INSTRUCTION SHEET ERICO DYNASPHERE MKIV ® Installation Instructions for 5m Stainless Steel Cantilevered Mast - SIM Series Terminal Elevation: 4m Above Structure Mast Detail (ERICO Part # TCEC253) Copper Tape ERICO DYNASPHERE (ERICO® Part # D/SMKIV-SS) (ERICO Part # PDCUC) Tape Fasteners SIM28A2 INTCPT ADAPTER (ERICO Part # INTCPTMIDYN) Stainless Steel Mast (ERICO Part # SIM28A2) SIM33B3 Typical Conductor Connection Not to Scale 3 - Bonding Clamp (ERICO Part # TMCSS) 1 - 39.9mm 2 Holes, Stainless Steel Cable Tie (ERICO Part # CABTIESS) Three every 1m TMCSS Mast Clamp Installing contractor to field adjust and insure a secure bond on highest SIM series mast 10.9mm 89.9mm 119.9mm Downconductor End View 1m Stainless Steel Mast (ERICO Part # SIM33B3) 2 - 1 - Not to Scale 2 - Typical ALOF1GS Wall Bracket Base Not to Scale Mast Support Bracket (ERICO Part # ALOF1GS) Detail "A" Two downconductors are required 3 - Lightning Event Counter (ERICO Part # LECIV) Downconductor Lightning Event Counter Refer to installation manual for alternate locations (ERICO Part # LECIV) ERICO® CADWELD® Connection or mechanical connection Ground Inspection Well For complete grounding system refer to Detail "A" Crow's Foot (ERICO Part # GF302) 3m tape enclosed in GEM material Minimum 16mm X 2.4m long ground rod in four locations Suggested triangular grounding system for each downconductor: The grounding system shown in the detail is a suggested layout. Each radial consists of a trench approximately 0.8m deep. The conductor is laid in the trench and is connected to ground rods. The conductor in each trench is encased in GEM material. Ground rods must extend 3m below ground level. Note: This is one of several alternative installation methods. Refer to ERICO installation manual for more details. WARNING: 1. ERICO products shall be installed and used only as indicated in ERICO product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. 2. ERICO products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings. 3. All instructions must be completely followed to ensure proper and safe installation and performance. 4. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. TECHNICAL SUPPORT www.erico.com IP79153_A 1 OF 1 © 2014 ERICO International Corporation.
© Copyright 2024 ExpyDoc