Übersicht AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart SWL-5A 5 10 1 3000 10 Split core - EY51-6-655UQ 30 60 0 1000 10.1 Through hole - EY52-6-655UU 15 30 0 1000 4.5 Through hole PCB mount, vertical EY53-6-670UQ 30 50 0 1250 9.7 Through hole - EY56-0-655UQ 30 50 0 1000 9 Through hole - EY56-1-655UQ 100 125 0 1000 14.7 Through hole - SWL-50A 50 100 1 3000 10 Split core - EY56-6-655UQ 15 30 0 1000 6.7 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart EY56-7-655UQ 30 50 0 1000 9 Through hole - SWL-100A 100 200 1 3000 16 Split core - EY56-8-655UQ 50 70 0 1000 10.5 Through hole - EY56-9-655UQ 100 125 0 1000 14.7 Through hole - SWL-200A 200 300 1 3000 24 Split core - EY58-6-655UU 15 30 0 1000 6.8 Through hole PCB mount, horizontal SWXT-100A 100 120 1 100 35 Split core - EY58-8-655UU 15 25 0 1000 5.1 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart SWXT-200A 200 240 1 200 35 Split core - SWXT-300A 300 360 1 60 35 Split core - SWXT-400A 400 480 1 80 35 Split core - SWXT-600A 600 720 1 120 35 Split core - SWL-100Y 100 120 1 100 24 Split core - SWL-200Y 200 240 1 200 35 Split core - SWL-400Y 400 480 1 400 35 Split core - SWL-400A 400 600 1 6000 35 Split core - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart EY59-6-655UU 15 30 0 1000 6.7 Through hole PCB mount, horizontal EY66-7-655UU 15 30 0 1000 5.8 Through hole PCB mount, horizontal SWL-600A 600 800 1 9000 35 Split core - EY66-8-655UU 15 30 0 1000 5.8 Through hole PCB mount, vertical HX56-6-505 10 - 0 50 5 Through hole PCB mount, vertical KSWL-1-03 8 10 5 800 3 Split core - HX56-6-505(7) 24 - 0 50:50:00 5 Through hole PCB mount, vertical HX56-6-570(7) 10 - 0 25:25:00 5 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HX56-6-605(7) 35 - 0 150:150 5 Through hole PCB mount, vertical HX56-6-655 24 - 0 100 5 Through hole PCB mount, vertical HX56-6-655(7) 30 - 0 100:100 5 Through hole PCB mount, vertical HX56-6-755 30 - 0 200 5 Through hole PCB mount, vertical SW52-6-505-U 5 10 0.5 500 5 Through hole PCB mount, vertical HX56-6-855 35 - 0 300 5 Through hole PCB mount, vertical HX56-7-505 10 - 0 50 10 Through hole PCB mount, horizontal HX56-7-655 24 - 0 100 10 Through hole PCB mount, horizontal AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HX56-7-755 30 - 0 200 10 Through hole PCB mount, horizontal SW52-6-505-X 15 30 5 500 5 Through hole PCB mount, vertical HX56-7-855 35 - 0 300 10 Through hole PCB mount, horizontal HX56-8-055 40 - 0 500 4.4 Through hole PCB mount, vertical SW65-6-655-U 5 15 0.5 1000 6.9 Through hole PCB mount, vertical HX56-8-205 50 - 0 750 4.4 Through hole PCB mount, vertical HX56-8-6555 80 - 0 1000 4.4 Through hole PCB mount, vertical SW53-6-655-F 10 20 0.5 1000 6.9 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HX57-6-055 40 - 0 500 - - PCB mount, vertical HX57-6-205 50 - 0 750 - - PCB mount, vertical SW65-6-605-F 15 30 0.5 1500 6.9 Through hole PCB mount, vertical HX57-6-505 10 - 0 50 - - PCB mount, vertical HX57-6-655 24 - 0 100 - - PCB mount, vertical SW65-6-755-U 20 45 0.2 2000 6.9 Through hole PCB mount, vertical HX57-6-6555 80 - 0 1000 - - PCB mount, vertical HX57-6-755 30 - 0 200 - - PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart SW65-6-705-F 30 70 0.2 2500 6.9 Through hole PCB mount, vertical HX57-6-855 35 - 0 300 - - PCB mount, vertical HY50-0-655X 10 15 0.2 1000 4,5 Through hole PCB mount, vertical SW53-6-655-X 40 90 3 1000 6.9 Through hole PCB mount, vertical HY50-0-655X 10 15 0.2 1000 4,5 Through hole PCB mount, vertical HY50-1-535U 10 20 1 800 5,8 Through hole PCB mount, vertical SW53-6-755-X 50 100 0.5 2000 6.9 Through hole PCB mount, vertical HY50-1-535X 10 80 3 800 5,8 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY50-2-605U 10 18 3 1500 5,7 Through hole PCB mount, vertical SW53-6-605-X 60 120 1 1500 6.9 Through hole PCB mount, vertical HY50-2-755U 5 10 0.2 2000 5,7 Through hole PCB mount, vertical HY50-6-505U 5 10 5 500 5,7 Through hole PCB mount, horizontal SW53-6-705-X 75 165 1 2500 6.9 Through hole PCB mount, vertical HY50-6-505X 2 6 5 500 5,7 Through hole PCB mount, horizontal HY50-6-535F 10 20 5 800 5,7 Through hole PCB mount, horizontal SW65-7-655-F 15 40 0.5 1000 8.9 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY50-6-535X 10 40 5 800 5,7 Through hole PCB mount, horizontal HY50-6-655F 10 20 5 1000 5,7 Through hole PCB mount, horizontal SW65-7-755-U 30 60 0.5 2000 8.9 Through hole PCB mount, vertical HY50-6-655U 4 5 3 1000 5,7 Through hole PCB mount, horizontal HY50-6-655X 10 20 5 1000 5,7 Through hole PCB mount, horizontal SW65-7-605-F 20 60 0.2 1500 8.9 Through hole PCB mount, vertical HY50-7-655X 10 20 10 1000 5,1 Through hole PCB mount, vertical HY50-8-655U 5 12 3 1000 4,5 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart SW65-7-705-F 50 100 0.1 2500 8.9 Through hole PCB mount, vertical HY50-8-655X 10 20 10 1000 4,5 Through hole PCB mount, vertical HY50-9-655X 2 10 5 1000 6,8 Through hole PCB mount, horizontal SW65-7-605-X 60 145 1 1500 8.9 Through hole PCB mount, vertical HY51-6-505U 3 5 10 500 5,8 Through hole - HY51-6-655U 6 10 10 1000 5,8 Through hole - SW61-8-605-X 75 240 0.5 1500 8.9 Through hole PCB mount, vertical HY52-6-505U 5 10 5 500 5,9 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY52-6-505X 10 30 10 500 5,9 Through hole PCB mount, vertical SW61-8-755-X 100 370 0.5 2000 8.9 Through hole PCB mount, vertical HY52-6-575U 5 10 20 200 5,9 Through hole PCB mount, vertical HY52-6-655F 10 20 10 1000 5,9 Through hole PCB mount, vertical SW79-6-855-R 30 60 3 3000 10.7 Split core - HY52-6-655U 10 20 5 1000 5,9 Through hole PCB mount, vertical HY52-6-655X 10 20 10 1000 5,9 Through hole PCB mount, vertical SW56-6-505-X 5 10 10 500 11 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY53-6-055F 50 80 0.2 5000 6,9 Through hole PCB mount, vertical HY53-6-055U 50 80 0.1 5000 6,9 Through hole PCB mount, vertical SW56-6-520-X 15 30 10 750 11 Through hole PCB mount, vertical HY53-6-605F 15 30 0.2 1500 6,9 Through hole PCB mount, vertical HY53-6-605U 15 30 0.2 1500 6,9 Through hole PCB mount, vertical SW56-6-655-X 25 55 10 1000 11 Through hole PCB mount, vertical HY53-6-605X 50 100 1 1500 6,9 Through hole PCB mount, vertical HY53-6-655F 10 20 0.5 1000 6,9 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart SW65-8-655-F 25 50 0.5 1000 12.8 Through hole PCB mount, vertical HY53-6-655U 10 15 0.2 1000 6,9 Through hole PCB mount, vertical HY53-6-655X 40 90 1 1000 6,9 Through hole PCB mount, vertical SW65-8-605-U 30 70 0.2 1500 12.8 Through hole PCB mount, vertical HY53-6-705F 25 45 0.2 2500 6,9 Through hole PCB mount, vertical HY53-6-705U 25 45 0.1 2500 6,9 Through hole PCB mount, vertical SW65-8-755-U 50 100 0.2 2000 12.8 Through hole PCB mount, vertical HY53-6-705X 75 165 1 2500 6,9 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY53-6-755F 20 40 0.2 2000 6,9 Through hole PCB mount, vertical SW65-8-705-F 75 150 0.1 2500 12.8 Through hole PCB mount, vertical HY53-6-755U 20 40 0.2 2000 6,9 Through hole PCB mount, vertical HY53-6-755X 60 120 0.5 2000 6,9 Through hole PCB mount, vertical SW65-8-605-X 75 200 1 1500 12.8 Through hole PCB mount, vertical HY54-0-605U 15 25 0.5 1500 6,9 Through hole - HY54-0-605X 25 50 1 1500 6,9 Through hole - SW65-8-705-X 200 435 0.5 2500 12.8 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY54-0-655U 5 15 0.5 1000 6,9 Through hole - HY54-0-655X 20 45 3 1000 6,9 Through hole - SW66-6-655-U 20 40 0.5 1000 14 Through hole - HY54-0-705U 25 45 0.2 2500 6,9 Through hole - HY54-0-705X 40 150 1 2500 6,9 Through hole - SW66-6-605-U 30 75 0.2 1500 14 Through hole - HY54-0-755U 20 40 0.2 2000 6,9 Through hole - HY54-0-755X 35 110 1 2000 6,9 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart SW66-6-755-U 40 95 0.2 2000 14 Through hole - HY54-1-605U 30 50 0.5 1500 9,0 Through hole - HY54-1-605X 40 120 1 1500 9,0 Through hole - SW66-6-655-X 50 130 1 1000 14 Through hole - HY54-1-655U 25 20 0.5 1000 9,0 Through hole - HY54-1-655X 30 75 3 1000 9,0 Through hole - SW66-6-705-U 75 150 0.2 2500 14 Through hole - HY54-1-705U 50 85 0.2 2500 9,0 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY54-1-705X 75 200 1 2500 9,0 Through hole - SW66-6-755-X 100 260 0.5 2000 14 Through hole - HY54-1-755U 30 65 0.2 2000 9,0 Through hole - HY54-1-755X 50 140 1 2000 9,0 Through hole - SW66-6-705-X 100 430 0.5 2500 14 Through hole - HY54-2-605U 35 75 0.2 1500 13,0 Through hole - HY54-2-605X 75 250 1 1500 13,0 Through hole - SW79-8-855-R 100 120 3 3000 16 Split core - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY54-2-655U 30 45 0.2 1000 13,0 Through hole - HY54-2-655X 60 130 1 1000 13,0 Through hole - SW65-9-655-U 40 80 0.5 2000 18 Through hole PCB mount, vertical HY54-2-705U 80 145 0.2 2500 13,0 Through hole - HY54-2-705X 150 420 0.5 2500 13,0 Through hole - SW65-9-605-U 60 140 0.2 2000 18 Through hole PCB mount, vertical HY54-2-755U 50 130 0.2 2000 13,0 Through hole - HY54-2-755X 100 360 0.5 2000 13,0 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart SW65-9-755-U 100 200 0.2 2000 18 Through hole PCB mount, vertical HY54-6-605U 7 15 1 1500 9,0 Through hole - HY54-6-605X 15 40 3 1500 9,0 Through hole - SW65-9-605-X 150 660 0.5 2000 18 Through hole PCB mount, vertical HY54-6-655U 5 10 1 1000 9,0 Through hole - HY54-6-655X 20 40 3 1000 9,0 Through hole - SW65-9-755-X 200 950 0.5 2000 18 Through hole PCB mount, vertical HY54-6-705X 35 70 3 2500 9,0 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY54-6-755U 10 25 1 2000 9,0 Through hole - SW65-9-705-X 250 1100 0.5 2000 18 Through hole PCB mount, vertical HY54-6-755X 35 60 3 2000 9,0 Through hole - HY54-7-605U 15 30 1 1500 14,7 Through hole - SW79-9-655-U 5 15 10 1000 23 Split core - HY54-7-605X 25 55 3 1500 14,7 Through hole - HY54-7-655U 10 20 1 1000 14,7 Through hole - SW79-9-605-U 15 35 10 1500 23 Split core - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY54-7-655X 20 40 3 1000 14,7 Through hole - HY54-7-705U 25 50 0.5 2500 14,7 Through hole - SW79-9-755-U 20 50 10 2000 23 Split core - HY54-7-755U 20 40 0.5 2000 14,7 Through hole - HY54-7-755X 40 95 3 2000 14,7 Through hole - SW57-6-655-X 50 115 3 1000 23 Through hole - HY54-8-605U 10 20 1 1500 10,5 Through hole - HY54-8-605X 30 70 3 1500 10,5 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart SW57-6-605-X 75 205 1 1500 23 Through hole - HY54-8-655U 5 15 1 1000 10,5 Through hole - HY54-8-655X 20 40 3 1000 10,5 Through hole - SW57-6-755-X 100 310 1 2000 23 Through hole - HY54-8-705U 20 40 0.5 2500 10,5 Through hole - HY54-8-755U 15 30 0.5 2000 10,5 Through hole - SW57-6-705-X 100 435 1 2500 23 Through hole - HY54-8-755X 60 100 3 2000 10,5 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY54-9-655U 2 5 1 1000 6,7 Through hole - HY54-9-655X 5 20 10 1000 6,7 Through hole - HY59-6-535X 6 30 3 800 5,9 Through hole PCB mount, vertical SW57-6-655-U 10 20 1 1000 27 Through hole - HY59-6-605X 30 95 1 1500 5,9 Through hole PCB mount, vertical HY59-6-655X 20 45 3 1000 5,9 Through hole PCB mount, vertical SW57-6-605-U 15 40 0.5 1500 27 Through hole - HY59-6-755X 60 120 1 2000 5,9 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY59-8-605X 60 120 1 1500 14,0 Through hole PCB mount, vertical SW57-6-755-U 30 70 0.5 2000 27 Through hole - HY59-8-655X 30 60 3 1000 14,0 Through hole PCB mount, vertical HY59-8-755X 60 120 1 2000 14,0 Through hole PCB mount, vertical SW57-6-705-U 25 95 0.2 2500 27 Through hole - HY59-9-535X 40 90 3 800 12,0 Through hole PCB mount, vertical HY59-9-595X 10 25 5 400 12,0 Through hole PCB mount, vertical SW79-7-705-R 40 80 3 2500 26.9 x 20.6 Split core - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY59-9-605U 30 60 0.2 1500 12,0 Through hole PCB mount, vertical HY59-9-605X 75 210 1 1500 12,0 Through hole PCB mount, vertical SW79-7-955-R 50 100 3 4000 26.9 x 20.6 Split core - HY59-9-655U 15 35 0.5 1000 12,0 Through hole PCB mount, vertical HY59-9-655X 60 120 1 1000 12,0 Through hole PCB mount, vertical HY59-9-705U 50 115 0.2 2500 12,0 Through hole PCB mount, vertical HY59-9-755U 40 90 0.2 2000 12,0 Through hole PCB mount, vertical HY61-6-605X 30 100 5 1500 8,9 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY61-6-655X 20 60 5 1000 8,9 Through hole PCB mount, vertical HY61-6-705X 75 150 0.5 2500 8,9 Through hole PCB mount, vertical HY61-6-755X 60 120 3 2000 8,9 Through hole PCB mount, vertical HY61-7-605X 75 195 3 1500 12,6 Through hole PCB mount, vertical HY61-7-655X 40 80 3 1000 12,6 Through hole PCB mount, vertical HY61-7-705X 100 380 0.5 2500 12,6 Through hole PCB mount, vertical HY61-7-755X 80 200 0.5 2000 12,6 Through hole PCB mount, vertical HY61-8-605X 75 240 0.5 1500 9,5 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY61-8-655X 40 100 1 1000 9,5 Through hole PCB mount, vertical HY61-8-705X 120 300 0.5 2500 9,5 Through hole PCB mount, vertical HY61-8-755X 100 370 0.5 2000 9,5 Through hole PCB mount, vertical HY62-6-5505Q 50 - 3 10 26,4 Through hole - HY62-6-5515Q 60 - 2 12 26,4 Through hole - HY62-6-5520Q 75 - 2 15 26,4 Through hole - HY62-6-5535Q 80 - 2 16 26,4 Through hole - HY62-6-5605Q 150 - 1 30 26,4 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY62-6-5655Q 100 - 1 20 26,4 Through hole - HY62-6-5670Q 125 - 1 25 26,4 Through hole - HY62-6-5675Q 120 - 1 24 26,4 Through hole - HY62-6-5705Q 250 - 1 50 26,4 Through hole - HY62-6-5755Q 200 - 1 40 26,4 Through hole - HY62-6-5855Q 300 - 1 60 26,4 Through hole - HY62-7-5055Q 500 - 1 100 39,6 Through hole - HY62-7-5155Q 600 - 1 120 39,6 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY62-7-5205Q 750 - 1 150 39,6 Through hole - HY62-7-5355Q 800 - 1 160 39,6 Through hole - HY62-7-5505Q 50 - 2 10 39,6 Through hole - HY62-7-5520Q 75 - 2 15 39,6 Through hole - HY62-7-5605Q 150 - 1 30 39,6 Through hole - HY62-7-5655Q 100 - 2 20 39,6 Through hole - HY62-7-5705Q 250 - 1 50 39,6 Through hole - HY62-7-5755Q 200 - 1 40 39,6 Through hole - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY62-7-5855Q 300 - 1 60 39,6 Through hole - HY62-7-5955Q 400 - 1 80 39,6 Through hole - HY62-7-6555Q 1000 - 1 200 39,6 Through hole - HY62-7-6755Q 1200 - 1 240 39,6 Through hole - HY65-0-705F 60 240 0.5 2500 9,5 Through hole PCB mount, vertical HY65-6-605F 15 30 0.5 1500 7,0 Through hole PCB mount, vertical HY65-6-605U 15 20 0.2 1500 7,0 Through hole PCB mount, vertical HY65-6-605X 25 65 1 1500 7,0 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY65-6-655F 10 15 1 1000 7,0 Through hole PCB mount, vertical HY65-6-655U 10 15 0.5 1000 7,0 Through hole PCB mount, vertical HY65-6-655X 20 45 1 1000 7,0 Through hole PCB mount, vertical HY65-6-705F 30 70 0.5 2500 7,0 Through hole PCB mount, vertical HY65-6-705U 25 55 0.2 2500 7,0 Through hole PCB mount, vertical HY65-6-705X 50 200 0.5 2500 7,0 Through hole PCB mount, vertical HY65-6-755F 20 40 0.5 2000 7,0 Through hole PCB mount, vertical HY65-6-755U 20 45 0.2 2000 7,0 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY65-6-755X 30 105 0.5 2000 7,0 Through hole PCB mount, vertical HY65-7-605F 20 60 0.2 1500 8,9 Through hole PCB mount, vertical HY65-7-605U 20 55 0.2 1500 8,9 Through hole PCB mount, vertical HY65-7-605X 30 145 1 1500 8,9 Through hole PCB mount, vertical HY65-7-655F 15 40 0.5 1000 8,9 Through hole PCB mount, vertical HY65-7-655U 15 30 0.5 1000 8,9 Through hole PCB mount, vertical HY65-7-655X 20 70 3 1000 8,9 Through hole PCB mount, vertical HY65-7-705F 40 100 0.1 2500 8,9 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY65-7-705U 40 80 0.1 2500 8,9 Through hole PCB mount, vertical HY65-7-705X 80 280 0.5 2500 8,9 Through hole PCB mount, vertical HY65-7-755F 30 70 0.2 2000 8,9 Through hole PCB mount, vertical HY65-7-755U 30 60 0.2 2000 8,9 Through hole PCB mount, vertical HY65-7-755X 60 170 1 2000 8,9 Through hole PCB mount, vertical HY65-8-605F 30 100 0.2 1500 13,0 Through hole PCB mount, vertical HY65-8-605U 30 70 0.2 1500 13,0 Through hole PCB mount, vertical HY65-8-605X 40 200 0.5 1500 13,0 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY65-8-655F 20 50 0.5 1000 13,0 Through hole PCB mount, vertical HY65-8-655U 20 40 0.2 1000 13,0 Through hole PCB mount, vertical HY65-8-655X 30 65 1 1000 13,0 Through hole PCB mount, vertical HY65-8-705F 60 150 0.1 2500 13,0 Through hole PCB mount, vertical HY65-8-705U 60 145 0.1 2500 13,0 Through hole PCB mount, vertical HY65-8-705X 100 435 0.5 2500 13,0 Through hole PCB mount, vertical HY65-8-755F 60 120 0.2 2000 13,0 Through hole PCB mount, vertical HY65-8-755U 50 100 0.2 2000 13,0 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY65-8-755X 50 175 0.5 2000 13,0 Through hole PCB mount, vertical HY65-9-605U 60 140 0.2 1500 18,6 Through hole PCB mount, vertical HY65-9-605X 150 660 0.5 1500 18,6 Through hole PCB mount, vertical HY65-9-655U 40 80 0.5 1000 18,6 Through hole PCB mount, vertical HY65-9-655X 100 360 1 1000 18,6 Through hole PCB mount, vertical HY65-9-705U 120 315 0.1 2500 18,6 Through hole PCB mount, vertical HY65-9-705X 300 1100 0.5 2500 18,6 Through hole PCB mount, vertical HY65-9-755U 100 200 0.2 2000 18,6 Through hole PCB mount, vertical AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY65-9-755X 200 950 0.5 2000 18,6 Through hole PCB mount, vertical HY77-6-5505Y 50 - 3 10 28,4 Through hole Screw mount HY77-6-5515Y 60 - 2 12 28,4 Through hole Screw mount HY77-6-5520Y 75 - 2 15 28,4 Through hole Screw mount HY77-6-5535Y 80 - 2 16 28,4 Through hole Screw mount HY77-6-5605Y 150 - 1 30 28,4 Through hole Screw mount HY77-6-5655Y 100 - 1 20 28,4 Through hole Screw mount HY77-6-5670Y 125 - 1 25 28,4 Through hole Screw mount AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY77-6-5675Y 120 - 1 24 28,4 Through hole Screw mount HY77-6-5705Y 250 - 1 50 28,4 Through hole Screw mount HY77-6-5755Y 200 - 1 40 28,4 Through hole Screw mount HY77-6-5855Y 300 - 1 60 28,4 Through hole Screw mount HY77-7-5055Y 500 - 1 100 52,3 Through hole Screw mount HY77-7-5155Y 600 - 1 120 52,3 Through hole Screw mount HY77-7-5205Y 750 - 1 150 52,3 Through hole Screw mount HY77-7-5355Y 800 - 1 160 52,3 Through hole Screw mount AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY77-7-5605Y 150 - 1 30 52,3 Through hole Screw mount HY77-7-5655Y 100 - 1 20 52,3 Through hole Screw mount HY77-7-5705Y 250 - 1 50 52,3 Through hole Screw mount HY77-7-5755Y 200 - 1 40 52,3 Through hole Screw mount HY77-7-5855Y 300 - 1 60 52,3 Through hole Screw mount HY77-7-5955Y 400 - 1 80 52,3 Through hole Screw mount HY77-7-6055Y 1500 - 1 300 52,3 Through hole Screw mount HY77-7-6555Y 1000 - 1 200 52,3 Through hole Screw mount AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY77-7-6755Y 1200 - 1 240 52,3 Through hole Screw mount HY77-9-5055Y 500 - 1 100 39,6 Through hole Screw mount HY77-9-5155Y 600 - 1 120 39,6 Through hole Screw mount HY77-9-5205Y 75 - 2 15 39,6 Through hole Screw mount HY77-9-5205Y 750 - 1 150 39,6 Through hole Screw mount HY77-9-5355Y 800 - 1 160 39,6 Through hole Screw mount HY77-9-5505Y 50 - 2 10 39,6 Through hole Screw mount HY77-9-5605Y 150 - 1 30 39,6 Through hole Screw mount AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY77-9-5655Y 100 - 2 20 39,6 Through hole Screw mount HY77-9-5705Y 250 - 1 50 39,6 Through hole Screw mount HY77-9-5755Y 200 - 1 40 39,6 Through hole Screw mount HY77-9-5855Y 300 - 1 60 39,6 Through hole Screw mount HY77-9-5955Y 400 - 1 80 39,6 Through hole Screw mount HY77-9-6555Y 1000 - 1 200 39,6 Through hole Screw mount HY77-9-6755Y 1200 - 1 240 39,6 Through hole Screw mount HY79-0-755U 100 200 1 2000 25 Split core - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY79-0-855U 200 250 1 3000 25 Split core - HY79-2-755R 60 90 2 2000 20.3x26.9 Split core - HY79-2-855R 80 120 2 3000 20.3x26.9 Split core - HY79-2-955R 100 150 1 4000 20.3x26.9 Split core - HY79-3-855R 100 120 1 3000 15.7 Split core - HY79-4-605R 15 30 5 1500 16.7 Split core - HY79-6-855R 60 70 2 3000 9.6 Split core - HY79-9-655U 30 60 2 1000 23 Split core - AC-Stromwandler www.pewatron.com Produkt 23.04.2016 Typ Nom. Messstrom [A] Max. Messstrom [A] Fehler [%] Anzahl Windungen Lochgrösse [mm] Bauart Montageart HY79-9-755U 40 80 2 2000 24 Split core - HX2R5X 2.5 2.5 2 - 9.5 Split core - HX100X 10 10 2 - 9.5 Split core - HX200X 20 20 2 - 9.5 Split core - HX500X 50 50 2 - 9.5 Split core - HX101X 100 100 2 - 9.5 Split core - AC-Stromwandler www.pewatron.com Wir sind für Sie da. Adressen und Kontakte Verkauf Schweiz & Liechtenstein Verkauf International Key Account Verkauf Deutschland PLZ 00000 –59999 PLZ 80000 –99999 PLZ 60000 – 79999 Matthias Rüegg Ruhbergstrasse 32 CH-9230 Flawil Peter Felder Thurgauerstrasse 66 CH-8052 Zürich Kurt Stritzelberger Neumarkter Str. 86a D-81673 München Dieter Hirthe Auf der Entenweide 4 69502 Hemsbach Tel. + 41 44 877 35 18 Mobil + 41 76 491 66 66 Fax + 41 44 877 35 19 Tel. + 41 44 877 35 05 Mobil + 41 79 406 49 83 Fax + 41 44 877 35 25 Tel. + 49 89 260 38 47 Mobil + 49 171 803 41 35 Fax + 49 89 43 10 91 91 Tel. + 49 6201 508 9250 Mobil + 49 1637 627 430 Fax + 49 6201 508 9751 [email protected] [email protected] [email protected] [email protected] Stromversorgungen E-Komponenten DC-DC Wandler Schaltnetzgeräte DC-AC Inverter Stromwandler Mensch-Maschine-Schnittstelle Messsonden Sebastiano Leggio Tel. + 41 44 877 35 06 [email protected] Sebastiano Leggio Tel. + 41 44 877 35 06 [email protected] Verkauf Österreich Verkauf andere Länder / Product Management Sensoren Kurt Stritzelberger Neumarkter Str. 86a D-81673 München Physikalische Sensoren Datenerfassung Tel. + 49 89 260 38 47 Mobil + 49 171 803 41 35 Fax + 49 89 43 10 91 91 Thomas Clausen Tel. + 41 44 877 35 13 [email protected] Geometrische Sensoren Eric Letsch Tel. + 41 44 877 35 14 [email protected] PEWATRON AG Thurgauerstrasse 66 CH-8052 Zürich Tel. Fax + 41 44 877 35 00 + 41 44 877 35 25 www.pewatron.com [email protected] [email protected] Supporting your great ideas www.pewatron.com
© Copyright 2024 ExpyDoc