DIGICONTROL- Gerätedatenblatt R-RAK www.gfr.de [ 82130 ] Category: Field Units - Monitor Universal thermostat DIGICONTROL R-RAK Application For controlling and monitoring the temperature of liquids in baths, containers, pipes and ducts. Because of its modular design and universal housing, the thermostat is very versatile. It can be used as: a stem-type thermostat with protective tube (pocket); a clamp-on thermostat on pipes; a thermostat with a remote sensor; or a double thermostat. Universal housing made of plastic; can be fitted in various ways; snap-on lid with window, sealable; internal setpoint adjuster; thermostat module with single-pole change-over contacts (TB has normally-closed contacts); capillary tube (which can be uncoiled according to needs, depending on the fitting method) and sensor cartridge; screw terminals for wire of max. 1,5 2 mm ; cable screw fitting for cable of up to Ø 9 mm. Setting range Switching difference K Artikeltyp °C Capillary tube mm Sensor cartridge mm Max. temp. of sensor °C As a temperature controller-monitor (TR, TM); with LW 7 pocket, brass, 100 mm; as per DIN 3440 RAK 82.4/3773M 5...30 4 800 68 200 RAK 82.4/3770M –10...50 4 1600 68 180 RAK 82.4/3728M 15...95 4 800 68 200 RAK 82.4/3754M 40...120 4 1600 68 200 RAK 82.4/3726M 50...130 4 800 68 200 3) 80...160 4 1600 68 200 RAK 82.4/3753M 3) 150...230 4 1000 68 280 RAK 82.4/3729M As a safety temperature limiter (STB), classified in PED 97/23/EC as per Cat. IV; with LW 7 pocket, brass, 100 mm; as per DIN 3440; intrinsically safe; with mechanical lock. RAK 13.4040S 120/110/100/95 1) 20 800 68 200 130/120/110/100/95 RAK 13.4050S 1) 20 800 68 220 Technical Data Max. contact rating 2) Degree of protection IP 40 (EN 60529) I (IEC 60730) Terminal 1-2 TW, TB 10 (2.6) A 250 V~ Protection class Terminal 11-12 STB 10 (6) A 250 V~ DIN register number Terminal 1-4 TW 4 (0.6) A 250 V~ Thermostat module TR 706 01 500 mA 40 V Thermostat module STB 1060 2000 Not classified in the PED RAK 84.4 and 82.4 Min. contact rating Time constant in water without pocket < 15 s with LW 7 pocket Calibrated at < 45 s TW, TB 23 ± 2 °C (Tu 23) STB 37 ± 2 °C (Tu 37) Influence of head temperature Copyright © GFR mbH 2008 / Änderungen vorbehalten Classified in the PED 97/23/EG as per Cat. IV: Test marking 4) Wiring diagram RAK 13.40 ID: 0000006982 TW A10391 Seite 1 von 4 DIGICONTROL- Gerätedatenblatt depends on type R-RAK Weight 0,20 – 0,60 K/K Transport and storage temperature • Permissible ambient temp. (head) • as clamp-on sensor (water temp.) www.gfr.de STB A10396 TB A10394 0,22 kg –25...55 °C Dimension drawing M05633 0...50 °C (T50) Fitting instructions MV 505803 Wiring Diagramm Controller, monitor, limiter TR, TW Safety temperature limiter STB 1 2 4 1 2 11 12 14 E L1 N PE Temperature limiter TB E E L1 N PE L1 N PE A10391 A10396 A10394 l 110 L 41 Dimension drawing Ø6,5 25 68 Pg11 20,8 66,8 Ergänzungsdaten 1 .. n (= Texte, Bilder weiterer M05633a Produkteigenschaften) Operation The single-pole change-over contacts (or the normally-closed contacts on the TB) function according to temperature. The adjustable setpoint Xs equals the upper switching point. The switching difference Xsd is fixed. By dovetailing their housings together, two units can be linked to each other side by side, thereby easily allowing a double thermostat (controller-monitor or monitor-limiter) to be employed. On reaching the setpoint, the contacts change over and lock mechanically. Not until the temperature has fallen can the thermostat be reset by pressing the internal ‘Reset’ knob. Copyright © GFR mbH 2008 / Änderungen vorbehalten Seite 2 von 4 DIGICONTROL- Gerätedatenblatt Additional technical details Setting accuracy as a limiter as a clamp-on sensor Serviceable life when used as a limiter Degree of radio interference Material:Housing base Housing lid Window ± 6 K at 50 °C +0/–9 K at 50 °C +4 K (systematic error) > 100 000 switchings > 15 000 switchings click rate < 5 (EN 55014) R-RAK www.gfr.de Sensor medium:up to 160 °C up to 230 °C Setting accuracy as a limiter as a clamp-on sensor Serviceable life On the basis of the information currently available, no risks to health or to the environment (as per 67/548/EEC) can be expected if used in accordance with regulations. PA reinforced to 120 °C ABS, resistant to 80 °C PC, resistant to 80 °C Conforms to low-voltage directive 73/23/EC (EN 60730-1;2-9) Conforms to EMC directive 89/336/EC as per EN 55014: 4.2 RAK 82.4 + 84.4 should not be used to guarantee the safety of installations which are subject to regulation 97/23/EEC concerning pressure equipment. Influence of temperature of instrument head Type Calibration Correction factor RAK . . . .M tolerance *) K K/K 3773 ±6 0,14 3770 ±6 0,29 3728 ±6 0,18 3754 ±6 0,31 3726 ±7 0,19 3729 ±7 0,34 3753 ±8 0,25 4040, 4050 +0 /-9 0,31 3782 ±6 0,32 3783 ±7 0,38 *) with respect to the ambient temperature Technical notes RC circuit under inductive load For the optimum RC circuit, see specifications supplied by the manufacturer of the contactors, relays etc. If, however, these are not available, the following rule of thumb (not binding) can be used to reduce the inductive load:• Capacitance of the RC circuit (µF) ≥ operating current (A) • Resistance of the RC circuit (Ω) ≈ coil resistance (Ω) B03772 Accessories Artikelnummer Beschreibung 0364433 001* Indicator lamp: 250 V~ for showing the switching status on the monitor 0364435 001 Assembly kit for clamp-on and double thermostat with 2 plugs for maintaining degree of protection IP 40, plus retaining strap for fitting to pipes of ½ “…3“ (for RAK as a clamp-on thermostat: T < 120 °C) As stem-type thermostat: (see chapter 29 for further details on pockets) 0364439 . . . LW 7 pockets; of brass; R½; for one sensor cartridge 0364244 . . . LW 15 pockets; of brass; R½, for 2-3 sensor cartridges As thermostat with remote sensor: 0296724 000* Sensor holder for wall mounting 0303212 000* Rubber grommet for capillary-tube guide in air ducts; T < 50 °C 0364140 000* Tension-relief piece for fitting in protective tubes. 0364432 001* Fixing bracket for wall or duct mounting 0364434 001* Supporting coil for sensor, for direct fitting in air ducts 0036787 000* Grommet for capillary tube, with packing box; R½, brass, 12 bar, 180 °C Copyright © GFR mbH 2008 / Änderungen vorbehalten Seite 3 von 4 DIGICONTROL- Gerätedatenblatt R-RAK www.gfr.de 1) Settings (via catches) are irreversible 2) If under inductive load, take RC circuit into account. 3) No pocket included; stainless-steel pockets should be used above 130 °C; see chapter 29 4) Certificates can be downloaded from www.tuv.com 1 2 E GFR - Gesellschaft für Regelungstechnik und Energieeinsparung mbH Kapellenweg 42 D-33415 Verl phone: +49 (0) 5246 962-0 www.gfr.de / [email protected] Löbstedter Str. 101 D-07749 Jena phone: +49 (0) 3641 4697-0 [email protected] 07.2008 / Rev1 Copyright © GFR mbH 2008 / Änderungen vorbehalten Seite 4 von 4
© Copyright 2024 ExpyDoc