5 63.1 60.8 58.5 81.8 79.3 67.0 54.7 81.3 84.9 71.7 58.4 49.6 33.4 62.0 50.0 38.0 74.3 66.6 58.8 51.0 83.0 81.7 68.9 56.2 82.5 84.3 71.0 57.8 48.4 35.1 65.8 52.6 39.3 83.2 70.0 56.7 43.5 84.1 84.1 70.9 57.6 83.6 83.6 70.4 57.1 115°F 30.4 21.3 43.5 34.3 25.1 56.6 47.4 38.2 29.0 68.7 59.5 50.3 41.1 68.4 62.6 53.4 44.2 32.7 23.4 47.6 37.8 28.0 62.5 52.2 41.8 31.5 69.6 65.5 54.8 44.0 69.3 68.9 57.9 46.8 34.9 25.5 51.7 41.2 30.8 68.4 56.9 45.4 34.0 70.5 71.6 59.2 46.8 70.2 75.3 62.3 49.3 38.0 26.8 55.0 43.3 31.5 72.0 59.7 47.4 35.1 71.6 72.1 59.3 46.6 71.3 73.8 60.7 47.7 41.2 28.1 58.4 45.3 32.2 75.7 62.6 49.4 36.3 72.6 72.6 59.5 46.4 72.3 72.3 59.2 46.1 65 39.5 44.2 40.9 44.7 42.4 45.2 43.4 44.6 44.4 43.9 32.0 35.0 33.2 35.7 34.4 36.4 33.8 34.7 33.2 32.9 17 862075-XTG-F-0513 ZF090 (7.5 Ton) Imperial (Continued) Air on Evaporator Coil CFM 2250 2625 3000 3325 3650 WB (°F) Total Capacity1,2 (MBh) Total Input (kW)3 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 88.3 80.4 72.5 68.0 67.8 89.2 81.5 73.7 68.9 68.7 90.1 82.5 75.0 69.8 69.6 91.7 83.7 75.8 70.9 70.6 93.3 85.0 76.6 71.9 71.7 8.85 8.84 8.84 8.83 8.83 9.04 9.03 9.02 9.02 9.01 9.28 9.26 9.26 9.25 9.24 9.60 9.59 9.58 9.57 9.56 9.92 9.91 9.90 9.89 9.88 33.5 46.7 59.9 64.0 64.2 36.7 50.8 64.9 66.6 66.8 39.8 54.9 69.9 69.2 69.4 45.7 58.9 72.2 70.5 70.5 51.6 63.0 74.4 71.9 71.7 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 85 80 75 70 65 118.4°F 26.8 20.2 85.8 9.48 40.1 33.4 26.8 76.9 9.47 53.3 46.6 40.0 33.3 68.0 9.45 63.4 56.8 50.1 43.5 36.8 66.8 9.45 63.6 59.2 52.5 45.9 39.2 66.6 9.45 29.1 22.5 86.1 9.66 43.8 36.8 29.8 78.0 9.64 58.5 51.0 43.6 36.1 69.8 9.63 65.9 62.5 54.7 46.9 39.0 67.7 9.63 66.1 65.1 57.2 49.2 41.2 67.5 9.63 31.3 24.8 86.4 9.88 47.5 40.1 32.8 79.0 9.87 63.7 55.5 47.2 38.9 71.6 9.86 68.3 68.2 59.2 50.2 41.3 68.5 9.86 68.6 71.1 61.8 52.4 43.1 68.4 9.86 33.5 25.5 88.6 10.20 50.5 42.1 33.7 80.1 10.19 67.6 58.7 49.9 41.0 71.7 10.18 70.1 69.6 60.4 51.2 42.0 69.6 10.17 70.1 71.2 61.8 52.4 43.0 69.4 10.17 35.7 26.2 90.7 10.51 53.6 44.1 34.7 81.3 10.51 71.4 62.0 52.5 43.1 71.9 10.50 71.8 71.0 61.5 52.1 42.6 70.6 10.49 71.7 71.3 61.8 52.4 42.9 70.4 10.49 90 21.5 35.1 48.6 54.8 55.9 23.3 38.0 52.6 60.6 61.8 25.1 40.9 56.7 66.5 67.8 26.2 43.6 61.1 68.5 69.1 27.3 46.4 65.5 70.6 70.4 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 19.8 18.1 33.4 31.6 29.9 46.9 45.2 43.5 41.7 53.1 51.4 49.7 47.9 54.2 52.5 50.8 49.1 22.1 20.8 36.4 34.8 33.3 50.8 48.9 47.0 45.1 58.6 56.6 54.5 52.5 59.8 57.8 55.8 53.8 24.3 23.5 39.5 38.0 36.6 54.6 52.6 50.5 48.5 64.1 61.7 59.4 57.0 65.4 63.1 60.8 58.4 24.7 23.1 41.8 39.9 38.0 58.9 56.7 54.5 52.4 67.1 64.8 62.4 60.1 67.9 66.2 63.9 61.6 25.0 22.7 44.1 41.8 39.5 63.2 60.8 58.5 56.2 70.2 67.8 65.5 63.2 70.4 69.3 67.0 64.7 65 46.2 47.4 50.4 51.7 54.6 56.1 57.8 59.3 60.9 62.4 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. Capacity rating are based on 80 F (26.6 C) Entering Air Dry Bulb Temperature. 3. These ratings include the condenser fan motors, the compressor motors and supply air blower motor (External Static Pressure 0.25 IWG/ 62.3 Pa). 18 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF090 (26 kW) Metric Air on Evaporator Coil 3 m /s 1.06 1.24 1.42 1.57 1.72 1.06 1.24 1.42 1.57 1.72 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 30.8 28.7 26.6 24.3 24.2 31.8 29.6 27.4 25.0 24.9 32.7 30.5 28.2 25.8 25.6 33.1 30.8 28.6 26.1 26.0 33.5 31.2 28.9 26.4 26.3 6.36 6.35 6.33 6.33 5.78 6.86 6.85 6.84 6.83 6.25 7.42 7.40 7.39 7.38 6.77 7.43 7.41 7.40 7.39 6.81 7.43 7.42 7.41 7.40 6.85 13.3 17.2 21.1 23.2 23.1 14.1 18.7 23.3 23.6 23.5 14.9 20.1 25.4 24.0 23.8 17.2 21.7 26.2 24.3 24.2 19.6 23.2 26.9 24.7 24.5 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 28.1 25.9 23.6 21.7 21.6 28.6 26.3 24.0 22.0 21.9 29.0 26.6 24.3 22.3 22.2 29.4 27.0 24.7 22.6 22.5 29.8 27.4 25.0 23.0 22.9 7.78 7.78 7.78 7.77 7.77 7.96 7.96 7.96 7.95 7.95 8.19 8.19 8.19 8.18 8.18 8.51 8.51 8.51 8.50 8.50 8.83 8.83 8.83 8.82 8.82 12.5 16.4 20.2 21.7 21.6 14.8 17.8 20.7 22.0 21.9 17.2 19.2 21.2 22.3 22.2 18.1 20.6 23.1 22.6 22.5 19.1 22.1 25.0 23.0 22.9 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (kW) Total Total Return Dry Bulb (°C) Capacity1,2 Input (kW) (kW)3 29 27 24 21 18 29°C 10.6 9.9 30.0 7.01 14.5 13.3 9.1 27.7 6.99 18.4 16.7 13.1 10.4 25.3 6.98 22.5 20.9 17.1 14.4 11.7 23.2 6.97 23.1 22.4 18.5 15.8 13.1 23.1 6.96 11.3 10.5 30.5 7.19 15.8 14.1 10.0 28.1 7.17 20.2 17.8 14.1 11.0 25.7 7.16 23.2 22.3 18.3 15.2 12.0 23.6 7.15 23.5 23.8 19.8 16.5 13.2 23.5 7.14 12.1 11.1 31.0 7.42 17.0 15.0 10.8 28.6 7.40 22.0 18.8 15.1 11.6 26.2 7.39 24.0 23.6 19.6 16.0 12.3 24.0 7.38 23.8 25.2 21.0 17.2 13.4 23.8 7.38 13.1 11.8 31.4 7.74 18.2 15.9 11.1 29.0 7.73 23.2 20.0 15.8 12.1 26.5 7.71 24.3 25.0 20.2 16.4 12.6 24.3 7.70 24.2 25.7 20.8 16.9 13.1 24.2 7.70 14.2 12.5 31.9 8.06 19.3 16.8 11.5 29.4 8.05 24.4 21.2 16.6 12.7 26.9 8.03 24.7 26.4 20.7 16.8 12.9 24.7 8.02 24.5 26.3 20.6 16.7 12.8 24.5 8.02 41°C 9.8 7.1 26.3 8.56 13.7 10.9 8.2 24.1 8.57 17.5 14.8 12.1 9.4 21.9 8.57 21.3 18.6 15.9 13.2 10.5 20.1 8.58 21.6 19.8 17.0 14.3 11.6 20.0 8.58 11.2 7.7 26.6 8.74 14.9 12.0 9.1 24.4 8.75 18.6 16.2 13.8 11.5 22.2 8.75 21.8 20.4 17.2 14.0 10.9 20.4 8.76 21.9 21.6 18.3 15.1 11.8 20.3 8.76 12.6 8.4 27.0 8.97 16.1 13.0 9.9 24.7 8.98 19.6 17.6 15.6 13.5 22.5 8.98 22.3 22.1 18.5 14.9 11.3 20.7 8.99 22.2 23.5 19.6 15.8 12.0 20.6 8.99 12.8 8.8 27.4 9.29 17.1 13.7 10.2 25.1 9.29 21.5 18.5 15.6 12.6 22.8 9.30 22.6 22.5 18.8 15.1 11.3 21.0 9.30 22.5 23.2 19.3 15.5 11.6 20.9 9.30 13.1 9.3 27.8 9.61 18.2 14.3 10.5 25.5 9.61 23.3 19.4 15.6 11.7 23.2 9.62 23.0 23.0 19.1 15.2 11.4 21.3 9.62 22.9 22.9 19.0 15.1 11.3 21.2 9.62 32 13.4 17.3 21.2 23.2 23.1 16.9 18.7 20.5 23.6 23.5 20.5 20.2 19.9 24.0 23.8 20.0 21.7 23.4 24.3 24.2 19.4 23.2 26.9 24.7 24.5 11.6 15.4 19.3 20.1 20.0 12.8 16.8 20.9 20.4 20.3 13.9 18.2 22.5 20.7 20.6 16.3 19.6 22.8 21.0 20.9 18.8 21.0 23.2 21.3 21.2 Sensible Capacity (kW) Return Dry Bulb (°C) 29 27 24 21 35°C 10.6 7.9 14.6 11.8 9.1 18.5 15.8 13.0 10.3 22.5 19.8 17.0 14.3 23.1 21.2 18.4 15.7 12.8 8.6 15.8 12.9 9.9 18.8 17.1 15.4 13.7 23.2 21.5 18.3 15.2 23.5 23.0 19.7 16.4 14.9 9.3 17.0 13.9 10.8 19.2 18.5 17.8 17.1 24.0 23.2 19.6 16.0 23.8 24.9 21.0 17.1 14.5 9.8 18.2 14.6 11.1 21.8 19.5 17.2 14.9 24.3 23.9 20.2 16.5 24.2 24.7 20.8 16.9 14.2 10.3 19.3 15.4 11.5 24.4 20.5 16.6 12.7 24.7 24.7 20.8 16.9 24.5 24.5 20.6 16.7 46°C 8.9 6.2 12.8 10.1 7.4 16.6 13.9 11.2 8.5 20.1 17.4 14.8 12.1 20.0 18.4 15.7 13.0 9.6 6.9 13.9 11.1 8.2 18.3 15.3 12.3 9.2 20.4 19.2 16.0 12.9 20.3 20.2 17.0 13.7 10.2 7.5 15.1 12.1 9.0 20.1 16.7 13.3 10.0 20.7 21.0 17.3 13.7 20.6 22.1 18.3 14.5 11.2 7.9 16.1 12.7 9.2 21.1 17.5 13.9 10.3 21.0 21.1 17.4 13.6 20.9 21.6 17.8 14.0 12.1 8.2 17.1 13.3 9.4 22.2 18.3 14.5 10.6 21.3 21.3 17.4 13.6 21.2 21.2 17.3 13.5 18 11.6 13.0 12.0 13.1 12.4 13.3 12.7 13.1 13.0 12.9 9.4 10.3 9.7 10.5 10.1 10.7 9.9 10.2 9.7 9.7 19 862075-XTG-F-0513 ZF090 (26 kW) Metric (Continued) Air on Evaporator Coil m3/s 1.06 1.24 1.42 1.57 1.72 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25.9 23.6 21.2 19.9 19.9 26.1 23.9 21.6 20.2 20.1 26.4 24.2 22.0 20.5 20.4 26.9 24.5 22.2 20.8 20.7 27.4 24.9 22.5 21.1 21.0 8.85 8.84 8.84 8.83 8.83 9.04 9.03 9.02 9.02 9.01 9.28 9.26 9.26 9.25 9.24 9.60 9.59 9.58 9.57 9.56 9.92 9.91 9.90 9.89 9.88 9.8 13.7 17.6 18.7 18.8 10.7 14.9 19.0 19.5 19.6 11.7 16.1 20.5 20.3 20.3 13.4 17.3 21.2 20.7 20.7 15.1 18.5 21.8 21.1 21.0 Temperature of Air on Condenser Coil Sensible Capacity (kW) Total Total Return Dry Bulb (°C) Capacity1,2 Input (kW) (kW)3 29 27 24 21 18 48°C 7.9 5.9 25.2 9.48 11.7 9.8 7.8 22.5 9.47 15.6 13.7 11.7 9.8 19.9 9.45 18.6 16.6 14.7 12.7 10.8 19.6 9.45 18.6 17.3 15.4 13.4 11.5 19.5 9.45 8.5 6.6 25.2 9.66 12.8 10.8 8.7 22.8 9.64 17.1 15.0 12.8 10.6 20.5 9.63 19.3 18.3 16.0 13.7 11.4 19.8 9.63 19.4 19.1 16.8 14.4 12.1 19.8 9.63 9.2 7.3 25.3 9.88 13.9 11.8 9.6 23.1 9.87 18.7 16.3 13.8 11.4 21.0 9.86 20.0 20.0 17.4 14.7 12.1 20.1 9.86 20.1 20.8 18.1 15.4 12.6 20.0 9.86 9.8 7.5 26.0 10.20 14.8 12.3 9.9 23.5 10.19 19.8 17.2 14.6 12.0 21.0 10.18 20.5 20.4 17.7 15.0 12.3 20.4 10.17 20.6 20.9 18.1 15.4 12.6 20.3 10.17 10.5 7.7 26.6 10.51 15.7 12.9 10.2 23.8 10.51 20.9 18.2 15.4 12.6 21.1 10.50 21.0 20.8 18.0 15.3 12.5 20.7 10.49 21.0 20.9 18.1 15.4 12.6 20.6 10.49 32 6.3 10.3 14.2 16.1 16.4 6.8 11.1 15.4 17.8 18.1 7.4 12.0 16.6 19.5 19.9 7.7 12.8 17.9 20.1 20.2 8.0 13.6 19.2 20.7 20.6 Sensible Capacity (kW) Return Dry Bulb (°C) 29 27 24 21 52°C 5.8 5.3 9.8 9.3 8.8 13.7 13.2 12.7 12.2 15.6 15.1 14.6 14.0 15.9 15.4 14.9 14.4 6.5 6.1 10.7 10.2 9.7 14.9 14.3 13.8 13.2 17.2 16.6 16.0 15.4 17.5 16.9 16.3 15.8 7.1 6.9 11.6 11.1 10.7 16.0 15.4 14.8 14.2 18.8 18.1 17.4 16.7 19.2 18.5 17.8 17.1 7.2 6.8 12.2 11.7 11.1 17.3 16.6 16.0 15.3 19.7 19.0 18.3 17.6 19.9 19.4 18.7 18.0 7.3 6.7 12.9 12.2 11.6 18.5 17.8 17.2 16.5 20.6 19.9 19.2 18.5 20.6 20.3 19.6 19.0 18 13.5 13.9 14.8 15.2 16.0 16.4 16.9 17.4 17.8 18.3 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. Capacity rating are based on 80 F (26.6 C) Entering Air Dry Bulb Temperature. 3. These ratings include the condenser fan motors, the compressor motors and supply air blower motor (External Static Pressure 0.25 IWG/ 62.3 Pa). 20 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF120 (10 Ton) Imperial Air on Evaporator Coil CFM 3000 3500 4000 4550 5100 3000 3500 4000 4550 5100 WB (°F) Total Capacity1,2 (MBh) Total Input (kW)3 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 120.6 115.1 109.6 103.7 95.5 128.2 122.4 116.6 110.3 101.6 135.9 129.7 123.5 116.8 107.6 134.8 128.7 122.7 116.1 106.9 133.8 127.8 121.8 115.3 106.2 8.40 8.47 8.54 8.56 8.56 8.64 8.71 8.78 8.80 8.80 8.97 9.04 9.11 9.14 9.14 9.53 9.60 9.67 9.69 9.69 9.98 10.05 10.12 10.15 10.14 68.1 83.7 99.2 103.7 95.5 70.2 90.3 110.4 110.3 101.6 72.2 96.9 121.5 116.8 107.6 92.3 107.0 121.7 116.1 106.9 112.4 117.1 121.8 115.3 106.2 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 120.9 108.8 96.8 89.8 85.2 128.2 115.4 102.6 95.3 90.3 135.5 122.0 108.5 100.7 95.5 136.2 122.6 109.0 101.2 95.9 136.8 123.2 109.5 101.6 96.4 10.83 10.72 10.60 10.55 10.52 11.12 11.01 10.89 10.84 10.81 11.51 11.40 11.28 11.22 11.20 12.08 11.96 11.85 11.79 11.76 12.54 12.43 12.32 12.26 12.23 66.9 78.9 91.0 89.8 85.2 71.0 85.2 99.4 95.3 90.3 75.2 91.5 107.8 100.7 95.5 96.7 102.7 108.7 101.2 95.9 118.3 113.9 109.5 101.6 96.4 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 85 80 75 70 65 85°F 55.8 43.5 120.7 9.61 71.4 59.1 46.8 112.0 9.59 86.9 74.7 62.4 50.1 103.2 9.57 89.8 77.5 65.2 52.9 40.7 96.8 9.56 95.5 92.3 80.0 67.7 55.5 90.4 9.54 59.1 46.9 128.2 9.88 77.0 63.7 50.4 118.9 9.86 94.9 80.5 66.2 51.8 109.6 9.83 99.7 83.6 69.2 54.9 40.6 102.8 9.82 101.6 99.6 84.7 69.9 55.1 96.0 9.80 62.4 50.3 135.7 10.24 82.6 68.3 54.1 125.8 10.22 102.8 86.4 69.9 53.5 116.0 10.20 109.6 89.6 73.2 56.9 40.5 108.8 10.18 107.6 106.8 89.5 72.1 54.7 101.6 10.17 68.8 54.6 135.5 10.80 90.6 74.2 57.8 125.7 10.78 112.3 93.8 76.3 58.8 115.8 10.76 112.4 99.3 81.9 64.4 47.0 108.6 10.74 106.9 106.5 88.5 70.6 52.6 101.4 10.73 75.3 58.8 135.3 11.26 98.6 80.0 61.5 125.5 11.24 121.8 101.2 82.7 64.1 115.7 11.22 115.3 109.1 90.5 72.0 53.4 108.5 11.20 106.2 106.2 87.6 69.1 50.5 101.3 11.19 105°F 54.6 42.2 121.0 12.04 66.6 54.3 41.9 105.7 11.84 78.6 66.3 54.0 41.6 90.4 11.64 85.0 72.7 60.3 48.0 35.7 82.9 11.54 85.2 80.4 68.0 55.7 43.4 80.0 11.50 57.9 46.0 128.1 12.36 72.1 59.0 45.9 111.9 12.16 86.3 72.1 57.9 43.7 95.7 11.95 91.6 79.1 64.7 50.3 35.9 87.8 11.85 90.3 87.4 72.7 58.0 43.2 84.7 11.81 61.3 49.7 135.3 12.78 77.7 63.8 49.9 118.1 12.57 94.0 77.9 61.8 45.7 101.0 12.37 98.3 85.5 69.0 52.6 36.2 92.7 12.27 95.5 94.5 77.3 60.2 43.1 89.4 12.23 71.6 55.0 136.8 13.35 86.7 70.6 54.6 119.5 13.15 101.8 86.2 69.1 51.9 102.2 12.94 100.0 92.5 75.2 57.9 40.6 93.7 12.84 95.9 95.4 77.7 60.1 42.4 90.5 12.80 81.8 60.3 138.4 13.82 95.7 77.4 59.2 120.9 13.62 109.5 94.6 76.3 58.1 103.3 13.41 101.6 99.5 81.3 63.1 44.9 94.8 13.31 96.4 96.4 78.2 59.9 41.7 91.5 13.27 90 67.5 81.3 95.1 96.8 90.4 70.6 87.7 104.9 102.8 96.0 73.7 94.2 114.7 108.8 101.6 94.5 104.8 115.2 108.6 101.4 115.3 115.5 115.7 108.5 101.3 66.3 76.6 86.8 82.9 80.0 71.5 82.7 93.9 87.8 84.7 76.7 88.8 101.0 92.7 89.4 98.9 100.6 102.2 93.7 90.5 121.2 112.3 103.3 94.8 91.5 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 95°F 55.2 42.9 69.0 56.7 44.4 82.8 70.5 58.2 45.9 87.4 75.1 62.8 50.5 90.4 86.3 74.0 61.7 58.5 46.4 74.6 61.4 48.2 90.6 76.3 62.0 47.7 95.7 81.3 67.0 52.6 96.0 93.5 78.7 63.9 61.8 50.0 80.1 66.1 52.0 98.4 82.1 65.9 49.6 103.9 87.5 71.1 54.7 101.6 100.6 83.4 66.2 70.2 54.8 88.6 72.4 56.2 107.0 90.0 72.7 55.4 106.2 95.9 78.5 61.1 101.4 101.0 83.1 65.3 78.5 59.6 97.1 78.7 60.3 115.7 97.9 79.5 61.1 108.5 104.3 85.9 67.5 101.3 101.3 82.9 64.5 115°F 53.9 41.6 64.2 51.8 39.5 74.5 62.1 49.8 37.4 82.6 70.2 57.9 45.5 80.0 74.4 62.0 49.7 57.3 45.5 69.7 56.7 43.7 82.1 67.9 53.8 39.6 87.6 76.8 62.4 48.0 84.7 81.3 66.6 52.0 60.7 49.4 75.2 61.5 47.9 89.7 73.7 57.8 41.8 92.7 83.4 66.9 50.5 89.4 88.3 71.3 54.3 72.9 55.2 84.7 68.8 53.0 96.5 82.5 65.5 48.5 93.7 89.1 71.8 54.6 90.5 89.9 72.4 54.8 85.1 61.1 94.2 76.2 58.1 103.3 91.2 73.2 55.1 94.8 94.8 76.7 58.7 91.5 91.5 73.4 55.4 65 38.2 49.4 38.3 49.2 38.4 48.9 43.8 47.5 49.2 46.1 33.2 37.3 33.6 37.3 34.1 37.3 37.4 37.3 40.6 37.3 21 862075-XTG-F-0513 ZF120 (10 Ton) Imperial (Continued) Air on Evaporator Coil CFM 3000 3500 4000 4550 5100 WB (°F) Total Capacity1,2 (MBh) Total Input (kW)3 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 118.0 102.1 86.2 80.0 77.7 124.8 108.1 91.4 84.7 82.3 131.6 114.1 96.7 89.5 86.9 132.7 115.5 98.2 90.5 87.8 133.9 116.8 99.6 91.5 88.8 12.34 12.21 12.09 11.98 11.96 12.67 12.53 12.39 12.30 12.27 13.11 12.95 12.79 12.71 12.69 13.69 13.52 13.36 13.29 13.26 14.16 14.00 13.83 13.76 13.74 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 90 85 80 75 70 65 118.4°F 67.4 53.5 41.1 112.2 12.91 75.7 63.3 50.9 38.6 95.2 12.94 83.9 73.1 60.7 48.4 36.0 78.1 12.96 80.0 79.8 69.0 56.6 44.3 31.9 74.5 12.84 77.7 77.7 71.8 59.5 47.1 34.7 73.2 12.84 73.2 57.3 45.4 118.3 13.28 81.8 68.7 55.7 42.6 100.8 13.26 90.3 80.1 66.0 51.8 37.7 83.2 13.23 84.7 84.6 75.4 60.9 46.4 31.9 78.8 13.16 82.3 82.3 78.5 63.8 49.1 34.4 77.5 13.16 79.0 61.2 49.7 124.5 13.76 87.9 74.2 60.4 46.7 106.4 13.68 96.7 87.1 71.2 55.3 39.4 88.3 13.61 89.5 89.5 81.9 65.2 48.6 31.9 83.2 13.58 86.9 86.9 85.2 68.2 51.1 34.1 81.8 13.58 100.8 74.0 55.0 124.8 14.34 99.5 83.7 67.6 51.6 107.6 14.26 98.2 93.4 80.3 63.1 45.9 90.4 14.17 90.5 90.5 86.7 69.2 51.6 34.1 84.2 14.16 87.8 87.8 87.0 69.3 51.5 33.8 82.8 14.15 122.6 86.8 60.2 125.2 14.82 111.1 93.2 74.8 56.4 108.8 14.73 99.6 99.6 89.4 70.9 52.5 92.5 14.64 91.5 91.5 91.5 73.1 54.6 36.2 85.1 14.64 88.8 88.8 88.8 70.4 52.0 33.5 83.7 14.63 90 69.7 73.9 78.1 74.5 73.2 76.7 80.0 83.2 78.8 77.5 83.7 86.0 88.3 83.2 81.8 104.4 97.4 90.4 84.2 82.8 125.2 108.8 92.5 85.1 83.7 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 52.6 40.2 61.5 49.1 36.7 70.4 58.1 45.7 33.3 74.5 66.6 54.2 41.8 73.2 66.9 54.5 42.1 57.4 45.3 66.8 53.7 40.6 76.3 62.2 48.0 33.9 78.8 72.8 58.0 43.3 77.5 73.1 58.3 43.5 62.2 50.4 72.2 58.3 44.5 82.1 66.3 50.4 34.6 83.2 79.0 61.9 44.8 81.8 79.4 62.2 45.0 76.2 54.5 81.8 65.3 48.8 87.3 76.0 58.5 41.0 84.2 82.1 63.9 45.8 82.8 81.5 63.4 45.2 90.2 58.6 91.4 72.2 53.0 92.5 85.7 66.6 47.4 85.1 85.1 66.0 46.8 83.7 83.7 64.5 45.4 65 29.4 29.7 28.5 28.7 27.6 27.8 27.6 27.0 27.6 26.2 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. Capacity rating are based on 80 F (26.6 C) Entering Air Dry Bulb Temperature. 3. These ratings include the condenser fan motors, the compressor motors and supply air blower motor (External Static Pressure 0.30 IWG/ 74.7 Pa). 22 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF120 (35 kW) Metric Air on Evaporator Coil 3 m /s 1.42 1.65 1.89 2.15 2.41 1.42 1.65 1.89 2.15 2.41 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 35.3 33.7 32.1 30.4 28.0 37.6 35.9 34.2 32.3 29.8 39.8 38.0 36.2 34.2 31.5 39.5 37.7 36.0 34.0 31.3 39.2 37.5 35.7 33.8 31.1 8.40 8.47 8.54 8.56 8.56 8.64 8.71 8.78 8.80 8.80 8.97 9.04 9.11 9.14 9.14 9.53 9.60 9.67 9.69 9.69 9.98 10.05 10.12 10.15 10.14 20.0 24.5 29.1 30.4 28.0 20.6 26.5 32.3 32.3 29.8 21.2 28.4 35.6 34.2 31.5 27.0 31.4 35.7 34.0 31.3 32.9 34.3 35.7 33.8 31.1 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 35.4 31.9 28.4 26.3 25.0 37.6 33.8 30.1 27.9 26.5 39.7 35.8 31.8 29.5 28.0 39.9 35.9 31.9 29.7 28.1 40.1 36.1 32.1 29.8 28.2 10.83 10.72 10.60 10.55 10.52 11.12 11.01 10.89 10.84 10.81 11.51 11.40 11.28 11.22 11.20 12.08 11.96 11.85 11.79 11.76 12.54 12.43 12.32 12.26 12.23 19.6 23.1 26.7 26.3 25.0 20.8 25.0 29.1 27.9 26.5 22.0 26.8 31.6 29.5 28.0 28.3 30.1 31.9 29.7 28.1 34.7 33.4 32.1 29.8 28.2 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (kW) Total Total Return Dry Bulb (°C) Capacity1 Input (kW) (kW)2 29 27 24 21 18 29°C 16.4 12.8 35.4 9.61 20.9 17.3 13.7 32.8 9.59 25.5 21.9 18.3 14.7 30.2 9.57 26.3 22.7 19.1 15.5 11.9 28.4 9.56 28.0 27.1 23.5 19.9 16.3 26.5 9.54 17.3 13.8 37.6 9.88 22.6 18.7 14.8 34.8 9.86 27.8 23.6 19.4 15.2 32.1 9.83 29.2 24.5 20.3 16.1 11.9 30.1 9.82 29.8 29.2 24.8 20.5 16.2 28.1 9.80 18.3 14.7 39.8 10.24 24.2 20.0 15.8 36.9 10.22 30.1 25.3 20.5 15.7 34.0 10.20 32.1 26.3 21.5 16.7 11.9 31.9 10.18 31.5 31.3 26.2 21.1 16.0 29.8 10.17 20.2 16.0 39.7 10.80 26.5 21.7 16.9 36.8 10.78 32.9 27.5 22.4 17.2 33.9 10.76 33.0 29.1 24.0 18.9 13.8 31.8 10.74 31.3 31.2 26.0 20.7 15.4 29.7 10.73 22.1 17.2 39.7 11.26 28.9 23.5 18.0 36.8 11.24 35.7 29.7 24.2 18.8 33.9 11.22 33.8 32.0 26.5 21.1 15.7 31.8 11.20 31.1 31.1 25.7 20.2 14.8 29.7 11.19 41°C 16.0 12.4 35.5 12.04 19.5 15.9 12.3 31.0 11.84 23.0 19.4 15.8 12.2 26.5 11.64 24.9 21.3 17.7 14.1 10.5 24.3 11.54 25.0 23.6 19.9 16.3 12.7 23.4 11.50 17.0 13.5 37.6 12.36 21.1 17.3 13.5 32.8 12.16 25.3 21.1 17.0 12.8 28.0 11.95 26.9 23.2 19.0 14.7 10.5 25.7 11.85 26.5 25.6 21.3 17.0 12.7 24.8 11.81 18.0 14.6 39.6 12.78 22.8 18.7 14.6 34.6 12.57 27.6 22.8 18.1 13.4 29.6 12.37 28.8 25.0 20.2 15.4 10.6 27.2 12.27 28.0 27.7 22.7 17.6 12.6 26.2 12.23 21.0 16.1 40.1 13.35 25.4 20.7 16.0 35.0 13.15 29.8 25.3 20.2 15.2 29.9 12.94 29.3 27.1 22.0 17.0 11.9 27.5 12.84 28.1 28.0 22.8 17.6 12.4 26.5 12.80 24.0 17.7 40.6 13.82 28.0 22.7 17.4 35.4 13.62 32.1 27.7 22.4 17.0 30.3 13.41 29.8 29.2 23.8 18.5 13.2 27.8 13.31 28.2 28.2 22.9 17.6 12.2 26.8 13.27 32 19.8 23.8 27.9 28.4 26.5 20.7 25.7 30.7 30.1 28.1 21.6 27.6 33.6 31.9 29.8 27.7 30.7 33.8 31.8 29.7 33.8 33.8 33.9 31.8 29.7 19.4 22.4 25.4 24.3 23.4 21.0 24.2 27.5 25.7 24.8 22.5 26.0 29.6 27.2 26.2 29.0 29.5 29.9 27.5 26.5 35.5 32.9 30.3 27.8 26.8 Sensible Capacity (kW) Return Dry Bulb (°C) 29 27 24 21 35°C 16.2 12.6 20.2 16.6 13.0 24.3 20.7 17.0 13.4 25.6 22.0 18.4 14.8 26.5 25.3 21.7 18.1 17.2 13.6 21.9 18.0 14.1 26.6 22.4 18.2 14.0 28.0 23.8 19.6 15.4 28.1 27.4 23.1 18.7 18.1 14.7 23.5 19.4 15.2 28.8 24.1 19.3 14.5 30.5 25.7 20.8 16.0 29.8 29.5 24.4 19.4 20.6 16.1 26.0 21.2 16.5 31.4 26.4 21.3 16.2 31.1 28.1 23.0 17.9 29.7 29.6 24.4 19.1 23.0 17.5 28.5 23.1 17.7 33.9 28.7 23.3 17.9 31.8 30.6 25.2 19.8 29.7 29.7 24.3 18.9 46°C 15.8 12.2 18.8 15.2 11.6 21.8 18.2 14.6 11.0 24.2 20.6 17.0 13.3 23.4 21.8 18.2 14.6 16.8 13.3 20.4 16.6 12.8 24.1 19.9 15.8 11.6 25.7 22.5 18.3 14.1 24.8 23.8 19.5 15.2 17.8 14.5 22.0 18.0 14.0 26.3 21.6 16.9 12.3 27.2 24.4 19.6 14.8 26.2 25.9 20.9 15.9 21.4 16.2 24.8 20.2 15.5 28.3 24.2 19.2 14.2 27.5 26.1 21.1 16.0 26.5 26.3 21.2 16.1 24.9 17.9 27.6 22.3 17.0 30.3 26.7 21.4 16.2 27.8 27.8 22.5 17.2 26.8 26.8 21.5 16.2 18 11.2 14.5 11.2 14.4 11.2 14.3 12.8 13.9 14.4 13.5 9.7 10.9 9.9 10.9 10.0 10.9 11.0 10.9 11.9 10.9 23 862075-XTG-F-0513 ZF120 (35 kW) Metric (Continued) Air on Evaporator Coil m3/s 1.42 1.65 1.89 2.15 2.41 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 34.6 29.9 25.3 23.5 22.8 36.6 31.7 26.8 24.8 24.1 38.6 33.5 28.3 26.2 25.5 38.9 33.8 28.8 26.5 25.7 39.2 34.2 29.2 26.8 26.0 12.34 12.21 12.09 11.98 11.96 12.67 12.53 12.39 12.30 12.27 13.11 12.95 12.79 12.71 12.69 13.69 13.52 13.36 13.29 13.26 14.16 14.00 13.83 13.76 13.74 19.8 22.2 24.6 23.5 22.8 21.5 24.0 26.5 24.8 24.1 23.2 25.8 28.3 26.2 25.5 29.5 29.2 28.8 26.5 25.7 35.9 32.6 29.2 26.8 26.0 Temperature of Air on Condenser Coil Sensible Capacity (kW) Total Total Return Dry Bulb (°C) Capacity1 Input (kW) (kW)2 29 27 24 21 18 48°C 15.7 12.1 32.9 12.91 18.5 14.9 11.3 27.9 12.94 21.4 17.8 14.2 10.5 22.9 12.96 23.4 20.2 16.6 13.0 9.3 21.8 12.84 22.8 21.0 17.4 13.8 10.2 21.5 12.84 16.8 13.3 34.7 13.28 20.1 16.3 12.5 29.5 13.26 23.5 19.3 15.2 11.0 24.4 13.23 24.8 22.1 17.9 13.6 9.3 23.1 13.16 24.1 23.0 18.7 14.4 10.1 22.7 13.16 17.9 14.6 36.5 13.76 21.7 17.7 13.7 31.2 13.68 25.5 20.9 16.2 11.5 25.9 13.61 26.2 24.0 19.1 14.2 9.4 24.4 13.58 25.5 25.0 20.0 15.0 10.0 24.0 13.58 21.7 16.1 36.6 14.34 24.5 19.8 15.1 31.5 14.26 27.4 23.5 18.5 13.5 26.5 14.17 26.5 25.4 20.3 15.1 10.0 24.7 14.16 25.7 25.5 20.3 15.1 9.9 24.3 14.15 25.5 17.7 36.7 14.82 27.3 21.9 16.5 31.9 14.73 29.2 26.2 20.8 15.4 27.1 14.64 26.8 26.8 21.4 16.0 10.6 25.0 14.64 26.0 26.0 20.6 15.2 9.8 24.5 14.63 32 20.4 21.7 22.9 21.8 21.5 22.5 23.4 24.4 23.1 22.7 24.5 25.2 25.9 24.4 24.0 30.6 28.5 26.5 24.7 24.3 36.7 31.9 27.1 25.0 24.5 Sensible Capacity (kW) Return Dry Bulb (°C) 29 27 24 21 52°C 15.4 11.8 18.0 14.4 10.8 20.6 17.0 13.4 9.8 21.8 19.5 15.9 12.3 21.5 19.6 16.0 12.3 16.8 13.3 19.6 15.7 11.9 22.4 18.2 14.1 9.9 23.1 21.3 17.0 12.7 22.7 21.4 17.1 12.8 18.2 14.8 21.1 17.1 13.0 24.1 19.4 14.8 10.1 24.4 23.2 18.1 13.1 24.0 23.3 18.2 13.2 22.3 16.0 24.0 19.1 14.3 25.6 22.3 17.1 12.0 24.7 24.1 18.7 13.4 24.3 23.9 18.6 13.2 26.4 17.2 26.8 21.2 15.5 27.1 25.1 19.5 13.9 25.0 25.0 19.3 13.7 24.5 24.5 18.9 13.3 18 8.6 8.7 8.4 8.4 8.1 8.1 8.1 7.9 8.1 7.7 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. Capacity rating are based on 80 F (26.6 C) Entering Air Dry Bulb Temperature. 3. These ratings include the condenser fan motors, the compressor motors and supply air blower motor (External Static Pressure 0.30 IWG/ 74.7 Pa). 24 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF150 (12.5 Ton) Imperial Air on Evaporator Coil CFM 3750 4375 5000 5575 6150 3750 4375 5000 5575 6150 WB (°F) Total Capacity1,2 (MBh) Total Input (kW)3 90 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 185.6 168.8 151.9 146.1 141.4 190.5 173.2 155.9 149.9 145.1 195.4 177.6 159.9 153.8 148.8 200.8 182.6 164.3 158.0 152.9 206.2 187.5 168.8 162.3 157.0 11.34 11.18 11.02 10.96 10.92 11.63 11.47 11.31 11.25 11.21 11.89 11.73 11.57 11.51 11.47 12.68 12.52 12.36 12.30 12.26 13.46 13.30 13.14 13.08 13.04 82.4 104.3 126.3 145.6 141.4 85.8 112.8 139.8 149.7 145.1 89.2 121.3 153.4 153.8 148.8 93.4 127.2 161.0 158.0 152.9 97.6 133.1 168.6 162.3 157.0 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 155.6 142.6 129.5 122.3 120.6 160.3 146.9 133.4 126.0 124.2 165.0 151.1 137.3 129.7 127.8 167.9 153.8 139.8 132.0 130.1 170.9 156.5 142.2 134.3 132.4 13.79 13.67 13.56 13.49 13.48 14.08 13.96 13.84 13.78 13.76 14.34 14.22 14.10 14.04 14.03 15.11 14.99 14.87 14.81 14.80 15.87 15.75 15.63 15.57 15.56 76.4 96.8 117.3 122.2 120.6 81.9 104.0 126.2 125.9 124.2 87.3 111.2 135.1 129.7 127.8 98.2 118.4 138.6 132.0 130.1 109.2 125.6 142.1 134.3 132.4 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 85 80 75 70 65 85°F 66.9 51.4 170.6 12.56 88.8 73.3 57.8 155.7 12.43 110.8 95.2 79.7 64.2 140.7 12.29 122.7 106.4 90.9 75.4 59.8 134.2 12.23 133.8 116.3 100.8 85.3 69.8 131.0 12.20 71.6 55.5 175.4 12.85 96.0 79.2 62.4 160.0 12.71 120.4 102.9 85.4 67.8 144.7 12.57 136.9 115.0 96.9 78.9 60.9 138.0 12.51 141.3 125.7 107.3 88.9 70.4 134.6 12.48 76.3 59.6 180.2 13.12 103.2 85.1 67.0 164.4 12.98 130.1 110.6 91.0 71.5 148.6 12.84 151.0 123.5 103.0 82.5 61.9 141.7 12.78 148.8 135.1 113.8 92.4 71.1 138.3 12.75 80.3 60.9 184.3 13.90 107.0 86.9 66.7 168.2 13.76 133.8 112.9 92.0 71.1 152.0 13.62 156.7 126.7 105.3 83.9 62.5 145.0 13.55 152.9 139.2 117.4 95.6 73.8 141.5 13.53 84.3 62.1 188.5 14.67 110.9 88.6 66.4 172.0 14.53 137.4 115.1 92.9 70.6 155.5 14.39 162.3 129.8 107.5 85.3 63.1 148.3 14.32 157.0 143.3 121.1 98.8 76.6 144.7 14.30 105°F 61.4 46.4 140.6 15.02 81.8 66.8 51.8 129.5 14.92 102.3 87.3 72.3 57.3 118.3 14.83 114.6 100.4 85.4 70.4 55.4 110.5 14.76 118.0 104.9 89.9 74.9 59.9 110.2 14.76 65.0 50.0 145.2 15.30 88.0 72.0 56.0 133.7 15.20 111.1 94.0 77.0 60.0 122.2 15.11 121.7 108.1 90.6 73.2 55.7 114.1 15.04 122.9 113.0 95.2 77.4 59.6 113.8 15.04 68.6 53.5 149.8 15.56 94.2 77.1 60.1 137.9 15.47 119.8 100.8 81.7 62.7 126.0 15.37 128.8 115.8 95.9 76.0 56.1 117.7 15.30 127.8 121.1 100.5 79.9 59.3 117.3 15.30 73.7 55.6 151.5 16.32 99.3 80.1 60.9 139.5 16.23 124.8 104.6 84.5 64.3 127.5 16.13 131.6 119.7 99.1 78.5 57.9 119.0 16.06 130.1 124.5 103.5 82.6 61.6 118.7 16.06 78.9 57.6 153.2 17.07 104.4 83.1 61.8 141.1 16.98 129.8 108.5 87.2 65.9 128.9 16.88 134.3 123.5 102.2 80.9 59.6 120.4 16.81 132.4 127.8 106.5 85.2 63.9 120.0 16.82 90 79.4 100.6 121.8 133.9 131.0 83.8 108.4 133.0 137.8 134.6 88.3 116.3 144.3 141.7 138.3 95.8 122.8 149.8 145.0 141.5 103.4 129.4 155.3 148.3 144.7 73.4 93.1 112.8 110.5 110.2 79.9 99.6 119.4 114.1 113.8 86.4 106.2 126.0 117.7 117.3 100.6 114.1 127.5 119.0 118.7 114.9 121.9 128.9 120.4 120.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 95°F 64.1 48.9 85.3 70.1 54.8 106.5 91.3 76.0 60.7 118.6 103.4 88.1 72.9 125.9 110.6 95.4 80.1 68.3 52.7 92.0 75.6 59.2 115.8 98.5 81.2 63.9 129.3 111.5 93.8 76.0 132.1 119.4 101.3 83.2 72.4 56.6 98.7 81.1 63.5 125.0 105.7 86.4 67.1 139.9 119.7 99.5 79.2 138.3 128.1 107.1 86.2 77.0 58.2 103.2 83.5 63.8 129.3 108.7 88.2 67.7 144.1 123.2 102.2 81.2 141.5 131.8 110.5 89.1 81.6 59.9 107.6 85.8 64.1 133.6 111.8 90.0 68.3 148.3 126.6 104.9 83.1 144.7 135.6 113.8 92.0 115°F 58.6 43.9 78.4 63.6 48.9 98.1 83.3 68.6 53.8 110.5 97.4 82.6 67.9 110.2 99.2 84.5 69.8 61.7 47.2 84.0 68.4 52.8 106.4 89.6 72.8 56.1 114.1 104.7 87.5 70.3 113.8 106.7 89.2 71.7 64.7 50.5 89.7 73.2 56.7 114.7 95.9 77.1 58.3 117.7 112.0 92.4 72.8 117.3 114.2 93.9 73.7 70.5 52.9 95.4 76.7 58.1 120.3 100.5 80.7 60.9 119.0 116.2 96.0 75.8 118.7 117.1 96.6 76.0 76.2 55.4 101.1 80.3 59.5 126.0 105.2 84.4 63.6 120.4 120.4 99.5 78.7 120.0 120.0 99.2 78.4 65 57.6 64.9 58.3 65.0 59.0 65.2 60.2 67.7 61.3 70.3 53.1 55.0 53.2 54.2 53.2 53.5 55.6 55.5 57.9 57.6 25 862075-XTG-F-0513 ZF150 (12.5 Ton) Imperial (Continued) Air on Evaporator Coil CFM 3750 4375 5000 5575 6150 WB (°F) Total Capacity1,2 (MBh) Total Input (kW)3 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 77 72 67 62 57 136.5 125.7 115.0 104.8 104.5 140.9 129.8 118.7 108.2 107.9 145.4 133.9 122.4 111.7 111.3 146.6 135.5 124.3 112.9 112.6 147.9 137.0 126.1 114.2 113.9 15.57 15.43 15.28 15.16 15.16 15.85 15.71 15.58 15.45 15.45 16.10 15.97 15.85 15.71 15.71 16.85 16.74 16.62 16.47 16.47 17.59 17.49 17.38 17.22 17.22 Temperature of Air on Condenser Coil Sensible Capacity (MBh) Total Total Return Dry Bulb (°F) Capacity1,2 Input (MBh) (kW)3 90 85 80 75 70 65 118.4°F 71.2 56.3 41.4 128.4 16.65 91.0 76.1 61.3 46.4 118.5 16.41 110.9 96.0 81.1 66.2 51.3 108.5 16.17 104.8 104.8 96.2 81.3 66.4 51.5 93.9 15.95 104.5 104.5 97.3 82.4 67.5 52.6 93.6 15.95 78.2 59.1 44.5 132.6 16.91 97.4 81.6 65.9 50.1 122.3 16.70 116.7 104.2 87.2 70.2 53.2 112.0 16.48 108.2 108.2 104.1 86.7 69.2 51.8 96.9 16.23 107.9 107.9 105.8 88.1 70.5 52.8 96.6 16.23 85.2 62.0 47.7 136.9 17.15 103.8 87.2 70.5 53.8 126.2 16.96 122.4 112.3 93.3 74.2 55.2 115.5 16.77 111.7 111.7 112.1 92.1 72.0 52.0 100.0 16.50 111.3 111.3 114.3 93.9 73.4 53.0 99.7 16.49 99.5 68.2 50.4 137.2 17.88 111.9 92.9 73.9 54.9 127.6 17.72 124.3 117.6 97.4 77.3 57.1 118.1 17.57 112.9 112.9 113.2 92.5 71.8 51.2 101.1 17.26 112.6 112.6 114.1 93.2 72.4 51.5 100.8 17.26 113.7 74.4 53.1 137.5 18.60 119.9 98.6 77.3 56.0 129.1 18.48 126.1 122.9 101.6 80.3 59.0 120.7 18.35 114.2 114.2 114.2 92.9 71.6 50.3 102.3 18.01 113.9 113.9 113.9 92.6 71.3 50.0 102.0 18.01 90 67.0 87.0 107.1 93.9 93.6 75.0 93.1 111.3 96.9 96.6 83.0 99.2 115.5 100.0 99.7 97.2 107.6 118.1 101.1 100.8 111.4 116.0 120.7 102.3 102.0 Sensible Capacity (MBh) Return Dry Bulb (°F) 85 80 75 70 125°F 51.9 36.7 71.9 56.7 41.5 91.9 76.7 61.5 46.4 93.9 93.9 78.7 63.5 93.6 93.6 78.4 63.2 54.3 39.4 77.1 61.0 44.9 99.9 82.5 65.1 47.8 96.9 103.1 85.1 67.0 96.6 104.1 86.1 68.1 56.6 42.2 82.2 65.2 48.2 107.8 88.3 68.7 49.2 100.0 112.3 91.4 70.5 99.7 114.6 93.7 72.9 63.7 45.4 88.0 68.4 48.8 112.3 91.4 70.5 49.6 101.1 107.3 85.7 64.2 100.8 108.3 86.7 65.2 70.8 48.6 93.8 71.6 49.3 116.8 94.6 72.3 50.1 102.3 102.3 80.0 57.8 102.0 102.0 79.7 57.5 65 48.3 48.1 49.0 50.0 49.7 52.0 42.6 43.6 35.6 35.2 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. Capacity rating are based on 80 F (26.6 C) Entering Air Dry Bulb Temperature. 3. These ratings include the condenser fan motors, the compressor motors and supply air blower motor (External Static Pressure 0.35 IWG/ 87.1 Pa). 26 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF150 (44 kW) Metric Air on Evaporator Coil 3 m /s 1.77 2.06 2.36 2.63 2.90 1.77 2.06 2.36 2.63 2.90 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 54.4 49.5 44.5 42.8 41.4 55.8 50.8 45.7 43.9 42.5 57.3 52.1 46.9 45.1 43.6 58.8 53.5 48.2 46.3 44.8 60.4 54.9 49.5 47.6 46.0 11.34 11.18 11.02 10.96 10.92 11.63 11.47 11.31 11.25 11.21 11.89 11.73 11.57 11.51 11.47 12.68 12.52 12.36 12.30 12.26 13.46 13.30 13.14 13.08 13.04 24.1 30.6 37.0 42.7 41.4 25.2 33.1 41.0 43.9 42.5 26.2 35.6 45.0 45.1 43.6 27.4 37.3 47.2 46.3 44.8 28.6 39.0 49.4 47.6 46.0 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 45.6 41.8 38.0 35.9 35.3 47.0 43.0 39.1 36.9 36.4 48.4 44.3 40.2 38.0 37.5 49.2 45.1 41.0 38.7 38.1 50.1 45.9 41.7 39.4 38.8 11.34 11.18 11.02 10.96 10.92 11.63 11.47 11.31 11.25 11.21 11.89 11.73 11.57 11.51 11.47 12.68 12.52 12.36 12.30 12.26 13.46 13.30 13.14 13.08 13.04 22.4 28.4 34.4 35.8 35.3 24.0 30.5 37.0 36.9 36.4 25.6 32.6 39.6 38.0 37.5 28.8 34.7 40.6 38.7 38.1 32.0 36.8 41.7 39.4 38.8 Johnson Controls Unitary Products Temperature of Air on Condenser Coil Sensible Capacity (kW) Total Total Return Dry Bulb (°C) Capacity1,2 Input (kW) (kW)3 29 27 24 21 18 29°C 19.6 15.1 50.0 12.56 26.0 21.5 16.9 45.6 12.43 32.5 27.9 23.4 18.8 41.2 12.29 36.0 31.2 26.6 22.1 17.5 39.3 12.23 39.2 34.1 29.6 25.0 20.5 38.4 12.20 21.0 16.3 51.4 12.85 28.1 23.2 18.3 46.9 12.71 35.3 30.2 25.0 19.9 42.4 12.57 40.1 33.7 28.4 23.1 17.8 40.4 12.51 41.4 36.8 31.4 26.0 20.6 39.5 12.48 22.4 17.5 52.8 13.12 30.2 24.9 19.6 48.2 12.98 38.1 32.4 26.7 20.9 43.6 12.84 44.3 36.2 30.2 24.2 18.1 41.5 12.78 43.6 39.6 33.3 27.1 20.8 40.5 12.75 23.5 17.8 54.0 13.90 31.4 25.5 19.5 49.3 13.76 39.2 33.1 27.0 20.8 44.6 13.62 45.9 37.1 30.9 24.6 18.3 42.5 13.55 44.8 40.8 34.4 28.0 21.6 41.5 13.53 24.7 18.2 55.2 14.67 32.5 26.0 19.5 50.4 14.53 40.3 33.7 27.2 20.7 45.6 14.39 47.6 38.0 31.5 25.0 18.5 43.5 14.32 46.0 42.0 35.5 29.0 22.4 42.4 14.30 41°C 18.0 13.6 41.2 15.02 24.0 19.6 15.2 37.9 14.92 30.0 25.6 21.2 16.8 34.7 14.83 33.6 29.4 25.0 20.6 16.2 32.4 14.76 34.6 30.8 26.4 22.0 17.6 32.3 14.76 19.0 14.6 42.6 15.30 25.8 21.1 16.4 39.2 15.20 32.5 27.6 22.6 17.6 35.8 15.11 35.7 31.7 26.6 21.5 16.3 33.4 15.04 36.0 33.1 27.9 22.7 17.5 33.3 15.04 20.1 15.7 43.9 15.56 27.6 22.6 17.6 40.4 15.47 35.1 29.5 24.0 18.4 36.9 15.37 37.7 34.0 28.1 22.3 16.4 34.5 15.30 37.5 35.5 29.5 23.4 17.4 34.4 15.30 21.6 16.3 44.4 16.32 29.1 23.5 17.9 40.9 16.23 36.6 30.7 24.8 18.8 37.4 16.13 38.6 35.1 29.0 23.0 17.0 34.9 16.06 38.1 36.5 30.3 24.2 18.1 34.8 16.06 23.1 16.9 44.9 17.07 30.6 24.3 18.1 41.3 16.98 38.0 31.8 25.6 19.3 37.8 16.88 39.4 36.2 30.0 23.7 17.5 35.3 16.81 38.8 37.5 31.2 25.0 18.7 35.2 16.82 32 23.3 29.5 35.7 39.2 38.4 24.6 31.8 39.0 40.4 39.5 25.9 34.1 42.3 41.5 40.5 28.1 36.0 43.9 42.5 41.5 30.3 37.9 45.5 43.5 42.4 21.5 27.3 33.1 32.4 32.3 23.4 29.2 35.0 33.4 33.3 25.3 31.1 36.9 34.5 34.4 29.5 33.4 37.4 34.9 34.8 33.7 35.7 37.8 35.3 35.2 Sensible Capacity (kW) Return Dry Bulb (°C) 29 27 24 21 35°C 18.8 14.3 25.0 20.5 16.1 31.2 26.7 22.3 17.8 34.8 30.3 25.8 21.4 36.9 32.4 28.0 23.5 20.0 15.5 27.0 22.2 17.3 33.9 28.9 23.8 18.7 37.9 32.7 27.5 22.3 38.7 35.0 29.7 24.4 21.2 16.6 28.9 23.8 18.6 36.6 31.0 25.3 19.7 41.0 35.1 29.2 23.2 40.5 37.5 31.4 25.3 22.6 17.1 30.2 24.5 18.7 37.9 31.9 25.9 19.8 42.2 36.1 29.9 23.8 41.5 38.6 32.4 26.1 23.9 17.5 31.5 25.2 18.8 39.2 32.8 26.4 20.0 43.5 37.1 30.7 24.4 42.4 39.7 33.3 27.0 46°C 17.2 12.9 23.0 18.6 14.3 28.7 24.4 20.1 15.8 32.4 28.5 24.2 19.9 32.3 29.1 24.8 20.4 18.1 13.8 24.6 20.0 15.5 31.2 26.3 21.3 16.4 33.4 30.7 25.6 20.6 33.3 31.3 26.1 21.0 19.0 14.8 26.3 21.4 16.6 33.6 28.1 22.6 17.1 34.5 32.8 27.1 21.3 34.4 33.5 27.5 21.6 20.6 15.5 28.0 22.5 17.0 35.3 29.5 23.7 17.9 34.9 34.0 28.1 22.2 34.8 34.3 28.3 22.3 22.3 16.2 29.6 23.5 17.4 36.9 30.8 24.7 18.6 35.3 35.3 29.2 23.1 35.2 35.2 29.1 23.0 18 16.9 19.0 17.1 19.1 17.3 19.1 17.6 19.9 18.0 20.6 15.6 16.1 15.6 15.9 15.6 15.7 16.3 16.3 17.0 16.9 27 862075-XTG-F-0513 ZF150 (44 kW) Metric (Continued) Air on Evaporator Coil m3/s 1.77 2.06 2.36 2.63 2.90 WB (°C) Total Capacity1,2 (kW) Total Input (kW)3 32 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 25 22 19 17 14 40.0 36.8 33.7 30.7 30.6 41.3 38.0 34.8 31.7 31.6 42.6 39.2 35.9 32.7 32.6 43.0 39.7 36.4 33.1 33.0 43.3 40.1 37.0 33.5 33.4 15.57 15.43 15.28 15.16 15.16 15.85 15.71 15.58 15.45 15.45 16.10 15.97 15.85 15.71 15.71 16.85 16.74 16.62 16.47 16.47 17.59 17.49 17.38 17.22 17.22 20.9 26.7 32.5 30.7 30.6 22.9 28.6 34.2 31.7 31.6 25.0 30.4 35.9 32.7 32.6 29.2 32.8 36.4 33.1 33.0 33.3 35.1 37.0 33.5 33.4 Temperature of Air on Condenser Coil Sensible Capacity (kW) Total Total Return Dry Bulb (°C) Capacity1,2 Input (kW) (kW)3 29 27 24 21 18 48°C 16.5 12.1 37.6 16.65 22.3 18.0 13.6 34.7 16.41 28.1 23.8 19.4 15.0 31.8 16.17 30.7 28.2 23.8 19.5 15.1 27.5 15.95 30.6 28.5 24.2 19.8 15.4 27.4 15.95 17.3 13.1 38.9 16.91 23.9 19.3 14.7 35.9 16.70 30.5 25.6 20.6 15.6 32.8 16.48 31.7 30.5 25.4 20.3 15.2 28.4 16.23 31.6 31.0 25.8 20.7 15.5 28.3 16.23 18.2 14.0 40.1 17.15 25.5 20.7 15.8 37.0 16.96 32.9 27.3 21.8 16.2 33.9 16.77 32.7 32.9 27.0 21.1 15.2 29.3 16.50 32.6 33.5 27.5 21.5 15.5 29.2 16.49 20.0 14.8 40.2 17.88 27.2 21.7 16.1 37.4 17.72 34.5 28.6 22.6 16.7 34.6 17.57 33.1 33.2 27.1 21.1 15.0 29.6 17.26 33.0 33.4 27.3 21.2 15.1 29.5 17.26 21.8 15.6 40.3 18.60 28.9 22.7 16.4 37.8 18.48 36.0 29.8 23.5 17.3 35.4 18.35 33.5 33.5 27.2 21.0 14.7 30.0 18.01 33.4 33.4 27.1 20.9 14.7 29.9 18.01 32 19.6 25.5 31.4 27.5 27.4 22.0 27.3 32.6 28.4 28.3 24.3 29.1 33.9 29.3 29.2 28.5 31.5 34.6 29.6 29.5 32.6 34.0 35.4 30.0 29.9 Sensible Capacity (kW) Return Dry Bulb (°C) 29 27 24 21 52°C 15.2 10.8 21.1 16.6 12.2 26.9 22.5 18.0 13.6 27.5 27.5 23.1 18.6 27.4 27.4 23.0 18.5 15.9 11.6 22.6 17.9 13.2 29.3 24.2 19.1 14.0 28.4 30.2 24.9 19.6 28.3 30.5 25.2 19.9 16.6 12.4 24.1 19.1 14.1 31.6 25.9 20.1 14.4 29.3 32.9 26.8 20.7 29.2 33.6 27.5 21.4 18.7 13.3 25.8 20.0 14.3 32.9 26.8 20.7 14.5 29.6 31.4 25.1 18.8 29.5 31.7 25.4 19.1 20.7 14.2 27.5 21.0 14.5 34.2 27.7 21.2 14.7 30.0 30.0 23.5 16.9 29.9 29.9 23.4 16.8 18 14.2 14.1 14.4 14.7 14.6 15.2 12.5 12.8 10.4 10.3 1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. Capacity rating are based on 80 F (26.6 C) Entering Air Dry Bulb Temperature. 3. These ratings include the condenser fan motors, the compressor motors and supply air blower motor (External Static Pressure 0.35 IWG/ 87.1 Pa). 28 Johnson Controls Unitary Products 862075-XTG-F-0513 Airflow Performance ZF090-150 Side Duct Application ZF090 (7.5 Ton) Standard Motor Side Duct Imperial Turns Open ESP (iwg) 0 CFM Watts 1 BHP CFM Watts 2 BHP CFM Watts 3 BHP CFM Watts 4 BHP CFM Watts 5 BHP CFM Watts BHP 0.2 – – – – – – – – – – – – 3193 1490 1.60 2981 1310 1.41 0.4 3690 2230 2.39 3468 1950 2.09 3294 1750 1.88 3105 1550 1.66 2922 1370 1.47 2694 1210 1.30 0.6 3478 2110 2.26 3239 1830 1.96 3044 1640 1.76 2850 1440 1.54 2651 1270 1.36 2423 1120 1.20 0.8 3243 1980 2.12 3001 1720 1.85 2790 1520 1.63 2576 1330 1.43 2370 1170 1.26 2105 1020 1.09 1.0 3006 1830 1.96 2758 1580 1.70 2544 1400 1.50 2303 1230 1.32 2017 1050 1.13 1624 880 0.94 1.2 2758 1720 1.85 2533 1510 1.62 2230 1290 1.38 1891 1080 1.16 – – – – – – 1.4 2447 1570 1.68 2182 1350 1.45 1769 1110 1.19 – – – – – – – – – 1.6 2085 1410 1.51 – – – – – – – – – – – – – – – ZF090 (26 kW) Standard Motor Side Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In Out m3/s In Out m3/s In Out m3/s In Out m3/s In Out m3/s In Out 50 – – – – – – – – – – – – 1.51 1.49 1.19 1.36 1.31 1.05 100 1.74 2.23 1.78 1.64 1.95 1.55 1.55 1.75 1.40 1.46 1.55 1.24 1.38 1.37 1.10 1.27 1.21 0.97 149 1.64 2.11 1.68 1.53 1.83 1.46 1.44 1.64 1.39 1.34 1.44 1.15 1.25 1.27 1.01 1.14 1.12 0.89 199 1.53 1.98 1.58 1.42 1.72 1.38 1.32 1.52 1.38 1.22 1.33 1.07 1.12 1.17 0.94 0.99 1.02 0.81 249 1.42 1.83 1.46 1.30 1.58 1.27 1.20 1.40 1.28 1.09 1.23 0.98 0.95 1.05 0.84 0.77 0.88 0.70 299 1.30 1.72 1.38 1.20 1.51 1.21 1.05 1.29 1.17 0.89 1.08 0.91 – – – – – – 349 1.15 1.57 1.25 1.03 1.35 1.08 0.83 1.11 1.01 – – – – – – – – – 399 0.98 1.41 1.26 – – – – – – – – – – – – – – – ZF090 (7.5) Ton Optional Motor Side Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.25 – – – – – – – – – – – – 3650 1800 1.95 3290 1560 1.68 0.5 – – – – – – – – – – – – 3250 1650 1.78 2930 1430 1.53 0.8 – – – – – – – – – – – – 2783 1500 1.61 2507 1300 1.39 1 3555 2440 2.62 3285 2120 2.27 3047 1860 2.00 2778 1590 1.71 2507 1390 1.49 2209 1180 1.27 1.2 3320 2310 2.48 3034 1990 2.13 2799 1730 1.86 2510 1480 1.59 2213 1260 1.35 1846 1050 1.13 1.4 3101 2160 2.32 2796 1860 2.00 2466 1590 1.71 2188 1330 1.43 1721 1090 1.17 – – – 1.6 2864 2040 2.19 2489 1710 1.83 2145 1450 1.56 – – – – – – – – – 1.8 2524 1860 2.00 2182 1550 1.66 – – – – – – – – – – – – 2 2189 1680 1.80 – – – – – – – – – – – – – – – Johnson Controls Unitary Products 29 862075-XTG-F-0513 ZF090 (26 kW) Optional Motor Side Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 62 – – – – – – – – – – – – 1.72 1.8 1.46 1.55 1.56 1.25 125 – – – – – – – – – – – – 1.53 1.65 1.33 1.38 1.43 1.14 199 – – – – – – – – – – – – 1.31 1.5 1.20 1.18 1.3 1.04 249 1.68 2.44 1.95 1.55 2.12 1.70 1.44 1.86 1.49 1.31 1.59 1.27 1.18 1.39 1.11 1.04 1.18 0.94 299 1.52 2.31 1.85 1.43 1.99 1.59 1.32 1.73 1.38 1.18 1.48 1.18 1.04 1.26 1.01 0.87 1.05 0.84 349 1.46 2.16 1.73 1.31 1.86 1.49 1.16 1.59 1.27 1.03 1.33 1.06 0.81 1.09 0.87 – – – 399 1.35 2.04 1.63 1.17 1.71 1.36 1.01 1.45 1.16 – – – – – – – – – 448 1.19 1.86 1.49 1.03 1.55 1.24 – – – – – – – – – – – – 498 1.03 1.68 1.34 – – – – – – – – – – – – – – – ZF120 (10 Ton) Standard Motor Side Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.35 4820 2675 2.87 4582 2362 2.53 4319 2080 2.23 4086 1842 1.98 3863 1648 1.77 3590 1430 1.53 0.6 4522 2496 2.68 4307 2215 2.38 4025 1941 2.08 3713 1678 1.80 3464 1499 1.61 3149 1291 1.38 0.8 4223 2332 2.50 3973 2062 2.21 3656 1783 1.91 3363 1550 1.66 3026 1350 1.45 - - - 1.0 3913 2174 2.33 3679 1923 2.06 3262 1619 1.74 2721 1330 1.43 - - - - - - 1.2 3521 1978 2.12 3104 1693 1.82 - - - - - - - - - - - - 1.4 2790 1660 1.78 - - - - - - - - - - - - - - - ZF120 (35 kW) Standard Motor Side Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 87 2.27 2.68 2.14 2.16 2.36 1.89 2.04 2.08 1.66 1.93 1.84 1.47 1.82 1.65 1.32 1.69 1.43 1.14 149 2.13 2.50 2.00 2.03 2.22 1.77 1.90 1.94 1.55 1.75 1.68 1.34 1.63 1.50 1.20 1.49 1.29 1.03 199 1.99 2.33 1.87 1.88 2.06 1.65 1.73 1.78 1.43 1.59 1.55 1.24 1.43 1.35 1.08 - - - 249 1.85 2.17 1.74 1.74 1.92 1.54 1.54 1.62 1.30 1.28 1.33 1.06 - - - - - - 299 1.66 1.98 1.58 1.46 1.69 1.35 - - - - - - - - - - - - 349 1.32 1.66 1.33 - - - - - - - - - - - - - - - 30 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF120 (10 Ton) Optional Motor Side Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.35 - - - - - - - - - - - - - - - 5100 2495 2.68 0.6 - - - - - - - - - - - - 5091 2745 2.94 4646 2314 2.48 0.8 - - - - - - - - - 5078 2937 3.15 4839 2584 2.77 4347 2153 2.31 1.0 - - - - - - 5075 3117 3.34 4767 2730 2.93 4487 2377 2.55 3946 1942 2.08 1.2 - - - 5068 3308 3.55 4742 2881 3.09 4427 2513 2.69 4108 2159 2.32 3501 1723 1.85 1.4 5079 3595 3.86 4787 3105 3.33 4452 2713 2.91 4012 2259 2.42 3665 1926 2.07 - - - 1.6 4739 3316 3.56 4482 2892 3.10 4098 2474 2.65 3543 2006 2.15 3057 1642 1.76 - - - 1.8 4461 3111 3.34 4070 2621 2.81 3552 2160 2.32 - - - - - - - - - 2.0 3997 2782 2.98 3400 2219 2.38 - - - - - - - - - - - - 2.2 3496 2480 2.66 - - - - - - - - - - - - - - - ZF120 (35 kW) Optional Motor Side Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 87 - - - - - - - - - - - - - - - 2.4 2.50 2.00 149 - - - - - - - - - - - - 2.40 2.75 2.20 2.19 2.31 1.85 199 - - - - - - - - - 2.40 2.94 2.35 2.28 2.58 2.07 2.05 2.15 1.72 249 - - - - - - 2.40 3.12 2.49 2.25 2.73 2.18 2.12 2.38 1.90 1.86 1.94 1.55 299 - - - 2.39 3.31 2.65 2.24 2.88 2.30 2.09 2.51 2.01 1.94 2.16 1.73 1.65 1.72 1.38 349 2.40 3.60 2.88 2.26 3.11 2.48 2.10 2.71 2.17 1.89 2.26 1.81 1.73 1.93 1.54 - - - 399 2.24 3.32 2.65 2.12 2.89 2.31 1.93 2.47 1.98 1.67 2.01 1.60 1.44 1.64 1.31 - - - 448 2.11 3.11 2.49 1.92 2.62 2.10 1.68 2.16 1.73 - - - - - - - - - 498 1.89 2.78 2.23 1.60 2.22 1.78 - - - - - - - - - - - - 548 1.65 2.48 1.98 - - - - - - - - - - - - - - - Johnson Controls Unitary Products 31 862075-XTG-F-0513 ZF150 (12.5 Ton) Side Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.35 - - - 6150 4171 4.47 5915 3774 4.05 5610 3309 3.55 5396 2948 3.16 4960 2495 2.68 0.6 - - - 5850 3932 4.22 5648 3565 3.82 5363 3136 3.36 5091 2745 2.94 4646 2314 2.48 0.8 5870 4273 4.58 5567 3715 3.98 5406 3380 3.62 5078 2937 3.15 4839 2584 2.77 4347 2153 2.31 1.0 5652 4087 4.38 5327 3518 3.77 5075 3117 3.34 4767 2730 2.93 4487 2377 2.55 3946 1942 2.08 1.2 5350 3820 4.10 5068 3308 3.55 4742 2881 3.09 4427 2513 2.69 4108 2159 2.32 - - - 1.4 5079 3595 3.86 4787 3105 3.33 4452 2713 2.91 4012 2259 2.42 3665 1926 2.07 - - - 1.6 4739 3316 3.56 4482 2892 3.10 4098 2474 2.65 - - - - - - - - - 1.8 4461 3111 3.34 4070 2621 2.81 - - - - - - - - - - - - 2.0 3997 2782 2.98 - - - - - - - - - - - - - - - ZF150 (44 kW) Side Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 87 - - - 2.90 4.17 3.34 2.79 3.77 3.02 2.65 3.31 2.65 2.55 2.95 2.36 2.34 2.50 2.00 149 - - - 2.76 3.93 3.15 2.67 3.57 2.85 2.53 3.14 2.51 2.40 2.75 2.20 2.19 2.31 1.85 199 2.77 4.27 3.42 2.63 3.72 2.97 2.55 3.38 2.70 2.40 2.94 2.35 2.28 2.58 2.07 2.05 2.15 1.72 249 2.67 4.09 3.27 2.51 3.52 2.81 2.40 3.12 2.49 2.25 2.73 2.18 2.12 2.38 1.90 1.86 1.94 1.55 299 2.52 3.82 3.06 2.39 3.31 2.65 2.24 2.88 2.30 2.09 2.51 2.01 1.94 2.16 1.73 - - - 349 2.40 3.60 2.88 2.26 3.11 2.48 2.10 2.71 2.17 1.89 2.26 1.81 1.73 1.93 1.54 - - - 399 2.24 3.32 2.65 2.12 2.89 2.31 1.93 2.47 1.98 - - - - - - - - - 448 2.11 3.11 2.49 1.92 2.62 2.10 - - - - - - - - - - - 498 1.89 2.78 2.23 - - - - - - - - - - - - - - 32 - Johnson Controls Unitary Products 862075-XTG-F-0513 ZF090-150 Bottom Duct Application ZF090 (7.5 Ton) Standard Motor Bottom Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.2 3478 2110 2.26 3239 1830 1.96 3044 1640 1.76 2850 1440 1.54 2651 1270 1.36 2423 1120 1.20 0.4 3243 1980 2.12 3001 1720 1.85 2790 1520 1.63 2576 1330 1.43 2370 1170 1.26 2105 1020 1.09 0.6 3006 1830 1.96 2758 1580 1.70 2544 1400 1.50 2303 1230 1.32 2017 1050 1.13 1624 880 0.94 0.8 2758 1720 1.85 2533 1510 1.62 2230 1290 1.38 1891 1080 1.16 – – – – – – 1.0 2447 1570 1.68 2182 1350 1.45 1769 1110 1.19 – – – – – – – – – 1.2 2085 1410 1.51 – – – – – – – – – – – – – – – ZF090 (26 kW) Standard Motor Bottom Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 50 1.64 2.11 1.68 1.53 1.83 1.46 1.44 1.64 1.39 1.34 1.44 1.15 1.25 1.27 1.01 1.14 1.12 0.89 100 1.53 1.98 1.58 1.42 1.72 1.38 1.32 1.52 1.38 1.22 1.33 1.07 1.12 1.17 0.94 0.99 1.02 0.81 149 1.42 1.83 1.46 1.30 1.58 1.27 1.20 1.40 1.28 1.09 1.23 0.98 0.95 1.05 0.84 0.77 0.88 0.70 199 1.30 1.72 1.38 1.20 1.51 1.21 1.05 1.29 1.17 0.89 1.08 0.91 – – – – – – 249 1.15 1.57 1.25 1.03 1.35 1.08 0.83 1.11 1.01 – – – – – – – – – 299 0.98 1.41 1.26 – – – – – – – – – – – – – – – ZF090 (7.5 Ton) Optional Motor Bottom Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.4 – – – – – – – – – – – – 2783 1500 1.61 2507 1300 1.39 0.6 – – – 3285 2120 2.27 3047 1860 2.00 2778 1590 1.71 2507 1390 1.49 2209 1180 1.27 0.8 – – – 3034 1990 2.13 2799 1730 1.86 2510 1480 1.59 2213 1260 1.35 1846 1050 1.13 1.0 3101 2160 2.32 2796 1860 2.00 2466 1590 1.71 2188 1330 1.43 1721 1090 1.17 – – – 1.2 2864 2040 2.19 2489 1710 1.83 2145 1450 1.56 – – – – – – – – – 1.4 2524 1860 2.00 2182 1550 1.66 – – – – – – – – – – – – 1.6 2189 1680 1.80 – – – – – – – – – – – – – – – Johnson Controls Unitary Products 33 862075-XTG-F-0513 ZF090 (26 kW) Optional Motor Bottom Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 100 – – – – – – – – – – – – 1.31 1.5 1.20 1.18 1.3 1.04 149 1.67 2.44 1.95 1.55 2.12 1.70 1.44 1.86 1.49 1.31 1.59 1.27 1.18 1.39 1.11 1.04 1.18 0.94 199 1.57 2.31 1.85 1.43 1.99 1.59 1.32 1.73 1.38 1.18 1.48 1.18 1.04 1.26 1.01 0.87 1.05 0.84 249 1.46 2.16 1.73 1.31 1.86 1.49 1.16 1.59 1.27 1.03 1.33 1.06 0.81 1.09 0.87 – – – 299 1.35 2.04 1.63 1.17 1.71 1.36 1.01 1.45 1.16 – – – – – – – – – 349 1.19 1.86 1.49 1.03 1.55 1.24 – – – – – – – – – – – – 399 1.03 1.68 1.34 – – – – – – – – – – – – – – – ZF120 (10 Ton) Standard Motor Bottom Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.2 4543 2511 2.69 4362 2250 2.41 4139 1996 2.14 3911 1766 1.89 3719 1594 1.71 3518 1407 1.51 0.4 4311 2381 2.55 4115 2127 2.28 3862 1871 2.01 3611 1644 1.76 3386 1471 1.58 3153 1293 1.39 0.6 4032 2232 2.39 3804 1982 2.13 3508 1720 1.84 3246 1506 1.61 2971 1332 1.43 - - - 0.8 3706 2068 2.22 3428 1818 1.95 3078 1548 1.66 - - - - - - - - - 1.0 3333 1892 2.03 2989 1644 1.76 - - - - - - - - - - - - 1.2 2914 1711 1.83 - - - - - - - - - - - - - - - ZF120 (35 kW) Standard Motor Bottom Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 50 2.14 2.51 2.01 2.06 2.25 1.80 1.95 2.00 1.60 1.85 1.77 1.41 1.75 1.59 1.27 1.66 1.41 1.13 100 2.03 2.38 1.91 1.94 2.13 1.70 1.82 1.87 1.50 1.70 1.64 1.31 1.60 1.47 1.18 1.49 1.29 1.03 149 1.90 2.23 1.79 1.80 1.98 1.59 1.66 1.72 1.38 1.53 1.51 1.20 1.40 1.33 1.07 - - - 199 1.75 2.07 1.65 1.62 1.82 1.45 1.45 1.55 1.24 - - - - - - - - - 249 1.57 1.89 1.51 1.41 1.64 1.32 - - - - - - - - - - - - 299 1.38 1.71 1.37 - - - - - - - - - - - - - - 34 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF120 (10 Ton) Optional Motor Bottom Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.2 - - - - - - - - - - - - 4966 2666 2.86 4605 2290 2.46 0.4 - - - - - - - - - 4919 2473 2.65 4721 2515 2.70 4344 2145 2.30 0.6 - - - - - - 4929 3022 3.24 4665 2324 2.49 4450 2353 2.52 4048 1991 2.13 0.8 - - - 4908 3197 3.43 4668 2841 3.05 4391 2171 2.33 4151 2183 2.34 3717 1829 1.96 1.0 4915 3456 3.71 4651 3013 3.23 4388 2656 2.85 4096 2015 2.16 3825 2008 2.15 3352 1664 1.78 1.2 4653 3253 3.49 4377 2823 3.03 4089 2467 2.65 3779 1858 1.99 3471 1830 1.96 2951 1499 1.61 1.4 4372 3046 3.27 4087 2631 2.82 3771 2277 2.44 3442 1703 1.83 3090 1652 1.77 - - - 1.6 4070 2837 3.04 3780 2437 2.61 3434 2089 2.24 3084 1552 1.66 - - - - - - 1.8 3748 2629 2.82 3455 2243 2.41 3078 1904 2.04 - - - - - - - - - 2.0 3406 2425 2.60 3114 2051 2.20 - - - - - - - - - - - - 2.2 3044 2228 2.39 - - - - - - - - - - - - - - - ZF120 (35 kW) Optional Motor Bottom Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 50 - - - - - - - - - - - - 2.34 2.67 2.13 2.17 2.29 1.83 100 - - - - - - - - - 2.32 2.47 1.98 2.23 2.51 2.01 2.05 2.15 1.72 149 - - - - - - 2.33 3.02 2.42 2.20 2.32 1.86 2.10 2.35 1.88 1.91 1.99 1.59 199 - - - 2.32 3.20 2.56 2.20 2.84 2.27 2.07 2.17 1.74 1.96 2.18 1.75 1.75 1.83 1.46 249 2.32 3.46 2.76 2.20 3.01 2.41 2.07 2.66 2.12 1.93 2.01 1.61 1.81 2.01 1.61 1.58 1.66 1.33 299 2.20 3.25 2.60 2.07 2.82 2.26 1.93 2.47 1.97 1.78 1.86 1.49 1.64 1.83 1.46 1.39 1.50 1.20 349 2.06 3.05 2.44 1.93 2.63 2.10 1.78 2.28 1.82 1.62 1.70 1.36 1.46 1.65 1.32 - - - 399 1.92 2.84 2.27 1.78 2.44 1.95 1.62 2.09 1.67 1.46 1.55 1.24 - - - - - - 448 1.77 2.63 2.10 1.63 2.24 1.79 1.45 1.90 1.52 - - - - - - - - - 498 1.61 2.43 1.94 1.47 2.05 1.64 - - - - - - - - - - - - 548 1.44 2.23 1.78 - - - - - - - - - - - - - - - Johnson Controls Unitary Products 35 862075-XTG-F-0513 ZF150 (12.5 Ton) Bottom Duct Imperial Turns Open ESP (iwg) 0 1 2 3 4 5 CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP CFM Watts BHP 0.35 5576 4015 4.32 5370 3547 3.80 5171 3197 3.43 5007 2884 3.09 4721 2515 2.70 4344 2145 2.30 0.6 5376 3839 4.12 5147 3376 3.62 4929 3022 3.24 4735 2704 2.90 4450 2353 2.52 4048 1991 2.13 0.8 5155 3652 3.92 4908 3197 3.43 4668 2841 3.05 4411 2501 2.68 4151 2183 2.34 3717 1829 1.96 1.0 4915 3456 3.71 4651 3013 3.23 4388 2656 2.85 4035 2281 2.45 3825 2008 2.15 - - - 1.2 4653 3253 3.49 4377 2823 3.03 4089 2467 2.65 3608 2051 2.20 - - - - - - 1.4 4372 3046 3.27 4087 3621 2.82 3771 2277 2.44 - - - - - - - - - 1.6 4070 2837 3.04 3780 2437 2.61 - - - - - - - - - - - - 1.8 3748 2629 2.82 - - - - - - - - - - - - - - - ZF150 (44 kW) Bottom Duct Metric Turns Open ESP (Pa) 0 1 2 3 4 5 m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) m3/s In (kW) Out (kW) 87 2.63 4.01 3.21 2.53 3.55 2.84 2.44 3.20 2.56 2.36 2.88 2.31 2.23 2.51 2.01 2.05 2.15 1.72 149 2.54 3.84 3.07 2.43 3.38 2.70 2.33 3.02 2.42 2.23 2.70 2.16 2.10 2.35 1.88 1.91 1.99 1.59 199 2.43 3.65 2.92 2.32 3.20 2.56 2.20 2.84 2.27 2.08 2.50 2.00 1.96 2.18 1.75 1.75 1.83 1.46 249 2.32 3.46 2.76 2.20 3.01 2.41 2.07 2.66 2.12 1.90 2.28 1.83 1.81 2.01 1.61 - - - 299 2.20 3.25 2.60 2.07 2.82 2.26 1.93 2.47 1.97 1.70 2.05 1.64 - - - - - - 349 2.06 3.05 2.44 1.93 2.63 2.10 1.78 2.28 1.82 - - - - - - - - - 399 1.92 2.84 2.27 1.78 2.44 1.95 - - - - - - - - - - - - 448 1.77 2.63 2.10 - - - - - - - - - - - - - - - NOTES FOR TABLES ON PAGES 30 THROUGH 37: • • “Turns Open” refers to the setting of the variable pitch motor sheave, where “0 Turns Open” is fully closed. Blower performance includes dry coil and 2” (51mm) throwaway filters. • Blower performance for gas heat includes the maximum number of heat tubes available for each tonnage. • ESP (External Static Pressure) given is that available for the supply and return air duct system. All internal resistances have been deducted from the total static pressure of the blower. Rated Airflow Imperial 36 Model CFM ESP (iwg) ZF090 3650 0.2 ZF120 5000 0.3 ZF150 6250 0.3 Johnson Controls Unitary Products 862075-XTG-F-0513 Additional Static Resistance ZF120/150 Cabinet (IMPERIAL) CFM Cooling Only1 Economizer2 3 1900 0.06 2100 0.07 2300 0.08 2500 2700 Electric Heat KW2 18 24 36 54 0.02 0.06 0.07 0.08 0.10 0.02 0.07 0.08 0.09 0.11 0.02 0.08 0.09 0.10 0.13 0.09 0.02 0.09 0.10 0.11 0.14 0.11 0.03 0.10 0.12 0.13 0.16 2900 0.12 0.03 0.11 0.13 0.14 0.18 3100 0.14 0.03 0.13 0.15 0.16 0.20 3300 0.16 0.03 0.14 0.17 0.18 0.22 3500 0.18 0.04 0.16 0.19 0.20 0.24 3700 0.20 0.04 0.18 0.21 0.22 0.26 3900 0.23 0.04 0.20 0.23 0.24 0.28 4100 0.25 0.04 0.22 0.25 0.26 0.31 4300 0.28 0.05 0.24 0.28 0.29 0.34 4500 0.30 0.05 0.26 0.30 0.31 0.37 4700 0.33 0.05 0.29 0.33 0.34 0.40 4900 0.36 0.05 0.31 0.35 0.37 0.43 5100 0.39 0.06 0.34 0.38 0.40 0.46 5300 0.42 0.06 0.37 0.41 0.43 0.49 5500 0.45 0.06 0.40 0.44 0.46 0.53 5700 0.48 0.06 0.43 0.47 0.49 0.56 5900 0.52 0.07 0.46 0.50 0.53 0.59 6100 0.56 0.07 0.49 0.53 0.56 0.62 6300 0.60 0.07 0.53 0.56 0.59 0.65 1. Add these resistance values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Additional Static Resistance ZF090 Cabinet (Imperial) CFM Cooling Only1 Economizer2 3 1900 -0.004 0.07 2100 0.01 0.09 2300 0.01 0.11 2500 0.02 0.13 2700 0.03 0.16 2900 0.04 0.18 3100 0.05 0.20 3300 0.06 0.22 3500 0.07 0.24 3700 0.08 0.27 3900 0.09 0.29 4100 0.09 0.31 4300 0.10 0.33 1. Add these resistance values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation. Johnson Controls Unitary Products 37 862075-XTG-F-0513 Additional Static Resistance ZF120/150 Cabinet (Metric) M3S Cooling Only1 Electric Heat kW2 Economizer2 3 18 24 36 54 0.89 14.9 5.0 14.9 17.4 19.9 24.8 0.99 17.4 5.0 17.4 19.9 22.4 27.3 1.08 19.9 5.0 19.9 22.4 24.8 32.3 1.18 22.4 5.0 22.4 24.8 27.3 34.8 1.27 27.3 7.5 24.8 29.8 32.3 39.7 1.36 29.8 7.5 27.3 32.3 34.8 44.7 1.46 34.8 7.5 32.3 37.3 39.7 49.7 1.55 39.7 7.5 34.8 42.2 44.7 54.6 1.65 44.7 9.9 39.7 47.2 49.7 59.6 1.74 49.7 9.9 44.7 52.2 49.7 64.6 1.83 57.1 9.9 49.7 57.1 59.6 69.5 1.93 62.1 9.9 54.6 62.1 64.6 77.0 1.02 69.5 12.4 59.6 69.5 72.0 84.4 2.12 74.5 12.4 64.6 74.5 77.0 91.9 2.21 82.0 12.4 72.0 82.0 84.4 99.3 2.30 89.4 12.4 77.0 86.9 91.9 106.8 2.40 96.9 14.9 84.4 94.4 99.3 114.2 2.49 104.3 14.9 91.9 101.8 106.8 121.7 2.59 111.8 14.9 99.3 109.3 114.2 131.6 2.68 119.2 14.9 106.8 116.7 121.7 139.1 2.77 129.1 17.4 114.2 124.2 131.6 146.5 2.87 139.1 17.4 121.7 131.6 139.1 154.0 2.96 149.0 17.4 131.6 139.1 146.5 161.4 1. Add these resistance values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 62.1 Pa, the unit will deliver less M3S during full economizer operation. Additional Static Resistance ZF090 Cabinet (Metric) M3S Cooling Only1 Economizer2 3 0.9 -0.99 17.40 0.99 2.50 22.40 1.09 2.50 27.40 1.18 4.98 32.40 1.27 7.50 39.90 1.37 10.00 44.83 1.46 12.50 49.81 1.56 14.90 54.80 1.65 17.40 59.80 1.75 19.90 67.20 1.84 22.40 72.20 1.93 22.40 77.20 2.03 24.90 82.20 1. Add these resistance values to the available static resistance in the respective Blower Performance Tables. 2. Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 3. The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 62.1 Pa, the unit will deliver less M3S during full economizer operation. 38 Johnson Controls Unitary Products 862075-XTG-F-0513 Gas Heat Minimum Supply Air Imperial Size (Ton) 090 (7.5) ZF 120 (10) ZF 150 (12.5) Supply Air (CFM) Heat Size Model ZF Cooling Heating Min Max Min Max 10 2250 3750 2250 3750 15 2250 3750 2250 3750 15 3000 5000 3000 5000 20 3000 5000 3000 5000 15 3750 6250 3750 6250 20 3750 6250 3750 6250 Gas Heat Minimum Supply Air Metric Size (KW) 090 (26) ZF 120 (35) ZF 150 (44) Supply Air (M3S) Heat Size Model ZF Cooling Heating Min Max Min Max 10 1.06 1.76 1.06 1.76 15 1.06 1.76 1.06 1.76 15 1.42 2.36 1.42 2.36 20 1.42 2.36 1.42 2.36 15 1.76 2.95 1.76 2.95 20 1.76 2.95 1.76 2.95 Electric Heat Minimum Supply Air Imperial Minimum Supply Air (CFM) Size (Tons) Model 120 (10) ZF 150 (12.5) ZF Voltage Heater kW 18 24 36 54 380/415-3-50 3000 3000 3000 3500 380/415-3-50 3750 3750 3750 3750 Electric Heat Minimum Supply Air Metric Minimum Supply Air (C3S) Size (KW) Model 120 (35) ZF 150 (44) ZF Voltage Heater kW 18 24 36 54 380/415-3-50 1.42 1.42 1.42 1.42 380/415-3-50 1.76 1.76 1.76 1.76 Indoor Blower Specifications Motor Size (Tons) Model 90 (7.5) ZF 120 (10) 150 (12.5) HP RPM 1 Eff. SF Frame 2 2 2 4 1425 1425 1425 1455 0.8 0.8 0.8 0.87 1.15 1.15 1.15 1.15 56 56 56 184T 4 1455 0.87 1.15 184T ZF ZF Motor Sheave Datum Dia. Bore (In.) (In.) 3.4 - 4.4 7/8 3.4 - 4.4 7/8 3.4 - 4.4 7/8 4.0 - 5.0 1-1/8 4.3 - 5.3 1-1/8 Model 1VM50 1VM50 1VM50 1VP56 1VP56 Blower Sheave Datum Dia. Bore (In.) (In.) 5.5 1 5 1 7 1 6.2 1 6.6 1 Model Belt AK59 AK54 AK74 AK66 A49 A47 A54 A55 BK72 BX56 1. 1725 RPM at 60 Hz. Johnson Controls Unitary Products 39 862075-XTG-F-0513 Power Exhaust Specifications Model Voltage 2PE04703246 460-1-60 HP 3/4 Motor RPM1 1075 QTY 1 Motor FLA 2.2 LRA 3.4 CFM @ 0.1 ESP 3800 Fuse Size MCA 2.8 5 1. Motors are multi-tapped and factory wired for high speed, suitable for 50 HZ power supply Sound Performance Indoor Sound Power Levels Size (Tons) 090 (7.5) 120 (10) 150 (12.5) Model CFM ESP (IWG) Blower RPM BHP Rating1 Sound dB (A) 63 Sound Power, dB (10-12) Watts Octave Band Centerline Frequency (Hz) 125 250 500 1000 2000 4000 8000 ZF 3000 0.6 854 1.47 77 74 76 76 74 72 68 68 63 ZF 4000 0.6 959 2.29 83 80 82 82 80 78 74 74 69 ZF 5000 0.6 1132 3.74 87 84 86 86 84 82 78 78 73 1. These values have been accessed using a model of sound propagation from a point source into the hemispheric/free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes an exception to any specification or guarantee requiring a dBA value of sound data in any other form than sound power level ratings. 40 Johnson Controls Unitary Products 862075-XTG-F-0513 Electrical Data ZF090-120 Standard Motor Size (Tons) ZF090 Volt OD Fan Supply Pwr Compressors (each) Motors Blower Exh (each) Motor Motor Electric Heat Option MCA1 (Amps) Max Fuse2/ MCA1 w/ Max Fuse2/ Breaker3 3 Pwr Exh Breaker Size w/ Pwr (Amps) Size (Amps) Exh (Amps) RLA LRA MCC FLA FLA FLA Model KW Stages Amps 380 6.2 52.0 9.7 1.6 4.3 2.2 None - - - 21.5 23.7 25 25 415 6.2 52.0 9.7 1.6 4.3 2.2 None - - - 21.5 23.7 25 25 380 8.0 67.1 12.5 1.6 4.3 2.2 ZF120 415 8.0 67.1 12.5 1.6 4.3 2.2 None - - - 25.5 27.7 30 35 2TP04521850 11.3 2 17.2 26.8 29.6 30 35 2TP04522450 15.0 2 22.8 33.9 36.6 35 40 2TP04523650 21.3 2 32.4 45.8 48.6 50 50 2TP04525450 33.8 2 51.4 69.6 72.3 70 80 None - - - 25.5 27.7 30 35 2TP04521850 13.5 2 18.8 28.9 31.6 30 35 2TP04522450 17.9 2 24.9 36.5 39.3 40 40 2TP04523650 25.4 2 35.3 49.5 52.3 50 60 2TP04525450 40.4 2 56.2 75.6 78.4 80 80 1. Minimum Circuit Ampacity. 2. Maximum Over current Protection per Standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. ZF090-150 Hi Static Motor Size (Tons) ZF090 Compressors (each) Volt OD Fan Supply Pwr Exh Motors Blower Motor (each) Motor Electric Heat Option MCA1 (Amps) Max Max Fuse2/ MCA1 w/ Fuse2/ Breaker3 Size 3 Pwr Exh Breaker w/ Pwr Exh Size (Amps) (Amps) (Amps) RLA LRA MCC FLA FLA FLA Model KW Stages Amps 380 6.2 52.0 9.7 1.6 4.3 2.2 None - - - 21.5 23.7 25 25 415 6.2 52.0 9.7 1.6 4.3 2.2 None - - - 21.5 23.7 25 25 None - - - 27.6 29.8 35 35 2TP04521850 11.3 2 17.2 29.5 32.2 35 35 2TP04522450 15.0 2 22.8 36.5 39.2 40 40 2TP04523650 21.3 2 32.4 48.5 51.2 50 60 2TP04525450 33.8 2 51.4 72.2 74.9 80 80 380 8.0 67.1 12.5 1.6 6.4 2.2 ZF120 415 380 8.0 11.2 67.1 75.0 12.5 17.5 1.6 1.6 6.4 6.4 2.2 2.2 ZF150 415 11.2 75.0 17.5 1.6 6.4 2.2 None - - - 27.6 29.8 35 35 2TP04521850 13.5 2 18.8 31.5 34.2 35 35 2TP04522450 17.9 2 24.9 39.1 41.9 40 45 2TP04523650 25.4 2 35.3 52.2 54.9 60 60 2TP04525450 40.4 2 56.2 78.3 81.0 80 90 None - - - 38.0 40.2 45 50 2TP04521850 11.3 2 17.2 38.0 40.2 45 50 2TP04522450 15.0 2 22.8 38.0 40.2 45 50 2TP04523650 21.3 2 32.4 48.5 51.2 50 60 2TP04525450 33.8 2 51.4 72.2 74.9 80 80 None - - - 38.0 40.2 45 50 2TP04521850 13.5 2 18.8 38.0 40.2 45 50 2TP04522450 17.9 2 24.9 39.1 41.9 45 50 2TP04523650 25.4 2 35.3 52.2 54.9 60 60 2TP04525450 40.4 2 56.2 78.3 81.0 80 90 1. Minimum Circuit Ampacity. 2. Maximum Over current Protection per Standard UL 1995. 3. Fuse or HACR circuit breaker size installed at factory or field installed. Johnson Controls Unitary Products 41 862075-XTG-F-0513 Typical Wiring Diagrams ZF090-150 Typical Wiring Diagrams Typical ZF090-120 Cooling Unit with Gas Heat 380/415 Volt 50 Hz. Wiring Diagram 42 Johnson Controls Unitary Products 862075-XTG-F-0513 Typical ZF090-120 Cooling Unit with/without Electric Heat Wiring Johnson Controls Unitary Products 43 862075-XTG-F-0513 Typical ZF150 Cooling Unit with Gas Heat 380/415 Volt 50 Hz. Wiring Diagram 44 Johnson Controls Unitary Products 862075-XTG-F-0513 Typical ZF150 Cooling Unit with/without Electric Heat Wiring Diagram Johnson Controls Unitary Products 45 862075-XTG-F-0513 Weights and Dimensions ZF090-150 Unit Weights Unit 4 Point Load Weight Unit 6 Point Load Weight FRONT FRONT LEFT LEFT B C B A A D C E F D Y X FRONT LEFT Imperial Size Model (Tons) Weight (lbs.) Shipping Operating Center of Gravity (in.) X Y 4 Point Load Location (lbs.) 6 Point Load Location (lbs.) A B C D A B C D E F 090 (7.5) ZF 885 860 38 24 205 153 223 299 144 117 97 142 171 210 120 (10) ZF 1065 1060 38 24 247 184 268 360 173 141 117 171 206 253 150 (12.5) ZF 1258 1253 47 25 251 280 381 341 164 176 190 259 240 223 Metric Center of Gravity (mm) Shipping Operating X Y Weight (kg.) Size (KW) Model 090 (22) ZF 401 390 965.2 120 (35) ZF 483 480 150 (44) ZF 571 568 46 4 Point Load Location (kg.) 6 Point Load Location (kg.) A B C D A B C D E F 609.7 93 69.4 101.2 135.6 65.3 53.1 44 64.4 77.6 95.3 965.2 609.7 112 83.5 121.6 163.3 78.5 64 53.1 77.6 93.4 114.8 1193.8 635 113.9 127 172.8 154.7 74.4 79.8 86.2 117.5 108.9 101.2 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF090-150 Unit Accessory Weights Imperial Unit Accessory Economizer Power Exhaust Electric Heat1 Gas Heat2 ZF090-150 Unit Accessory Weights Metric Weight (lbs.) Shipping Operating 90 85 40 35 49 49 110 110 Weight (kg.) Shipping Operating 40.8 38.6 18.1 15.9 22.2 22.2 49.9 49.9 Unit Accessory Economizer Power Exhaust Electric Heat1 Gas Heat2 1. Weight given is for the maximum heater size available (54KW). 2. Weight given is for the maximum number of tube heat exchangers available (8 tube). 1. Weight given is for the maximum heater size available (54KW). 2. Weight given is for the maximum number of tube heat exchangers available (8 tube). ZF090-150 Unit Dimensions ZF090 - 120 (754) 29.69 (387) 15.25 15.38 (391) 59.00 (1499) 15.38 (391) 2X Ø 24.38 (619) B NOTE: (XXX) Indicates Millimeters SEE DETAIL A FOR GAS INLET A C D E 11.38 (289) F (1499) 59.00 (106) 4.19 LEFT 27.31 (694) SEE DETAIL B FOR DRAIN LOCATION (2261) 89.00 (538) 21.19 FRONT Johnson Controls Unitary Products 47 862075-XTG-F-0513 ZF150 45.64 (1159) 14.92 (379) 4X Ø 24.38 (619) 14.92 (379) 59.00 (1499) 14.92 (379) 29.95 (761) 30.11 (765) B SEE DETAIL A FOR GAS INLET NOTE: (XXX) Indicates Millimeters A C D E 11.38 (289) F (106) 4.19 59.00 (1499) LEFT SEE DETAIL B FOR DRAIN LOCATION 27.31 (694) 89.00 (2261) 21.19 (538) FRONT ZF090-150 Unit Physical Dimensions Imperial Unit Model Number 090 120 150 A 42 50 3/4 50 3/4 B 89 89 119 1/2 Dimension (in.) C D 22 1/8 18 3/16 30 3/16 24 3/16 30 3/16 24 3/16 E 15 3/16 17 3/16 17 3/16 F 6 3/16 6 3/16 6 3/16 B 2261 2261 3035 Dimension (mm) C D 562 462 767 614 767 614 E 386 437 437 F 157 157 157 ZF090-150 Unit Physical Dimensions Metric Unit Model Number 090 120 150 48 A 1067 1289 1289 Johnson Controls Unitary Products 862075-XTG-F-0513 Detail A 3.184 (81) Gas Pipe Inlet 3.184 Gas Pipe Inlet Ø 2.000 (51) Ø 2.000 Gas Exhaust Vent Gas Exhaust Vent Ø 3.126 (587) Ø 3.126 17.541 14.594 (371) 7.705 (196) 7.715 4.737 4.727 (120) 42”/1067mm CABINET 50 3/4”/1289mm CABINET NOTE: (XXX) Indicates Millimeters Detail B 5-3/8 (137) NOTE: (XXX) Indicates Millimeters 3/4” FPT (19.05) ZF090-150 Unit Clearances Imperial Direction Top1 Front Rear Distance (in.) 72 36 36 Direction Right Left Bottom2 Distance (in.) 12 36 0 1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air discharge outlet. 2. Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. ZF090-150 Unit Clearances Metric Direction Top1 Front Rear Distance (mm) 1829 914 914 Direction Right Left Bottom2 Distance (mm) 305 914 0 1. Units must be installed outdoors. Over hanging structure or shrubs should not obscure condenser air discharge outlet. 2. Units may be installed on combustible floors made from wood or class A, B or C roof covering materials. Johnson Controls Unitary Products 49 862075-XTG-F-0513 ZF090-150 Unit Bottom Duct Opening 89 (2261) 32 11/16 (830) 6 13/16 (173) 6 13/16 (173) SUPPLY AIR RETURN AIR 27 1/2 (690) LEFT 18 (457) 24 (610) RIGHT 21 (533) 20 1/8 19 1/8 (511) (486) 17 1/8 (435) 12 5/16 (313) Bottom condensate drain 14 1/2 (368) 16 3/8 (416) 18 1/16 (459) 25 9/16 (649) Bottom gas supply entry NOTE: (XXX) Indicates Millimeters FRONT TOP VIEW Bottom power, control and convenience outlet wiring entry 3X Ø 0.875 (22) Ø 2.469 (63) 50 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF090-150 Unit Electrical Entry Disconnect Swith Cover Power Entry Ø 2-1/2 (64) Control Entry Ø 7/8 (22) Power Entry Ø 2-1/2 (64) Convenience Outlet Cover Convenience Outlet Power Entry Ø 7/8 (22) FRONT ZF090-120 Unit Side Duct Openings Dot Plugs 18-1/4 (464) Return Air A Supply Air D B 2-31/32 (75) 5-5/32 (131) C NOTE: (XXX) Indicates Millimeters Johnson Controls Unitary Products 31-11/16 (805) 51 862075-XTG-F-0513 ZF150 Unit Side Duct Openings NOTE: (XXX) Indicates Millimeters 18-1/4 (464) Dot Plugs A D B 5-5/32 (131) 31-5/8 (805) C ZF Side Duct Dimensions Imperial Unit Model Number 090 120 150 A 27 3/4 28 1/4 28 1/4 2-7/8 (75) ZF Side Duct Dimensions Metric Dimension (in.) B C 12 1/16 27 1/2 18 1/16 28 1/4 18 1/16 28 1/4 D 16 18 1/4 18 1/4 Unit Model Number 090 120 150 A 705 718 718 Dimension (mm) B C 306 698 459 718 459 718 D 406 464 464 ZF090-150 Unit Left Duct Opening 30-3/8 (772) 4-5/16 (110) 52 Johnson Controls Unitary Products 862075-XTG-F-0513 ZF090-150 Unit Accessory Dimensions ZF090-150 Roof Curb R IG H T 8 0 -5 /8 (2 0 5 0 ) IN S U L A T E D D E C K U N D E R C O N D E N S E R S E C T IO N 2 0 (5 1 0 ) S U P P L Y 6 2 0 (5 1 0 ) (1 5 0 ) 2 T Y P . (5 0 ) R E T U R N 3 0 (7 6 0 ) IN S U L A T E D D E C K U N D E R C O M P R E S S O R S E C T IO N 5 0 -1 /2 (1 2 8 5 ) 8 1 4 O R (2 0 5 ) (3 5 5 ) F R O N T N O T E : (X X X ) IN D IC A T E S D IM E N S IO N S IN M IL L IM E T E R S ZF090-150 Transition Roof Curb 2 T Y P (5 0 ) 5 0 -1 /2 (1 2 8 5 ) 2 3 (5 8 5 ) 3 0 -1 /2 (7 7 5 ) 4 (1 0 0 ) 2 6 (6 6 0 ) R E T U R N 8 0 -5 /8 (2 0 5 0 ) S U P P L Y 1 0 (2 5 5 ) 7 6 -5 /8 (1 9 4 5 ) F R O N T 9 4 (2 3 9 0 ) 5 9 -1 /4 (1 5 0 5 ) 6 4 -1 /4 (1 6 3 0 ) Johnson Controls Unitary Products R IG H T 53 862075-XTG-F-0513 ZF090-150 Economizer Assembly 58 1/4 (148) 88 1/4 (224.2) 39 1/2 (100) or 47 1/2 (120.7) Outside Air Intake Hood 35 3/4 (90.8) Relief Hood for Power Exhaust or Barometric Relief 26 (66) 54 25 3/4 (65.4) 26 (66) 30 1/4 (76.8) Johnson Controls Unitary Products 862075-XTG-F-0513 Economizer Options Economizer Usage Application Cabinet Height Description Model Bottom Return All Downflow economizer with barometric relief 2EE04705924 Side Return All Horizontal economizer without barometric relief 2EE047060241 42"/1067mm Slab Economizer, 42”/1067mm tall cabinet 2EE047058242 50"/1289mm Slab Economizer, 50”/1289mm tall cabinet 2EE047057242 ERV or End Return 1. Barometric relief must be ordered separately and installed in duct work. 2. Barometric relief or fresh air hood not included. Must be ordered separately. Factory Installed Downflow Economizer Fresh Air Hood Fresh Air Damper Return Air Damper Barometric Relief Damper Barometric Relief Hood Field Installed Downflow Economizer W/Power Exhaust Fresh Air Hood Fresh Air Damper Return Air Damper Power Exhaust Barometric Relief Damper Johnson Controls Unitary Products Barometric Relief Hood 55 862075-XTG-F-0513 Field Installed Horizontal Economizer W/Power Exhaust Return Air Damper Field Installed Duct Work Fresh Air Damper Power Exhaust Barometric Relief Damper Barometric Relief Hood Fresh Air Hood Slab Economizer Downflow W/Power Exhaust Fresh Air Hood Slab Economizer Power Exhaust Barometric Relief Damper 56 Barometric Relief Hood Johnson Controls Unitary Products 862075-XTG-F-0513 Slab Economizer End Return W/Power Exhaust Fresh Air Hood Field Installed Duct Work Slab Economizer Barometric Relief Hood Power Exhaust Barometric Relief Damper Johnson Controls Unitary Products 57 Subject to change without notice. Printed in U.S.A. Copyright © 2014 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, OK 73069 862075-XTG-F-0513 Supersedes: 862075-XTG-E-1012
© Copyright 2024 ExpyDoc