-------------------------------------------------------- 8015648.YYC1 0616 COMAT ------------------------------------------------------- WL24-2X Ident-No.: 9131755 YYC1 Declaration New Zealand Phone +64 9 415 0459 Norway Phone +47 67 81 50 00 Poland Phone +48 22 539 41 00 Romania Phone +40 356 171 120 Russia Phone +7 495 775 05 30 Singapore Phone +65 6744 3732 Slovakia Phone +421 482 901201 Slovenia Phone +386 591 788 49 South Africa Phone +27 11 472 3733 South Korea Phone +82 2 786 6321 Spain Phone +34 93 480 31 00 Sweden Phone +46 10 110 10 00 Switzerland Phone +41 41 619 29 39 Taiwan Phone +886 2 2375-6288 Thailand Phone +66 2645 0009 Turkey Phone +90 216 528 50 00 United Arab Emirates Phone +971 4 88 65 878 United Kingdom Phone +44 1727 831121 USA Phone +1 800 325 7425 Vietnam Phone +84 945452999 SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch Please find detailed addresses and further locations in all major industrial nations at www.sick.com In Compliance with the Directive ATEX 2014/34/EU We hereby declare that the devices (see page 5) of the product family WL/WLL24-2X comply with the basic requirements of the EU Directive specified under Page 2. If an item of equipment listed overleaf is modified without our approval then this declaration loses its validity for this equipment. Following inspection result have been achieved for the listed devices: ΙΙ 2G Ex ia op is ΙΙC T4 Gb -20°C < Ta < +60°C Ui ≤ 15,5V; Ii ≤ 53mA; Pi ≤ 100mW, Li ≈ 0µH, Ci ≤ 80nF BZ int46 Australia Phone +61 3 9457 0600 Austria Phone +43 22 36 62 28 8-0 Belgium/Luxembourg Phone +32 2 466 55 66 Brazil Phone +55 11 3215-4900 Canada Phone +1 905 771 14 44 Czech Republic Phone +420 2 57 91 18 50 Chile Phone +56 2 2274 7430 China Phone +86 20 2882 3600 Denmark Phone +45 45 82 64 00 Finland Phone +358-9-2515 800 France Phone +33 1 64 62 35 00 Germany Phone +49 211 5301-301 Hong Kong Phone +852 2153 6300 Hungary Phone +36 1 371 2680 India Phone +91 22 4033 8333 Israel Phone +972 4 6881000 Italy Phone +39 02 274341 Japan Phone +81 3 5309 2112 Malaysia Phone +6 03 8080 7425 Mexico Phone +52 472 748 9451 Netherlands Phone +31 30 2044 000 More representatives and agencies at www.sick.com ∙ Subject to change without notice ∙ The specified product features and technical data do not represent any guarantee. Weitere Niederlassungen finden Sie unter www.sick.com ∙ Irrtümer und Ä nderungen vorbehalten ∙ Angegebene Produkteigenschaften und technische Daten stellen keine Garantieerklärung dar. Plus de représentations et d’agences à l’adresse www.sick.com ∙ Sujet à modification sans préavis ∙ Les caractéristiques de produit et techniques indiquées ne constituent pas de déclaration de garantie. Para mais representantes e agências, consulte www.sick.com ∙ Alterações poderão ser feitas sem prévio aviso ∙ As características do produto e os dados técnicos apresentados não constituem declaração de garantia. Altri rappresentanti ed agenzie si trovano su www.sick.com ∙ Contenuti soggetti a modifiche senza preavviso ∙ Le caratteristiche del prodotto e i dati tecnici non rappresentano una dichiarazione di garanzia. Más representantes y agencias en www.sick.com ∙ Sujeto a cambio sin previo aviso ∙ Las características y los datos técnicos especificados no constituyen ninguna declaración de garantía. 欲了解更多代表机构和代理商信息,请登录 www.sick.com ∙ 如有更改 , 不另行通知 ∙ 对所给出的产品特性和技术参数 的正确性不予保证。 その他の営業所は www.sick.com よりご覧ください ∙ 予告なし に変更されることがあります ∙ 記載されている製品機能およ び技術データは保証を明示するものではありません。 Note for the inspection result: None. The notified body: Physikalisch-Technische Bundesanstalt (PTB), ID-number 0102, has issued the EUtype-examination PTB 08 ATEX 2029 for above mentioned product family. The approval of the QM-system was granted by notified body: TÜV Nord CERT GmbH, ID-number 0044, certificate TÜV 02 ATEX 1845 Q This declaration certifies compliance with the indicated directives but implies no warranty of properties. Safety instructions included in product documentation have to be observed. used directives and standards List of devices (count: 6) Pos Pos.text Short.desc. Document-No. Issued SICK-Id-No. Pos-Exchg. SICK-ID-No. Device-type 0110 0150 1230 1240 2080 4030 4040 4060 4080 OJEU L 96 EMC-DIRECTIVE 2014/30/EU OJEU L 96 ATEX-DIRECTIVE 2014/34/EU EXPL.ATMOSPH LVD,EMC LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR LVD,EMC LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR EMC LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ATEX EXPLOSIVE ATMOSPHERES, GAS, DUST ATEX EXPLOSIVE ATMOSPHERES, GAS, DUST ATEX ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATEX ELECTRICAL APPARATUS FOR EXPLOSIVE GAS RL RL EN EN EN EN EN EN EN 2014-02-26 2014-02-26 2007-12-01 2012-11-01 2000-01-01 2012-08-01 2013-11-01 2012-01-01 2007-03-01 8606191 8606193 8605900 8606124 8605532 8606139 8606140 8606084 8605902 1026036 1026037 1026038 1026039 1056513 1056514 as of 2016-06-27 2014/30/EU 2014/34/EU 60947-5-2 60947-5-2/A1 60947-5-6 60079-0 60079-0/A11 60079-11 60079-28 EU declaration of conformity 9131559 WL24-2X230 WL24-2X430 WLL24-2X230 WLL24-2X430 WL24-2X430S07 WLL24-2X430S01 as of 2016-06-27 EU declaration of conformity 9131559 -------------------------------------------------------- 8015648.YYC1 0616 COMAT ------------------------------------------------------- WT24-2X Declaration New Zealand Phone +64 9 415 0459 Norway Phone +47 67 81 50 00 Poland Phone +48 22 539 41 00 Romania Phone +40 356 171 120 Russia Phone +7 495 775 05 30 Singapore Phone +65 6744 3732 Slovakia Phone +421 482 901201 Slovenia Phone +386 591 788 49 South Africa Phone +27 11 472 3733 South Korea Phone +82 2 786 6321 Spain Phone +34 93 480 31 00 Sweden Phone +46 10 110 10 00 Switzerland Phone +41 41 619 29 39 Taiwan Phone +886 2 2375-6288 Thailand Phone +66 2645 0009 Turkey Phone +90 216 528 50 00 United Arab Emirates Phone +971 4 88 65 878 United Kingdom Phone +44 1727 831121 USA Phone +1 800 325 7425 Vietnam Phone +84 945452999 SICK AG, Erwin-Sick-Strasse 1, D-79183 Waldkirch Please find detailed addresses and further locations in all major industrial nations at www.sick.com In Compliance with the Directive ATEX 2014/34/EU We hereby declare that the devices (see page 5) of the product family WT24-2X comply with the basic requirements of the EU Directive specified under Page 2. If an item of equipment listed overleaf is modified without our approval then this declaration loses its validity for this equipment. Following inspection result have been achieved for the listed devices: ΙΙ 2G Ex ia op is ΙΙC T4 Gb -20°C < Ta < +60°C Ui ≤ 15,5V; Ii ≤ 53mA; Pi ≤ 100mW, Li ≈ 0µH, Ci ≤ 80nF BZ int46 Australia Phone +61 3 9457 0600 Austria Phone +43 22 36 62 28 8-0 Belgium/Luxembourg Phone +32 2 466 55 66 Brazil Phone +55 11 3215-4900 Canada Phone +1 905 771 14 44 Czech Republic Phone +420 2 57 91 18 50 Chile Phone +56 2 2274 7430 China Phone +86 20 2882 3600 Denmark Phone +45 45 82 64 00 Finland Phone +358-9-2515 800 France Phone +33 1 64 62 35 00 Germany Phone +49 211 5301-301 Hong Kong Phone +852 2153 6300 Hungary Phone +36 1 371 2680 India Phone +91 22 4033 8333 Israel Phone +972 4 6881000 Italy Phone +39 02 274341 Japan Phone +81 3 5309 2112 Malaysia Phone +6 03 8080 7425 Mexico Phone +52 472 748 9451 Netherlands Phone +31 30 2044 000 Ident-No.: 9117092 YYC1 More representatives and agencies at www.sick.com ∙ Subject to change without notice ∙ The specified product features and technical data do not represent any guarantee. Weitere Niederlassungen finden Sie unter www.sick.com ∙ Irrtümer und Ä nderungen vorbehalten ∙ Angegebene Produkteigenschaften und technische Daten stellen keine Garantieerklärung dar. Plus de représentations et d’agences à l’adresse www.sick.com ∙ Sujet à modification sans préavis ∙ Les caractéristiques de produit et techniques indiquées ne constituent pas de déclaration de garantie. Para mais representantes e agências, consulte www.sick.com ∙ Alterações poderão ser feitas sem prévio aviso ∙ As características do produto e os dados técnicos apresentados não constituem declaração de garantia. Altri rappresentanti ed agenzie si trovano su www.sick.com ∙ Contenuti soggetti a modifiche senza preavviso ∙ Le caratteristiche del prodotto e i dati tecnici non rappresentano una dichiarazione di garanzia. Más representantes y agencias en www.sick.com ∙ Sujeto a cambio sin previo aviso ∙ Las características y los datos técnicos especificados no constituyen ninguna declaración de garantía. 欲了解更多代表机构和代理商信息,请登录 www.sick.com ∙ 如有更改 , 不另行通知 ∙ 对所给出的产品特性和技术参数 的正确性不予保证。 その他の営業所は www.sick.com よりご覧ください ∙ 予告なし に変更されることがあります ∙ 記載されている製品機能およ び技術データは保証を明示するものではありません。 Note for the inspection result: None. The notified body: Physikalisch-Technische Bundesanstalt (PTB), ID-number 0102, has issued the EUtype-examination PTB 08 ATEX 2029 for above mentioned product family. The approval of the QM-system was granted by notified body: TÜV Nord CERT GmbH, ID-number 0044, certificate TÜV 02 ATEX 1845 Q This declaration certifies compliance with the indicated directives but implies no warranty of properties. Safety instructions included in product documentation have to be observed. used directives and standards List of devices (count: 3) Pos Pos.text Short.desc. Document-No. Issued SICK-Id-No. Pos-Exchg. SICK-ID-No. Device-type 0110 0150 1230 1240 2080 4030 4040 4060 4080 OJEU L 96 EMC-DIRECTIVE 2014/30/EU OJEU L 96 ATEX-DIRECTIVE 2014/34/EU EXPL.ATMOSPH LVD,EMC LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR LVD,EMC LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR EMC LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ATEX EXPLOSIVE ATMOSPHERES, GAS, DUST ATEX EXPLOSIVE ATMOSPHERES, GAS, DUST ATEX ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATEX ELECTRICAL APPARATUS FOR EXPLOSIVE GAS RL RL EN EN EN EN EN EN EN 2014-02-26 2014-02-26 2007-12-01 2012-11-01 2000-01-01 2012-08-01 2013-11-01 2012-01-01 2007-03-01 8606191 8606193 8605900 8606124 8605532 8606139 8606140 8606084 8605902 1040722 1041910 1056512 as of 2016-06-27 2014/30/EU 2014/34/EU 60947-5-2 60947-5-2/A1 60947-5-6 60079-0 60079-0/A11 60079-11 60079-28 EU declaration of conformity 9084571 WT24-2X400 WT24-2X200 WT24-2X400S26 as of 2016-06-27 EU declaration of conformity 9084571
© Copyright 2024 ExpyDoc