Sep. 7, 2012 Runoff Analysis using CommonMP Yoshito KIKUMORI, River Dept. NILIM NILIM Ministry of Land, Infrastructure, Transport and Tourism National Institute for Land and Infrastructure 1 NILIM 1. 2. 3. 4. 5. What is CommonMP? What can we do with CommonMP? Configuration of CommonMP Building Simple Simulation Project River Channel Discharge at Flood Time (Practice) Parameter Sensibility Analysis of Storage Function Runoff Model (Practice) 2 NILIM 1. What is CommonMP? What can we do with CommonMP? ・ CommonMP is the Common Platform on which various hydraulic and hydrology models run simultaneously in cooperate with each other. ・ Element Models is various hydraulic and hydrology models which run on CommonMP. Element Model Runoff CommonMP Element Model 流出 計算 ○○ 計算 inundation River 氾濫 計算 •We can make simulation of hole river basin utilizing CommonMP 3 NILIM 1. What is CommonMP? What can we do with CommonMP? •Simulation Project and Element Models have high portablity. From A to B Element Model 降雨 予測 Element Model B Building Simulation Project CommonMP ○○ 計算 河道 計算 A Building Element Model From B to A Simulation Project 4 NILIM 1. What is CommonMP? What can we do with CommonMP? •Frequently used Element models are already built by NILIM 5 NILIM 1. What is CommonMP? What can we do with CommonMP? ■オフライン入力モジュール群 1.降雨観測値・予測値 の入力モジュール ・地上観測雨量 ・レーダ雨量 ■オンライン入出力モジュール群 2.水位観測値等の入力 モジュール 12.統一河川情報システムの 入出力 ・観測水位 ・河口潮位 ・ダムや排水機場などの 施設の流入・放流量 ・地上観測雨量 ・レーダ雨量 ・観測水位 ・河口潮位 ・ダムや排水機場などの施設 の流入・放流量 ※wisef形式のcsvデータを読み込む •Using element models building by NILIM etc. you can conduct hydraulic and hydrology. ■演算モジュール群 3.降水量モジュール 5.河川管理施設の 操作モジュール 8.調整のモジュール ・面積雨量 ・ダム ・放水路 ・ニューラルネットワーク ・分布型雨量 ・排水機場 ・堰 ・定数固定現時刻合わせ方式 ・遊水地 ・樋門樋管 ・累加雨量、欠測処理 ・降雨量手動入力 ・水閘門(大規模) ・内水域 ・放流量手動入力 4.流出モデルのモジュール (集中型モデル) 13.水位相関による 予測モジュール (分布型モデル) ・貯留関数 ・有効降雨モデル ・タンクモデル ・表面流 ・合理式 ・表層 ・準線型貯留 関数 ・中間層上段 6.河道モデルのモジュール ・単相関 ・重相関 ・等流 ・不等流 ・S-Q関係 ・中間層下段 ・地下層 7.水位ー流量関係 モジュール ・実績HーQ ・H-Q式算定 ■出力モジュール群 9.グラフ表示のモジュール ・流出予測結果のグラフ表示 ・基準水位との対比 ・洪水規模の評価 11.データ保存のモジュール ・降雨値 ・潮位・流入量・放流量 ・調節のモジュールの算出結果 10.リスク表示のモジュール 下記に対し、アラートを行う ・雨量、水位 ・調整のモジュールの出力 ・誤差評価 14.誤差評価のモジュール ・洪水予測モデルチェックマニュ アルの誤差評価 凡例 入力要素 演算要素 出力要素 1つの要素モデル データ伝送 CommonMP仕様 6 NILIM 2. Configuration of CommonMP 7 国土技術政策総合研究所 2. Directories and Files for CommonMP ●CommonMP\Execute\bin for Executable files ●CommonMP\Execute\conf for Configuration flies ●CommonMP\CommonMPData for Simulation Projecto Files ●CommonMP\Source\HYMCO\OptionImpl Source of Element Model 8 NILIM 3. Building Simple Project (Practice) 9 NILIM 3. Building Simple Project (Practice) Boot of CommonMP Double Click Icon of CommonMP Double Click 10 NILIM 3. Building Simple Project (Practice) Bulid New Project Choose Menu [File →Project → New] 11 NILIM 3. Building Simple Project (Practice) Input of Projct Info Project Group and Project Name are necessary. Project Gr: AAA_Basin Project Name:Sample 12 NILIM 3. Building Simple Project (Practice) Data Copy Rain.csv in Input Dir of Project Dir. 13 NILIM 3. Building Simple Project (Practice) Placement of Element Model Partical Gr Basin Convergence Gr User Difinition Channel Input Marge 接続要素 Output NILIM 3. Building Simple Project (Practice) Sample Project Storage Function CSV Input Monitor Output 河道貯留関数 (S-Q関係) 15 NILIM 3. Building Simple Project (Practice) Placement of Element Model Choose Input Element , and the place it. 16 NILIM 3. Building Simple Project (Practice) Placement of Element Model Input the time series CSV 17 NILIM 3. Building Simple Project (Practice) Setting Parameters Double click Input Element and click advanced setting for pramenter setting. 入力要素モデルを ダブルクリックします クリックします 18 NILIM 3. Building Simple Project (Practice) Setting Parameter Data File(Rain.csv) 観測所地点数(5)を入力 地点指定(1)を入力 Click “Configuration” ※:..\..\CommonMPData\AAAグループ\InputData\Rain.csv 19 国土技術政策総合研究所 3. Building Simple Project (Practice) Placement of Element Basin Element 20 NILIM 3. Building Simple Project (Practice) Placement of Element Sample Storage Function 21 NILIM 3. Building Simple Project (Practice) Setting Parameter Double Click Time Step:360sec Basin Area:50km2 Parameter K:43.1 Parameter P:0.31 Delay Time:0.3hr F1:0.5 Rsa:80mm Base Flow:4.8m3/sec Input parameters 22 NILIM 3. Building Simple Project (Practice) Placement of Element Stream Element 23 国土技術政策総合研究所 3. Building Simple Project (Practice) Placement of Element (S-Q関係) (S-Q関係) 24 NILIM 3. Building Simple Project (Practice) Setting Parameter 各パラメータに任意の値を 入力します ダブルクリックします K: 11.8 P: 0.6 Tl: 0.3hr Tlz:0.3hr 25 NILIM 3. Building Simple Project (Practice) Placement of Element Output Element 26 国土技術政策総合研究所 3. Building Simple Project (Practice) Placement of Element 27 NLIM 3. Building Simple Project (Practice) Conneting Element 28 国土技術政策総合研究所 3. Building Simple Project (Practice) Conneting Element 接続要素を選択した状態で、 「1次元配列時系列情報」を 選択し、ダブルクリックします 29 NILIM 3. Building Simple Project (Practice) Conneting Element 30 NILIM 3. Building Simple Project (Practice) Connecting Element 31 NILIM 3. Building Simple Project (Practice) Connecting Element 32 NILIM 3. Building Simple Project (Practice) Connecting Element 33 NILIM 3. Building Simple Project (Practice) Monitor Output 34 NILIM 3. Building Simple Project (Practice) Model Check Click Model check Errot 35 NILIM 3. Building Simple Project (Practice) Setting Simulation Period ※2007/7/7 10:00~2007/7/10 23:00 36 NILIM 3. Building Simple Project (Practice) Execution of Project 37 NILIM 3. Building Simple Project (Practice) Save Project 38
© Copyright 2024 ExpyDoc