14/01/2016 21:48 ICT 2016 - 6th Conference on Industrial Computed Tomography in Wels / Austria 9/Feb/2016 – 12/Feb/2016 Submission categories: “Keynote” Talk (25 + 5 min) “Talk” Paper + Talk (15+5 min) “Short talk” Paper + Poster + Talk (5 min) “Poster exhibition” Paper + Poster / Poster There are no parallel sessions. Presenting authors are underlined. 14/01/2016 21:48 Date: Tuesday, 09/Feb/2016 1:00pm - 6:00pm Talks (15+5 min) by sponsors: FEI, Excillum, GE, Northstar Imaging, Volume Graphics, Rayscan, Werth, Simpleware, Siemens, Hachtel, Deben, … Building A, Auditorium Date: Wednesday, 10/Feb/2016 9:00am - 9:10am Welcome and introduction Building A, Auditorium 9:10am - 9:40am Keynote (I): R. Stössel - Computed Tomography at Airbus Group Building A, Auditorium 9:40am - 11:00am MAT1: Materials characterisation (I) Building A, Auditorium 11:00am - 11:30am Break Building A, Exhibition area 11:30am - 12:50pm MAT2: Materials characterisation (II) Building A, Auditorium 12:50pm - 1:50pm Lunch Building A, Auditorium 1:50pm - 3:50pm NDT1: Manufacturing, NDT and instrumentation (I) Building A, Auditorium 3:50pm - 4:20pm Break Building A, Exhibition area 4:20pm - 5:20pm NDT2: Manufacturing, NDT and instrumentation (II) Building A, Auditorium 5:20pm - 6:40pm SHT: Short talks (5 mins) Building A, Auditorium 6:40pm - 8:30pm POSTER: poster exhibition 14/01/2016 21:48 Building A, Exhibition area Date: Thursday, 11/Feb/2016 9:00am - 9:30am Keynote (II): M. McCarthy - X-ray CT for metrology Building A, Auditorium 9:30am - 10:30am MET1: Metrology (I) Building A, Auditorium 10:30am - 11:00am Break Building A, Exhibition area 11:00am - 12:40pm MET2: Metrology (II) Building A, Auditorium 12:40pm - 1:40pm Lunch Building A, Auditorium 1:40pm - 2:40pm MET3: Metrology (III) Building A, Auditorium 2:40pm - 3:40pm REC1: Reconstruction (I) Building A, Auditorium 3:40pm - 4:10pm Break Building A, Exhibition area 4:10pm - 5:30pm ALG: Algorithms, optimisations and visualisations Building A, Auditorium 5:30pm - 6:00pm Break Building A, Exhibition area 6:00pm - 11:00pm Bus Transfer & Conference dinner Conference dinner Date: Friday, 12/Feb/2016 9:00am - 9:30am Keynote (III): J. Herzen - Grating Interferometer 14/01/2016 21:48 Building A, Auditorium 9:30am - 10:10am GIM: Grating Interferometer Building A, Auditorium 10:10am - 10:40am Break Building A, Exhibition area 10:40am - 11:40am MUL: Multi-modal and multi-energy Building A, Auditorium 11:40am - 12:10pm Break Building A, Exhibition area 12:10pm - 12:50pm REC2: Reconstruction and corrections methods (II) Building A, Auditorium Presentations MAT1: Materials characterisation (I) Time: Wednesday, 10/Feb/2016: 9:40am - 11:00am · Location: Building A, Auditorium 3D microstructure and damage accumulation in a cast AlSi12Cu5Ni2-Mg piston alloy as a function of solution treatment Katrin Bugelnig1, Guillermo Requena2, Frederico Sket3, Fabian Wilde4 TU Wien, Austria; DLR, Germany; 3IMDEA Materials Institute, Spain; 4Helmholtz-Zentrum Geesthacht, Germany; [email protected] 1 2 SEM-calibrated micro-CT image for coal permeability computation Hamed Lamei Ramandi, Peyman Peyman Mostaghimi, Ryan T. Armstrong, W. Val Pinczewski The University of New South Wales, Australia; [email protected] Quantitative local strain mapping on SLM Ti scaffolds by non-rigid registration of X-ray CT images Nicholas Lippiatt, Martine Wevers KUL, Belgium; [email protected] Size and shape determination of sub-millimeter sized particles with X-ray computed tomography Christian Rothleitner, Ulrich Neuschaefer-Rube Physikalisch-Technische Bundesanstalt (PTB), Germany; [email protected] 14/01/2016 21:48 MAT2: Materials characterisation (II) Time: Wednesday, 10/Feb/2016: 11:30am - 12:50pm · Location: Building A, Auditorium Effect of granite internal structure on its mechanical behavior Denis Jelagin1, Iwan Jerjen2, Mahdi Saadati1,3, Per-Lennart Larsson1 KTH, Sweden; 2ETHZ, Switzerland; 3Atlas Copco, Sweden; [email protected] 1 Comparison of predicted and measured fiber orientations in injection molded parts Günter Gsellmann1, Michael Jerabek1, Dietmar Salaberger2 Borealis Polyolefine GmbH, Austria; 2University of Applied Sciences Upper Austria, Austria; [email protected] 1 Analyzing wood bark insulation board structure using X-ray computed tomography and modeling its thermal conductivity by means of finite difference method Günther Kain1,2, Johann Charwat-Pessler1, Marius-Catalin Barbu1,3, Bernhard Plank4, Klaus Richter2, Alexander Petutschnigg5 1 Salzburg University of Applied Sciences, Austria; 2Technische Universität München, Germany; 3Faculty for Wood Engineering, University "Transilvania", Brasov, Romania; 4School of Engineering and Environmental Sciences, University of Applied Sciences Upper Austria, Wels, Austria; 5Institute of Wood Science and Technology, University of Natural Resources and Life Sciences, Vienna, Austria; [email protected] Comparision of different segmentation methods for porosity evaluation in CFRP-reference samples and comparison with real porosity samples Guruprasad Rao, Bernhard Plank, Johann Kastner University of Applied Sciences Upper Austria, Austria; [email protected] 14/01/2016 21:48 NDT1: Manufacturing, NDT and instrumentation (I) Time: Wednesday, 10/Feb/2016: 1:50pm - 3:50pm · Location: Building A, Auditorium High energy CT of illegal cargo mockups to generate X-ray images for a reference data base used for cargo inspection Alexander Flisch1, Thomas Lüthi1, Mathieu Plamondon1, Stefan Hartmann1, Wicher Visser2, Adrian Schwaninger2, Diana Hardmeier2, Marius Costin3, Caroline Vienne3, Frank Sukowski4, Ulf Hassler4, Irène Dorion5, Andrea Canonica6, Eric Rochat6, Ger Koomen7, Micha Slegt7 1 Empa. Swiss Federal Laboratories for Materials Science and Technology, Center for X-ray Analytics, Switzerland; 2Center of Adaptive Security Research and Applications, Switzerland; 3CEA LIST, Department of Imaging & Simulation for NonDestructive Testing, France; 4Fraunhofer Institute for Integrated Circuits IIS, Development Center for X-ray Technology, Germany; 5Smiths Heimann S.A.S., France; 6Swiss Federal Customs Administration, Switzerland; 7Dutch Tax and Customs Administration, Dutch Customs Laboratory, The Netherlands; [email protected] Comparing Cone Beam Laminographic System Trajectories for Composite NDT Neil Stephen O'Brien, Mark Noel Mavrogordato, Ian Sinclair, Thomas Blumensath University of Southampton, United Kingdom; [email protected] Automatic Object Position Recognition: Increasing the Position-Accuracy in Robot-CT Philipp Klein, Frank Herold YXLON International GmbH, Germany; [email protected] Investigation on Effect of scintillator thickness on image lag in Indirect- Flat Panel Detectors Karim Zarei Zefreh1, Jan De Beenhouwer1, Federica Marone Welford2, jan Sijbers1 iMinds-Visionlab, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium; 2X-ray Tomography Group, Swiss Light Source, WBBA/216, CH-5232 Villigen, switzerland; [email protected] 1 Reference object for accuracy evaluation of porosity measurements by X-ray Computed Tomography Petr Hermanek, Simone Carmignato University of Padova, Italy; [email protected] Fast X-ray CT of the low attenuation specimen during loading experiment Ivana Kumpova1, Tomas Fila2, Petr Koudelka1, Daniel Vavrik1, Ivan Jandejsek1, Jan Jakubek1, Daniel Kytyr2, Ana Gantar3 1 The Institute of Theoretical and Applied Mechanics AS CR, v. v. i., Telc; 2The Institute of Theoretical and Applied Mechanics AS CR, v. v. i., Prague; 3Jožef Stefan Institute, Department for Nanostructured Materials, Slovenia; [email protected] 14/01/2016 21:48 NDT2: Manufacturing, NDT and instrumentation (II) Time: Wednesday, 10/Feb/2016: 4:20pm - 5:20pm · Location: Building A, Auditorium Comparison of Different Additive Manufacturing Methods Using Optimized Computed Tomography Paras Shah, Radu Racasan, Paul Bills Centre for Precision Technolgies, University of Huddersfield, United Kingdom; [email protected] CT-based quality control of Laser Sintering of Polymers Michele Pavan1,2, Tom Craeghs1, Jean-Pierre Kruth2, Wim Dewulf2 1 Materialise NV, Belgium; 2KULeuven, Belgium; [email protected] Parametric design in Reverse Engineering based on CT data Dirk Hofmann, Philipp Sembdner, Stefan Holtzhausen, Christine Schöne, Ralph Stelzer Dresden University of Technology, Germany; [email protected] 14/01/2016 21:48 SHT: Short talks (5 mins) Time: Wednesday, 10/Feb/2016: 5:20pm - 6:40pm · Location: Building A, Auditorium Fast X-ray Computed Tomography via Image Completion Luis Filipe Alves Pereira1,2, Eline Janssens3, Mattias Van Dael4, Pieter Verboven4, Bart Nicolai4, George Darmiton Cavalcanti1, Ing Ren Tsang1, Jan Sijbers3 1 Universidade Federal de Pernambuco, Brazil; 2Universidade Federal Rural de Pernambuco, Brazil; 3University of Antwerp, Belgium; 4KU Leuven, Belgium; [email protected] Analysis and comparison of the surface filtering characteristics of computed tomography and tactile measurements Mario Salzinger Fraunhofer-Institut für Integrierte Schaltungen IIS, Germany; [email protected] Noncircular scanning trajectory for sparse-view computed laminography Seungryong Cho1, Park Miran1, Cho Gyuseong1, Park Jinkeun2 KAIST, Korea, Republic of (South Korea); 2Techvalley Co., Sungnam, (Korea); [email protected] 1 Industrial Tomography System for Answering Biological Issues: Development of the Mouse Embrya Face. Tomáš Zikmund1, Marketa Tesařová1, Josef Jaroš2, Markéta Kaucká3, Igor Adameyko3, Jozef Kaiser1 Brno University of Technology CEITEC BUT – Central European Institute of Technology, 616 00 Brno, Czech Republic; 2 Department of Histology and Embryology, Medical Faculty, Masaryk University, Brno, 62500, Czech Republic; 3Department of Physiology and Pharmacology, Karolinska Institutet, Stockholm 17177, Sweden; [email protected] 1 An automated sinogram-space ring artifact reduction method in computed tomography Junhyuk Yoon1, YoungGeun Lee1, Kyoonyun Kim2, Yeong Gil Shin1 Seoul National University, Republic of Korea; 2D Industrial Imaging, Republic of Korea; [email protected] 1 Effects of X-ray Penetration Depth on Multi-Material Measurements using Industrial Computed Tomography Anton Jansson, Amir Reza Zekavat, Lars Pejryd University of Örebro, Sweden; [email protected] Investigation on metrological performances in CT helical scanning for dimensional quality control Valentina Aloisi1, Simone Carmignato1, Joseph Schlecht2, Eric Ferley2 University of Padova, Italy; 2North Star Imaging, Inc., Rogers, MN, USA; [email protected] 1 Influence of defect shapes on detection using PoD Emmanuel Manu Dabankah, Stefan Kasperl Fraunhofer EZRT, Germany; [email protected] Use of X-ray micro-computed tomography in pharmaceuticals and food industry Franziska Sondej, Christian Rieck, Martin Schmidt, Andreas Bück, Evangelos Tsotsas Otto-von-Guericke University, Germany; [email protected] Standing tree tomography using sound attenuation data Asghar Golhasani, Mehran Roohnia, Hesamoddin Derili Karaj Branch, Islamic Azad University, Iran, Islamic Republic of; [email protected] 14/01/2016 21:48 POSTER: poster exhibition Time: Wednesday, 10/Feb/2016: 6:40pm - 8:30pm · Location: Building A, Exhibition area Selection of items for interlaboratory “InteraqCT Comparison on Assemblies” Alessandro Stolfi, Leonardo De Chiffre Technical University of Denmark, Denmark; [email protected] Accuracy Enhancement of CT Measurements using Data Filtering Alessandro Stolfi, Leonardo De Chiffre Technical University of Denmark; [email protected] Advanced Fiber Evaluation Workflows Peter Westenberger1, Rémi Blanc2 FEI, Germany; 2FEI SAS, France; [email protected] 1 Development of 3D morphological descriptors for agglomerate with complex structure Reihaneh Pashminehazar, Abdolreza Kharaghani, Evangelos Tsotsas Otto Von Guericke University Magdeburg, Germany; [email protected] CIVA CT, an advanced simulation platform for NDT Marius Costin1, Hussein Banjak1, Caroline Vienne1, David Tisseur1, Ronan Guillamet1, Roman Fernandez2 1 CEA LIST, Department of Imaging & Simulation for Non-Destructive Testing, 91191 Gif-sur-Yvette, France; 2EXTENDE, Le Bergson, 15 Avenue Emile Baudot, 91300 Massy, France; [email protected] Modeling of the method to determine the Bremsstrahlung focal spot size for the accelerator V.I. Bespalov2, Vladimir Sorokin1, Talgat Mamyrbayev1 Institute of Non-Destructive Testing, National Research Tomsk Polytechnic University, Russian Federation; 2Institute of Physics and Technology, National Research Tomsk Polytechnic University, Russian Federation; [email protected] 1 On the Influence of Ring Artifacts on Dimensional Measurement in Industrial Computed Tomography Dierck Emil Otto Matern, Frank Herold, Thomas Wenzel YXLON International GmbH, Germany; [email protected] Compensation of drift in an industrial computed tomography system Gabriel Maurício Probst, Jean-Pierre Kruth, Wim Dewulf KU Leuven, Belgium; [email protected] An investigation into CT uncertainty for industrial use Lonnie Andersen, Maria Holmberg Danish Technological Institute, Denmark; [email protected] SimCT: a simulations tool for X-ray imaging Michael Reiter1, Marco Erler2, Christoph Kuhn2, Christian Gusenbauer1, Johann Kastner1 1 University of Applied Sciences Upper Austria, Austria; 2Carl Zeiss IMT, Germany; [email protected] 4D X-ray tomography based on a level set method Paola Elefante, Matti Lassas, Alexander Meaney, Esa Niemi, Samuli Siltanen University of Helsinki, Finland; [email protected] Frequency-based method to optimize the number of projections for industrial computed tomography Andrea Buratti, Robert Schmitt, Sofian Ben Achour, Christopher Isenberg Laboratory for Machine Tools and Production Engineering (WZL) of RWTH Aachen University, Germany; [email protected] Experimental study of metrological CT system settings for the integrity analysis of turbine shaft-wheel assembly weld joint 14/01/2016 21:48 Crhistian Raffaelo Baldo1, Thiago Souza Coutinho2, Gustavo Daniel Donatelli2 Federal University of ABC - UFABC, Brazil; 2Reference Centers in Innovative Technologies - CERTI, Brazil; [email protected] 1 Computed tomography in fossils Kudakwashe Jakata Evolutionary Studies Institute, University of the Witwatersrand, South Africa; [email protected] Comparison of Surface-based and Image-based Quality Metrics for the Analysis of Dimensional Computed Tomography Data Francisco Augusto Arenhart1, Vitor Camargo Nardelli2, Gustavo Daniel Donatelli3 Federal University of Santa Catarina, Florianópolis, Brazil; 2National Service for Industrial Training, Brasília, Brazil; 3CERTI Foundation, Florianópolis, Brazil; [email protected] 1 Multi-modal imaging as a promising approach to the understanding of wheat-dough microstructures Katrin Mathmann, Helmut Zauner, Christoph Heinzl, Johann Kastner University of Applied Sciences Upper Austria, Austria; [email protected] Determination of implant materials corrosion properties based on tomographic data Thomas Dose Helmholtz-Zentrum Geesthacht, Germany; [email protected] Computer-assisted tomography analysis of high-strength fiber ropes Annett Schmieder1, Thorsten Heinze2, Markus Michael3 Technische Universität Chemnitz, Germany; 2Technische Universität Chemnitz, Germany; 3Technische Universität Chemnitz, Germany; [email protected] 1 In-Situ CT Investigation of Pull-Out Failure for Reinforcing Bars Embedded in Conventional and HighPerformance Concretes Tyler Oesch Bundesanstalt für Materialforschung und –prüfung (BAM), Germany; [email protected] CT for Additive Manufacturing Process Characterisation: Assessment of melt strategies on defect population Fabien Léonard1, Samuel Tammas-Williams2, Iain Todd2 Bundesanstalt für Materialforschung und –prüfung (BAM), Germany; 2University of Sheffield, Department of Materials Science and Engineering, UK; [email protected] 1 14/01/2016 21:48 MET1: Metrology (I) Time: Thursday, 11/Feb/2016: 9:30am - 10:30am · Location: Building A, Auditorium ISO test survey on material influence in dimensional computed tomography Markus Bartscher, Jens Illemann, Ulrich Neuschaefer-Rube Physikalisch-Technische Bundesanstalt PTB, Germany; [email protected] Numerical measurement uncertainty determination for dimensional measurements of microparts with CT Eric Helmecke1, Matthias Fleßner1, Andreas Staude2, Tino Hausotte1 Friedrich-Alexander Universität Erlangen-Nürnberg, Germany; 2BAM Federal Institute for Materials Research and Testing, Germany; [email protected] 1 Quality evaluation of X-ray computed tomography volume data in dimensional metrology Lin Xue1, Hiromasa Suzuki1, Yutaka Ohtake1, Hiroyuki Fujimoto2, Makoto Abe2, Osamu Sato2, Toshiyuki Takatsuji2 1 The University of Tokyo, Japan; 2National Institute of Advanced Industrial Science and Technology (AIST), Japan; [email protected] 14/01/2016 21:48 MET2: Metrology (II) Time: Thursday, 11/Feb/2016: 11:00am - 12:40pm · Location: Building A, Auditorium Influence of surface roughness on X-ray computed tomography dimensional measurements of additive manufactured parts Valentina Aloisi, Simone Carmignato University of Padova, Italy; [email protected] Experimental assessment of computed tomography dimensional performance using modular test pieces made of polyoxymethylene and aluminum Crhistian Raffaelo Baldo1, Thiago Linhares Fernandes2, Gustavo Daniel Donatelli2 Federal University of ABC - UFABC, Brazil; 2Reference Centers in Innovative Technologies - CERTI, Brazil; [email protected] 1 Development of test bodies for deployment in industrial Computed Tomography Alexandra Kraemer, Ankur Batra, Gisela Lanza Karlsruhe Institute of Technology, Germany; [email protected] Assessment of the single point uncertainty of dimensional CT measurements Matthias Fleßner, Andreas Müller, Daniela Götz, Eric Helmecke, Tino Hausotte Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Germany; [email protected] Novel evaluation method of low contrast resolution performance of dimensional X-ray CT Makoto Abe, Hiroyuki Fujimoto, Osamu Sato, Kazuya Matsuzaki, Toshiyuki Takatsuji National Metrology Institute of Japan (NMIJ/AIST), Japan; [email protected] 14/01/2016 21:48 MET3: Metrology (III) Time: Thursday, 11/Feb/2016: 1:40pm - 2:40pm · Location: Building A, Auditorium Metrological evaluation and application of a region-based surface extraction method for material separation in CT volume data Julia Denecke1, Ira Effenberger1, Alexander Verl2 Fraunhofer IPA, Stuttgart, Germany; 2Fraunhofer Headquarter, Munich, Germany; [email protected] 1 Experimental Investigation of the Influence Factors on the Structural Resolution for Dimensional Measurements with CT Systems Francisco Augusto Arenhart1, Crhistian Raffaelo Baldo3, Thiago Linhares Fernandes2, Gustavo Daniel Donatelli2 Federal University of Santa Catarina, Florianópolis, Brazil; 2CERTI Foundation, Florianópolis, Brazil; 3Federal University of ABC - UFABC, Brazil; [email protected] 1 Experimental Investigation of Surface Determination Process on Multi-material Components for Dimensional Computed Tomography Fabrício Borges de Oliveira1, Alessandro Stolfi2, Markus Bartscher1, Leonardo De Chiffre2, Ulrich Neuschaefer-Rube1 1 Physikalisch-Technische Bundesanstalt (PTB), Germany; 2Technical University of Denmark (DTU), Denmark; [email protected] 14/01/2016 21:48 REC1: Reconstruction (I) Time: Thursday, 11/Feb/2016: 2:40pm - 3:40pm · Location: Building A, Auditorium Simulation-Based Metal Artifact Reduction for Computed Tomography of Multi-Material Components Joscha Maier1,2, Carsten Leinweber1,2, Stefan Sawall1, Henning Stoschus2, Tobias Müller2, Michael Hammer2, Ralf Christoph2, Marc Kachelrieß1 1 German Cancer Research Center (DKFZ), Germany; 2Werth Messtechnik GmbH, Germany; [email protected] Discrete tomographic reconstruction from deliberately motion blurred X-ray projections Wim van Aarle1, Jeroen Cant1,2, Jan De Beenhouwer1, Jan Sijbers1 iMinds - Vision Lab, University of Antwerp, Wilrijk, Belgium; 2Agfa Healthcare NV, Mortsel, Belgium; [email protected] 1 Fast Inline Inspection of Apples by a Neural Network based Filtered Backprojection Method Eline Janssens1, Luis F. Alves Pereira2,3, Jan De Beenhouwer1, Mattias Van Dael4, Pieter Verboven4, Bart Nicolaï4, Jan Sijbers1 1 iMinds-VisionLab, University of Antwerp, Belgium; 2Unidade Acadêmica de Garanhuns, Universidade Federal Rural de Pernambuco, Brasil; 3Centro de Informática, Universidade Federal de Pernambuco, Brasil; 4BIOSYST-MeBios, KU Leuven, Belgium; [email protected] 14/01/2016 21:48 ALG: Algorithms, optimisations and visualisations Time: Thursday, 11/Feb/2016: 4:10pm - 5:30pm · Location: Building A, Auditorium Efficient Iterative CT Reconstruction on Octree Guided by Geometric Errors Seungki Kim1, Akitsune Sakane1, Yutaka Ohtake1, Hiromasa Suzuki1, Yukie Nagai1, Katsutoshi Sato2, Hiroyuki Fujimoto3, Makoto Abe3, Osamu Sato3, Toshiyuki Takatsuji3 1 The University of Tokyo, Japan; 2Hitachi, Japan; 3National Institute of Advanced Industrial Science and Technology, Japan; [email protected] A novel Method for Determination of Fiber Length Distributions from µCT-data Pascal Pinter, Benjamin Bertram, Kay André Weidenmann KIT / IAM-WK, Germany; [email protected] Interactive Visual Exploration of Fiber Bundles and Weaving Patterns from X-ray Computed Tomography Scans of Carbon Fiber-Reinforced Polymers Johannes Weissenböck1, Bernhard Plank1, Arindam Bhattacharya2, Christoph Heinzl1, Johann Kastner1 University of Applied Sciences Upper Austria - Wels Campus; 2The Ohio State University; [email protected] 1 The MUSICES Project: Simulative automated CT acquisition planning for historical brass instruments improves image quality Richard Schielein1,2, Gabriele Scholz2, Rebecca Wagner2, Christian Kretzer2, Theobald Fuchs2, Stefan Kasperl2, Frank Bär3, Sebastian Kirsch3, Markus Zepf3, Meike Wolters-Rosbach3 1 University of Wuerzburg, Germany; 2Fraunhofer Development Center of X-ray Technology EZRT, Germany; 3Germanisches Nationalmuseum, Germany; [email protected] 14/01/2016 21:48 GIM: Grating Interferometer Time: Friday, 12/Feb/2016: 9:30am - 10:10am · Location: Building A, Auditorium Characterization of medical and biological samples with a Talbot-Lau grating interferometer XCT in comparison to reference methods Christian Gusenbauer1, Sascha Senck1, Katrin Mathmann1, Johann Kastner1, Stefan Hunger2, Elisabeth Leiss3, Wolfgang Birkfellner4 1 University of Applied Sciences Upper Austria, Campus Wels; 2Johannes Kepler University Linz, Faculty of Medicine; 3 Research Center for Non Destructive Testing GmbH; 4Medical University Vienna, Physics and Biomedical Engineering; [email protected] Automatic Grating Alignment for a Talbot-Lau Interferometer Rolf Kaufmann, Stefan Hartmann, Mario Beltran, Antonia Neels Empa, Switzerland; [email protected] 14/01/2016 21:48 MUL: Multi-modal and multi-energy Time: Friday, 12/Feb/2016: 10:40am - 11:40am · Location: Building A, Auditorium Improving CT quality control of a micro injection moulded part by multisensor data fusion Jitendra Singh Rathore, Simone Carmignato University of Paodva, Italy; [email protected] Dual energy tomographic inspection of the carbon fiber reinforced plastic composite combined with metal components Daniel Vavrik1,2, Tomas Fila1, Jan Jakubek1, Ivana Kumpova1, Martin Pichotka2 Institute of Theoretical and Applied Mechanics, Centre of Excellence Telc; 2Institute of Experimental and Applied Physics, CTU in Prague, Czech Republic; [email protected] 1 Combined neutron and X-ray imaging – imaging with a second opinion Anders Kaestner, David Mannes, Eberhard Lehmann Paul Scherrer Institut, Switzerland; [email protected] 14/01/2016 21:48 REC2: Reconstruction and corrections methods (II) Time: Friday, 12/Feb/2016: 12:10pm - 12:50pm · Location: Building A, Auditorium Multi-Material 3D Shape Reconstruction by Dual-Energy CT Imaging Mitsuru Negishi, Yutaka Ohtake, Hiromasa Suzuki, Yukie Nagai The University of Tokyo, Japan; [email protected] Continuous digital laminography Jeroen Cant1,2, Gert Behiels2, Jan Sijbers1 1 University of Antwerp, Belgium; 2Agfa Healthcare NV, Belgium; [email protected]
© Copyright 2025 ExpyDoc